Spelling suggestions: "subject:"colunas metálicos"" "subject:"alunas metálicos""
1 |
Análise teórico-experimental de placas de base de colunas metálicas tubulares.Possato, Gisele da Silva Novo January 2004 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-02-15T15:27:06Z
No. of bitstreams: 1
DISSERTAÇÃO_AnáliseTeóricoExperimentalPlacas.pdf: 2526440 bytes, checksum: c04eb7eb94588d9b650a13db5d9702ba (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-02-15T16:00:07Z (GMT) No. of bitstreams: 1
DISSERTAÇÃO_AnáliseTeóricoExperimentalPlacas.pdf: 2526440 bytes, checksum: c04eb7eb94588d9b650a13db5d9702ba (MD5) / Made available in DSpace on 2016-04-12T17:51:01Z (GMT). No. of bitstreams: 1
DISSERTAÇÃO_AnáliseTeóricoExperimentalPlacas.pdf: 2526440 bytes, checksum: c04eb7eb94588d9b650a13db5d9702ba (MD5)
Previous issue date: 2004 / Neste trabalho, é apresentado um estudo experimental para analisar a resistência
de placas de base de colunas formadas por tubos metálicos circulares. O programa
experimental envolve ensaios em colunas curtas com placas de base conectadas através
de chumbadores a uma base de concreto com resistência controlada. A excentricidade
de carregamento é um parâmetro crítico para a análise sendo observados nos ensaios os
modos de colapso obtidos.
Foram ensaiados quatro protótipos em laboratório, e o estudo experimental foi
desenvolvido de forma a analisar a distribuição de tensões nas placas de base à medida
que a coluna recebe carga excêntrica. Foram posicionados extensômetros em toda a
placa de base para leitura das deformações, e com os valores das deformações foram
obtidas as tensões nas placas.
É apresentada uma abordagem teórica de cálculo de placa de base de colunas
tubulares, através das expressões analíticas encontradas em normas de cálculo,
destacando EUROCODE3 (1992), AISC (1997) e NBR8800 (1986). Foram realizadas
análises teóricas nos protótipos ensaiados de forma a comparar os valores encontrados
nos ensaios realizados e as expressões analíticas das normas de cálculo de placas de
base. A partir dessas comparações concluiu-se que as formulações propostas pela
maioria dos autores são muito conservadoras. Dessa forma propõe-se uma alternativa de
cálculo onde foram obtidos resultados compatíveis com os resultados experimentais. _________________________________________________________________________________ / ABSTRACT: In this work, an experimental study is presented to analyze the resistance of
plates of base of columns formed by hollow steel tubes. The experimental program
involves rehearsals in stub columns with base plates connected by ancorbolts in
concrete foundation with controlled resistance. The eccentricity load is a critical
parameter for the analysis being observed in the rehearsals the collapse manners
obtained.
Four prototypes were rehearsed at laboratory, and the experimental study was
developed from way to analyze the distribution of tensions in the base plates as the
column receives eccentric load. Straingages were positioned in the whole base plate for
reading of the deformations, and with the values of the deformations they were obtained
the tensions in the plates.
A theoretical approach of calculation of plate of base of tubular columns is
presented, through the analytical expressions found in calculation norms, detaching
EUROCODE3 (1992), AISC (1997) and NBR8800 (1986). Theoretical analyses were
accomplished in the rehearsed prototypes in way to compare the values found in the
accomplished rehearsals and the analytical expressions of the norms of calculation of
base plates. In short, the formulations proposed by most of the authors are conservative.
In that way calculation alternatives are proposed being obtained compatible results with
the experimental results.
|
2 |
Análise do comportamento dos pilares mistos considerando a utilização de conectores de cisalhamentoBianchi, Flavia Regina 08 September 2002 (has links)
Made available in DSpace on 2016-12-23T14:05:56Z (GMT). No. of bitstreams: 1
01-CapaAgradecimentos.pdf: 16794 bytes, checksum: 5be902fb6abdc744587159866db9f2a5 (MD5)
Previous issue date: 2002-09-08 / The steel-concrete composite structures are systems that involve the interaction of structural steel components with concrete elements to resist external forces. This interaction between steel and concrete should be guaranteed to ensure that loads are supported. As such, adhesion tensions between the concrete and the steel should not be exceeded. In cases where they are, the use of shearing connectors becomes necessary. The influence of the use of shearing connectors in composite columns is greatly undervalued
in the majority of scientific papers, with its use recommended only in situations of high vibration. In this paper, the behavior of composite columns is analyzed with the use of shearing
connectors taken into consideration through numerical analysis using Ansys programming and based on the finite element method. To achieve this, an ideal model that reflects the situation was adopted permitting as study of the element, the load, and the contour conditions adequate for usage.
Composite columns with and without shearing connectors were modeled. A load was applied to each model with varying eccentricity to create an interaction curve defining the moment of flexion in function of normal force. From the interactive curves that were constructed, the importance of the use of shearing connectors was analyzed. This analysis compares results to data supplied by EUROCODE 4(1994) and the influence of different values for maximum adhesion tension of the last load of the composite column. / As estruturas mistas de aço e concreto são sistemas que envolvem o comportamento interativo de componentes de aço estrutural com elementos de concreto para resistir às ações externas. Essa interação entre o aço e o concreto deve ser garantida para que haja o suporte de cargas. Para tanto, as tensões de aderência entre o concreto e o aço não devem ser excedidas. Caso isso aconteça, é então necessária a utilização dos conectores de cisalhamento. A influência da utilização dos conectores de cisalhamento nos pilares mistos é desprezada na maioria dos trabalhos científicos, sendo recomendando o seu uso somente em situações de grandes vibrações. No presente trabalho é analisado o comportamento dos pilares mistos, considerando a utilização dos conectores de cisalhamento por meio de análises numéricas feitas no programa Ansys, baseado no método dos elementos finitos. Para isso, foi adotada a modelagem ideal que retrate a situação, fazendo-se o estudo do elemento, do carregamento e das condições de contorno adequados à utilização. Foram modelados os pilares mistos utilizando os conectores de cisalhamento e sem a utilização dos conectores de cisalhamento. Para cada modelagem a carga foi aplicada
variando a excentricidade, de modo que a curva de interação momento fletor em função do esforço normal fosse construída.
A partir das curvas de interação construídas foi analisada a importância da utilização dos conectores de cisalhamento, comparando os resultados com os dados fornecidos pelo
EUROCÓDIGO 4 (1994) e a influência de diferentes valores da tensão máxima de aderência na carga última do pilar misto.
|