• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Intrinsic degradation mechanisms of barium titanate based multilayer ceramic capacitors

Schunke, J. Neil January 1985 (has links)
A study was conducted into the intrinsic degradation behavior of X7R and Z5U capacitors. The major goals of this research were: 1) to determine current-voltage, activation energy and leakage current characteristics for such capacitors. 2) to investigate how these characteristics change with degradation; 3) to investigate possible correlations between observed behavior and capacitor microstructure or composition. Examination of capacitor microstructures revealed large differences in grain morphology and electrode spacings. The development of a color gradient between positive and negative electrodes with. degradation was observed in one type of capacitor. Compositional studies using EDAX, AUGER, and microprobe analyses failed to detect gradients in dielectric composition in degraded capacitors indicating that gradients are less than 0.1 atomic percent. Current-voltage studies showed a 3/2 power dependance, at voltages above one volt for X7R capacitors indicating space charge limited current. This dependance was attributed to point emission from electrode protuberances. The 3/2 dependance was observed to shift to a square law behavior with degradation. This change was attributed to a increase in conductivity of the dielectric near the cathode, blunting the effect of electrode protuberances. Z5U capacitors were found to have ohmic behavior. No Schottky or Poole Frenkel currents were observed. Degradation studies were carried out on capacitors at 2 to 8 times the rated voltage, and at temperatures from 100 to 1500℃. Leakage currents in actively degrading capacitors were observed to rise exponentially with time. This rise was accompanied by a gradual decrease in activation energy. A model is proposed to explain the observed current vs degradation behavior. / Master of Science
2

Equacionamento e modelagem da bobina bifilar de tesla e proposta da sua utilização como um sensor biotelemétrico autorressonante

Miranda, Caio Marcelo de 19 June 2012 (has links)
CAPES e CNPq / A Biotelemetria apresenta-se como uma importante técnica que possui várias aplicações na área de Engenharia Biomédica e outras. A miniaturização da unidade sensora é um grande desafio dentro desta área, sendo que na maioria dos casos, deseja-se uma unidade menor possível. Desta maneira, sensores passivos são interessantes, pois possibilitam uma menor dimensão do dispositivo e não necessitam de uma fonte própria de energia, ou bateria, que pode causar danos ao indivíduo monitorado caso ocorra vazamento do seu conteúdo químico. Deste modo, o sensor indutivo autorressonante apresenta-se como uma promissora solução, uma vez que este pode ser construído com apenas um componente, um indutor, que utiliza a sua própria capacitância parasita no lugar de um capacitor externo. Por apresentar pequenas dimensões, este tipo de sensor possui uma baixa capacitância parasita, o que torna a sua frequência de ressonância bastante alta. Isso pode resultar em alguns problemas e até mesmo inviabilizar o projeto. Neste caso, a bobina bifilar idealizada por Nikola Tesla pode ser uma solução, uma vez que o objetivo de Tesla foi aumentar a capacitância intrínseca de suas bobinas. Portanto, um entendimento físico e devido equacionamento da bobina bifilar se faz necessário, uma vez que, até onde se sabe, este tipo de abordagem não existe na literatura. A partir de uma análise física em função das tensões entre espiras adjacentes da bobina bifilar de Tesla, foi desenvolvido um equacionamento que possibilita a determinação do aumento da capacitância interna e, consequente, redução na frequência de ressonância da bobina bifilar. Um modelo elétrico equivalente da bobina também foi elaborado através desta análise. Testes foram realizados para validar a análise física, e comparar a frequência de autorressonância calculada e medida para diversos números de espiras, de modo a comprovar a validade do modelo e das equações desenvolvidas. Um sensor biotelemétrico indutivo autorressonante, para medição de deslocamentos, utilizando a bobina bifilar de Tesla, foi desenvolvido para caracterizar a sua utilização como um sensor biomédico. / Biotelemetry is an important technique with many applications in biomedical engineering and other areas. The size of the remote unit or sensor is a major challenge in this area, and, in most cases, a sensor is desired to be as small as possible. Thus, passive sensors are interesting because they allow a smaller dimensions and do not require a power source or battery, which can harm the patient in the event of leakage of its chemical content. Thus, the self-ressonant inductive sensor is a good solution since it can be built with only one component. Due to its small size, this type of sensor has a low stray capacitance, which makes its self-resonance frequency very high. In this case, the bifilar coil, devised by Nikola Tesla, can be a solution, since Tesla's idea was to increase the intrinsic capacitance of his coils. Therefore a physical understanding of the bifilar coil is necessary, since as far as is known, this approach does not exist in the literature. From an analysis of the voltage between adjacent turns, equations of the Tesla's bifilar coil were developed, allowing the prediction of the increase on the internal capacitance and consequent reduction of the resonance frequency. An equivalent electric model was also developed from this analysis. This allowed the project of bifilar coils and the calculation of the internal capacitances and self-resonance frequencies of these coils. Tests were realized in order to compare the calculated and measured self-resonance for various numbers of turns, showing the validity of the presented method. A passive self-resonant biotelemetric sensor for displacement measurement using the Tesla's bifilar coil, was also developed.
3

Equacionamento e modelagem da bobina bifilar de tesla e proposta da sua utilização como um sensor biotelemétrico autorressonante

Miranda, Caio Marcelo de 19 June 2012 (has links)
CAPES e CNPq / A Biotelemetria apresenta-se como uma importante técnica que possui várias aplicações na área de Engenharia Biomédica e outras. A miniaturização da unidade sensora é um grande desafio dentro desta área, sendo que na maioria dos casos, deseja-se uma unidade menor possível. Desta maneira, sensores passivos são interessantes, pois possibilitam uma menor dimensão do dispositivo e não necessitam de uma fonte própria de energia, ou bateria, que pode causar danos ao indivíduo monitorado caso ocorra vazamento do seu conteúdo químico. Deste modo, o sensor indutivo autorressonante apresenta-se como uma promissora solução, uma vez que este pode ser construído com apenas um componente, um indutor, que utiliza a sua própria capacitância parasita no lugar de um capacitor externo. Por apresentar pequenas dimensões, este tipo de sensor possui uma baixa capacitância parasita, o que torna a sua frequência de ressonância bastante alta. Isso pode resultar em alguns problemas e até mesmo inviabilizar o projeto. Neste caso, a bobina bifilar idealizada por Nikola Tesla pode ser uma solução, uma vez que o objetivo de Tesla foi aumentar a capacitância intrínseca de suas bobinas. Portanto, um entendimento físico e devido equacionamento da bobina bifilar se faz necessário, uma vez que, até onde se sabe, este tipo de abordagem não existe na literatura. A partir de uma análise física em função das tensões entre espiras adjacentes da bobina bifilar de Tesla, foi desenvolvido um equacionamento que possibilita a determinação do aumento da capacitância interna e, consequente, redução na frequência de ressonância da bobina bifilar. Um modelo elétrico equivalente da bobina também foi elaborado através desta análise. Testes foram realizados para validar a análise física, e comparar a frequência de autorressonância calculada e medida para diversos números de espiras, de modo a comprovar a validade do modelo e das equações desenvolvidas. Um sensor biotelemétrico indutivo autorressonante, para medição de deslocamentos, utilizando a bobina bifilar de Tesla, foi desenvolvido para caracterizar a sua utilização como um sensor biomédico. / Biotelemetry is an important technique with many applications in biomedical engineering and other areas. The size of the remote unit or sensor is a major challenge in this area, and, in most cases, a sensor is desired to be as small as possible. Thus, passive sensors are interesting because they allow a smaller dimensions and do not require a power source or battery, which can harm the patient in the event of leakage of its chemical content. Thus, the self-ressonant inductive sensor is a good solution since it can be built with only one component. Due to its small size, this type of sensor has a low stray capacitance, which makes its self-resonance frequency very high. In this case, the bifilar coil, devised by Nikola Tesla, can be a solution, since Tesla's idea was to increase the intrinsic capacitance of his coils. Therefore a physical understanding of the bifilar coil is necessary, since as far as is known, this approach does not exist in the literature. From an analysis of the voltage between adjacent turns, equations of the Tesla's bifilar coil were developed, allowing the prediction of the increase on the internal capacitance and consequent reduction of the resonance frequency. An equivalent electric model was also developed from this analysis. This allowed the project of bifilar coils and the calculation of the internal capacitances and self-resonance frequencies of these coils. Tests were realized in order to compare the calculated and measured self-resonance for various numbers of turns, showing the validity of the presented method. A passive self-resonant biotelemetric sensor for displacement measurement using the Tesla's bifilar coil, was also developed.

Page generated in 0.0867 seconds