Spelling suggestions: "subject:"columns, concrete desting"" "subject:"columns, concrete ingesting""
1 |
Seismic performance of full-scale reinforced concrete columnsBae, Sungjin 28 August 2008 (has links)
Not available / text
|
2 |
Non-destructive evaluation of gravity load carrying capacity and lateral load damage of reinforced concrete slab-column connectionsArgudo, Jaime Fernando 28 August 2008 (has links)
Not available / text
|
3 |
The behaviour of reinforced concrete cantilever columns under lateral impact loadLoedolff, Matthys Johannes 12 1900 (has links)
Microreproduction of original thesis. / Thesis (PhD)--Stellenbosch University, 1990. / Some digitised pages may appear illegible due to the condition of the original microfiche copy. / ENGLISH ABSTRACT: see item for full text / AFRIKAANSE OPSOMMING: sien item vir volteks.
|
4 |
Full-range analysis of reinforced concrete members and framesLam, Yuet-kee, Jeffery., 林悦基. January 2009 (has links)
published_or_final_version / Civil Engineering / Doctoral / Doctor of Philosophy
|
5 |
Experimental investigation of steel tubed reinforced concrete columnsMachado, Rafael Ignacio 05 1900 (has links)
No description available.
|
6 |
Slab-column connections with misplaced reinforcementLai, Wai Kuen (Wai Kuen Frank) January 1983 (has links)
No description available.
|
7 |
Experimental research on the buckling behaviour of slender prestressed concrete columnsLaszlo, Gyorgy January 1966 (has links)
Thirty full scale prestressed concrete struts all having a slenderness ratio of L/D = 40 were tested with three different eccentricities. Stress-strain curves of the corresponding test cylinders were established and the Young's Moduli evaluated. The specimens were fabricated with different percentages of prestressing steel ranging from 0.23 to 1.20%. The initial prestressing forces were set to obtain a final prestress of 140,000 psi in all specimens. The dimensions of the struts, and the quality and manufacturing process of the concrete, were kept constant. Special adjustable supporting devices simulated ideal hinged conditions. The struts were tested to their ultimate capacity and their critical buckling loads were evaluated.
The tests proved that, provided the column is made of high quality concrete, the critical load values can be obtained by using Euler's fundamental formula, and these values are independent of the amount of prestressing. For eccentrically loaded struts maximum stresses from a modified secant formula, incorporating effect of prestressing, were compared with those calculated on basis of observed deflections.
According to the test results the secant modulus corresponding to the average compressive stress should be used in Euler's formula. / Applied Science, Faculty of / Civil Engineering, Department of / Graduate
|
8 |
Slab-column connections with misplaced reinforcementLai, Wai Kuen (Wai Kuen Frank) January 1983 (has links)
No description available.
|
9 |
Physical models in fire study of concrete structuresNg, Ah Book January 1988 (has links)
No description available.
|
10 |
Physical models in fire study of concrete structuresNg, Ah Book January 1988 (has links)
No description available.
|
Page generated in 0.0974 seconds