• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos fatores do planejamento financeiro de curto prazo: o caso de uma empresa do setor de construção civil

DOURADO, Michelle Hofmann 19 December 2014 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-03-31T14:02:20Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_2014_12_19_Michelle Hofmann Dourado.pdf: 6045933 bytes, checksum: b87585642739965e8958d3741471cc9a (MD5) / Made available in DSpace on 2016-03-31T14:02:20Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_2014_12_19_Michelle Hofmann Dourado.pdf: 6045933 bytes, checksum: b87585642739965e8958d3741471cc9a (MD5) Previous issue date: 2014-12-19 / O objetivo deste estudo foi identificar e analisar os possíveis fatores que podem promover alterações nos fluxos de caixa planejados de empreendimentos habitacionais de uma construtora de grande porte em Recife. Trata-se de um estudo de caso qualitativo onde foram comparados e analisados os fluxos de caixa previstos e realizados de três empreendimentos habitacionais, concluídos no ano de 2013, escolhidos propositalmente para análise da metodologia utilizada em suas projeções. Os dados foram coletados através de entrevistas e pesquisa documental e por meio deles foi possível concluir que o método de projeção utilizado gerou grandes distorções entre os fluxos de caixa planejados e realizados destes empreendimentos. Dentre estas distorções foi possível destacar os desvios causados pela utilização da curva de evolução física de obra para projeção dos desembolsos referentes ao custo de obra, os desvios relacionados a falha na projeção dos repasses de clientes e o efeito da complexidade, singularidade e prazo dos projetos nestas projeções. / The objective of this study was to identify and analyze the possible factors that may cause changes in planned cash flows of housing developments from a large construction company in Recife. This is a qualitative case study that compared and analyzed estimated and realized cash flows of tree housing projects completed in 2013. These projects where purposely selected to have their projections methodology analyzed. The Data for this study was obtained via personal interviews and Documentary research. Through the data analysis it was possible to conclude that the utilized projection method generated major distortions between planned and realized cash flows for these businesses. Among these distortions it was possible to highlight the deviations caused by the use of physical evolution curve of construction for disbursements projections related to the cost of building, the deviations related to failure in the projection of customer transfers, and the effects of complexity, uniqueness and term of projects in these projections.
2

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Marconi, Rodrigo Gibbin 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.
3

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Rodrigo Gibbin Marconi 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.

Page generated in 0.0809 seconds