• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Metodjämförelse mellan DiffMaster Octavia och CellaVision DM1200 avseende differentialräkning av leukocyter : en viktig analys inom vården

Ölje, Elin January 2016 (has links)
Leukocyter, vita blodkroppar, utgör en del av kroppens immunförsvar. De utmognar från hematopoetiska stamceller i benmärgen. Leukocyterna kan delas in i neutrofila granulocyter, lymfocyter, monocyter, eosinofila granulocyter och basofila granulocyter. För att bestämma antalet leukocyter i blodet analyseras leukocytpartikelkoncentration (B-LPK) med cellräknare. Om B-LPK är förhöjt eller sänkt utförs en differentialräkning av leukocyter (B-Diff) för att se i vilket cellsystem förändring föreligger. Den manuella analysen utförs på perifera blodutstryk färgade med cytokemisk färg, May-Grünwald Giemsa. Utstryket granskas i ett automatiskt mikroskopiskt system som räknar, fotograferar och förklassificerar leukocyter efter deras utseende. DiffMaster Octavia och CellaVision DM1200 är två varianter av ett sådant instrument från samma tillverkare (CellaVision AB, Lund, Sverige). Syftet med studien var att utföra en metodjämförelse mellan dessa instrument genom analys av 60 patientprov bestående av venöst blod taget i EDTA-rör. Proven samlades in slumpmässigt från patienter (32 män och 28 kvinnor) mellan 19-95 år. Resultaten visade enligt tvåsidigt parat t-test ingen signifikant skillnad avseende differentialräkning av neutrofila granulocyter, lymfocyter och monocyter. Korrelationen var 0,95, 0,91 respektive 0,68. Det fanns dock en signifikant skillnad mellan instrumenten avseende differentialräkning av eosinofila- och basofila granulocyter, korrelationen var 0,91 respektive 0,20. När endast 200 celler räknas kan ett resultat på 2 % skilja upp till 1-5 %. Därför blir skillnader på leukocyttyper som utgör enstaka procent i blodet normalt mycket stora. Metodjämförelsen visade att båda instrumenten ger samma resultat och anses därför likvärdiga vid analys av manuell B-Diff. / Leukocytes, white blood cells, are cells of the immune system. They are produced and derived from hematopoietic stem cells in the bone marrow. Leukocytes can be divided into neutrophils, lymphocytes, monocytes, eosinophils and basophils. To determine the numbers of leukocytes in blood the leukocyte particle concentration (B-LPK) can be analyzed by cell counters. When B-LPK is elevated or lowered a differential count of leukocytes (B-Diff) is performed to see in which cell systems the change exists. The manual analysis involves peripheral blood smears stained with a cytochemical color, May-Grünwald Giemsa. The smear examined in an automatic microscopically system that counts, photographs and pre-classify leukocytes by its appearance. DiffMaster Octavia and CellaVision DM1200 are two variants of such instruments from the same manufacturer (CellaVision AB, Lund, Sweden). The aim of the study was to do a comparison between these instruments by analyzing 60 samples consisting venous blood in EDTA-tubes. The samples were collected randomly from patients (32 men and 28 women) between 19-95 years old. The results from two-sided paired t-test showed no significant difference between the differential count of neutrophils, lymphocytes and monocytes. The correlation was 0,95, 0,91 and 0,68. However, there was a significant difference between the instruments differential count of eosinophils and basophils, the correlation was 0,91 and 0,20. When counting only 200 cells a profit of 2 % distinguish up to 1-5 %. Abnormalities in leukocytes which represents only a few percent in blood can therefore be very large. Method comparison showed that both instruments give the same results and are considered equivalent in analysis of manual B-Diff.
2

Hur påverkas CellaVision DM1200:s förklassificering av leukocyternas infärgning?

Andersson, Lina January 2015 (has links)
Sammansättningen av leukocyter i perifert blod varierar med olika sjukdomstillstånd och analys av cellerna är avgörande vid diagnostisering och uppföljning av olika leukemier.  Manuell mikroskopering och utvärdering av leukocyterna är tidskrävande och inte alltid självklar eftersom det krävs personal med hög kompetens och erfarenhet för bedömning av cellerna. En tillförlitlig förklassificering av den manuella differentialräknaren CellaVision DM1200 är därför av stort intresse för att underlätta kvantifiering och klassificering av cellerna. För att se om instrumentets förklassificering påverkades av infärgningen undersöktes färglösningens inverkan genom ändringar i fosfatbuffertens pH. Blodutstryk som härstammade från 10 patientprov färgades in med buffertar med pH 6.0, 6.8 och 7.5. Studien visade på en god positiv korrelation i samtliga pH-justerade buffertar, men med bäst resultat för pH 6.0 och 6.8. CellaVision DM1200:s förklassificering av eosinofila granulocyter påverkades mest av pH ändringar, vilket kan förklaras av deras starkt acidofila granula. / In peripheral blood the composition of leukocytes vary due to diseases and therefore analysis of the cells is critical in diagnosing and monitoring various leukemias. Manual microscopy and evaluation of the leukocytes is time consuming and not always clear, and it requires educated staff with long experience to assess the cells. A reliable automatic pre-classification of the cells with the system CellaVision DM12000 is therefor of great interest to facilitate quantification and classification of leukocytes. To evaluate if the instrument’s pre-classification were affected by staining, changes of the current staining solution used in clinical assessment where made by adjustment of the phosphate buffer pH. Examined blood smears that were descendent from 10 different samples were stained in buffers with pH 6.0, 6.8 and 7.5. This study showed a high positive correlation in all of the pH-adjusted buffers with the best results in pH 6.0 and 6.8. CellaVision DM1200’s pre-classification of eosinophilic granulocytes were most affected by changes in pH, which can be explained by their strongly acidophilic granules.

Page generated in 0.05 seconds