• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Crack lengths calculation by unloading compliance technique for Charpy size specimens

Dzugan, Jan 31 March 2010 (has links) (PDF)
The problems with the crack length determination by the unloading compliance method are well known for Charpy size specimens. The final crack lengths calculated for bent specimens do not fulfil ASTM 1820 accuracy requirements. Therefore some investigations have been performed to resolve this problem. In those studies it was considered that measured compliance should be corrected for various factors, but satisfying results were not attained. In the presented work the problem was attacked from the other side, the measured specimen compliance was taken as a correct value and what had to be adjusted was the calculation procedure. On the basis of experimentally obtained compliances of bent specimens and optically measured crack lengths the investigation was carried out. Finally, a calculation procedure enabling accurate crack length calculation up to 5mm of plastic deflection was developed. Applying the new procedure, out of investigated 238 measured crack lengths, more than 80% of the values fulfilled the ASTM 1820 accuracy requirements, while presently used procedure provided only about 30% of valid results. The newly proposed procedure can be also prospectively used in modified form for the specimens of different than Charpy size.
2

Crack lengths calculation by unloading compliance technique for Charpy size specimens

Dzugan, Jan January 2003 (has links)
The problems with the crack length determination by the unloading compliance method are well known for Charpy size specimens. The final crack lengths calculated for bent specimens do not fulfil ASTM 1820 accuracy requirements. Therefore some investigations have been performed to resolve this problem. In those studies it was considered that measured compliance should be corrected for various factors, but satisfying results were not attained. In the presented work the problem was attacked from the other side, the measured specimen compliance was taken as a correct value and what had to be adjusted was the calculation procedure. On the basis of experimentally obtained compliances of bent specimens and optically measured crack lengths the investigation was carried out. Finally, a calculation procedure enabling accurate crack length calculation up to 5mm of plastic deflection was developed. Applying the new procedure, out of investigated 238 measured crack lengths, more than 80% of the values fulfilled the ASTM 1820 accuracy requirements, while presently used procedure provided only about 30% of valid results. The newly proposed procedure can be also prospectively used in modified form for the specimens of different than Charpy size.

Page generated in 0.0573 seconds