• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • 40
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 85
  • 40
  • 33
  • 32
  • 17
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da definição do ângulo cavossuperficial em preparos cavitários realizados com instrumentações rotatória e ultrassônica / Evaluation of cavosurface margin definition in dental cavity preparations made with rotary and ultrasonic instrumentation

Ricardo Virgolino Carvalho da Silva 16 April 2010 (has links)
O objetivo deste estudo foi avaliar a definição do ângulo cavossuperficial em preparos realizados com instrumentações rotatória e ultrassônica com o sistema CVDentUS utilizando potências variadas do aparelho de ultrassom. Quatro cavidades em forma de circunferência foram realizadas na face vestibular de 10 dentes incisivos bovinos, utilizando-se as pontas cilíndricas CVDentUS (n.82137) e diamantada convencional para alta rotação (n.1092). A amostra foi dividida em 4 grupos: G1 Alta rotação; G2 Ultrassom com potência de 30%; G3 Ultrassom com potência de 60%; G4 Ultrassom com potência de 90%. Os preparos realizados foram padronizados medindo aproximadamente 2 mm de diâmetro e 4 mm de profundidade. Os preparos foram examinados em MEV, o que possibilitou avaliar o ângulo cavossuperficial de cada preparo. Cada preparo foi registrado por meio de fotomoicrografias para serem analisados no programa computadorizado Image pró-plus, que permitiu quantificar a área irregular de cada preparo. Os resultados foram analisados com ANOVA (p< 0,00003), verificando-se a significância estatística entre os fatores, foi aplicado o teste de Tukey que demonstrou haver diferenças na área das irregularidades dos preparos avaliados. Com base na metodologia empregada pôde-se concluir que a definição do ângulo cavossuperficial sofre influência relativa em função do tipo de instrumentação, sendo que a instrumentação rotatóra demonstrou similaridade quanto a regularidade marginal dos preparos cavitários quando comparada com a instrumentação ultrassônica utilizada na faixa de 30% da potencia máxima do aparelho, no entanto quando utilizada nas outras potências avaliadas (60 e 90%) houve alterações mais significativas na definição marginal dos preparos cavitários / The aim of this study was to evaluated the definition of the cavosurface margin in cavity preparations made with a high speed dental handpieces (360.000 rpm) and with ultrasonic devices. Four cavities in the form of a circle were performed in a buccal surface of 10 bovine incisor teeth, using cylindrical tips CVDentUS (n.82137) for ultrasound and conventional cylindrical diamond bur (n.1092) for rotary instrumentation. The sample was divided into 4 groups: G1 - High speed, G2 - Ultrasound with power level of 30%, G3 - Ultrasound with power level of 60%, G4 - Ultrasound with power level of 90%. The preparations were standardized measuring approximately 2 mm in diameter and 4 mm in depth. The specimens were examined by SEM to evaluate the cavosurface margin of each preparation. The images were analyzed in a computer program, Image Pro-Plus 4.5, which allowed quantifying the irregular area of each preparation. The results were analyzed by ANOVA (p<0, 00003) showed statistically significant differences. The Tukey test pointed differences in the irregularities areas of the preparations. According to the methodology used, rotary instrumentation showed similarity, as the marginal regularity of dental cavities, compared to ultrasonic instrumentation used in the range of 30%. It was concluded that both instruments are effective for the realization of cavity preparations, however when the powers of 60 and 90% were used, cavity margins showed less defined.
42

Desmineralização do esmalte dental adjacente a restaurações. Efeito dos parâmetros do laser de Er:YAG empregado para o preparo cavitário / Enamel demineralization around dental restoration. Effect of Er:YAG laser parameters employed to cavity preparation

Colucci, Vivian 01 February 2010 (has links)
O presente estudo, composto por dois experimentos, teve como objetivo avaliar in vitro o efeito de parâmetros do laser de Er:YAG na desmineralização do esmalte dental humano e bovino após desafio cariogênico e avaliar, através de um modelo in situ, o efeito de diferentes parâmetros do laser de Er:YAG no desenvolvimento de lesões de cárie adjacente a restaurações. No estudo in vitro, terceiros molares inclusos humanos hígidos e incisivos bovinos foram seccionados para a seleção de 50 fragmentos de cada um dos substratos, que foram aleatoriamente divididos em 10 grupos, sendo 9 experimentais preparados com laser de Er:YAG com 300mJ de energia (frequência de 2Hz, 4Hz ou 6Hz, fluxo de água de 2,0mL/min, 5,0mL/min ou 8,0mL/min) e 1 controle (turbina de alta rotação). Após o preparo das cavidades, os espécimes foram restaurados com resina composta e submetidos ao desafio cariogênico. Subseqüentemente, foram seccionados para a análise da microdureza e realização de microscopia de luz polarizada qualitativa. No estudo in situ, 150 fragmentos de esmalte bovino foram distribuídos aleatoriamente entre 15 voluntários. Tais fragmentos foram subdivididos em 10 grupos conforme descrito para o estudo in vitro. Os 9 grupos experimentais foram preparados com laser de Er:YAG empregando-se diferentes combinações de parâmetros, conforme descrito pra o estudo in vitro. O grupo controle foi preparado com turbina de alta-rotação e ponta diamantada. A cavidade obtida foi restaurada com resina composta e os fragmentos foram montados em dispositivo palatino para serem instalados nos voluntários participantes para a realização do desafio cariogênico. Após o desafio, os espécimes foram seccionados para a realização das leituras de microdureza longitudinal e microscopia de luz polarizada qualitativa. Os dados obtidos no ensaio de microdureza foram analisados estatisticamente. Para o estudo in vitro foi realizada a Análise de variância e o teste de Tukey e observou-se que, independentemente do substrato testado, os espécimes preparados com turbina de alta rotação apresentaram menores médias de microdureza que os preparados com laser de Er:YAG para todos os parâmetros testados, os quais foram semelhantes entre si (p>0,05). As imagens de microscopia de luz polarizada demonstraram uma tendência dos grupos irradiados com laser de Er:YAG com uma freqüência de 2Hz apresentarem menor desmineralização. Para o estudo in situ foi realizado teste de Friedman que demonstrou haver diferença estatística entre os métodos de preparo cavitário empregados com relação as medidas de microdureza. Para identificar as diferenças entre os grupos foi realizado o teste de Wilcoxon pareado e observou-se que o grupo preparado com laser de Er:YAG com 2Hz de freqüência e 2mL/min de fluxo de água apresentou a maiores médias de microdureza, seguido por aqueles preparados com laser de Er:YAG com 2Hz de freqüência e 5mL/min de fluxo de água e laser de Er:YAG com 2Hz de freqüência e 8mL/min de fluxo de água, respectivamente. Os grupos preparados com laser de Er:YAG com as freqüências de 4Hz e 6Hz, com fluxos de água de 2, 5 e 8mL/min apresentaram médias de microdureza menores que os grupos supracitados e com similaridade estatística entre si. Todos os grupos preparados com laser de Er:YAG demonstraram médias de microdureza superiores àquele preparado com turbina de alta-rotação, o qual apresentou as menores médias de microdureza. As imagens de microscopia de luz polarizada confirmaram os resultados obtidos com o ensaio de microdureza. Assim, pode-se concluir que o substrato bovino constitui uma alternativa ao substrato humano em estudos que avaliem o laser de Er:YAG e a progressão de lesões de cárie, que o laser de Er:YAG foi capaz de controlar o desenvolvimento de lesões de cárie adjacente a restaurações de resina composta e que o conjunto de parâmetros empregados para o preparo cavitário pode influenciar na resistência ácida do substrato irradiado. / The current study, composed by two experiments, sought to evaluate in vitro the effect of Er:YAG laser parameters on human and bovine enamel demineralization after cariogenic challenges and to check, through an in situ model, the effect of different Er:YAG laser parameters on development of caries-like lesions adjacent to dental restorations. In the in vitro study, sound human third molars and bovine incisors were cut to select 50 specimens of each substrate, which were randomly allocated into 10 groups: 9 experimental groups prepared with Er:YAG laser with 300mJ output (frequency of 2Hz, 4Hz or 6Hz, water flow rate of 2.0mL/min, 5.0mL/min or 8.0mL/min) and 1 control group (High speed handpiece). After cavity preparation, the specimens were restored with composite resin and submitted to the cariogenic challenge. Afterwards, they were sectioned to obtain the microhardness measurements and images of light polarized microscopy. In the in situ study, 150 bovine enamel slabs were randomly allocated among 15 volunteers. These specimens were subdivided into 10 groups, as described above to the in vitro study. 9 experimental groups were prepared with Er:YAG laser under different parameters combination. The control group was prepared with high speed handpiece associated to a diamond bur. The prepared cavity was restored with a composite resin and the slabs were mounted on palatal appliance to be installed in the volunteers to the realization of the cariogenic challenge. After this, the specimens were sectioned to the longitudinal microhardness measurements and to the qualitative light polarized microscopy. The data obtained by means of microhardness test were statistically analyzed. For the in vitro study was performed Analisys of Variance and Tukeys test, which demonstrated that, regardless the tested substrate, the specimens prepared with high speed handpiece showed lower microhardness means than those prepared with the Er:YAG laser for all tested parameters, which were statistically similar (p>0,05). The light polarized microscopy images demonstrated that the groups irradiated with Er:YAG laser with 2Hz frequency showed a tendency to be less susceptible to the demineralization. For the in situ study was performed the Friedman test, which demonstrated that there are statistical difference among the cavity preparation methods according to the microhardness measurements. To indentify the differences among groups it was performed the Wilcoxon paread test and it was observed that the group prepared with Er:YAG laser with 2Hz of frequency and 2.0mL/min of water flow rate showed the highest microhardness means, followed by that prepared with Er:YAG laser with 2Hz of frequency and 5.0mL/min of water flow rate and Er:YAG laser with 2Hz of frequency and 8.0mL/min of water flow rate, respectively. The groups prepared with Er:YAG laser with 4Hz and 6Hz of frequency, with water flow rates of 2.0, 5.0 and 8.0mL/min showed microhardness means lower than that the groups cited above and statistical similarity among them. All groups prepared with Er:YAG laser demonstrated microhardness means higher than that prepared with high speed handpiece, what showed the lowest microhardness means. The light polarized microscopy images confirmed the results obtained with the microhardness test. Thus, it may be concluded that the bovine substrate constitutes an alternative to the human substrate in studies that evaluates the Er:YAG laser and caries-like lesions progression, that the Er:YAG laser was capable to control the development of caries-like lesions around composite resin restorations and that the parameters employed to the cavity preparation could influence on acid resistance of the irradiated substrate.
43

CVDentus® X micromotor na segunda infância: avaliação de aspectos técnicos, comportamentais e da agradabilidade / CVDentUS® x low speed handpiece in the 2nd childhood: evaluation of technical and behavioral aspects and pleasantness

Carvalho, Flávia Patto 09 May 2011 (has links)
O tratamento odontológico geralmente envolve ansiedade nos pacientes decorrente da vibração e ruído provocado pelos instrumentos rotatórios. A instrumentação ultrassônica é uma alternativa ao instrumento rotatório convencional, pois proporciona segurança e conforto ao paciente, além de execução simples e fácil. O presente estudo teve como objetivo comparar o uso de brocas convencionais usadas em micromotor (MM) com, pontas diamantadas CVDentus® no equipamento CVDent1000 (CVD) para remoção de tecido cariado e preparo cavitário em crianças, avaliando os aspectos técnicos das pontas, o comportamento das crianças e a agradabilidade dos equipamentos. Participaram 30 crianças de 36 a 71 meses, apresentando pelo menos dois molares decíduos com lesão de cárie oclusal ativa incipiente, ou com lesão questionável, em fossas e fissuras. A amostra foi subdividida em duas fases. Na fase 1, o CVD foi comparado ao MM sem refrigeração e, na fase 2, com o MM sob refrigeração. Este estudo seguiu o modelo split mouth, e o critério de escolha do dente e do equipamento usado na primeira criança foi aleatório, através de sorteios inicialmente e depois, programado para o equipamento. O tratamento foi realizado em uma única sessão, sem anestesia local, sob isolamento relativo, e os dentes restaurados com cimento de ionômero de vidro convencional. Os aspectos técnicos dos sistemas nas fases 1 e 2, avaliados pelo operador, incluíram os parâmetros visualização da área de trabalho (VAT), acesso á cavidade (AC), remoção do tecido cariado (RTC) e ruído e vibração (RV). O comportamento da criança (Cpt) também foi avaliado. As crianças avaliaram a agradabilidade dos equipamentos pela Escala Analógica Visual de Faces de McGrath (1990) Modificada, somente na fase 2. Na fase 1 houve diferença significantemente superior para o CVD nos critérios Cpt (p=0,0431), AC (p=0,0009) e RV (p=0,0006), sendo estes dois últimos também significantes na fase 2, com o mesmo valor de p (Teste de Mann-Whitney). Nos demais critérios, o MM foi superior apenas no RTC, mas não significante. O sistema CVD parece ser uma alternativa promissora. No entanto, são necessários outros estudos para esclarecer aspectos ainda não totalmente entendidos, para que a sua indicação e aplicação em odontopediatria sejam apoiadas por uma evidência científica consistente. / The dental treatment usually involves anxiety in patients due to vibration and noise caused by the rotary instruments. The ultrasonic instrumentation is an alternative to the conventional rotatory instrument, device as it provides security and comfort to the patients, beyond simple and easy execution. The objective of this study was to compare the use of conventional handpiece and drills versus diamond burs CVDentus® system CVDent1000® equipment (CVD) for caries removal and cavity preparation in children, evaluating their clinical performance, behavior children and the pleasantness of the equipment. The sample was composed by 30 children from 36 to 71 months, with at least two primary molars with occlusal incipient active or questionable pits and fissures dental caries. The study was divided into two phases. In the phase one, the CVD was compared to HP without refrigeration, and in the phase two, with HP under refrigeration. This study followed a \"split mouth\" design, and the tooth and the equipment used for the first child were randomly selected by lottery at the beginning, then the selection was programmed for the equipment. The treatment was performed in a single session, without local anesthesia, under rubber dam isolation, and the teeth were restored with conventional glass ionomer cement. The clinical performance of the systems in the two phases was evaluated by the operator, and included the parameters working area view (WAV), access to the cavity (AC), removal of carious tissue (RCT) and noise and vibration (NV). The child\'s behavior (B) was also evaluated. Children rated the pleasantness of the equipment by the modified VAS Faces of McGrath (1990), only in phase 2. There was a higher and significant difference for CVD in the criteria B (p = 0.0431), AC (p = 0.0009) and NV (p = 0.0006). These last two criteria were also significant in phase 2, with the same p value (Mann-Whitney). For the other criteria, the MM was only superior in RCT, but not significant. The CVDentus® system seems to be a promising alternative. However, additional studies are necessary to clarify aspects that were not completely understood, so that its indication and application in pediatric dentistry being supported by consistent scientific evidence.
44

"Relação entre tensão de contração e grau de conversão em compósitos restauradores" / "Relationship between contraction stress and degree of conversion in dental composites"

Calheiros, Fernanda Calabró 06 June 2003 (has links)
RESUMO A tensão de contração desenvolvida durante a polimerização de um compósito aderido às paredes do preparo cavitário pode comprometer a integridade da interface dente/restauração. O objetivo deste trabalho foi verificar a relação entre a tensão de contração e o grau de conversão em compósitos híbridos (Z250 e Tetric Ceram) e microparticulados (A110 e Heliomolar). Para o teste de tensão de contração foram utilizados bastões de vidro de silicato de boro (Pyrex), com 5 mm de diâmetro e 5 cm de altura. Os bastões foram presos às garras de uma máquina de ensaios (modelo 5565, Instron, Canton, MA, EUA) e o compósito foi aplicado às superfícies planas do vidro, as quais passararam por jateamento com óxido de alumínio (250 mm), seguido de silanização e aplicação de adesivo. A distância entre as superfícies dos vidros foi ajustada em 2 mm (Fator C=1,25). O grau de conversão (GC) foi determinado através de espectroscopia fotoacústica no infravermelho (PAS-IR) utilizando-se as razões entre as bandas correspondentes às duplas ligações carbônicas alifáticas (1640 cm -1 ) e aromáticas (1610 cm -1 ). Para cada compósito, tanto no teste de tensão como na análise do grau de conversão, foram constituídos cinco grupos variando-se o tempo de irradiação, a fim de se obter diferentes níveis de densidade de energia (4,8; 13,5; 27,0; 54,0 e 108,0 J/cm 2 ). Foram registrados os valores de tensão máxima e de grau de conversão observados no período de 10 minutos, contados a partir do início da fotoativação. A análise de dados foi feita através de ANOVA de fator duplo e teste de Tukey (a=0,05). Para os valores de tensão de contração, a interação compósito x densidade de energia foi significante. Os valores de tensão de contração para o compósito A110 variaram entre 1,2 e 7,0 MPa, para o Heliomolar entre 0,6 e 6,6 MPa, para o compósito Tetric Ceram entre 1,3 e 8,1 MPa e para o Z250 entre 2,0 e 6,6 MPa. Em geral, valores de tensão maiores foram observados nos níveis de densidade de energia mais elevados. Para o compósito A110 4,8<13,5<27,0<54,0=108,0 J/cm 2 . Para o compósito Heliomolar todos os níveis foram diferentes exceto entre 27,0 e 54,0 J/cm 2 . O compósito Tetric Ceram apresentou 4,8<13,5<27,0<54,0=108,0 J/cm 2 enquanto o compósito Z250 obteve 4,8=13,5<27,0=54,0<108,0 J/cm 2 . O GC foi influenciado pelo compósito (A110: 24% = Heliomolar: 28% = Z250: 32% < Tetric: 39%) e pela densidade de energia. As densidades de energia de 27,0 (33%); 54,0 (35%) e 108,0 (36%) J/cm 2 forneceram graus de conversão estatisticamente semelhantes, o mesmo ocorrendo entre 4,8 (23%) e 13,5 (26%) J/cm 2 e entre 13,5 e 27,0 J/cm 2 . Os resultados mostraram ainda que existe uma relação não-linear entre a tensão de contração e o grau de conversão de compósitos restauradores. Pode-se concluir que densidades de energia elevadas não necessariamente contribuem para um aumento significante no GC, mas podem acentuar o desenvolvimento de tensões de contração. / ABSTRACT The contraction stress developed during polymerization of composites bonded to cavity walls cavity is often associated with marginal gaps and interfacial failure. The aim of this study was to verify the relationship between contraction stress and degree of conversion (DC) in four composites (Z250, A110 – 3M ESPE; Tetric Ceram, Heliomolar – Vivadent). For the contraction stress test, composite (2 mm thick) was bonded between sandblasted and silane-treated glass stubs (Pirex: 5 mm diameter), mounted in a testing machine (model 5565, Instron, Canton, MA, EUA) equipped with a tensilometer to monitor the distance between the rods (C-factor=1.25). DC was determined by Infrared Photoacustic spectrometry (PAS-IR). The ratio between the aliphatic (1640 cm -1 ) and the aromatic (1610 cm -1 ) carbon double-bonds was used for calculating the DC. In both tests, each composite was light-cured for different times in order to provide different energy densities (4.8, 13.5, 27.0, 54.0, 108.0 J/cm 2 ). Maximum contraction stress and DC were measured 10 minutes after the beginning of polymerization. Results were analyzed by two-way ANOVA and Tukey’s test (a=0.05). For contraction stress, the interaction between composite and energy density was significant. Contraction stress values for A110 were between 1,2 and 7,0 MPa, Heliomolar between 0,6 and 6,6 MPa, Tetric Ceram between 1,3 and 8,1 Mpa and Z250 between 2,0 and 6,6 MPa. In general, contraction stress increases with higher energy density levels. For A110, 4.8<13.5<27.0<54.0=108.0 J/cm 2 . Heliomolar showed significant differences between all energy densities, except 27.0 and 54.0 J/cm 2 . Tetric was 4.8<13.5<27.0<54.0=108.0 J/cm 2 and Z250 showed 4.8=13.5<27.0=54.0<108.0 J/cm 2 . DC was influenced by composite (A110: 24%;Heliomolar: 28%, Z250: 32%; Tetric: 39%) and by energy density. The 27.0 (33%), 54.0 (35%) and 108.0 (36%) J/cm 2 energy densities showed similar DC, the same occurring with 4.8 (23%) and 13.5 (26%) J/cm 2 and between 13.5 and 27.0 J/cm 2 .The results showed a non-linear relationship between contraction stress and degree of conversion. It can be concluded that higher energy densities will not necessary contribute to increase DC, but may result in increased contraction stress development.
45

Estudo de preparos e da forma da infraestrutura na distribuição de tensões em prótese parcial fixa /

Yamamoto, Eron Toshio Colauto. January 2011 (has links)
Resumo: O objetivo do estudo foi verificar o comportamento de prótese fixa de três elementos confeccionada em Zircônia e dos dentes suportes quando são utilizados diferentes preparos dos dentes suportes e diferentes formas da infra-estrutura. Simulou-se a ausência do segundo pré-molar superior e realizou-se preparos do tipo ocluso-proximal, proximal-ocluso-proximal, preparo para overlay e para coroa total nos dentes suportes. Utilizou-se dois tipos de formato de conector, o convencional e em forma de arco. Os modelos tridimensionais foram realizados em softwares CAD Rhinoceros® e 3D Studio Max®. Os modelos tridimensionais simularam uma secção da maxila na região entre primeiro pré-molar e primeiro molar e foram compostos por osso medular e cortical, ligamento periodontal, dentina e esmalte. Foi realizada análise de elementos finitos, as análises de tensões foram processadas no programa Ansys®. Os resultados foram apresentados por meio de mapas de cores de tensão/deformação, com a distribuição de tensões e valores numéricos. Os diferentes preparos dos dentes suportes não influenciaram na distribuição de tensões nos dentes suportes. O preparo de coroa total foi o único preparo que diminui a tensão sobre a infra-estrutura. O formato do conector foi significativamente diferente. O conector em forma de arco distribui melhor as tensões na infra-estrutura do que o conector convencional / Abstract: The aim of this study was to investigate the behavior of three elements fixed partial denture made of three elements made of Zirconia and support teeth when use different preparations of the support teeth and different forms of framework. Simulated the absence of the superior second premolar and the support teeth preparation was occlusal-proximal, proximal-occlusal-proximal, overlay preparation and full crown. We used two types of connector format, the conventional and arc-shaped. The three-dimensional models were made in Rhinoceros CAD software and 3D Studio Max. The model was composed with maxillary first premolar and first molar, cortical and medullary bone, periodontal ligament, dentin and enamel. Analyses of stresses were processed in the program ANSYS ®. The results were presented in color maps of stress / strain, with the stress distribution and numerical values. The different preparations of the support teeth didn't influence the stress distribution in supppot teeth. The preparation of full crown was the only preparation that reduces the strain on the infrastructure. The shape of the connector was significantly different. The arch-shaped connector was better than conventional connector in the framework stress distribution / Orientador: Clóvis Pagani / Coorientador: Eduardo Galera da Silva / Banca: Eduardo Shigueyuki Uemura / Banca: Rubens Corte Real de Carvalho / Banca: Pedro Yoshito Noritomi / Banca: Daniel Maranha da Rocha / Doutor
46

Avaliação da qualidade de margem de preparos cavitários realizados com diferentes técnicas e instrumentos / Margin quality of cavity preparations with different techniques and instruments

Francischone, Ana Carolina 11 September 2009 (has links)
Há mais de 50 anos, a Odontologia usa a mesma tecnologia para a preparação de cavidades, que é a alta velocidade com ponta diamantada e brocas carbides. Novos estudos e novas técnicas têm sido proporcionada para que haja uma opção a mais para esse procedimento no tratamento para os pacientes. Surgiram, então, novas tecnologias no mercado odontológico para eliminação mecânica da cárie e preparação de cavidades, como alta pressão de ar associado a jato de areia, aparelho de Laser, contra- ângulo multiplicador e ultrassom associado a pontas diamantadas. Mas por serem tecnologias novas, há ainda necessidade de pesquisas para a constatação de que realmente poderão vir a ser técnicas alternativas ou até substituir a tecnologia clássica que vem sendo utilizada com bons resultados. Assim, o propósito desta pesquisa foi avaliar, através de microscopia eletrônica de varredura (MEV), as margens cavitárias com e sem acabamento, realizadas com pontas diamantadas e CVDentus, associadas a diferentes tipos de dispositivos e mecanismo de ação. Os resultados encontrados mostraram não haver diferenças estatisticamente significantes (p<0.05) entre as condições testadas, nas comparações individuais, com exceção dos grupos G4 x G7 (Alta velocidade+ Ponta Diamantada Preparo + Baixa Rotação + Ponta Diamantada para acabamento x Ultrassom + CVDentus Preparo 50% + Contra-ângulo). Concluiu-se que todas as formas de acabamento das margens cavitárias, testadas nesta pesquisa, são confiáveis e podem ser utilizadas. O uso do aparelho de ultrassom deve ser recomendado nas potências variando entre 50% a 75% para preparos cavitários. / For more than 40 years, dentistry has used the same technology for cavity preparation, high-speed rotation systems with diamond burs. New studies and techniques have been performed to develop a new treatment option for patients. Thus, new technologies have been possible such as high pressure sandblasting systems, laser devices, multiplying low-speed rotation, and finally, the ultra-sound with diamond burs. However, whether these new technologies can be an alternative or substitute for old practices with standard results is not known. The aim of this study was to evaluate by SEM cavity preparation margins with and without finishing, made by diamond burs and the CVDentus system associated to different devices and action forms. The results showed no statistically significant differences (p<.05) among the tested conditions on individual comparisons, except for GIV x GVII (highspeed rotation plus diamond bur + low-speed rotation plus diamond finishing bur x ultra-sound plus CVDentus 50% power plus low-speed rotation). It was concluded that all finishing modes on margin cavities are reliable and can be used in clinical practice. The use of the ultra-sound device can be recommended within 50-75% power for cavity preparations.
47

Efetividade de diferentes mÃtodos mecÃnicos de remoÃÃo de dentina cariada: avaliÃÃo atravÃs de micro-CT e imagem digital / Effectiveness of different mechanical methods on dentin caries removal: micro-CT and digital image evaluation

Camila de AtaÃde e Ferraz 28 February 2013 (has links)
FundaÃÃo de Amparo à Pesquisa do Estado do Cearà / CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / A remoÃÃo seletiva de dentina cariada à um desafio para a Odontologia contemporÃnea, jà que os mÃtodos tradicionais de escavaÃÃo podem remover, alÃm do tecido cariado, dentina sadia. Objetivou-se determinar a efetividade de remoÃÃo de cÃrie (ERC) e o potencial minimamente invasivo (PMI) de trÃs mÃtodos mecÃnicos de escavaÃÃo. Doze molares humanos com lesÃes de cÃrie oclusal em dentina foram distribuÃdos, de forma randomizada, em trÃs grupos de acordo com o mÃtodo de remoÃÃo: broca carbide, cureta de dentina e broca de polÃmero. Todos os dentes, antes de serem submetidos à etapa de escavaÃÃo da cÃrie, tiveram suas raÃzes embutidas em resina acrÃlica. Seccionaram-se os dentes uma Ãnica vez no sentido longitudinal, tendo como referÃncia visual o centro da lesÃo. Cada uma das secÃÃes foi submetida a fotografias digitais padronizadas e escaneamento por microtomografia computadorizada de raios-X (micro-CT) (Skyscan 1174, Skyscan, Kontich, Belgium) em dois momentos distintos, antes e apÃs a remoÃÃo de cÃrie. Utilizou-se um programa de imagens de domÃnio pÃblico, ImageJ, para anÃlise das imagens obtidas. Definiram-se as Ãreas de dentina cariada inicial (CI), da cavidade preparada (CP) e da cÃrie residual (CR) nas fotografias e nas imagens de micro-CT de acordo com critÃrio visual. Determinou-se a ERC entre os mÃtodos com base na relaÃÃo CR/CI, enquanto o PMI foi determinado atravÃs da relaÃÃo entre CP/CI. Analisaram-se os dados obtidos atravÃs de AnÃlise de VariÃncia a Um CritÃrio e teste-t de Student ou Kruskal-Wallis e teste Student-Newman-Keuls. Tanto para a anÃlise de imagem digital quanto para a anÃlise de micro-CT, a broca carbide apresentou maior efetividade em relaÃÃo à cureta (p=0,0063; p=0,0263, respectivamente) e em relaÃÃo à broca de polÃmero (p=0,0028; p=0,0005, respectivamente), enquanto que cureta de dentina e broca de polÃmero mostraram resultados semelhantes para os dois tipos de imagens (p>0,05). Em relaÃÃo ao PMI, para a anÃlise de imagem digital, a broca de polÃmero apresentou-se como mÃtodo com potencial invasivo similar à cureta de dentina (p=0.1240), porÃm com invasividade menor do que a broca carbide (p=0,0028). Para a anÃlise de micro-CT, os valores de PMI de todos os grupos foram significantemente diferentes, e a broca de polÃmero tambÃm demonstrou o mÃtodo mais conservador, tanto em relaÃÃo à cureta de dentina (p=0,0030), quanto em relaÃÃo à broca carbide (p<0.001). Portanto, a broca carbide foi o mÃtodo mais efetivo para remoÃÃo de cÃrie, porÃm o menos conservador; e a broca de polÃmero apresentou baixo potencial invasivo, porÃm nÃo foi capaz de remover toda a dentina cariada.
48

Enhancement of bonding to enamel and dentin prepared by Er,Cr:YSGG Laser

Obeidi, Ali. January 2008 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2008. / Title from PDF title page (viewed on Feb. 3, 2010). Includes bibliographical references (p. 52-57).
49

In vitro evaluation of bacterial penetration around varnish-lined amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Vonk, James D. January 1969 (has links)
Thesis (M.S.)--University of Michigan, 1969.
50

The resistance of cavity bases and a cavity liner upon thermal conduction by amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Hayakawa, James K. January 1968 (has links)
Thesis (M.S.)--University of Michigan, 1968.

Page generated in 0.1645 seconds