• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da influencia dos recobrimentos de molde no controle da solidificação unidirecional do chumbo comercialmente puro

Campos, Carlos Alfredo Baptista de 14 July 2018 (has links)
Orientador : Mauricio Prates de Campos Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T11:30:50Z (GMT). No. of bitstreams: 1 Campos_CarlosAlfredoBaptistade_M.pdf: 2328808 bytes, checksum: 6a78448a68a0b467a5572548addad8de (MD5) Previous issue date: 1975 / Resumo: Tendo em vista a influência que os recobrimentos de molde exercem sôbre o regime de transferência de calor do sistema metal-molde, estudou-se de forma sistemática os efeitos de diversos recobrimentos (Alumina, Negro de Fumo Dycote 39 e Dycote 34), sôbre a eficiência do contato térmico entre o metal e o molde, traduzi da parametricamente pelo coeficiente de transmissão de calor da interface metal-molde. Para tanto adotou-se o chumbo comercialmente puro como metal tipo o qual foi solidificado sob diversas condições em um dispositivo unidirecional especialmente projetado e construído. Os resultados obtidos mostram a possibilidade de controle do processo de solidificação por meio da aplicação adequada dos diferentes tipos de recobrimentos de molde, em particular no que se refere a cinética de solidificação, a macro estrutura resultante (Tamanho de Grão) e a variação da temperatura da interface metal-molde. Finalmente testa-se um modelo unidirecional parabólico para a descrição analítica da solidificação do chumbo comercial / Abstract: Considering the influence that the coatings applied on the metal-mold interface have on the heat extractions conditions of the system, it was analysed the influence of different coatings covering the internal surface of the refrigerated mold (Alumina, Lamp-black, Dycote 39 e Dycote 34), over the efficiency of the thermal contact between metal and mold, represented parametrically by the heat transfer coefficient of the metal-mold interface. It was used commercial - lead as the standard material solidified under several conditions, in an unidirectional apparatus, designed and built for this purpose. The results showed the possibility of control ling the solidification process by applying the correct coating at the metal-mold interface, particularly the kinetics of the process, the resulting structure and the temperatura of the metal-mold interface. Finally, the parabolic unidirectional model was verified for the case of solidification of commercial lead / Mestrado / Mestre em Engenharia Mecânica
2

Pesquisa de novos materiais para uso nos sistemas de ventilacao/exaustao das empresas de pequeno porte do tipo fabrica de bateria chumbo-acidas

Fortes, Julio Domingos Nunes. January 2003 (has links) (PDF)
Doutor -- Escola Nacional de Saude Publica, Rio de Janeiro, 2003.
3

Avaliação ambiental do processo de reciclagem de chumbo

Machado, Iraci Pereira 27 February 2002 (has links)
Orientador : Waldir Antonio Bizzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-01T17:30:03Z (GMT). No. of bitstreams: 1 Machado_IraciPereira_M.pdf: 4557152 bytes, checksum: ed63a0ea53e0162654d1ce176e398b0e (MD5) Previous issue date: 2002 / Resumo: O chumbo é o quinto metal mais utilizado na indústria. É empregado principalmente na fabricação de baterias ácidas. Sua reciclagem é feita devido à escassez do mesmo nas jazidas existentes, além da preocupação com o meio ambiente. Os resíduos contendo chumbo são classificados segundo a norma brasileira de resíduos (NBR-IOO4) como perigosos. O processo de reciclagem é constituído por duas fases: separação dos componentes da bateria ácida de chumbo e fusão do metal em fornos de redução. Este trabalho realizou uma avaliação ambiental do processo de reciclagem de chumbo utilizado em três unidades de reciclagem no Brasil. Para atingi-Io, foram desmontadas baterias e seus componentes analisados com o intuito de caracterizar o material a ser reciclado. Também foram feitas visitas a recicladoras para coleta de dados, que proporcionou o levantamento de alguns índices ambientais e de consumo de insumos. Os principais fatores potenciais de contaminação ambiental identificados foram a emissão de material particulado contendo chumbo e a formação de escória também contaminada pelo mesmo metal. O resultado da caracterização das baterias e a análise dos dados obtidos nas visitas mostram que a reciclagem de chumbo é uma fonte potencial de poluição ambiental. O controle do processo de reciclagem deve ser rigoroso para se atingir padrões ambientais aceitáveis e a necessidade de muitos equipamentos de controle ambiental contribui de forma significativa para um elevado custo do processo / Abstract: Lead is the fifth metal more used in industry. lt is employed mainly in the acid batteries production. Its recycling is made due to its shortage in the existent beds, besides environment concem. The residues containing lead are classified according to the Brazilian pattem of residues (NBR-lOO4) as dangerous. The recycling process is made up by two steps: lead-acid battery components separation and metal smelting in reduction kiln. This work penormed an environmental evaluation of the brazilian lead recycling process in three recycling units at Brazil. To reach it, batteries were dismounted and its components analyzed in order to feature the material to be recycled. Besides, visits were paid to the recycling industries for data collection that provided some environmental indexes data and the inputs consumption. The main environmental potency factors contamination identified were the particle emission containing lead and the contaminated slag formation by the same metal. The batteries characterization results and the visits obtained data analysis show that the lead recycling is a potential source of environmental pollution. The recycling process control must be rigorous to reach acceptable environmental limits and the need of many control environmental equipments contributes in a significant way to rise the recycling process cost / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
4

Avaliação de alguns aspectos do passivo ambiental de uma metalurgia de chumbo em Santo Amaro da Purificação, Bahia

Costa, Ângela Cristina Andrade 07 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-16T13:29:53Z No. of bitstreams: 1 Dissert_Costa A C A.pdf: 2142681 bytes, checksum: 970020a31bcccbdb5cc428a537a55417 (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-16T13:39:53Z (GMT) No. of bitstreams: 1 Dissert_Costa A C A.pdf: 2142681 bytes, checksum: 970020a31bcccbdb5cc428a537a55417 (MD5) / Made available in DSpace on 2016-09-16T13:39:53Z (GMT). No. of bitstreams: 1 Dissert_Costa A C A.pdf: 2142681 bytes, checksum: 970020a31bcccbdb5cc428a537a55417 (MD5) / Este estudo teve como objetivos: (a) a avaliação de alguns efeitos da contaminação resultante do passivo ambiental de uma fundição desativada de chumbo (Pb) na cidade de Santo Amaro da Purificação na Bahia, verficando-se a possível correlação de exposição/absorção de chumbo e cádmio (Cd) a estudos citogenéticos utilizando populações de bois e de mulheres da vizinhança da fundição e, (b) fazer uma avaliação de risco sobre a população infantil através da dosagem das concentrações do chumbo e do cádmio no sangue de crianças. Todas as análises de Pb e Cd nas diferentes matrizes (sangue bovino e humano, urina humana, solo e gramínea) foram realizadas por espectrometria de absorção atômica com forno de grafite. Os valores médios de Pb encontrados nos animais do grupo Exposto encontram-se entre os mais elevados dentre os dados obtidos. Os testes citogenéticos efetuados nestes animais mostraram alterações cromossômicas em 18,9 % das células analisadas contra apenas 2,3 % das células do grupo Controle. Foram também determinados níveis de Pb e Cd em gramínea e solo (perfil), coletados segundo a direção predominante dos ventos, até 14 Km da antiga fundição. Foi constatado que, à medida que diminui a distância da fundição, aumentam os níveis de Pb nestas matrizes. Os níveis de Cd na urina das mulheres do grupo Exposto apresentaram-se mais elevados que no grupo Controle, não sendo observado o mesmo em relação ao Pb e Cd no sangue, sendo que 6,5 % das mulheres deste grupo apresentam alterações cromossômicas contra 1,5 % no grupo Controle, que se encontra dentro da faixa de frequência de alterações cromossômicas esperada para populações humanas normais, que varia de 1 a 4 %. Os valores médios de Pb (média aritmética: 17,1 ± 7,2 µg/dL e média geométrica: 15,4 ± 1,64 µg/dL) e Cd (média aritmética: 1,50 ± 1,54 µg/dL e média geométrica: 1,00 ± 2,57 µg/dL) no sangue das crianças do grupo Exposto encontram-se entre os mais elevados em relação a outros locais no mundo. Mais de 87 % das crianças deste grupo apresentaram níveis de Pb superiores ao limite recomendado pelo CDC (10 µg/dL). Os valores médios de Pb (média aritmética: 9,70 ± 5,70 e média geométrica: 8,52 ± 1,62 µg/dL) e Cd (média aritmética: 0,258 ± 0,246 µg/dL e média geométrica: 0,221 ± 1,58 µg/dL) encontrados nas amostras do grupo Controle são os primeiros dados locais de crianças não expostas ao Pb. / The aim of this study was: (a) to evaluate some contaminates effects from the environmental passive of a deactivated lead smelter at the city of Santo Amaro da Purificação in Bahia, verifying the possible exposition/absorption correlation of lead and cadmium in respect to mutagenic studies using cattle and women populations from the neighborhood of this smelter and (b) to evaluate the risks on infantile population as well by the dosage of the lead and cadmium concentrations on children’s blood. All the lead and cadmium analysis from the different matrices (cattle and human blood, human urine, soil and grass) were carried out using graphite furnace absorption atomic spectroscopy. The averaged Pb values found in animals of the Exposed group were among the highest in the obtained data where the mutagenic tests applied showed chromosomic alterations in 18.9 % of the analyzed cells. On the other hand, the Control group showed only 2.3 % of these chromosomic alterations. Pb and Cd levels were also determined in grass and soil (profile) and were collected following the predominant wind direction until 14 km from the smelter. It was observed the direct dependence between the decreasing of the distance from the smelter and the increasing of the Pb levels in these matrices. The Cd urine women levels of the Exposed group showed higher than the Control group. Such observation was not found in relation to Pb and Cd blood, where 6,5 % of women of this first group showed chromosomic alterations; the Control group only 1,5 %, which is in the expected frequency of chromosomic alterations for normal human populations, varying from 1 to 4 %. The average values of Pb (arithmetic media: 17.1 ± 7.2 µg/dL and geometric media: 15.4 ± 1.64 µg/dL) and Cd (arithmetic media: 1.50 ± 1.54 µg/dL and geometric media: 1.00 ± 2.57 µg/dL) of children’s blood of the Exposed group are situated among the highest values in relation to other places in the world. More than 87 % children of this group showed Pb levels higher that the maximum limit recommended by CDC (10 µg/dL). The average Pb values (arithmetic media: 9.70 ± 5.70 µg/dL and geometric media: 8.52 ± 1.62 µg/dL) and Cd (arithmetic media: 0.258 ± 0.246 µg/dL and geometric media: 0.221 ± 1.58 µg/dL) found in Control group samples were the first local Pb non-exposed children data.

Page generated in 0.0491 seconds