Verificação dos valores dos coeficientes de convecção do ar no exterior de edifícios no estado da ParaíbaPorto, Eduardo Figueiredo 05 March 2007 (has links)
Submitted by Viviane Lima da Cunha (viviane@biblioteca.ufpb.br) on 2017-07-18T13:27:53Z
No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5) / Made available in DSpace on 2017-07-18T13:27:53Z (GMT). No. of bitstreams: 1
arquivototal.pdf: 2894407 bytes, checksum: 993603497277207e108988a17bd6d3b2 (MD5)
Previous issue date: 2007-03-05 / This research investigated and analysed the characteristics and peculiarities of wind flowing
that take place in the state of Paraiba in order to verify the local values for the air coefficients
of external convection (hc’s), based in non-dimensional numbers like Prandlt, Reynolds and
Nusselt, and empirical correlations as suggested by Hilpert. These correlations are widely
used and the results demonstrate that the verified values significantly differ from the ones
currently recommended by the Brazilian norms concerning the thermal performance of
buildings and the basic parameters of projects for central air-conditioners. The results
highlighted the need to review these coefficients and take into consideration the
interrelationship between the standards of local ventilation and construction regulations when
calculating the thermal conditioning of buildings in order to minimize environmental impact
and improve energy performance of buildings, which will reduce costs. / Este trabalho investigou e analisou as características e as condições de escoamento dos ventos
que ocorrem no estado da Paraíba, a fim de determinar valores locais para os coeficientes de
convecção do ar externo (hc’s), com base nos números adimensionais de Prandlt, Reynolds e
Nusselt, e correlações empíricas com as sugeridas por Hilpert, que são largamente utilizadas,
cujos resultados demonstraram que os valores verificados diferem significativamente dos
valores atualmente recomendados palas Normas Brasileiras referentes ao desempenho térmico
de edificações, e aos parâmetros básicos de projeto de centrais de ar-condicionado,
conduzindo à necessidade de se reverem tais coeficientes e considerarem as inter-relações
entre o padrão de ventilação local e o de ocupação do solo, quando do cálculo de
acondicionamento térmico de edifícios, para se minimizar os impactos ambientais, otimizar o
desempenho energético de edificações, aumentando a economia de energia reduzindo custos.
|
2 |
Análise híbrida numérico-experimental da troca de calor por convecção forçada em aletas planas / Numerical-experimental hybrid analysis of heat change by forced convection in plana finsSilva, Maico Jeremia da 28 July 2015 (has links)
Made available in DSpace on 2016-12-12T20:25:12Z (GMT). No. of bitstreams: 1
Maico Jeremias da Silva.pdf: 5502697 bytes, checksum: 292822b79334828b19d2d99087aae96b (MD5)
Previous issue date: 2015-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work discusses the behaviour of the convection heat transfer coefficient in plane fins with variation of air flow velocity and fin spacing. The differential equation that governs heat transfer in fins is discretized by the finite volume method, which enables computation of the fin thermal characteristics, such as temperature distribution, heat transfer and fin efficiency. The determination of the convection coefficient, important parameter for thermal analysis, is performed by applying a heuristic optimization method, known as Particle Swarm Optimization, which combines data measured from experimental analysis conducted in wind tunnel with the aforementioned heat transfer numerical approximation of fins. / Este trabalho analisa os efeitos da velocidade do escoamento de ar e do espaçamento entre aletas no coeficiente de convecção forçada sobre as superfícies de aletas planas. As equações diferenciais que definem a transferência de calor em aletas são discretizadas pela técnica de volumes finitos possibilitando a determinação das características térmicas da aleta, tais como perfil de temperatura, calor transferido e eficiência térmica. A determinação do coeficiente de convecção, parâmetro fundamental para análises térmicas, é realizada mediante a aplicação de um método de otimização heurístico, conhecido como Método do Enxame de Partículas, que combina os dados obtidos da análise experimental realizada em túnel de vento com a aproximação numérica da troca de calor na aleta descrita acima
|
Page generated in 0.0973 seconds