• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Imagerie rapide par IRM pour le monitorage des thermothérapies

Dragonu, Iulius 08 December 2009 (has links)
L’hyperthermie guidée par IRM permet l’ablation thermique des tumeurs, l’activation de l’expression d’un transgène sous contrôle d’un promoteur thermo-sensible ainsi que le dépôt local de médicaments à l’aide de nanovéhicules sensibles à la température ou à la pression locale. L’imagerie de température par IRM, basée sur la technique du décalage de la fréquence de résonance du proton permet le monitorage des interventions d’hyperthermie. Les procèdes interventionnels guides par IRM sur cible mobile requièrent des séquences d’imagerie rapides afin d’obtenir des images de phases ayant une résolution spatio-temporelle élevée. Nous avons démontré l’efficacité de l’association des méthodes adaptatives d’imagerie parallèle telles que TSENSE et TGRAPPA et de la méthode multi-référence de l’atlas de mouvement afin de compenser les variations du champ magnétique induites par les organes en mouvement. Les procédés interventionnels guides par IRM sont basés sur des séquences d’imagerie rapides capables de fournir des images en temps-réel ayant une relation précise entre la position de la cible représentée dans l’image et sa vraie position spatiale. Les séquences écho-planar sont très rapides mais possèdent des distorsions géométriques. Nous avons proposé une méthode de correction des distorsions des images EPI. Cette technique est basée sur des approches existantes utilisant l’acquisition de deux images EPI ayant deux temps d’écho différents. L’efficacité de la méthode proposée a été démontrée pour une expérience de thermométrie par IRM. La rapidité du traitement des données, associée à une faible diminution de la rapidité d’acquisition, rend cette méthode particulièrement adaptée pour les procédés interventionnels guides par IRM. La perfusion sanguine, la diffusion thermique ainsi que le coefficient d’absorption des ondes acoustiques ou électromagnétiques déterminent la distribution de la température durant les procédés interventionnels. Certaines tumeurs ont des taux de perfusion élevés conduisant à une évacuation importante de la chaleur et par conséquent, un refroidissement rapide de la cible. Cet effet réduit la température maximale atteinte pour une puissance donne et peut conduire à des zones d’ablation plus petites réduisant ainsi l’efficacité de l’intervention. La connaissance précise des paramètres thermiques du tissu peut aider à la planification des procédés interventionnels. Dans ce but, nous avons proposé une méthode permettant la détermination précise des paramètres cités précédemment. / MR-guided HIFU-induced hyperthermia allows for thermal ablation of tumors, for gene therapy by thermal induction of transgenic expression (based on a thermo-sensitive promoter) and for local drug delivery using thermo-sensitive liposomes. These applications require accurate temperature measurement during the therapeutic intervention. Dynamic MR-temperature imaging based on the proton resonance frequency shift technique allows monitoring the local temperature evolution during hyperthermia. MR-guided thermotherapy on moving organs requires imaging sequences providing phase images with high temporal and spatial resolution. We demonstrated the feasibility of combining adaptive parallel imaging techniques such as TSENSE or TGRAPPA with the atlas-based multi-baseline method for compensating the magnetic field variations produced by moving organs during the respiratory cycle. Many MR-guided interventional procedures rely on real-time imaging sequences for providing precise relations between the target position in the image and the true position in the scanner. Although echo-planar imaging (EPI) sequences are very fast, they are prone to geometric distortions. For correcting these distortions, we proposed a real-time correction method by applying existing approaches based on a dual EPI acquisition with varying echo times. It is demonstrated that this method works well in combination with MR-thermometry for guiding thermal therapies. Short data-processing times as well as a small penalty in acquisition speed make this method well-adapted for MR-guided interventions. Local blood perfusion, thermal conductivity and the absorption coefficient of acoustic or electro-magnetic waves determine the temperature distribution in living tissue. Some tumors have high perfusion rates resulting in considerable heat evacuation. This effect reduces the maximal temperature increase achievable for a given deposited energy and produces smaller ablation zones, which can impair the efficiency of the therapeutic procedure. A method for accurately estimating the above mentioned tissue parameters, was presented. This method could thus be useful in quantifying the influence of perfusion during thermal interventions.
2

Modeling Optical Properties of Combustion Soot emitted in the Troposphere / Modélisation de la réponse optique des particules de suie émises dans la Troposphère

Garcia Fernandez, Carlos 26 November 2015 (has links)
Ce travail concerne la modélisation, à l’échelle moléculaire, de l’interaction entre des nanoparticules carbonées et le rayonnement électromagnétique. Le but est d’aider à la compréhension des propriétés optiques des particules de suie afin de mieux quantifier l’influence des suies sur l’atmosphère et le climat. L’étude de l’interaction rayonnement/particules de suie fraîche a été effectuée par la méthode PDI ; il a été montré que : i) le coefficient d’absorption massique (MAC) des particules de suie dépend de la répartition des atomes dans la particule et de leurs liaisons, en particulier entre 200 et 350 nm ; ii) le MAC diffère selon que le cœur de la particule carbonée est occupé ou non par des plans graphitiques ; iii) un modèle analytique n’est pas adapté pour calculer le MAC d’une nanoparticule carbonée présentant des défauts structuraux. De plus, des méthodes de chimie quantique ont été utilisées pour caractériser le vieillissement des suies. Les résultats montrent que : i) NO, Cl, et HCl sont physisorbées sur une surface carbonée parfaite alors que sur une surface défective, ces espèces sont chimisorbées et conduisent à une modification de la surface ; ii) la présence de Cl conduit à un piégeage fort des molécules d’eau supérieur à celui obtenu lorsqu’un site oxygéné est présent sur la surface carbonée, expliquant ainsi le caractère hydrophile des suies émises lors d’incendies dans des milieux industriels. Enfin, la méthode PDI a été appliquée au calcul de la polarisabilité de HAP afin d’interpréter des spectres d’absorption des grains carbonés du milieu interstellaire, en incluant des molécules pour lesquelles aucune donnée n’était actuellement disponible. / This work concerns the modeling, at the molecular level, of the interaction between carbonaceous particles of nanometric size and the electromagnetic radiation. The goal is to improve our understanding of the optical properties of soot particles, to better quantify the influence of soot on the atmosphere and on climate change. The study of the interaction between radiation and fresh soot particles was carried out using the point dipole interaction method; it has been shown that: i) the mass absorption coefficient (MAC) of these soot nanoparticles may significantly depend on their atomistic details, especially between 200 and 350 nm; ii) the MAC depends on whether the heart of the carbonaceous particle is occupied or not by graphite planes; iii) an analytical model is not suitable for calculating the MAC of carbonaceous nanoparticles having structural defects. In addition, quantum chemical methods have been used to characterize the ageing of soot. The results obtained are i) NO, Cl, and HCl are physisorbed on a perfect carbonaceous surface whereas on a defective surface, these species are chemisorbed and lead to a modification of the surface; ii) on a carbonaceous surface, the presence of adsorbed Cl atoms leads to a strong trapping of the surrounding water molecules. This may be related to the highly hydrophilic nature of soot emitted during fires in industrial environments. Finally, the PDI method was applied to calculate the polarizability of PAHs to help at interpreting the absorption spectra of carbonaceous grains in the interstellar medium, including molecules for which no data was currently available.

Page generated in 0.1321 seconds