• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optimization of design and operation of synergetic heating and cooling networks based on the energy hub concept

Ahmadisedigh, Hossein 13 December 2023 (has links)
Dans le présent travail, un modèle de « hub énergétique » a été utilisé pour concevoir des réseaux combinés de chauffage et de refroidissement afin de bénéficier des synergies potentielles. Les réseaux de chauffage et de refroidissement font partie intégrante de divers bâtiments, campus ou villes. Le concept de réseau thermique intelligent et de « hub énergétique » plaide en faveur de l'intégration thermique pour bénéficier des synergies potentielles et faciliter l'utilisation des sources d'énergie renouvelables. Dans ce système intégré, les pompes à chaleur peuvent être utilisées pour récupérer la chaleur de la boucle de refroidissement et la fournir à la boucle de chauffage. La récupération de la chaleur résiduelle peut aider à réduire les coûts d'exploitation et les émissions de gaz à effet de serre. Les charges de chauffage et de refroidissement du réseau peuvent être satisfaites par des chaudières au gaz naturel, des radiateurs électriques, des refroidisseurs et des pompes à chaleur. La conception du système et son fonctionnement ont été optimisés en termes de coût et d'émissions de gaz à effet de serre sous différentes combinaisons de charges de chauffage et de refroidissement. Les configurations de hub optimisées pour les scénarios avec et sans récupération de chaleur perdue ont été comparées, montrant que les pompes à chaleur étaient bénéfiques dans tous les scénarios. La capacité optimale des pompes à chaleur pour minimiser le coût total s'est avérée être d'environ 80% de la valeur maximale possible à partir d'une analyse thermodynamique des charges. La minimisation simultanée des coûts et des émissions a révélé une transition relativement nette du chauffage au gaz au chauffage électrique, car l'accent est davantage mis sur les émissions que sur les coûts, mais dans tous les cas, la récupération de la chaleur perdue avec des pompes à chaleur a été largement utilisée pour satisfaire les charges de chauffage et de refroidissement. Ensuite, en gardant le même cadre conçu ci-dessus, une méthode a été développée pour indiquer comment les unités de stockage d'énergie thermique (SET) peuvent contribuer à réduire le coût total d'un réseau thermique. Nous avons développé une méthode montrant comment les unités SET, couplées à des pompes à chaleur, peuvent contribuer à réduire le coût total d'un réseau thermique. Un modèle d'optimisation est introduit, basé sur un modèle de hub énergétique comprenant des chaudières au gaz naturel, des radiateurs électriques et des refroidisseurs. Pour différents profils de charge, les réseaux thermiques intégrant des pompes à chaleur seules, SET seules ou une combinaison des deux sont comparés à un hub de référence sans intégration thermique. Il a été constaté que l'inclusion à la fois du SET et des pompes à chaleur génère plus de bénéfices que lorsqu'elles sont utilisées séparément, étendant l'utilisation synergique des pompes à chaleur pour satisfaire à la fois les charges de chauffage et de refroidissement. De plus, l'intérêt du SET lorsque les composants du système(refroidisseur ou chaudière) sont sous-dimensionnés est évalué. Il a été observé que dans ces cas, le SET contribue à satisfaire les demandes thermiques. Cependant, en raison de la configuration du système, il existe une limite de sous-dimensionnement du refroidisseur que les unités SET peuvent compenser. Ensuite, l'influence du fonctionnement à charge partielle des dispositifs du hub énergétique a été étudiée pour le même hub énergétique. Dans la pratique, l'efficacité à charge partielle des équipements tels que les refroidisseurs, les chaudières et les pompes à chaleur doit être prise en compte dans la conception et le contrôle des réseaux de chauffage et de refroidissement car elle peut fortement affecter leurs performances globales. Cependant, les modèles d'optimisation tels que les hubs énergétiques considèrent généralement des efficacités constantes en raison du défi de mettre en œuvre l'efficacité à charge partielle dans de tels modèles. Par conséquent, l'impact des courbes d'efficacité à charge partielle sur les résultats d'optimisation des hubs énergétiques n'est souvent pas clair, en particulier lorsque plusieurs appareils sont inclus. Dans ce travail, le coût total sur la vie d'un système de réseaux combinés de chauffage et de refroidissement a été optimisé sur la base d'un hub énergétique dans lequel des dispositifs d'efficacité à charge partielle (chaudières à gaz naturel, radiateurs électriques, refroidisseurs électriques et pompes à chaleur) ont été modélisés. Le modèle a été linéarisé et étudié sous différentes combinaisons de charges thermiques. Une méthode itérative a été développée pour optimiser la conception et l'exploitation du pôle énergétique dans ce contexte. Pour déterminer l'impact des efficacités à charge partielle, chaque appareil a été examiné individuellement tandis que l'efficacité des autres appareils est restée constante. L'erreur résultant de l'hypothèse d'un rendement constant a ensuite été calculée sur la base d'un hub de référence avec des rendements constants. Les résultats ont indiqué une erreur maximale sur le coût total de 1,85 %, 0,6 % et 0,16 % en supposant un rendement constant pour les chaudières, les refroidisseurs et les pompes à chaleur respectivement. Les charges pour lesquelles ces erreurs maximales se produisent ont ensuite été choisies pour optimiser le hub avec tous les appareils modélisés avec une courbe d'efficacité à charge partielle. Les erreurs ont augmenté à 1,9 %, 0,71 % et 1.49 %, respectivement. Enfin, le potentiel de récupération de chaleur perdue (WHR) d'un atelier de fabrication a été évalué. Dans un premier temps, les sources de chaleur résiduelle ont été identifiées et évaluées, ce qui a conduit à la préparation d'une carte de chaleur résiduelle pour l'entreprise. Par la suite, trois principales méthodes de récupération de la chaleur ont été choisies et analysées pour l'usine. Pour les étés, la possibilité de remplacer les refroidisseurs actuels de bureaux par un refroidisseur à absorption simple effet de 52 kW a été étudiée, ce qui coûterait 8,000 CAD de plus que les refroidisseurs actuels sur 20 ans. Pour les hivers, le flux de chaleur résiduelle conditionné peut être utilisé à des fins de chauffage local au lieu d'utiliser les systèmes de chauffage électrique actuellement utilisés, ce qui permettrait d'économiser environ 110,000 CAD sur 20 ans. Pour le reste de l'année, la consommation interne d'eau chaude de l'entreprise peut être fournie en utilisant un chauffe-eau hybride (WHR+ électricité), ce qui permettrait d'économiser environ 2,000 CAD sur la même période. / In the present work, an "energy hub" template was employed to design combined heating and cooling networks to benefit from potential synergies. Heating and cooling networks are integral components of various buildings, campuses, or cities. The concept of smart thermal grid and "energy hub" argue in favor of thermal integration to benefit from potential synergies and facilitate the use of renewable energy sources. In this integrated system, heat pumps can be used to recover heat from the cooling loop and supply it to the heating loop. Waste heat recovery can help reducing operation costs and greenhouse gas emissions. Heating and cooling loads of the network can be satisfied by natural gas boilers, electric heaters, chillers, and heat pumps. The design of the system and its operation were optimized with respect to cost and greenhouse gas emissions under different combinations of heating and cooling loads. The optimized hub configurations for scenarios with and without waste heat recovery were compared, showing that heat pumps were beneficial in all scenarios. The optimal capacity of heat pumps to minimize total cost was found to be ~80% of the maximal possible value from a thermodynamic analysis of the loads. The simultaneous minimization of cost and emissions revealed a relatively sharp transition from gas to electric heating as more emphasis is put on emissions than cost, but in all cases, waste heat recovery with heat pumps was heavily used to satisfy the heating and cooling loads. Next, keeping the same framework designed above, a method was developed to indicate how thermal energy storage (TES) units can contribute to reduce the total cost of a thermal grid. We developed a method showing how TES units, coupled with heat pumps, can contribute to reducing the total cost of a thermal grid. An optimization model is introduced, based on an energy hub model including natural gas boilers, electric heaters, and chillers. For different load profiles, thermal grids integrating heat pumps alone, TES alone, or a combination of both are compared to a reference hub with no thermal integration. It was found that the inclusion of both TES and heat pumps together results in more profits than when they are used separately, extending the synergic use of the heat pumps to satisfy both heating and cooling loads. Furthermore, the benefit of TES when components of the system (chiller or boiler) are under-sized is assessed. It was observed that in these cases, TES contributes to satisfying the thermal demands. However, due to the configuration of the system, there is a limit of chiller under-sizing that TES units can compensate. Then, the influence of part-load operation of energy hub devices was studied for the same energy hub. In practice, part-load efficiency of equipment such as chillers, boilers, and heat pumps need to be taken into account in the design and control of heating and cooling networks as it can strongly affect their overall performance. However, optimization models such as energy hubs usually consider constant efficiencies due to the challenge of implementing part-load efficiency in such models. Therefore, the impact of part-load efficiency curves on energy hub optimization results is often unclear, in particular when multiple devices are included. In this work, the lifetime cost of a combined heating and cooling networks system was optimized based on an energy hub in which part-load efficiency devices (natural gas boilers, electric heaters, electric chillers, and heat pumps) were modeled. The model was linearized and studied under different combinations of thermal loads. An iterative method was developed to optimize the design and operation of the energy hub in this context. To determine the impact of part-load efficiencies, each device was individually examined while the efficiency of other devices remained constant. The error resulting from assuming a constant efficiency was then calculated based on a reference hub with constant efficiencies. The results indicated a maximum error on the total cost of 1.85%, 0.6%, and 0.16% by assuming constant-efficiency for the boilers, chillers, and heat pumps respectively. The loads for which these maximum errors occur were then chosen to optimize the hub with all devices modeled with a part-load efficiency curve. The errors increased to 1.9%, 0.71%, and 1.49%, respectively. Finally, the waste heat recovery (WHR) potential of a manufacturing workshop was assessed. First, the sources of waste heat were identified and evaluated, leading to preparation of a waste heat map for the company. Subsequently, three main WHR methods were chosen and analyzed for the plant. In the summer, the possibility of replacing the current office chillers with a 52 kW single-effect absorption chiller was investigated, which would cost 8,000 CAD more than the present chillers over 20 years. For winters, t waste heat can be used for local heating purposes instead of using the electric heating systems currently used, which would save approximately 110,000 CAD over 20 years. For the rest of the year, the internal hot water consumption for the company can be supplied by using a hybrid (WHR + electricity) water heater, which would save around 2,000 CAD over the same period.
2

Analyse numérique du changement de phase solide-liquide autour d'un tube horizontal soumis à une sollicitation thermique périodique

Chabot, Christian 24 April 2018 (has links)
Ce mémoire présente un modèle mathématique et numérique pour analyser le comportement d’une unité de stockage thermique à changement de phase solide-liquide représentée par un tube autour duquel se trouve le matériau à changement de phase. Le système est soumis à une charge oscillant entre le chauffage et le refroidissement. Une analyse d’ordre de grandeur permet de prédire le comportement du système en fonction des principaux nombres adimensionnels. Un paramètre adimensionnel est proposé pour délimiter les concepts dans lesquels la conduction domine par rapport à ceux où la convection naturelle domine. L’étude dévoile l’impact des paramètres de conception de l’unité de stockage thermique sur son fonctionnement et approfondit les connaissances dans le domaine du changement de phase avec convection naturelle. Différents indicateurs ont été développés pour analyser la performance du système, tels que les dimensions de la zone affectée thermiquement, le volume fondu ou solidifié et une analyse fréquentielle. Des corrélations sont proposées pour déterminer facilement le comportement du système. / This master thesis presents a mathematical and numerical model to analyze the behavior of a latent solid-liquid heat storage unit represented by a tube surrounded by phase change material. The system is undergoing an oscillating load of heating and cooling. A scale analysis predicts the behavior of the system with regard to the main governing dimensionless numbers. A normalized parameter is proposed to delineate designs in which conduction dominates compared to those in which natural convection dominates. The study reveals the impact of major thermal storage unit design parameters on its operation and deepens our knowledge in the field of phase change with natural convection. Various indicators, such as the size of the thermally affected zone around the tube, the molten or solidified volume and a frequency analysis, have been developed to analyze the system performance. Correlations are proposed to easily determine the system behavior.
3

Experimental and numerical study of metal foam composites in innovative application of thermal energy storage / Etude expérimentale et numérique des mousses métalliques composites dans une application d'énergie thermique

Zhu, Feng 16 March 2017 (has links)
L'objectif de cette thèse de doctorat est d'étudier expérimentalement et numériquement le comportement thermique des mousses d'aluminium et des matériaux à changement de phase (MCP), présentés sous la forme d’un composite, afin de connaître le phénomène de stockage d’énergie thermique dans ces matériaux. Le procédé de fabrication de la mousse d'aluminium à cellules ouvertes est d’abord analysé numériquement dans le but de réduire les défauts formés durant la fabrication. Les caractéristiques de transfert de chaleur du MCP dans les mousses d'aluminium comportant différentes porosités sont ensuite étudiées en analysant les processus de fusion et la variation de températures dans ces composites. Deux modèles numériques pour la mousse d'aluminium à faible et à haute porosité sont établis afin d’évaluer la performance de stockage d'énergie des composites. Les résultats montrent que la mousse d'aluminium peut améliorer considérablement la performance de transfert de chaleur du MCP en raison de sa conductivité thermique élevée. La performance de stockage d'énergie dépend fortement de la porosité des mousses d'aluminium. Une porosité optimisée met en évidence cette performance et l’amélioration du comportement thermique. La dernière partie de la thèse porte sur une structure améliorée de la mousse par rapport à la structure uniforme: Association de l’ailette métallique et du gradient de porosité de la mousse. Cette nouvelle structure donne ainsi une performance de stockage d'énergie encore meilleure surtout dans le cas d’une source de chaleur isotherme / The objective of this Ph.D. thesis is to study the thermal behavior of the aluminum foam and phase change material (PCM) composite by both experimental and numerical methods in order to know the phenomena of storage of thermal energy in these materials. The manufacturing process of open-cell aluminum foam is firstly analyzed numerically to reduce the manufacturing defects in the samples. The heat transfer characteristics of PCM embedded in aluminum foams with different porosities are then investigated by analyzing the melting processes and the temperature variations in the composites. Two numerical models for low and high porosity aluminum foam are established to evaluate the energy storage performance of the composites. The results show that the aluminum foam can greatly improve the heat transfer performance in PCM due to its high thermal conductivity. The energy storage performance depends strongly on the porosity of the aluminum foam/PCM composite. An optimized porosity highlights this performance and improves the thermal behavior. The last part of this thesis proposes an improved structure of aluminum foam with respect to the uniform structure: Association of the metal fin and the foam with graded porosity. This new structure possesses a better energy storage performance especially in the case of the isothermal heat source
4

Aluminum foams composite : elaboration and thermal properties for energy storage / Mousses d’aluminium composites : élaboration et propriétés thermiques pour le stockage d’énergie

Zhang, Chuan 07 July 2017 (has links)
L'objectif de cette thèse est d'étudier et d'optimiser le processus de fabrication des mousses métalliques et le comportement thermique du matériau de la mousse d'aluminium/matériau de changement de phase (MCP) par des méthodes expérimentales et numériques. Le processus d’élaboration de la mousse d’aluminium à pore ouvert est développé et optimisé pour contrôler précisément les paramètres de fabrication. Deux modèles de mousse d'aluminium à haute porosité (MAHP)/MCP composite et à faible porosité (MALP)/MCP composite sont établis pour la simulation numérique. En simulant le processus de fusion d'un système de stockage d'énergie, les composites MAHP/MCP et MALP/MCP sont comparés numériquement afin d'évaluer la performance de stockage d'énergie thermique. Les résultats montrent que la mousse d'aluminium améliore nettement le processus de transfert de chaleur dans MCP en raison de sa haute conductivité thermique. La porosité des mousses d'aluminium influence non seulement le processus de fusion du composite mais aussi la performance de stockage d'énergie thermique. Grâce à la collaboration avec EPF, une nouvelle méthode d’élaboration des mousses périodiques d'aluminium à pore ouvert est développée dans cette thèse sur la base d’impression 3D. Le comportement thermique des mousses d'aluminium périodiques à pore ouvert/MCP est analysé expérimentalement et numériquement / The objective of this thesis is to study and optimize the manufacturing process of metal foams and the thermal behavior of the aluminum foam/phase change material (PCM) composite by experimental and numerical methods. The manufacturing process of open-cell aluminum foam is developed and optimized to precisely control the parameters of mufacturing. Two pore-scale models of high porosity aluminum foams (HPAF)/PCM composite and low porosity aluminum foams (LPAF)/PCM composite are established for numerical simulation. By simulating the melting process of a layer energy storage system, the HPAF/PCM and LPAFS/PCM composite are compared numerically in order to evaluate the energy storage performance. The results show that aluminum foam improves greatly the heat transfer process in PCM due to its high thermal conductivity. The porosity of aluminum foams could not only influence the melting process of composite but also the energy storage performance. Thanks to the collaboration with EPF, a new manufacturing method of periodic open-cell aluminum foams is developed based on 3D rapid tooling. The thermal behavior of the periodic open-cell aluminum foams/PCM composite is experimentally and numerically analyzed
5

Application of infrared waveguides and high-temperature storage unites

Naji, Majid 12 April 2018 (has links)
Les études présentées dans cette thèse de maîtrise concernent quelques applications d'unités de stockage lithiques d'énergie thermique à haute température couplées à des guides d'ondes métalliques afin de fournir le rayonnement infrarouge aux cibles choisies. Le contexte de cette étude est le besoin de stocker l'énergie fluctuante de sources renouvelables telles que l'énergie éolienne et l'énergie solaire photovoltaïque. Les deux matériaux lithiques qui ont été choisis pour le stockage d'énergie étaient des blocs de gabbro et des briques réfractaires en olivine fabriquées par la firme Stiebel Eltron. La température de stockage varie de 500 à 900 degrés Celsius. À ces températures des puissances infrarouges de plusieurs centaines de watts peuvent être couplées dans de grands guides d'ondes métalliques creux et peuvent être guidées aux secteurs où le chauffage est désiré. Deux moyens de stocker l'énergie solaire dans le stockage lithic à hautes températures ont été étudiés : 1 - la lumière du soleil est focalisée dans les fibres optiques pénétrant les unités lithiques de stockage, et 2 - l'électricité provient des capteurs solaires photovoltaïques. Les domaines d'application qui ont été étudiés étaient : 1 - stockage thermique pour les maisons, 2 - sous-ensembles infrarouges de distribution pour garder la nourriture chaude et pour le chauffage d'espace, et 3 - un système de chauffage pour une station lunaire.

Page generated in 0.0786 seconds