• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement de nouvelles sondes per-opératoires positon pour guider la chirurgie des tumeurs solides / Development of new intraoperative positron probes to guide solid tumors surgery

Hudin, Nicolas 03 October 2013 (has links)
L’exérèse des tumeurs cancéreuses est une procédure courante pour le traitement de nombreux cancers. L’enjeu est de réaliser une excision la plus complète possible pour éviter les récidives tout en épargnant le plus possible les tissus sains bordant la tumeur. La détection de positons est une modalité d’imagerie particulièrement adaptée au repérage de résidus tumoraux lors de l'éxerèse car sa forte sélectivité spatiale permet de s'affranchir du bruit provenant de la fixation non spécifique du radiotraceur dans les tissus situés en profondeur, offrant ainsi une meilleur sensibilité et un meilleur rapport signal sur bruit que la détection de photons gamma. L’utilisation pour le contrôle d’exérèse impose cependant une contrainte forte sur les dimensions du détecteur qui doit être manipulable facilement par le chirurgien et pouvoir être inséré dans des plaies opératoires potentiellement étroites. Une nouvelle génération de photodétecteurs appelés photomultiplicateurs silicium (SiPM) est particulièrement adaptée à cette application car ceux-ci allient la compacité et la robustesse des technologies silicium avec d'excellentes performances de détection. Mon travail de thèse porte sur le développement et la caractérisation de nouvelles sondes positon basées sur ces photodétecteurs. Dans un premier temps, un travail de caractérisation des SiPMs a été réalisé pour évaluer leurs performances pour la détection de positons. Deux prototypes de prototypes de détecteurs aux rôles complémentaires ont ensuite été réalisé: le premier est un imageur, basé sur l’assemblage de deux scintillateurs avec une ou deux matrices de SiPMs, qui permet de réaliser rapidement l'image de la distribution de traceur sur une large surface de tissus. Le second détecteur est une sonde de comptage, constituée de fibres scintillantes couplées à des SiPMs individuels via des fibres claires et capable d'être couplée à l'outil d'exérèse. Elle permet de guider l'outil du chirurgien vers les tissus repérés préalablement avec l'imageur. La caractérisation de l’imageur a montré sa capacité à détecter des résidus tumoraux de petite taille (15mg) avec une résolution submillimétrique. La sonde de comptage présente quant à elle, une efficacité de détection de 80%. / Excision of cancerous tumors is a common procedure for the treatment of numerous cancers. The stake is to perform the most complete excision to prevent recurrences while preserving as much as possible surrounding healthy tissues. Positron detection is a well suited imaging modality for detection of tumor remains during excision because its strong spatial selectivity makes it insensitive to the noise coming from the non-specific accumulation of the radiotracer in healthy tissues located far from the detector, leading to a better sensitivity and a better signal-to-noise ratio than gamma photon detection. Its use for the control of excision implies however strong constraints on detector dimensions which must be easy to handle by the surgeon and easy to insert in tight surgical wound. A new generation of photodetectors called Silicon Photmultipliers (SiPMs) is particularly suited for this application because they present the compactness and robustness of silicon technologies and very good detection performances. My thesis aims to develop and characterize a new generation of new positron probes based on these photodetectors. Two prototypes of detectors with complementary roles were realized: the first one is an imaging device based on the assembly of two scintillators with one or two SiPMs arrays which allows to quickly make an image of tracer distribution along a wide surface of tissues. The second detector is a counting probe made of scintillating fibers associated with individual SiPMs through clear optical fibers and can be associated to the excision tool. It guides the surgeon tool to the tissues previously localized with the imaging probe. Characterization of the imaging probe showed its ability to detect small tumor remains (15mg) with a submillimetric resolution. The counting probe showed a detection efficiency of 80%.
2

Développement de nouvelles sondes per-opératoires positon pour guider la chirurgie des tumeurs solides

Hudin, Nicolas 03 October 2013 (has links) (PDF)
L'exérèse des tumeurs cancéreuses est une procédure courante pour le traitement de nombreux cancers. L'enjeu est de réaliser une excision la plus complète possible pour éviter les récidives tout en épargnant le plus possible les tissus sains bordant la tumeur. La détection de positons est une modalité d'imagerie particulièrement adaptée au repérage de résidus tumoraux lors de l'éxerèse car sa forte sélectivité spatiale permet de s'affranchir du bruit provenant de la fixation non spécifique du radiotraceur dans les tissus situés en profondeur, offrant ainsi une meilleur sensibilité et un meilleur rapport signal sur bruit que la détection de photons gamma. L'utilisation pour le contrôle d'exérèse impose cependant une contrainte forte sur les dimensions du détecteur qui doit être manipulable facilement par le chirurgien et pouvoir être inséré dans des plaies opératoires potentiellement étroites. Une nouvelle génération de photodétecteurs appelés photomultiplicateurs silicium (SiPM) est particulièrement adaptée à cette application car ceux-ci allient la compacité et la robustesse des technologies silicium avec d'excellentes performances de détection. Mon travail de thèse porte sur le développement et la caractérisation de nouvelles sondes positon basées sur ces photodétecteurs. Dans un premier temps, un travail de caractérisation des SiPMs a été réalisé pour évaluer leurs performances pour la détection de positons. Deux prototypes de prototypes de détecteurs aux rôles complémentaires ont ensuite été réalisé: le premier est un imageur, basé sur l'assemblage de deux scintillateurs avec une ou deux matrices de SiPMs, qui permet de réaliser rapidement l'image de la distribution de traceur sur une large surface de tissus. Le second détecteur est une sonde de comptage, constituée de fibres scintillantes couplées à des SiPMs individuels via des fibres claires et capable d'être couplée à l'outil d'exérèse. Elle permet de guider l'outil du chirurgien vers les tissus repérés préalablement avec l'imageur. La caractérisation de l'imageur a montré sa capacité à détecter des résidus tumoraux de petite taille (15mg) avec une résolution submillimétrique. La sonde de comptage présente quant à elle, une efficacité de détection de 80%.

Page generated in 0.0557 seconds