• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detecção de fraude no leite com água pela capacidade térmica volumétrica

Pinheiro, Luciana Aquino Ferreira 31 August 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-11T10:56:19Z No. of bitstreams: 1 lucianaaquinoferreirapinheiro.pdf: 1091146 bytes, checksum: 8a187bf82a998ca568c832a837fc7ad1 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-20T15:29:03Z (GMT) No. of bitstreams: 1 lucianaaquinoferreirapinheiro.pdf: 1091146 bytes, checksum: 8a187bf82a998ca568c832a837fc7ad1 (MD5) / Made available in DSpace on 2016-06-20T15:29:03Z (GMT). No. of bitstreams: 1 lucianaaquinoferreirapinheiro.pdf: 1091146 bytes, checksum: 8a187bf82a998ca568c832a837fc7ad1 (MD5) Previous issue date: 2015-08-31 / O leite é considerado um alimento importante para uma alimentação saudável, por ser fonte de vários nutrientes como: carboidrato, proteínas, vitaminas e minerais, os quais estão envolvidos no processo de nutrição e prevenção de doenças de diversas faixas etárias e estados fisiológicos. Faz parte do hábito alimentar do brasileiro e também muito sujeito a fraudes. Portanto, devido este alimento estar presente diariamente na vida das pessoas, é de grande importância o desenvolvimento de novas técnicas para detectar fraudes envolvendo o leite. Uma das adulterações mais frequentes é a adição de água, que é um método muito antigo e utilizado para aumentar o seu rendimento, sendo economicamente viável para o produtor. Porém, esse tipo de alteração, além de lesar o consumidor, coloca em risco a saúde do mesmo. O presente trabalho teve como objetivo desenvolver um novo método de análise do leite para verificar a fraude por aguagem, utilizando a técnica da capacidade térmica volumétrica e também avaliar a sua eficácia em comparação aos métodos de referência, como: crioscopia e densidade. O trabalho foi desenvolvido no Laboratório de Espectroscopia de Materiais do Departamento de Física, da Universidade Federal de Juiz de Fora. O leite utilizado nos testes foi fornecido pelo Instituto de Laticínios Cândido Tostes da Empresa de Pesquisa Agropecuária de Minas Gerais – EPAMIG. Os testes foram realizados simulando adulterações do leite, de forma a obter-se dez amostras: sendo a amostra 1 o controle, ou seja, leite cru integral refrigerado, e as demais com a substituição parcial do volume do leite por água, nas seguintes porcentagens: 1, 2, 4, 6, 8, 10, 20, 30 e 40% da massa da amostra de leite em água. Na avaliação das amostras utilizouse três repetições. O resultado da amostra controle foi comparado com valores encontrados na literatura. A partir das análises realizadas foi possível concluir que, a técnica se mostrou eficiente na detecção de fraudes por aguagem até a adulteração de 10%, mas se mostrando capaz de ser mais precisa por melhoramento da montagem experimental. / Milk is considered an important food for a healthy diet, being source of various nutrients such as carbohydrate, protein, vitamins and minerals, which are involved in the process of nutrition and prevention of diseases of different ages and physiological states. It’s part of Brazilian alimentary habit and also very prone to fraud. Therefore, because this food is present every day in people's lives, is of great importance the development of new techniques to detect fraud involving milk. One of the most frequent adulteration is the addition of water, which is a very old method and used to increase your income and is economically viable for the producer. However, this type of change, and harm consumers, endangers the health of it. This study aimed to develop a new milk analysis method to check fraud by aguagem, using the specific heat capacity technique and also evaluate their effectiveness compared to reference methods, such as freezing point and density. The study was conducted at the Laboratory of Spectroscopy of Materials Physics Department of the Universidade Federal de Juiz de Fora. The milk used in the tests was provided by the Instituto de Laticínios Cândido Tostes the Agricultural Research Company of Minas Gerais – EPAMIG. The tests were performed simulating the milk adulteration, so as to obtain ten samples: Sample 1 the control, ie, full-cooled raw milk, and the other with the partial replacement of milk by volume water in the following percentages 1, 2, 4, 6, 8, 10, 20, 30 and 40% of the mass of water in the sample milk. In the evaluation of the samples used were three replications. The result of the control sample was compared with values found in the literature. From the analyzes it was concluded that the technique was efficient in detecting fraud by aguagem to the adulteration of 10%, but proving to be able to be more precise by improving the experimental setup.
2

Implantação das técnicas de fotoacústica e pc e aplicações em sistemas vítreos

Silva, Alexandre Pinheiro da 30 September 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-07-24T12:08:43Z No. of bitstreams: 1 alexandrepinheirodasilva.pdf: 29097377 bytes, checksum: 94bcde5f459e88c78cffbdf774e348a0 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-09T13:30:24Z (GMT) No. of bitstreams: 1 alexandrepinheirodasilva.pdf: 29097377 bytes, checksum: 94bcde5f459e88c78cffbdf774e348a0 (MD5) / Made available in DSpace on 2017-08-09T13:30:24Z (GMT). No. of bitstreams: 1 alexandrepinheirodasilva.pdf: 29097377 bytes, checksum: 94bcde5f459e88c78cffbdf774e348a0 (MD5) Previous issue date: 2011-09-30 / Neste trabalho vamos apresentar a implantação de duas técnicas fototérmicas: a fotoacústica de câmara aberta que possibilita encontrarmos a difusividade térmica dos materiais, e a técnica pc que fornece o valor do produto da densidade pelo calor específico da substância, conhecido como capacidade térmica volumétrica. Utilizamos também a técnica de lente térmica para a medida da difusividade térmica e do parâmetro dS/dT (taxa de variação do caminho óptico S). As técnicas mencionadas fornecem os parâmetros termo-ópticos (Difusividade Térmica, Condutividade Térmica e dS/dT ) para materiais vítreos como os vidros ferro fosfato, telurito, borossilicato e simulado lunar JSC-1. Modelos teóricos são apresentados e testados. Mostramos que o modelo da flexão termoelástica é dominante na maioria das amostras estudadas. Exceção foi observado no caso de vidros semicondutores (ferro fosfato). Neste caso, correções foram necessárias para o modelo da flexão termoelástica, possibilitando obter: difusividade térmica, coeficiente de difusão de portadores, velocidade de recombinação dos portadores na superfície e tempo de recombinação na superfície. As técnicas foram testadas com amostras de alumínio com 99,99 % de pureza, que possuem as informações térmicas disponíveis na literatura. Nos resultados, identificamos, através da técnica fotoacústica, que o vidro ferro fosfato é um vidro semi-condutor. Vidros ferro fosfato são candidatos para aplicações de vitrificação de resíduos nucleares. Comparações foram feitas com vidros borossilicato que são atualmente usados na vitrificação dos resíduos nucleares. Obtivemos a difusividade térmica, a capacidade térmica volumétrica e a condutividade térmica dos vidros do simulado lunar JSC-1 e telurito. O primeiro se mostrou eficiente para aplicações em exploração espacial e o segundo tem potencial aplicação em dispositivos fotônicos. / In this work we present the implantation of two photothermal techniques : the open cell photoacoustic which allows one to find thermal diffusivity of materials, and pc technique which gives the value of the product of density by specific heat of substance, known as the volumetric heat capacity. We also used the technique of thermal lens for measurement of thermal diffusivity and the parameter dS/dT (the temperature coefficient of the optical path S). The mentioned techniques furnished the thermo-optical parameters (Thermal Diffusivity, Thermal Conductivity and dS/dT) of glassy materials such as iron phosphate, tellurite, borosilicate glasses and lunar simulate JSC-1. Theoretical Models are presented and tested. It was shown that the model of thermoelastic bending is dominant in most samples studied. Exception is observed in the case of semiconducting glasses (iron phosphate). In this case, corrections were necessary to the bending model, and allowed one to obtain: thermal diffusivity, carrier 's diffusion coefficient, carriers surface recombination velocity and surface recombination time. Techniques were tested with aluminum samples with 99.99 % purity, which have the thermal information available in the literature. As a result, we identified, through the photoacoustic technique, that iron phosphate glass is a semiconductor glass. Iron phosphate are candidates for nuclear waste vitrification applications. Comparison was made with borosilicate glasses that are currently used for nuclear waste vitrification. We also obtained the thermal diffusivity, the volumetric heat capacity and thermal conductivity of simulated lunar JSC-1 and tellurite glasses. The former proved efficient applications in space exploration and the latter has potential applications as photonic device.

Page generated in 0.1133 seconds