• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • 51
  • 13
  • 11
  • 7
  • 4
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 230
  • 52
  • 48
  • 42
  • 39
  • 39
  • 38
  • 38
  • 35
  • 32
  • 30
  • 29
  • 29
  • 27
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Padronização dos radionuclídeos F-18 e In-111 e determinação dos coeficientes de conversão interna total para o In-111 em sistema de coincidência por software / Standardization of radionuclides F-18 and In-111 and determination of total internal coefficient of In-111 in a software coincidence system

Matos, Izabela Teles de 14 March 2014 (has links)
O presente trabalho descreve a metodologia para a padronização dos radionuclídeos 111In e 18F e a determinação dos Coeficientes de Conversão Interna do 111In em Sistema de Coincidência por Software (SCS). O 111In decai com uma meia-vida de 2,8 dias por processo de captura eletrônica seguido por emissão de raios gama concorrendo com os elétrons da conversão interna. O 18F é um emissor de pósitrons de meia-vida curta (1,8 h), usado em Medicina Nuclear. As soluções radioativas usadas neste trabalho foram fornecidas pelo Centro de Radiofarmácia do IPEN e as massas determinadas pela técnica do picnômetro. As medidas foram feitas utilizando o Sistema de Coincidência 4πβ-γ constituído por um contador proporcional de geometria 4π a gás fluente e um semicondutor HPGe, acoplado a este sistema foi utilizado um sistema digital denominado de SCS com vantagem de obtenção da curva de extrapolação em uma única medida. A atividade do 111In foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional usando absorvedores externos em ambos os lados das fontes. Os valores dos Coeficientes de Conversão Interna Total foram determinados selecionando duas janelas de raios gama (175 keV e 245 keV). A atividade do 18F foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional utilizando a discriminação eletrônica. O código de simulação Monte Carlo ESQUEMA versão 9 foi usado para simular a extrapolação da curva da eficiência do 18F, considerando as características do esquema de desintegração e todos os detalhes geométricos do sistema de detecção. / This paper describes the methodology for standardization of radionuclides 111In and 18F and the determination of Total Internal Coefficients of 111In by means of a software coincidence system (SCS). The 111In decays with a half-life of 2.8 days by the electron capture process followed by gamma rays emission competing with internal conversion electrons. The 18F is a positron emitter with a short halflife (1.8 h), used in Nuclear Medicine. The radioactive solutions were provided by the Center for Radiopharmacy IPEN and the masses determined by pycnometer technique. The measurements were made using a Coincidence System 4πβ-γ consisting of a proportional counter in 4π geometry fluent gas and a HPGe semiconductor, coupled to the system was used a digital system called SCS with the advantage of obtaining the extrapolation curve in a single measurement. The activity of 111In was achieved by means of the linear extrapolation technique of the proportional counter efficiency using external absorbers on both sides of the sources. The values of the Total Internal Coefficients were determined selecting the two windows of gamma rays (175 keV and 245 keV). The activity of 18F was determined by means of the linear extrapolation, using electronic discrimination. The Monte Carlo simulation code ESQUEMA version 9 was used to simulate the efficiency curve extrapolation of the 18F, considering the characteristics of the system, the decay scheme of disintegration and all geometric details of the detection system.
12

Padronização dos radionuclídeos F-18 e In-111 e determinação dos coeficientes de conversão interna total para o In-111 em sistema de coincidência por software / Standardization of radionuclides F-18 and In-111 and determination of total internal coefficient of In-111 in a software coincidence system

Izabela Teles de Matos 14 March 2014 (has links)
O presente trabalho descreve a metodologia para a padronização dos radionuclídeos 111In e 18F e a determinação dos Coeficientes de Conversão Interna do 111In em Sistema de Coincidência por Software (SCS). O 111In decai com uma meia-vida de 2,8 dias por processo de captura eletrônica seguido por emissão de raios gama concorrendo com os elétrons da conversão interna. O 18F é um emissor de pósitrons de meia-vida curta (1,8 h), usado em Medicina Nuclear. As soluções radioativas usadas neste trabalho foram fornecidas pelo Centro de Radiofarmácia do IPEN e as massas determinadas pela técnica do picnômetro. As medidas foram feitas utilizando o Sistema de Coincidência 4πβ-γ constituído por um contador proporcional de geometria 4π a gás fluente e um semicondutor HPGe, acoplado a este sistema foi utilizado um sistema digital denominado de SCS com vantagem de obtenção da curva de extrapolação em uma única medida. A atividade do 111In foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional usando absorvedores externos em ambos os lados das fontes. Os valores dos Coeficientes de Conversão Interna Total foram determinados selecionando duas janelas de raios gama (175 keV e 245 keV). A atividade do 18F foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional utilizando a discriminação eletrônica. O código de simulação Monte Carlo ESQUEMA versão 9 foi usado para simular a extrapolação da curva da eficiência do 18F, considerando as características do esquema de desintegração e todos os detalhes geométricos do sistema de detecção. / This paper describes the methodology for standardization of radionuclides 111In and 18F and the determination of Total Internal Coefficients of 111In by means of a software coincidence system (SCS). The 111In decays with a half-life of 2.8 days by the electron capture process followed by gamma rays emission competing with internal conversion electrons. The 18F is a positron emitter with a short halflife (1.8 h), used in Nuclear Medicine. The radioactive solutions were provided by the Center for Radiopharmacy IPEN and the masses determined by pycnometer technique. The measurements were made using a Coincidence System 4πβ-γ consisting of a proportional counter in 4π geometry fluent gas and a HPGe semiconductor, coupled to the system was used a digital system called SCS with the advantage of obtaining the extrapolation curve in a single measurement. The activity of 111In was achieved by means of the linear extrapolation technique of the proportional counter efficiency using external absorbers on both sides of the sources. The values of the Total Internal Coefficients were determined selecting the two windows of gamma rays (175 keV and 245 keV). The activity of 18F was determined by means of the linear extrapolation, using electronic discrimination. The Monte Carlo simulation code ESQUEMA version 9 was used to simulate the efficiency curve extrapolation of the 18F, considering the characteristics of the system, the decay scheme of disintegration and all geometric details of the detection system.
13

Determinação da taxa de desintegração de TC 99M e IN 111 em sistemas de coincidências / Disintegration rate of Tc -99m and In -111 radioactive solutions in coincidence systems

Andréia Barreto de Brito 16 November 2011 (has links)
Este trabalho apresenta os métodos de padronização de 111In e 99mTc, em sistemas de coincidências 4πβ-γ. O 111In foi produzido em cíclotron pela reação 111Cd(p, n)111In; decai com uma meia vida de 2,8 dias pelo processo de captura eletrônica populando os níveis excitados do 111Cd, emitindo raios gama de 171 keV e 245 keV. O 99mTc decai com uma meia vida de 6,007 h por transição isomérica do decaimento radioativo do 99Mo . A padronização do 111In foi feita no sistema 4πβ-γ constituído de um detector proporcional em geometria 4π acoplado a dois cristais cintiladores de NaI(Tl) com eletrônica convencional. A radiação gama selecionada para medida em coincidência foi de (171 + 245) keV. A escolha da janela gama foi baseada na análise da previsão da curva de extrapolação obtida na simulação de Monte Carlo. A padronização do 99mTc foi feita num sistema 4πβ-γ usando um contador proporcional de janela fina acoplado a um cristal de cintilação NaI (Tl). A eficiência beta foi variada por discriminação eletrônica, usando sistema de coincidências por software (SCS). A padronização do 99mTc foi feita pela seleção de dois intervalos gama, um no pico de absorção total de 140 keV e outro no pico de absorção total dos raios X de 20 keV. O resultado da atividade experimental de duas soluções de 111In concorda com o resultado obtido pela simulação de Monte Carlo. As atividades experimentais do 99mTc para os dois intervalos gama selecionados estão de acordo dentro da incerteza experimental, indicando que a metodologia adotada é adequada. / The 111In and 99mTc standardization in a 4πβ-γ coincidence system is described. The 111In was produced by the reaction of 111Cd (p, n) 111In in the cyclotron. The 111In decays with a half life of 2.8 days by electron capture process, populating the excited levels of 111Cd, emitting two main gamma rays with energies of 171 keV and 245 keV. The 99mTc decay with a half life of 6.007 h for isomeric transition, from the radioactive decay of 99Mo . 111In standstand ardization was carried out in a 4πβ-γ system, consisted of a system, consisted of a system of a gas flow proportional counter with 4flow proportional counter with 4π geometry coupled to a pair of NaI(Tl) scintillation counter with conventional electronics. The gamma window was set comprising the (171 keV + 245 keV) total absorption energy peaks. The choice of the window was based on the analysis of the extrapolation curves prediction, obtained by Monte Carlo simulation. The 99mTc standardization has been accomplished by the 4πβ-γ coincidence method using a thin window proportional counter in a 4π geometry coupled to a single NaI(Tl) scintillation counter. The beta efficiency was varied by electronic discrimination using a software coincidence counting system (SCS). Two windows were selected for the gamma channel: one at 140 keV gamma ray and the other at 20 keV X ray total absorption peaks. The result of the experimental activity of 111In two solutions agree with the results obtained by Monte Carlo simulation. The experimental activities of 99mTc for the two gamma windows are in agreement within the experimental uncertainty, indicating that the adopted methodology is adequate.
14

Relative and equivariant coincidence theory /

Guo, Jianhan, January 1996 (has links)
Thesis (Ph. D.), Memorial University of Newfoundland, 1999. / Bibliography: p. 148-150.
15

Impossible knowledge : extraordinary simultaneous experience narratives as vernacular forms of philosophy /

Condon, Eileen M., January 1999 (has links)
Thesis (Ph.D.)--Memorial University of Newfoundland, 1999. / Bibliography: leaves [368]-387.
16

Medida absoluta da atividade e determinacao da taxa de emissao gama por decaimento do sup 126I

FONSECA, KATIA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:58Z (GMT). No. of bitstreams: 1 04723.pdf: 2889470 bytes, checksum: 948ecd834c1d56f6fcb3cab55f26f0d8 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
17

Medida absoluta da atividade e determinacao da taxa de emissao gama por decaimento do sup 126I

FONSECA, KATIA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:58Z (GMT). No. of bitstreams: 1 04723.pdf: 2889470 bytes, checksum: 948ecd834c1d56f6fcb3cab55f26f0d8 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
18

Some general convergence theorems on fixed points

Panicker, Rekha Manoj January 2014 (has links)
In this thesis, we first obtain coincidence and common fixed point theorems for a pair of generalized non-expansive type mappings in a normed space. Then we discuss two types of convergence theorems, namely, the convergence of Mann iteration procedures and the convergence and stability of fixed points. In addition, we discuss the viscosity approximations generated by (ψ ,ϕ)-weakly contractive mappings and a sequence of non-expansive mappings and then establish Browder and Halpern type convergence theorems on Banach spaces. With regard to iteration procedures, we obtain a result on the convergence of Mann iteration for generalized non-expansive type mappings in a Banach space which satisfies Opial's condition. And, in the case of stability of fixed points, we obtain a number of stability results for the sequence of (ψ,ϕ)- weakly contractive mappings and the sequence of their corresponding fixed points in metric and 2-metric spaces. We also present a generalization of Fraser and Nadler type stability theorems in 2-metric spaces involving a sequence of metrics.
19

Design and Testing of a Coincidence System

Barnes, W. L., Jr. 01 1900 (has links)
This paper is concerned with the design, testing and performance of a coincidence system, the proposed North Texas State College accelerator.
20

appreciating coincidence

Martin, Julia Frances 03 February 1999 (has links)
architects have the capacity to make invaluable connections between the present and the past - connections which can potentially fortify and enrich contemporary culture. carefully considered subtle and substantial interventions can infuse seemingly defunct existent constructions with a new vitality and provide the contemporary world with a rich and intricate new architecture. / Master of Architecture

Page generated in 0.0419 seconds