• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analyse numérique de résultats expérimentaux dans le but d'établir la perméabilité intrinsèque de matériaux d'enrochement

Dhyser, Yann 19 April 2018 (has links)
Le transfert de chaleur dans les sols est généralement gouverné par la conduction. Cependant, dans les matériaux d’enrochement, la taille des pores est suffisamment grande pour permettre le mouvement de l’air soit par un gradient de pression (convection forcée) ou par un gradient de température (convection naturelle). Il a été montré dans de précédentes études que la convection influence grandement le transfert thermique dans les enrochements d’ouvrages de génie civil tels que les routes, les voies ferrées ainsi que les remblais de barrages construits dans les régions froides (Goering et Kumar, 1996 ; Saboundjian et Goering, 2003 ; Konrad et al., 2006). Le paramètre qui influence le plus la convection est la perméabilité intrinsèque du matériau. Au cours de recherches précédentes, Côté et Fillion (Fillion, 2008 ; Côté et al., 2011b) ont mis au point une cellule de test où les conditions permettant la convection naturelle ont été appliquées à un échantillon de matériau de 1 m3, dans le but de mesurer sa perméabilité intrinsèque. L’analyse des résultats expérimentaux a été faite en utilisant une relation analytique entre les nombres de Nusselt (Nu) et de Rayleigh (Ra), relation basée sur les résultats de Schubert et Strauss (1979) et valide pour une cellule imperméable et aux parois adiabatiques. En comparant les résultats avec les valeurs issues de modèles théoriques, un biais a été mis en évidence. Biais qui aurait pu être causé par la relation analytique utilisée et qui ne serait pas adaptée au montage expérimental dont le comportement n’est pas adiabatique. Dans ce mémoire, les transferts de chaleur à l’intérieur de la cellule expérimentale sont recréés en utilisant une modélisation numérique par éléments finis de la cellule expérimentale. Une nouvelle relation entre les nombres de Nusselt et de Rayleigh adaptée à la cellule est établie et les résultats expérimentaux de Fillion (2008) sont ensuite ré-analysés avec cette nouvelle relation. Les nouvelles mesures de la perméabilité intrinsèque sont ensuite comparées en fonction du modèle utilisé avec les résultats obtenus expérimentalement par Fillion (2008) et par les relations théoriques.
2

Development of design tools for convection mitigation techniques to preserve permafrost under northern transportation infrastructure

Kong, Xiangbing 08 January 2020 (has links)
Les infrastructures de transport jouent un rôle majeur dans le développement socio-économique des régions nordiques. La construction de remblais combinés aux changements climatiques engendrent des impacts négatifs sur le pergélisol sous-jacent, causant la dégradation des infrastructures. Des techniques de mitigation ont été proposées et testées pour limiter la dégradation du pergélisol. Toutefois, il y a peu d'informations disponibles sur les procédures de conception ou sur des lignes directrices. Le but de cette recherche est de développer des outils d'ingénierie améliorés pour les techniques de stabilisation convectives, se concentrant sur le remblai à convection d'air (ACE) et le drain thermique. Plus spécifiquement, l'approche du bilan thermique est proposée pour déterminer la condition thermique de remblais conventionnels et pour permettre la sélection de la technique de mitigation la plus appropriée pour extraire la chaleur en excès transmise au sol, si le système est actuellement instable, ou pour donner un facteur de sécurité considérant une instabilité future estimée. Quatre modèles thermiques ont été développés et calibrés à partir de données mesurées sur des sites expérimentaux. Un abaque de bilan thermique pour les remblais conventionnels ainsi que plusieurs abaques de capacité d'extraction de chaleur pour l'ACE et le drain thermique ont été développés et validés utilisant, respectivement, des simulations numériques et les données de sites d'essais du Yukon et du Nord du Québec, Canada. Ces abaques permettent aux concepteurs et ingénieurs de concevoir des remblais à convection d'air et des drains thermiques optimisés pour limiter, ou même éviter, le dégel du pergélisol à des sites spécifiques. / Transportation infrastructure plays a vital role in the social and economic development of northern regions. The construction of embankments and climate change can lead to negative impacts on the underlying permafrost, causing degradation of the infrastructure. Mitigation techniques have been proposed and tested to limit permafrost degradation. However, there is limited information on the design procedures or guidelines. The purpose of this research is to develop improved engineering tools for convective stabilization techniques, focussing on air convection embankment (ACE) and heat drain. More specifically, the heat balance approach is proposed to determine the thermal condition of conventional embankments and to allow the selection of suitable mitigation techniques to extract the amount of extra heat flowing into the foundation, if the system is currently unstable, or give a safety factor considering estimated future instability. Four thermal models have been built and calibrated with field data from experimental sites. One heat balance chart for conventional embankments and, several heat extraction capacity charts for ACE and heat drain have been developed using numerical simulations and have been validated using data from test sites in Yukon and Northern Quebec, Canada. These charts allow designers and engineers to design optimized ACE and heat drain to limit or even avoid the thawing of permafrost at specific sites.
3

Modélisation des phénomènes convectifs lors du changement de phase solide-liquide par utilisation de l'équation de diffusion de la chaleur et d'une forme modifiée de la conductivité

Vidalain, Guillaume 12 April 2018 (has links)
Dans ce mémoire on s'intéresse à la modélisation du changement de phase solide-liquide en convection naturelle et en convection forcée en utilisant l'équation de diffusion de la chaleur et une forme modifiée de la conductivité. Comme on ne cherche pas à résoudre le champ des vitesses, on intègre à l'intérieur de la conductivité modifiée les effets thermiques des mouvements convectifs, puis on résout l'équation de conduction en utilisant ces conductivités modifiées. L'objectif du mémoire est de prédire la position de l'interface solide-liquide en fonction du temps dans un processus de fusion ou de solidification en présence de convection, et ce avec un modèle conductif. Dans les deux cas types que nous avons traités, la valeur de la conductivité modifiée à utiliser dans le modèle conductif simplifié est d'abord estimée par une étude d'ordre de grandeur. Le premier cas type étudié est celui du changement de phase en présence de convection forcée se déroulant dans une conduite à paroi froide. On a réussi à développer une relation permettant d'obtenir la valeur de la conductivité modifiée directionnelle à utiliser dans le modèle conductif en fonction du nombre de Reynolds de l'écoulement ainsi que du facteur de forme de la conduite. Cette relation a montré de bons résultats en comparaison avec ceux issus d'un modèle numérique complet plus classique (CFD). Le deuxième cas type étudié est celui de la fusion d'un matériau sous l'effet de la convection naturelle à l'intérieur d'une enceinte. Nous avons réussi à paramétrer l'évolution des valeurs de conductivité modifiée à utiliser par notre modèle conductif, celles-ci sont fonction de l'avancement du front de fusion et du nombre de Nusselt. Cette modélisation est comparée à la fois avec les résultats fournis par un modèle numérique complet (CFD) mais aussi avec des résultats expérimentaux issus de la littérature. Ces comparaisons ont montré une bonne concordance entre notre modélisation et la réalité. / In this work we have developed an enhanced conduction model for predicting solid-liquid interface positions in convection-dominated phase-change processus. The flow field is not calculated and the effects of convection are taken into account via the modification of the material conductivity. Our objective is to obtain a good approximation of the solid-liquid interface evolution. It is shown that the enhanced thermal conductivity of the melt may be formulated in terms of directional thermal conductivity components and that their value may be correlated in terms of dimensional numbers obtained from an order of magnitude analysis. The proposed approach is then tested for two different cases. The first test case is devoted to forced convection dominated solidification in a duct while the second test case is concerned with buoyancy dominated melting in an enclosure. The results of the simulations using our conduction model are then compared with a full CFD model and in the case of melting in an enclosure experimental data, they show good agreements.

Page generated in 0.1302 seconds