• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Quantitative analysis of surfactant deposits on human skin by liquid chromatography electrospray ionisation tandem mass spectrometry.

Massey, Karen A., Snelling, Anna M., Nicolaou, Anna January 2010 (has links)
No / Surfactants are commonly used as cleansing agents and yet there are concerns they may also have a role in skin irritation. Presently, the lack of suitable methods for quantitative and qualitative analysis of surfactant deposition on skin has hindered the in-depth investigation of such effects. Here, we report the application of reverse phase liquid chromatography electrospray ionisation mass spectrometry (LC/ESI-MS/MS) assays for two surfactants commonly used in consumer products, namely sodium lauryl ether sulphate (SLES) and laurylamidopropyl betaine (LAPB), to a baseline study aiming to assess deposition levels on human skin. The linearity of the assays was established at 3-20 ng, with coefficient of variation below 5%. Detection limits were 100 pg for LAPB and 1 ng for SLES; quantitation limits were 500 pg for LAPB and 2.5 ng for SLES. The baseline study was conducted using a panel of 40 healthy volunteers. Skin extract samples were taken in triplicate from forearms, using ethanol. SLES was detected on most volunteers, with 75% of them having SLES deposits in the range of 100-600 ng/cm2. LAPB was detected on the skin of all volunteers with 85% of them having deposit levels within the concentration range of 1-100 ng/cm2. These results demonstrate the extent to which commonly used surfactants remain on the skin during the day. The analytical methods reported here can be applied to the investigation of surfactants in relation to general skin condition and the development and optimisation of new consumer wash products. / EPSRC
2

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Tachibana, Arlene 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.
3

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Arlene Tachibana 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.

Page generated in 0.1045 seconds