Transposição de dados da tomografia computadorizada para a superfície de triangulação e compassoCoutinho Dias Filho, Luiz January 2004 (has links)
Made available in DSpace on 2014-06-12T16:26:33Z (GMT). No. of bitstreams: 2
arquivo5516_1.pdf: 9164280 bytes, checksum: 525669ea5725efbecd3e6672c0c3724e (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2004 / Realizou-se uma análise criteriosa da eficácia do método da triangulação e compasso em
transferir dados da tomografia computadorizada para a superfície da cabeça. Para tal, alvos
radiopacos foram fixos nas cabeças de cadáveres humanos; em seguida, cada espécimen foi
submetido à tomografia computadorizada e intentou-se a localização dos alvos por meio de
triangulação e compasso. Os alvos foram distribuídos em diferentes regiões com o fito de
averiguar se a posição interferiria com a acurácia do método. Como referenciais utilizaramse
tanto marcos anatômicos como marcadores radiopacos. Dois grupos foram delineados,
um com e outro sem inclinação do gantry do tomógrafo. Quando a tomografia foi realizada
sem inclinação do gantry, constataram-se erros de 2,1±1,7mm e 1,7±1,2mm ao serem
utilizados, respectivamente, marcos anatômicos e marcadores radiopacos; a análise
estatística demonstrou não haver diferença significativa entre tais medidas. A localização
dos alvos tornou-se menos exata à medida que a inclinação do gantry foi aumentada. A
posição dos alvos não interferiu na acurácia do método. Os cálculos demandaram
7,1±1,0min. Os fatores de erro foram analisados e a aplicabilidade do método foi
defendida, alegando-se o bom proveito de seu uso no posicionamento de craniotomias, na
efetivação de biópsias e na punção de cistos, hematomas e abscessos. Com respeito à
transferência de dados da tomografia computadorizada para a superfície da cabeça foi
demonstrado que o método da triangulação e compasso é tão eficaz quanto a
neuronavegação e um pouco menos que a estereotaxia convencional. Quando comparado a
outros métodos, foram nítidas as vantagens relativas à acurácia e exeqüibilidade. Ademais,
devem ser ressaltados o baixo custo do procedimento e o mínimo desconforto para o
paciente
|
2 |
Desvios lineares e angulares de implantes com guias prototipadas fixadas em modelos experimentais / Linear and angular deviations of implants placed with fixed stereolithographic drill guides in experimental modelsNovellino, Marcelo Michele 11 August 2011 (has links)
Considerando as dificuldades que ocorrem com a localização e o posicionamento de implantes e, ainda, o risco de deslocamento das guias, tomográfica e cirúrgica, durante os procedimentos de diagnóstico e cirúrgico, foi objetivo desta pesquisa avaliar, se a alternativa de introduzir dispositivos para retenção e suporte, nas guias da técnica de cirurgia guiada convencional, interfere na posição e inclinação de implantes no momento da sua colocação. Foram confeccionados 10 modelos simulando tecido ósseo, divididos aleatoriamente em 2 grupos: 5 com a guia tomográfica e cirúrgica da técnica convencional, denominado grupo controle (M); 5 com as guias fixadas a ortoimplantes modificados associados ao sistema de encaixe o ring, representando o grupo experimental (MI). A avaliação dos resultados foi pela sobreposição dos planejamentos virtuais (Implant Viewer), derivados de tomografias computadorizadas pré-cirúrgicas, com as realizadas após a colocação dos implantes. Os resultados obtidos mostraram que não houve diferenças estatisticamente significantes para os desvios angulares (Teste Tukey F= 1,06 e p= 0, 3124) e lineares (Teste ANOVA F = 2,54 e p = 0,11). No entanto, os valores angulares individuais do grupo experimental (MI), mostraram ser mais próximos entre si, com menor variabilidade, quando comparados ao grupo controle. Concluiuse, que o uso de ortoimplantes associados ao sistema de encaixe o ring, pode trazer benefícios à técnica da cirurgia guiada convencional, reduzindo as alterações de posicionamento dos implantes no momento da sua colocação. / Computer guided surgery is an excellent alternative to the proper insertion of implants in patients with an edentulous arch or a partially edentulous area and with appropriate quantity of bone. Considering the difficulties that occur with implants placement and the risk of displacement of radiographic and surgical template during the diagnostic and surgical procedures, the aim of this research was to assess if an alternative devices for retention of radiographic and surgical templates can bring benefits for a more accurate implant placement. Ten models made by a material that simulates bone tissue were randomly divided into 2 groups: 5 with the conventional radiographic and surgical guide, which was called control group (M); 5 with modified orthodontic implants that fixed the radiographic and the surgical templates, representing the experimental group (MI). The evaluation of the results was by matching virtual plans (Implant Viewer), derived from pre-operative cone-beam CT images, with post-operative ones to calculate the deviation between planned and installed implants. The results showed that there was no statistically significant differences for angular (Tukey F = 1.06 and p = 0, 3124) and linear deviations (test ANOVA F = 2.54 and p = 0.11). However, the individual angular values of experimental group (MI) showed to be closer to each other, with lower variability when compared to control group. It was concluded that the use of modified orthodontic implant with o ring attachment can bring benefits to conventional guided surgery technique, reducing changes in ideal implant position.
|
3 |
Desvios lineares e angulares de implantes com guias prototipadas fixadas em modelos experimentais / Linear and angular deviations of implants placed with fixed stereolithographic drill guides in experimental modelsMarcelo Michele Novellino 11 August 2011 (has links)
Considerando as dificuldades que ocorrem com a localização e o posicionamento de implantes e, ainda, o risco de deslocamento das guias, tomográfica e cirúrgica, durante os procedimentos de diagnóstico e cirúrgico, foi objetivo desta pesquisa avaliar, se a alternativa de introduzir dispositivos para retenção e suporte, nas guias da técnica de cirurgia guiada convencional, interfere na posição e inclinação de implantes no momento da sua colocação. Foram confeccionados 10 modelos simulando tecido ósseo, divididos aleatoriamente em 2 grupos: 5 com a guia tomográfica e cirúrgica da técnica convencional, denominado grupo controle (M); 5 com as guias fixadas a ortoimplantes modificados associados ao sistema de encaixe o ring, representando o grupo experimental (MI). A avaliação dos resultados foi pela sobreposição dos planejamentos virtuais (Implant Viewer), derivados de tomografias computadorizadas pré-cirúrgicas, com as realizadas após a colocação dos implantes. Os resultados obtidos mostraram que não houve diferenças estatisticamente significantes para os desvios angulares (Teste Tukey F= 1,06 e p= 0, 3124) e lineares (Teste ANOVA F = 2,54 e p = 0,11). No entanto, os valores angulares individuais do grupo experimental (MI), mostraram ser mais próximos entre si, com menor variabilidade, quando comparados ao grupo controle. Concluiuse, que o uso de ortoimplantes associados ao sistema de encaixe o ring, pode trazer benefícios à técnica da cirurgia guiada convencional, reduzindo as alterações de posicionamento dos implantes no momento da sua colocação. / Computer guided surgery is an excellent alternative to the proper insertion of implants in patients with an edentulous arch or a partially edentulous area and with appropriate quantity of bone. Considering the difficulties that occur with implants placement and the risk of displacement of radiographic and surgical template during the diagnostic and surgical procedures, the aim of this research was to assess if an alternative devices for retention of radiographic and surgical templates can bring benefits for a more accurate implant placement. Ten models made by a material that simulates bone tissue were randomly divided into 2 groups: 5 with the conventional radiographic and surgical guide, which was called control group (M); 5 with modified orthodontic implants that fixed the radiographic and the surgical templates, representing the experimental group (MI). The evaluation of the results was by matching virtual plans (Implant Viewer), derived from pre-operative cone-beam CT images, with post-operative ones to calculate the deviation between planned and installed implants. The results showed that there was no statistically significant differences for angular (Tukey F = 1.06 and p = 0, 3124) and linear deviations (test ANOVA F = 2.54 and p = 0.11). However, the individual angular values of experimental group (MI) showed to be closer to each other, with lower variability when compared to control group. It was concluded that the use of modified orthodontic implant with o ring attachment can bring benefits to conventional guided surgery technique, reducing changes in ideal implant position.
|