• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Die Luftheizungen des Mittelalters : zur Typologie und Entwicklung eines technikgeschichtlichen Phänomens /

Bingenheimer, Klaus. January 1900 (has links)
Dissertation--Darmstadt--Technische Universität, 1998. / Bibliogr. p. 405-424.
2

Analyse du comportement thermique d'une serre munie d'un système de stockage de chaleur souterrain

Joly, Patrick. January 2000 (has links)
Thèses (M.Sc.A.)--Université de Sherbrooke (Canada), 2000. / Titre de l'écran-titre (visionné le 17 juillet 2006). Publié aussi en version papier.
3

Optimization of design and operation of synergetic heating and cooling networks based on the energy hub concept

Ahmadisedigh, Hossein 20 June 2022 (has links)
Dans le présent travail, un modèle de « hub énergétique » a été utilisé pour concevoir des réseaux combinés de chauffage et de refroidissement afin de bénéficier des synergies potentielles. Les réseaux de chauffage et de refroidissement font partie intégrante de divers bâtiments, campus ou villes. Le concept de réseau thermique intelligent et de « hub énergétique » plaide en faveur de l'intégration thermique pour bénéficier des synergies potentielles et faciliter l'utilisation des sources d'énergie renouvelables. Dans ce système intégré, les pompes à chaleur peuvent être utilisées pour récupérer la chaleur de la boucle de refroidissement et la fournir à la boucle de chauffage. La récupération de la chaleur résiduelle peut aider à réduire les coûts d'exploitation et les émissions de gaz à effet de serre. Les charges de chauffage et de refroidissement du réseau peuvent être satisfaites par des chaudières au gaz naturel, des radiateurs électriques, des refroidisseurs et des pompes à chaleur. La conception du système et son fonctionnement ont été optimisés en termes de coût et d'émissions de gaz à effet de serre sous différentes combinaisons de charges de chauffage et de refroidissement. Les configurations de hub optimisées pour les scénarios avec et sans récupération de chaleur perdue ont été comparées, montrant que les pompes à chaleur étaient bénéfiques dans tous les scénarios. La capacité optimale des pompes à chaleur pour minimiser le coût total s'est avérée être d'environ 80% de la valeur maximale possible à partir d'une analyse thermodynamique des charges. La minimisation simultanée des coûts et des émissions a révélé une transition relativement nette du chauffage au gaz au chauffage électrique, car l'accent est davantage mis sur les émissions que sur les coûts, mais dans tous les cas, la récupération de la chaleur perdue avec des pompes à chaleur a été largement utilisée pour satisfaire les charges de chauffage et de refroidissement. Ensuite, en gardant le même cadre conçu ci-dessus, une méthode a été développée pour indiquer comment les unités de stockage d'énergie thermique (SET) peuvent contribuer à réduire le coût total d'un réseau thermique. Nous avons développé une méthode montrant comment les unités SET, couplées à des pompes à chaleur, peuvent contribuer à réduire le coût total d'un réseau thermique. Un modèle d'optimisation est introduit, basé sur un modèle de hub énergétique comprenant des chaudières au gaz naturel, des radiateurs électriques et des refroidisseurs. Pour différents profils de charge, les réseaux thermiques intégrant des pompes à chaleur seules, SET seules ou une combinaison des deux sont comparés à un hub de référence sans intégration thermique. Il a été constaté que l'inclusion à la fois du SET et des pompes à chaleur génère plus de bénéfices que lorsqu'elles sont utilisées séparément, étendant l'utilisation synergique des pompes à chaleur pour satisfaire à la fois les charges de chauffage et de refroidissement. De plus, l'intérêt du SET lorsque les composants du système(refroidisseur ou chaudière) sont sous-dimensionnés est évalué. Il a été observé que dans ces cas, le SET contribue à satisfaire les demandes thermiques. Cependant, en raison de la configuration du système, il existe une limite de sous-dimensionnement du refroidisseur que les unités SET peuvent compenser. Ensuite, l'influence du fonctionnement à charge partielle des dispositifs du hub énergétique a été étudiée pour le même hub énergétique. Dans la pratique, l'efficacité à charge partielle des équipements tels que les refroidisseurs, les chaudières et les pompes à chaleur doit être prise en compte dans la conception et le contrôle des réseaux de chauffage et de refroidissement car elle peut fortement affecter leurs performances globales. Cependant, les modèles d'optimisation tels que les hubs énergétiques considèrent généralement des efficacités constantes en raison du défi de mettre en œuvre l'efficacité à charge partielle dans de tels modèles. Par conséquent, l'impact des courbes d'efficacité à charge partielle sur les résultats d'optimisation des hubs énergétiques n'est souvent pas clair, en particulier lorsque plusieurs appareils sont inclus. Dans ce travail, le coût total sur la vie d'un système de réseaux combinés de chauffage et de refroidissement a été optimisé sur la base d'un hub énergétique dans lequel des dispositifs d'efficacité à charge partielle (chaudières à gaz naturel, radiateurs électriques, refroidisseurs électriques et pompes à chaleur) ont été modélisés. Le modèle a été linéarisé et étudié sous différentes combinaisons de charges thermiques. Une méthode itérative a été développée pour optimiser la conception et l'exploitation du pôle énergétique dans ce contexte. Pour déterminer l'impact des efficacités à charge partielle, chaque appareil a été examiné individuellement tandis que l'efficacité des autres appareils est restée constante. L'erreur résultant de l'hypothèse d'un rendement constant a ensuite été calculée sur la base d'un hub de référence avec des rendements constants. Les résultats ont indiqué une erreur maximale sur le coût total de 1,85 %, 0,6 % et 0,16 % en supposant un rendement constant pour les chaudières, les refroidisseurs et les pompes à chaleur respectivement. Les charges pour lesquelles ces erreurs maximales se produisent ont ensuite été choisies pour optimiser le hub avec tous les appareils modélisés avec une courbe d'efficacité à charge partielle. Les erreurs ont augmenté à 1,9 %, 0,71 % et 1.49 %, respectivement. Enfin, le potentiel de récupération de chaleur perdue (WHR) d'un atelier de fabrication a été évalué. Dans un premier temps, les sources de chaleur résiduelle ont été identifiées et évaluées, ce qui a conduit à la préparation d'une carte de chaleur résiduelle pour l'entreprise. Par la suite, trois principales méthodes de récupération de la chaleur ont été choisies et analysées pour l'usine. Pour les étés, la possibilité de remplacer les refroidisseurs actuels de bureaux par un refroidisseur à absorption simple effet de 52 kW a été étudiée, ce qui coûterait 8,000 CAD de plus que les refroidisseurs actuels sur 20 ans. Pour les hivers, le flux de chaleur résiduelle conditionné peut être utilisé à des fins de chauffage local au lieu d'utiliser les systèmes de chauffage électrique actuellement utilisés, ce qui permettrait d'économiser environ 110,000 CAD sur 20 ans. Pour le reste de l'année, la consommation interne d'eau chaude de l'entreprise peut être fournie en utilisant un chauffe-eau hybride (WHR+ électricité), ce qui permettrait d'économiser environ 2,000 CAD sur la même période. / In the present work, an "energy hub" template was employed to design combined heating and cooling networks to benefit from potential synergies. Heating and cooling networks are integral components of various buildings, campuses, or cities. The concept of smart thermal grid and "energy hub" argue in favor of thermal integration to benefit from potential synergies and facilitate the use of renewable energy sources. In this integrated system, heat pumps can be used to recover heat from the cooling loop and supply it to the heating loop. Waste heat recovery can help reducing operation costs and greenhouse gas emissions. Heating and cooling loads of the network can be satisfied by natural gas boilers, electric heaters, chillers, and heat pumps. The design of the system and its operation were optimized with respect to cost and greenhouse gas emissions under different combinations of heating and cooling loads. The optimized hub configurations for scenarios with and without waste heat recovery were compared, showing that heat pumps were beneficial in all scenarios. The optimal capacity of heat pumps to minimize total cost was found to be ~80% of the maximal possible value from a thermodynamic analysis of the loads. The simultaneous minimization of cost and emissions revealed a relatively sharp transition from gas to electric heating as more emphasis is put on emissions than cost, but in all cases, waste heat recovery with heat pumps was heavily used to satisfy the heating and cooling loads. Next, keeping the same framework designed above, a method was developed to indicate how thermal energy storage (TES) units can contribute to reduce the total cost of a thermal grid. We developed a method showing how TES units, coupled with heat pumps, can contribute to reducing the total cost of a thermal grid. An optimization model is introduced, based on an energy hub model including natural gas boilers, electric heaters, and chillers. For different load profiles, thermal grids integrating heat pumps alone, TES alone, or a combination of both are compared to a reference hub with no thermal integration. It was found that the inclusion of both TES and heat pumps together results in more profits than when they are used separately, extending the synergic use of the heat pumps to satisfy both heating and cooling loads. Furthermore, the benefit of TES when components of the system (chiller or boiler) are under-sized is assessed. It was observed that in these cases, TES contributes to satisfying the thermal demands. However, due to the configuration of the system, there is a limit of chiller under-sizing that TES units can compensate. Then, the influence of part-load operation of energy hub devices was studied for the same energy hub. In practice, part-load efficiency of equipment such as chillers, boilers, and heat pumps need to be taken into account in the design and control of heating and cooling networks as it can strongly affect their overall performance. However, optimization models such as energy hubs usually consider constant efficiencies due to the challenge of implementing part-load efficiency in such models. Therefore, the impact of part-load efficiency curves on energy hub optimization results is often unclear, in particular when multiple devices are included. In this work, the lifetime cost of a combined heating and cooling networks system was optimized based on an energy hub in which part-load efficiency devices (natural gas boilers, electric heaters, electric chillers, and heat pumps) were modeled. The model was linearized and studied under different combinations of thermal loads. An iterative method was developed to optimize the design and operation of the energy hub in this context. To determine the impact of part-load efficiencies, each device was individually examined while the efficiency of other devices remained constant. The error resulting from assuming a constant efficiency was then calculated based on a reference hub with constant efficiencies. The results indicated a maximum error on the total cost of 1.85%, 0.6%, and 0.16% by assuming constant-efficiency for the boilers, chillers, and heat pumps respectively. The loads for which these maximum errors occur were then chosen to optimize the hub with all devices modeled with a part-load efficiency curve. The errors increased to 1.9%, 0.71%, and 1.49%, respectively. Finally, the waste heat recovery (WHR) potential of a manufacturing workshop was assessed. First, the sources of waste heat were identified and evaluated, leading to preparation of a waste heat map for the company. Subsequently, three main WHR methods were chosen and analyzed for the plant. In the summer, the possibility of replacing the current office chillers with a 52 kW single-effect absorption chiller was investigated, which would cost 8,000 CAD more than the present chillers over 20 years. For winters, t waste heat can be used for local heating purposes instead of using the electric heating systems currently used, which would save approximately 110,000 CAD over 20 years. For the rest of the year, the internal hot water consumption for the company can be supplied by using a hybrid (WHR + electricity) water heater, which would save around 2,000 CAD over the same period.
4

Etude d'un système combiné de ventilation et de chauffage au bois dans les bâtiments à basse consommation d'énergie

Peigné, Pierre 27 February 2012 (has links) (PDF)
Ce travail porte sur l'étude et le développement d'un système innovant de ventilation et de chauffage au bois dans les habitations à basse consommation d'énergie, qui sont appelées à devenir la référence constructive en France dès 2015. Dans ces habitations fortement isolées et particulièrement étanches à l'air, les besoins de chauffage sont très faibles et peuvent être couverts par une source de chaleur d'origine renouvelable, telle que le bois énergie. En outre, l'utilisation d'une ventilation performante s'impose comme étant un critère essentiel pour assurer la bonne qualité de l'air intérieur et peut même devenir l'unique vecteur de chauffage en apportant l'appoint de chaleur sur l'air insufflé dans les différentes pièces de l'habitation. Le système présenté dans cette étude propose ainsi de combiner les avantages d'un appareil de chauffage au bois de petite puissance, ici un poêle à granulés de bois, et ceux d'une ventilation à récupération de chaleur sur l'air extrait, grâce à un conduit échangeur intégré à la cheminée du poêle et relié au réseau de soufflage de la ventilation. Développé en partenariat avec l'industriel POUJOULAT, spécialisé dans la fabrication de conduits de cheminée métalliques, ce conduit échangeur permet de récupérer sur l'air neuf une partie de la chaleur initialement perdue par les fumées et de la distribuer dans toutes des zones de vie de l'habitation, même les plus éloignées de l'appareil au bois. Après avoir défini la configuration de couplage à adopter pour assurer le bon fonctionnement de l'ensemble et garantir à la fois la sécurité et le confort des occupants, les performances de plusieurs prototypes de conduit échangeur sont caractérisées expérimentalement. Les résultats obtenus lors des essais en laboratoire permettent alors d'orienter l'évolution des prochains prototypes et de souligner la nécessité de travailler avec un poêle à granulés de bois dont le cycle de combustion est étanche. Un modèle mathématique est également développé pour prédire les performances du dernier prototype de conduit échangeur à triple paroi non isolé sur sa surface extérieure et sa validation est obtenue suite au bon accord entre les résultats calculés et ceux mesurés lors des essais. L'ensemble du système combiné est ensuite installé dans deux habitations à basse consommation d'énergie situées près de Poitiers. L'exploitation des températures et des consommations recueillies pendant la première saison de chauffe montre la bonne tenue du système combiné, ses limites, ainsi que ses conditions d'appropriation par les occupants, dont le comportement apparaît jouer un rôle prédominant dans la réduction des consommations énergétiques.
5

Etude d'un système combiné de ventilation et de chauffage au bois dans les bâtiments à basse consommation d'énergie / Study of a wook-based heating system combined with a heat recovery ventilation in low energy buildings

Peigné, Pierre 27 February 2012 (has links)
Ce travail porte sur l’étude et le développement d’un système innovant de ventilation et de chauffage au bois dans les habitations à basse consommation d’énergie, qui sont appelées à devenir la référence constructive en France dès 2015. Dans ces habitations fortement isolées et particulièrement étanches à l’air, les besoins de chauffage sont très faibles et peuvent être couverts par une source de chaleur d’origine renouvelable, telle que le bois énergie. En outre, l’utilisation d’une ventilation performante s’impose comme étant un critère essentiel pour assurer la bonne qualité de l’air intérieur et peut même devenir l’unique vecteur de chauffage en apportant l’appoint de chaleur sur l’air insufflé dans les différentes pièces de l’habitation. Le système présenté dans cette étude propose ainsi de combiner les avantages d’un appareil de chauffage au bois de petite puissance, ici un poêle à granulés de bois, et ceux d’une ventilation à récupération de chaleur sur l’air extrait, grâce à un conduit échangeur intégré à la cheminée du poêle et relié au réseau de soufflage de la ventilation. Développé en partenariat avec l’industriel POUJOULAT, spécialisé dans la fabrication de conduits de cheminée métalliques, ce conduit échangeur permet de récupérer sur l’air neuf une partie de la chaleur initialement perdue par les fumées et de la distribuer dans toutes des zones de vie de l’habitation, même les plus éloignées de l’appareil au bois. Après avoir défini la configuration de couplage à adopter pour assurer le bon fonctionnement de l’ensemble et garantir à la fois la sécurité et le confort des occupants, les performances de plusieurs prototypes de conduit échangeur sont caractérisées expérimentalement. Les résultats obtenus lors des essais en laboratoire permettent alors d’orienter l’évolution des prochains prototypes et de souligner la nécessité de travailler avec un poêle à granulés de bois dont le cycle de combustion est étanche. Un modèle mathématique est également développé pour prédire les performances du dernier prototype de conduit échangeur à triple paroi non isolé sur sa surface extérieure et sa validation est obtenue suite au bon accord entre les résultats calculés et ceux mesurés lors des essais. L’ensemble du système combiné est ensuite installé dans deux habitations à basse consommation d’énergie situées près de Poitiers. L’exploitation des températures et des consommations recueillies pendant la première saison de chauffe montre la bonne tenue du système combiné, ses limites, ainsi que ses conditions d’appropriation par les occupants, dont le comportement apparaît jouer un rôle prédominant dans la réduction des consommations énergétiques. / This work is devoted to the study and development of an innovative wood-based air-heating system for energy-efficient dwellings, which are expected to become the building reference in France from 2015 onwards. As these kinds of homes are highly insulated and particularly airtight, heating requirements are very low and may be covered by a renewable energy source, such as wood energy. In addition, efficient ventilation is absolutely required to ensure indoor air quality and may even sometimes be use as the only way to provide heat into the various rooms of the house. In this context, the system presented in this study aims to combine advantages of a low power wood-burning appliance, as a wood-pellet stove, and those of a mechanical ventilation heat-recovery unit, thanks to a heat exchanger integrated into the chimney of the pellet stove and connected to the ventilation air supply network. Developed in partnership with POUJOULAT, a metallic chimneys manufacturer, this new heat exchanger recovers a part of the heat from flue gases and enables to warm up the fresh air distributed in each living zone of the house, even the most remote of the wood heating device. After defining the best coupling configuration to ensure the proper behaviour of the system, as well as both safety and comfort of the occupants, performances of several heat exchanger prototypes are characterized experimentally. The results from tests in laboratory are then used to guide prototypes development and they highlight the need to work with a room-sealed wood-pellet stove. Moreover, a mathematical model is developed to predict the performances of the latest prototype of triple concentric tube heat exchanger with no insulation at the outer surface. Then, the model validation is obtained following the good agreement between calculated results and those measured during the laboratory tests. The combined system is then installed in two energy-efficient dwellings near Poitiers. Operating temperatures and energy consumptions collected during the first heating season show the good reliability of the combined system, its limitations and its conditions of acceptance by the occupants, whose behaviour is pointed out as a major factor in reducing energy consumptions.

Page generated in 0.0151 seconds