• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tests of concrete flanged beams reinforced with CFRP bars.

Ashour, Ashraf, Family, M. 11 1900 (has links)
Yes / Tests results of three flanged and two rectangular cross-section concrete beams reinforced with carbon fibre reinforced polymer (CFRP) bars are reported. In addition, a companion concrete flanged beam reinforced with steel bars is tested for comparison purposes. The amount of CFRP reinforcement used and flange thickness were the main parameters investigated in the test specimens. One CFRP reinforced concrete rectangular beam exhibited concrete crushing failure mode, whereas the other four CFRP reinforced concrete beams failed due to tensile rupture of CFRP bars. The ACI 440 design guide for FRP reinforced concrete members underestimated the moment capacity of beams failed due to CFRP tensile rupture and reasonably predicted deflections of the beams tested. A simplified theoretical analysis for estimating the moment capacity of concrete flanged beams reinforced with FRP bars was developed. The experimental moment capacity of the CFRP reinforced concrete beams tested compared favourably with that predicted by the theoretical analysis developed.
2

CFRP strengthened continuous concrete beams.

El-Refaie, S.A., Ashour, Ashraf, Garrity, S.W. 11 1900 (has links)
Yes / This paper reports the testing of five reinforced concrete continuous beams strengthened in flexure with externally bonded carbon-fibre-reinforced polymer (CFRP) laminates. All beams had the same geometrical dimensions and internal steel reinforcement. The main parameters studied were the position and form of the CFRP laminates. Three of the beams were strengthened using different arrangements of CFRP plate reinforcement, and one was strengthened using CFRP sheets. The performance of the CFRP-strengthened beams was compared with that of an unstrengthened control beam. Peeling failure was the dominant mode of failure for all the strengthened beams tested. The beam strengthened with both top and bottom CFRP plates produced the highest load capacity. It was found that the longitudinal elastic shear stresses at the adhesive/concrete interface calculated at beam failure were close to the limiting value recommended in Concrete Society Technical Report 55.
3

Tests of continuous concrete slabs reinforced with carbon fibre reinforced polymer bars

Mahroug, Mohamed E.M., Ashour, Ashraf, Lam, Dennis 11 June 2014 (has links)
No / Although several research studies have been conducted on simply supported concrete elements reinforced with fibre reinforced polymer (FRP) bars, there is little reported work on the behaviour of continuous elements. This paper reports the testing of four continuously supported concrete slabs reinforced with carbon fibre reinforced polymer (CFRP) bars. Different arrangements of CFRP reinforcement at mid-span and over the middle support were considered. Two simply supported concrete slabs reinforced with under and over CFRP reinforcement and a continuous concrete slab reinforced with steel bars were also tested for comparison purposes. All continuous CFRP reinforced concrete slabs exhibited a combined shear–flexure failure mode. It was also shown that increasing the bottom mid-span CFRP reinforcement of continuous slabs is more effective than the top over middle support CFRP reinforcement in improving the load capacity and reducing mid-span deflections. The ACI 440.1R–06 formulas overestimated the experimental moment at failure but better predicted the load capacity of continuous CFRP reinforced concrete slabs tested. The ACI 440.1R–06, ISIS–M03–07 and CSA S806-06 design code equations reasonably predicted the deflections of the CFRP continuously supported slabs having under reinforcement at the bottom layer but underestimated deflections of continuous slabs with over-reinforcement at the bottom layer.
4

Debonding of external CFRP plates from RC structures caused by cyclic loading effects

Badenhorst, Adriaan Jakobus 03 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2012. / ENGLISH ABSTRACT: This study set out to determine the debonding of externally applied Carbon Fibre Reinforced Polymer (CFRP) plates from RC structures under cyclic loading. Triplet shear tests and finite element (FE) analyses were done on the epoxy to determine the bond stress between the CFRP plate and a reinforced concrete specimen. From these tests and analyses the average shear strength of the bond between the epoxy and concrete substrate was determined and the shear strength of the epoxy specified by the supplier could be confirmed. A case study of a statically loaded beam was performed to verify the bond strength. Finally a reinforced concrete (RC) T-section was designed and pre-cracked to simulate a damaged beam in practice. These sections were then externally reinforced by bonding CFRP plates onto the face of the web. The sections were subjected to static and cyclic loading at different force amplitudes. Along with the experimental tests, FE models were developed and analysed which had the same geometrical and material properties as the experimental specimens. Due to time constraint a FE mesh objectivity study was not done, but the chosen element size is believed to be sufficiently small to replicate the experimental tests objectively. The FE analyses and the experimental tests yielded results that were close to each other on both the global scale and in terms of localised behaviour, thus it was decided that the computational approach could be used for the final design of a model of the debonding of CFRP plates bonded onto RC beams under cyclic loading because the data can be analysed more easily and a large variation of tests can be done. For the T-section 3 tests were conducted; a pull-off (static) test where the bonded CFRP plate was pulled from a specimen to get the ultimate failure envelope of the test specimens. The static test was followed by cyclic tests with force amplitude of 85% and 65% of the ultimate pull-off strength. Different measurements were taken to get the global and local displacement behaviour of the section. The global displacement was measured by means of a linear variable displacement transducer (LVDT, displacement meter) clamped onto the CFRP plate that pushed on the top of the concrete and the local displacement was measured with the help of the Aramis system. The displacement was then compared to the same displacements of nodes and elements in the FE models. The result was a confirmation that the results from the FE models were sufficient to design a model for cyclic debonding of CFRP plates from RC structures. From the FE models the relative displacement between the CFRP plate and concrete was obtained in the vicinity of a crack. This relative displacement was then normalised by the respective stress range of the different tests, from which the normalised relative displacement was plotted against the number of cycles to get an equation limiting the number of cycles for a specific stress range. From the results, it appears that for cyclic load levels up to 65% of the peak static resistance, a threshold number of load cycles are required for delamination initiation. Subsequently, a near constant delamination rate is reached. The delamination rate is significantly lower for lower cyclic load levels. Finally, an unstable delamination stage is reached at a level of about 65 μm for all the analyses, after which CFRP pull-off is imminent. Service life design of CFRP reinforcement of RC beams should take into consideration the delamination initiation threshold, the subsequent delamination rate and finally the initiation of unstable delamination. / AFRIKAANSE OPSOMMING: Die projek is uitgevoer om die delaminasie van ekstern aangewende Koolstof Vesel Versterkte Polimeer (KVVP) stroke op gewapende beton strukture te bepaal onder sikliese belasting. Triplet skuif toetse is gedoen op die gebruikte epoksie om die verband-sterkte te bepaaltussen die KVVP stroke en die beton proefstuk. Die skuif toetse is ook met behulp van die eindige element (EE) metode geanaliseer. Die resultaat van die toetse en analises het gewys dat die verband sterkte tussen die KVVP stroke en beton gelyk is aan die skuif sterkte van die epoksie wat verskaf is. `n Gevalle studie van `n monotonies belaste balk is gedoen om die verband-sterkte te verifieër. `n Gewapende beton T-snit is ontwerp en voor-af gekraak om `n beskadigde balk in die praktyk voor te stel. Die beskadigde proefstukke is vervolgens ekstern versterk met KVVP stroke wat aan die web van die T-snit vas geplak is. Die versterkte T-snitte is getoets onder statiese en sikliese belasting. Die sikliese toetse is ook onder verskillende spanningsamplitudes getoets. Om die eksperimentele toetse te verifieër is EE modelle gebou en geanaliseer wat dieselfde geometriese en materiaal eienskappe as die eksperimentele proefstukke gehad het, maar as gevolg van `n tydsbeperking is `n sensitiwiteit studie oor die element grootte nie gedoen nie. Die element grootte is klein genoeg gekies en word beskou as voldoende om die gedrag objektief te simuleer. Die EE analises en eksperimentele resultate was na genoeg aan mekaar op beide globale en lokale vlak. Dus is `n analitiese benadering tot die toetse vervolgens gebruik vir die ontwerp van `n model vir delaminasie van KVVP stroke van gewapende beton strukture onder sikliese belasting. Die EE metode stel die analis in staat om `n verskeidenheid van toetse relatief vinnig uit te voer en om die data van die toetse vinniger te interpreteer as deur fisiese eksperimentele toetse. Drie eksperimente is uitgevoer op die T-snitte, `n aftrek-toets (staties) waar die KVVP strook van `n proefstuk afgetrek is om die falingsomhullende diagram te kry en dan ook twee sikliese toetse teen 85% en 65% van die krag amplitude van die falingskrag. Verplasingsmeters is gebruik om die globale verplasing te kry, deur dit vas te klamp op die KVVP strook en dan die verplasing te meet relatief tot die bokant van die beton. Die lokale veplasing is met behulp van die Aramis sisteem verkry. Die eksperimentele verplasings is dan vergelyk met verplasings van die ooreenstemmende nodes en elemente in die EE modelle. Deur die vergelyking van die resultate is dit bevestig dat die eindige element modelle voldoende is om die model vir sikliese delaminasie van KVVP stroke van gewapende beton strukture te gebruik vir die ontwerp. Uit die EE modelle is die relatiewe verplasing tussen die KVVP strook en die beton gekry in die omgewing van `n kraak. Die relatiewe verplasing is genormaliseer deur elkeen se spanningsamplitude. Die genormaliseerde relatiewe verplasing is dan teenoor die aantal siklusse geteken waarvan `n vergelyking vir die maksimum verplasing afgelei is om die aantal siklusse vir `n gegewe spanning amplitude te beperk. Uit die resultate blyk dit dat vir sikliese laste tot en met 65% van die piek statiese weerstand `n aantal siklusse moontlik is voordat delaminasie begin waarna `n konstante delaminasie tempo bereik word. Die delaminasie tempo is stadiger vir sikliese laste teen `n laer belastings amplitude. Laastens word `n onstabiele delaminasie fase bereik by `n vlak van ongeveer 65 μm, na die oorgang delamineer die KVVP strook binne enkele siklusse. Die beginpunt van delaminasie, die delaminasie tempo en laastens die begin van onstabiele delaminasie moet in gedagte gehou word by die ontwerp diens leeftyd van KVVP versterkte gewapende beton balke.
5

Behaviour of continuous concrete slabs reinforced with FRP bars : experimental and computational investigations on the use of basalt and carbon fibre reinforced polymer bars in continuous concrete slabs

Mahroug, Mohamed Elarbi Moh January 2013 (has links)
An investigation on the application of basalt fibre reinforced polymer (BFRP) and carbon fibre reinforced polymer (CFRP) bars as longitudinal reinforcement for simple and continuous concrete slabs is presented. Eight continuously and four simply concrete slabs were constructed and tested to failure. Two continuously supported steel reinforced concrete slabs were also tested for comparison purposes. The slabs were classified into two groups according to the type of FRP bars. All slabs tested were 500 mm in width and 150 mm in depth. The simply supported slabs had a span of 2000 mm, whereas the continuous slabs had two equal spans, each of 2000 mm. Different combinations of under and over FRP (BFRP/CFRP) reinforcement at the top and bottom layers of slabs were investigated. The continuously supported BFRP and CFRP reinforced concrete slabs exhibited larger deflections and wider cracks than the counterpart reinforced with steel. The experimental results showed that increasing the bottom mid-span FRP reinforcement of continuous slabs is more effective than the top over middle support FRP reinforcement in improving the load capacity and reducing mid-span deflections. Design guidelines have been validated against experimental results of FRP reinforced concrete slabs tested. ISIS-M03-07 and CSA S806-06 equations reasonably predicted the deflections of the slabs tested. However, ACI 440-1R-06 underestimated the deflections, overestimated the moment capacities at mid-span and over support sections, and reasonably predicted the load capacity of the continuous slabs tested. On the analytical side, a numerical technique consisting of sectional and longitudinal analyses has been developed to predict the moment-curvature relationship, moment capacity and load-deflection of FRP reinforced concrete members. The numerical technique has been validated against the experimental test results obtained from the current research and those reported in the literature. A parametric study using the numerical technique developed has also been conducted to examine the influence of FRP reinforcement ratio, concrete compressive strength and type of reinforcement on the performance of continuous FRP reinforced concrete slabs. Increasing the concrete compressive strength decreased the curvature of the reinforced section with FRP bars. Moreover, in the simple and continuous FRP reinforced concrete slabs, increasing the FRP reinforcement at the bottom layer fairly reduced and controlled deflections.
6

Behaviour of continuous concrete slabs reinforced with FRP bars. Experimental and computational investigations on the use of basalt and carbon fibre reinforced polymer bars in continuous concrete slabs.

Mahroug, Mohamed E.M. January 2013 (has links)
An investigation on the application of basalt fibre reinforced polymer (BFRP) and carbon fibre reinforced polymer (CFRP) bars as longitudinal reinforcement for simple and continuous concrete slabs is presented. Eight continuously and four simply concrete slabs were constructed and tested to failure. Two continuously supported steel reinforced concrete slabs were also tested for comparison purposes. The slabs were classified into two groups according to the type of FRP bars. All slabs tested were 500 mm in width and 150 mm in depth. The simply supported slabs had a span of 2000 mm, whereas the continuous slabs had two equal spans, each of 2000 mm. Different combinations of under and over FRP (BFRP/CFRP) reinforcement at the top and bottom layers of slabs were investigated. The continuously supported BFRP and CFRP reinforced concrete slabs exhibited larger deflections and wider cracks than the counterpart reinforced with steel. The experimental results showed that increasing the bottom mid-span FRP reinforcement of continuous slabs is more effective than the top over middle support FRP reinforcement in improving the load capacity and reducing mid-span deflections. Design guidelines have been validated against experimental results of FRP reinforced concrete slabs tested. ISIS¿M03¿07 and CSA S806-06 equations reasonably predicted the deflections of the slabs tested. However, ACI 440¿1R-06 underestimated the deflections, overestimated the moment capacities at mid-span and over support sections, and reasonably predicted the load capacity of the continuous slabs tested. On the analytical side, a numerical technique consisting of sectional and longitudinal analyses has been developed to predict the moment¿curvature relationship, moment capacity and load-deflection of FRP reinforced concrete members. The numerical technique has been validated against the experimental test results obtained from the current research and those reported in the literature. A parametric study using the numerical technique developed has also been conducted to examine the influence of FRP reinforcement ratio, concrete compressive strength and type of reinforcement on the performance of continuous FRP reinforced concrete slabs. Increasing the concrete compressive strength decreased the curvature of the reinforced section with FRP bars. Moreover, in the simple and continuous FRP reinforced concrete slabs, increasing the FRP reinforcement at the bottom layer fairly reduced and controlled deflections.
7

Development and application of a novel test method for studying the fire behaviour of CFRP prestressed concrete structural elements

Maluk, Cristian January 2014 (has links)
A novel type of precast, prestressed concrete structural element is being implemented in load-bearing systems in buildings. These structural elements combine the use of high-performance, self-consolidating concrete (HPSCC) and non-corroding carbon fibre reinforced polymer (CFRP) prestressing tendons; this produces highly optimized, slender structural elements with excellent serviceability and (presumed) extended service lives. More widely, the use of new construction techniques, innovative materials, and ground-breaking designs is increasingly commonplace in today's rapidly evolving building construction industry. However, the performance of these and other structural elements in fire is in general not well known and must be understood before these can be used with confidence in load-bearing applications where structural fire resistance is a concern. Structural fire testing has traditionally relied on the use of the standard fire resistance test (i.e. furnace test) for assuring regulatory compliance of structural elements and assemblies, and in many cases also for developing the scientific understanding of structural response to fire. Conceived in the early 1900s and fundamentally unchanged since then, the standard testing procedure is characterized by its high cost and low repeatability. A novel test method, the Heat-Transfer Rate Inducing System (H-TRIS), resulting from a mental shift associated with controlling the thermal exposure not by temperature (e.g. temperature measured by thermocouples) but rather by the time-history of incident heat flux, was conceived, developed, and validated within the scope of the work presented in this thesis. H-TRIS allows for experimental studies to be carried out with high repeatability, imposing rationally quantifiable thermal exposure, all at low economic and temporal cost. The research presented in this thesis fundamentally seeks to examine and understand the behaviour of CFRP prestressed HPSCC structural elements in fire, with emphasis placed on undesired 'premature' failure mechanisms linked to the occurrence of heat-induced concrete spalling and/or loss of bond between the pretensioned CFRP tendons and the concrete. Results from fire resistance tests presented herein show that, although compliant with testing standards, temperature distributions inside furnaces (5 to 10% deviation) appear to influence the occurrence of heat-induced concrete spalling for specimens tested simultaneously during a single test; fair comparison of test results is therefore questionable if thermal exposure variability is not explicitly considered. In line with the aims of the research presented in this thesis, H-TRIS is used to carry out multiple comprehensive studies on the occurrence of concrete spalling and bond behaviour of CFRP tendons; imposing a quantified, reproducible and rational thermal exposure. Test results led to the conclusion that a "one size fits all" approach for mitigating the risk of heat-induced concrete spalling (e.g. prescribed dose of polypropylene (PP) fibres included in fresh concrete), appears to be ineffective and inappropriate in some of the conditions examined. This work demonstrates that PP fibre cross section and individual fibre length can have an influence on the risk of spalling for the HPSCC mixes tested herein. The testing presented herein has convincingly shown, for the first time using multiple repeated tests under tightly controlled thermal and mechanical conditions, that spalling depends not only on the thermal gradients in concrete during heating but also on the size and restraint conditions of the tested specimen. Furthermore, observations from large scale standard fire resistance tests showed that loss of bond strength of pretensioned CFRP tendons occurred at a 'critical' temperature of the tendons in the heated region, irrespective of the temperature of the tendons at the prestress transfer length, in unheated overhangs. This contradicts conventional wisdom for the structural fire safety design of concrete elements pretensioned with CFRP, in which a minimum unheated overhang is generally prescribed. Overall, the research studies presented in this thesis showed that a rational and practical understanding of the behaviour of CFRP prestressed HPSCC structural elements during real fires is unlikely to be achieved only by performing additional standard fire resistance tests. Hence, H-TRIS presents an opportunity to help promote an industry-wide move away from the contemporary pass/fail and costly furnace testing environment. Recommendations for further research to achieve the above goal are provided.

Page generated in 0.0768 seconds