• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 29
  • 8
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 43
  • 26
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da estrutura porosa de empacotamento compacto aleatório de esferas rígidas.

SANTANA, D. W. O. 29 September 2017 (has links)
Made available in DSpace on 2018-08-01T21:59:24Z (GMT). No. of bitstreams: 1 tese_11430_Dissertação final Deivid Wilson Oliveira Santos.pdf: 3557089 bytes, checksum: 1e479b0b6461bcfe5a25b3ff9df4d107 (MD5) Previous issue date: 2017-09-29 / No início, o estudo dos empacotamentos compactos de corpos tinha a simples função de otimizar espaço físico. Os estudos pioneiros obtiveram grandes resultados em empacotamento de corpos com geometrias simples, proporcionado a utilização deste estudo para modelar a nascente estrutura atômica. Os estudos foram avançando até o ponto de serem utilizados para modelar estruturas complexas, como aglomerados de células e materiais heterogêneos porosos, sendo este último foco deste trabalho. Para esse objetivo, construímos empacotamentos compactos aleatórios de esferas rígidas, gerados por algoritmos computacionais comumente reportados na literatura. Nossos estudos caracterizaram do ponto de vista estatístico o meio poroso formado pelas regiões vazias do empacotamento aleatório de esferas. Seus descritores estatísticos, a função de autocorrelação estatística de dois-pontos 𝑆2(𝑟) e distribuição de tamanho de poros foram calculados e analisados. Particular ênfase foi dada ao cálculo da entropia da distribuição de tamanhos de poros e a sua interpretação em termos da proximidade do sistema ao limite de máxima densidade. Por último, fizemos a reconstrução da função de autocorrelação calculada numa rocha natural da formação Lagoa-Salgada, a partir de medidas estatísticas realizadas sobre um empacotamento compacto aleatório de esferas interpenetráveis. Este último ponto estudado é relevante no sentido que o estudo mostrou que é possível reconstruir, mesmo que parcialmente, a estrutura porosa de um material poroso natural. De forma geral, os resultados encontrados neste trabalho reproduziram resultados abordados na literatura sobre a caracterização morfológica de meios heterógenos, além de fornecer novas ideias acerca da possibilidade de utilizar ferramentas estatísticas visando reproduzir a morfologia porosa observada em rochas naturais.
2

Wavelets monocíclicas de suporte compacto construídas a partir de distribuições beta

ARAÚJO, Giovanna Angelis Andrade de January 2007 (has links)
Made available in DSpace on 2014-06-12T17:39:28Z (GMT). No. of bitstreams: 2 arquivo6902_1.pdf: 3068620 bytes, checksum: eb2722910d045ddc14f0488856268b0c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Esta dissertação se propõe a investigar a representação de sinais no plano tempofreq üência e, mais especificamente, os problemas relativos à resolução de sinais. O princípio da incerteza de Gabor-Heisenberg para sinais e wavelets é analisado criteriosamente. Versões de Gnedenko-Kolmogorov do tipo Teorema Central do Limite são avaliadas, procurando elucidar sua relevância no contexto da resolução de sinais. Finalmente, o conceito de derivada Blur é usado para propor uma nova família de wavelets - as wavelets beta - construídas a partir de distribuições beta de probabilidade. Essas wavelets são atrativas por terem suporte compacto, são monocíclicas, possuem descrição analítica e podem ser consideradas como uma generalização suavizada das wavelets de Haar. Sua relevância decorre do Teorema Central do Limite aplicado a wavelets de suporte compacto. Campos promissores para aplicação destas wavelets são mencionado
3

O design compacto : critérios de design para uma vida em mudança

Vasconcelos, Maria Teresa Alves de Magalhães e January 2009 (has links)
Tese de mestrado. Design Industrial. Faculdade de Engenharia. Universidade do Porto, Escola Superior de Artes e Design de Matosinhos. 2009
4

Um estudo sobre a classificação topológica das superfícies / A study of the topological classification of surfaces

Sousa, Ana Flávia Mariano de [UNESP] 10 October 2016 (has links)
Submitted by ANA FLAVIA MARIANO DE SOUSA null (flavinha455@hotmail.com) on 2016-10-17T20:55:50Z No. of bitstreams: 1 Dissertação final imprimir.pdf: 3125220 bytes, checksum: 761d821c6466a0e1358b2a44c7b1c9f2 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-10-20T19:22:54Z (GMT) No. of bitstreams: 1 sousa_afm_me_rcla.pdf: 3125220 bytes, checksum: 761d821c6466a0e1358b2a44c7b1c9f2 (MD5) / Made available in DSpace on 2016-10-20T19:22:54Z (GMT). No. of bitstreams: 1 sousa_afm_me_rcla.pdf: 3125220 bytes, checksum: 761d821c6466a0e1358b2a44c7b1c9f2 (MD5) Previous issue date: 2016-10-10 / Nesse trabalho, consideramos o conceito de variedades topológicas. Porém, nos especializamos nas variedades conexas de dimensão 2, as chamadas superfícies. Nosso objetivo é o estudo da classificação topológica das superfícies compactas. Para isto, enunciamos e demonstramos o Teorema de classificação das superfícies compactas. Desta maneira, mostramos que toda superfície compacta orientável é homeomorfa à esfera ou a uma soma conexa de toros, e que toda superfície compacta não orientável é homeomorfa a uma soma conexa de planos projetivos. / In this work, we consider the concept of a topological manifold. However, we focus on the connected 2-dimensional manifolds, the so-called surfaces. Our goal is the study of the topological classification of the compact surfaces. In this direction, we state and prove the classification Theorem of compact surfaces. That is, we show that every orientable compact surface is homeomorphic to the sphere or to a connected sum of torus, and every non-orientable compact surface is homeomorphic to a connected sum of projective planes.
5

Distribuições suportadas em um hiperplano e o espaço de Hardy hp(Rn)

Pes, Ronaldo Bressan 26 August 2015 (has links)
Submitted by Luciana Sebin (lusebin@ufscar.br) on 2016-09-19T18:14:38Z No. of bitstreams: 1 DissRBP.pdf: 974872 bytes, checksum: 7264be6bba5c7c937ff06e2fa5f3f507 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-20T18:15:41Z (GMT) No. of bitstreams: 1 DissRBP.pdf: 974872 bytes, checksum: 7264be6bba5c7c937ff06e2fa5f3f507 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-20T18:15:47Z (GMT) No. of bitstreams: 1 DissRBP.pdf: 974872 bytes, checksum: 7264be6bba5c7c937ff06e2fa5f3f507 (MD5) / Made available in DSpace on 2016-09-20T18:15:53Z (GMT). No. of bitstreams: 1 DissRBP.pdf: 974872 bytes, checksum: 7264be6bba5c7c937ff06e2fa5f3f507 (MD5) Previous issue date: 2015-08-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The main aim of this work is to study necessary and sufficient conditions for a distribution, whose compact support is contained in a hyperplane, to be in the local Hardy space hp(Rn). / O objetivo principal deste trabalho é estudar condições necessárias e suficientes para que uma distribuição, cujo suporte compacto está contido em um hiperplano, esteja no espaço de Hardy local hp(Rn).
6

Integración de diferentes fenómenos fotónicos en tecnología de disco compacto para el desarrollo de biosensores label-free

Sancho Fornés, Gabriel 02 September 2019 (has links)
Tesis por compendio / [ES] En esta tesis se ha abordado el desarrollo de biosensores ópticos label-free, basados en tecnología de disco compacto, permitiendo así abaratar y simplificar su fabricación. El trabajo llevado a cabo ha consistido en estudiar diferentes propiedades físico-químicas desarrolladas por diversos materiales. Ello ha permitido obtener sistemas compactos y accesibles, capaces de sensar con buenas prestaciones analíticas en diferentes escenarios. En el capítulo 1 se presenta un estudio de inhibición enzimática sobre discos Blu-ray como plataforma de ensayo para el cribado de fármacos. Para ello, se inmoviliza orientadamente una glicoenzima, de la familia de las peroxidasas sobre la superficie del disco, cuya actividad se relaciona con los compuestos a cribar. Después de ensayar cada compuesto, se determina el grado de inhibición enzimática mediante la adición de un sustrato. La cantidad de producto obtenido, inversamente proporcional al potencial inhibitorio del compuesto en estudio, es cuantificado con un lector de discos que registra las variaciones en la intensidad del haz laser reflejado debidas al producto enzimático. Ello permite realizar más de 1700 ensayos simultáneos en un único disco Blu-ray lo que muestra su potencial en análisis masivo de alto rendimiento. Además, se plantea una estrategia basada en hipersuperficies para el análisis de la elevada cantidad de datos que se generan en las etapas del proceso de descubrimiento de fármacos. En el capítulo 2 se aborda el estudio de una metodología para reducir el ruido generado en la lectura de resultados obtenidos con biosensores ópticos, mejorando así su sensibilidad. Para ello, se plantea la estructuración del ensayo en forma de franjas en lugar del tradicional microarray, generando una señal periódica sinusoidal al ser escaneadas. Al analizar dicha señal en dominio de frecuencias, ésta se concentra en un pico a la frecuencia del ensayo, mientras que la mayor parte del ruido aparece a frecuencias mucho más altas. Inicialmente se quería reducir al máximo el ruido, para diferenciar las interacciones moleculares en formato label free. Sin embargo, los ensayos realizados con discos DVD no generaron suficiente señal, teniendo que recurrir en esta ocasión al marcaje para la cuantificación de inmunoglobulinas G y de caseína. Pese a ello, la metodología desarrollada también se puede aplicar en biosensores tipo label-free, reduciendo el ruido y mejorando su sensibilidad. El capítulo 3 se centra en el desarrollo de sustratos interferométricos multicapa que varían la intensidad de la luz reflejada al realizar un ensayo analítico en su superficie. Los sustratos fueron fabricados utilizando los materiales que componen los DVD-RW, depositados en capas de espesor controlado con el fin de obtener la máxima respuesta. A su vez, se diseñaron de tal forma que uno de ellos disminuya la intensidad del haz reflejado como respuesta a las interacciones moleculares, mientras que el otro la aumenta. El trabajo incluye la utilización de principios y materiales de la tecnología de disco compacto para el desarrollo del sistema de detección. Para ello, se emplea el cabezal de un lector de DVD, ya que dispone de un láser y de todos los elementos ópticos necesarios para el escaneado vertical. Con este sistema se cuantifican con éxito y sin marcaje inmunoglobulinas G y sulfasalazina, una macromolécula y un fármaco de masa molecular reducida. El capítulo 4 consiste en la fabricación de un cristal fotónico utilizando la estructura de los discos compactos cubiertos con una película de óxido de titanio. Se han estudiado las propiedades físico-químicas de estos sustratos y se han caracterizado sus propiedades fotónicas. Todo ello está en concordancia con los resultados obtenido mediante simulaciones. Para interrogar los cristales fotónicos fueron necesarios una fuente de luz blanca y un espectrofotómetro, además de los elementos ópticos necesarios / [CA] En aquesta tesi s'ha abordat el desenvolupament de biosensors òptics label-free, basats en tecnologia de disc compacte, permetent així abaratir i simplificar la seua fabricació. El treball dut a terme ha consistit en estudiar diferents propietats fisicoquímiques desenvolupades per diversos materials. Això ha permès obtenir sistemes compactes i accessibles, capaços de sensar, amb bones prestacions analítiques, en diferents escenaris. En el capítol 1 es presenta un estudi d'inhibició enzimàtica sobre discos Blu-ray com a plataforma d'assaig per al cribratge de fàrmacs. Per a això, s'immobilitza de manera orientada una glicoenzima de la família de les peroxidases sobre la superfície del disc, i la seua activitat es relaciona amb els compostos a garbellar. Després d'assajar cada compost, es determina el grau d'inhibició enzimàtica mitjançant l'addició d'un substrat. La quantitat de producte obtingut, inversament proporcional al potencial inhibitori del compost en estudi, és quantificat amb un lector de discos que registra les variacions en la intensitat del làser reflectit degudes al producte enzimàtic. Això permet realitzar més de 1700 assajos simultanis en un únic disc Blu-ray el que mostra el seu potencial en anàlisi massiva d'alt rendiment. A més, es planteja una estratègia basada en hipersuperficies per a l'anàlisi de l'elevada quantitat de dades que es generen en les etapes del procés de descobriment de fàrmacs. En el capítol 2 s'aborda l'estudi d'una metodologia per reduir el soroll generat en la lectura de resultats obtinguts amb biosensors òptics, millorant així la seua sensibilitat. Per a això, es planteja l'estructuració de l'assaig en forma de franges en lloc del tradicional microarray, generant un senyal periòdic sinusoïdal en ser escanejades. En analitzar aquest senyal en domini de freqüències, aquesta es concentra en un pic a la freqüència de l'assaig, mentre que la major part del soroll apareix a freqüències molt més altes. Inicialment es volia reduir al màxim el soroll, per diferenciar les interaccions moleculars en format label-free. No obstant això, els assajos realitzats amb discos DVD no van generar prou senyal, havent de recórrer en aquesta ocasió al marcatge per a la quantificació d'immunoglobulines G i de caseïna. Malgrat això, la metodologia desenvolupada també es pot aplicar en biosensors tipus label-free, reduint el soroll i millorant la seua sensibilitat. El capítol 3 es centra en el desenvolupament de substrats interferometrics multicapa que varien la intensitat de la llum reflectida en realitzar un assaig analític en la seua superfície. Els substrats van ser fabricats utilitzant els materials que componen els DVD-RW, dipositats en capes de gruix controlat per tal d'obtenir la màxima resposta. Al seu torn, es van dissenyar de tal manera que un d'ells disminueixi la intensitat del feix reflectit com a resposta a les interaccions moleculars, mentre que l'altre l'augmenta. El treball inclou la utilització de principis i materials de la tecnologia de disc compacte per al desenvolupament del sistema de detecció. Per a això, es va utilitzar el capçal d'un lector de DVD, ja que disposa d'un làser i de tots els elements òptics necessaris per a l'escanejat vertical. Amb aquest sistema es quantifiquen amb èxit i sense marcatge immunoglobulines G i sulfasalazina, un macromolècula i un fàrmac de massa molecular reduïda. El capítol 4 consisteix en la fabricació d'un cristall fotònic utilitzant l'estructura dels discos compactes coberts amb una pel·lícula d'òxid de titani. S'han estudiat les propietats fisicoquímiques d'aquests substrats i s'han caracteritzat les propietats fotòniques. Tot això està en concordança amb els resultats obtingut mitjançant simulacions. Per interrogar els cristalls fotònics van ser necessaris una font de llum blanca i un espectrofotòmetre, a més dels elements òptics necessaris per guiar la llum. / [EN] In this thesis the development of label-free optical biosensors, based on compact disc technology, has been approached, thus making their manufacture cheaper and simpler. The work carried out has consisted of studying different physical-chemical properties manifested with several materials. This has allowed to obtain compact and accessible systems, capable of sensing with a great analytical performance in different scenarios. Chapter 1 presents an enzymatic inhibition study on Blu-ray discs as a test platform for drug screening. For this purpose, a glycoenzyme of the peroxidase family is immobilized on the surface of the disc whose activity is related to the compounds to be screened. After testing each compound, the degree of enzymatic inhibition is determined by adding the enzymatic substrate. The amount of product obtained is inversely proportional to the inhibitory potential of the compound, and is quantified with a disk reader that records the variations in the intensity of the reflected laser beam due to the enzymatic product. In addition, more than 1700 tests are performed on a single Blu-ray disc as proof of concept for application in high performance analysis and a hypersurface based strategy is proposed for the analysis of the large amount of data generated in the stages of the drug discovery process. Chapter 2 deals with the study of a methodology to reduce noise generated in the reading of results obtained with optical biosensors, hence improving their sensitivity. For this purpose, the structure of the test is proposed in the form of stripes instead of the traditional microarray, generating a sinusoidal periodic signal when they are scanned. When analysing this signal in frequency domain, it is concentrated in a peak at the frequency of the test, while most of the noise appears at much higher frequencies. Initially, the aim was to reduce noise as much as possible in order to differentiate molecular interactions in a label-free format. However, the tests carried out on a DVD did not generate enough signal, having to resort to labelling on this occasion for the quantification of immunoglobulins G and casein. Nevertheless, the methodology developed can be applied to label-free biosensors, reducing noise and improving sensitivity. Chapter 3 focuses on the development of multilayer interferometric substrates that vary the intensity of reflected light when performing an analytical test on their surface. The substrates were manufactured using the materials that make up the DVD-RW, deposited in layers of controlled thickness in order to obtain maximum response. At the same time, they were designed in such a way that one of them decreased the intensity of the reflected beam as a response to molecular interactions, while the other increased it. The work includes the use of principles and materials from compact disc technology for the development of the detection system. For this, the head of a DVD reader is used, as it has a laser and all the optical elements necessary for vertical scanning. With this system, immunoglobulins G and sulfasalazine, a macromolecule and a drug with reduced molecular mass are successfully quantified without labelling. Chapter 4 consists of the fabrication of a photonic crystal using the structure of the compact discs covered with a titanium oxide layer. The physical-chemical properties of these substrates have been studied and their photonic properties have been characterized. All this is in accordance with the results obtained through simulations. To interrogate the photonic crystals, a white light source and a spectrophotometer were needed, as well as the optical elements necessary to guide the light. / Sancho Fornés, G. (2019). Integración de diferentes fenómenos fotónicos en tecnología de disco compacto para el desarrollo de biosensores label-free [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/124819 / Compendio
7

Verificação da autenticidade de impressões digitais em tempo real utilizando-se o correlator óptico compacto / not available

Betiol, Anderson Duarte 26 February 2002 (has links)
Correlatores ópticos podem realizar o reconhecimento de padrões bidimensionais a uma velocidade maior que plataformas digitais com o mesmo tamanho, peso e consumo de potência. Utilizou-se neste projeto o correlator óptico compacto com um único modulador espacial de luz, uma TV a cristal líquido comercial, posicionado no plano de Fourier. Uma câmera CCD é utilizada na saída do correlator óptico para capturar as imagens de correlação. Na entrada do correlator, a imagem da impressão digital é capturada por um prisma via eliminação da reflexão total, durante o contato da impressão digital com a superfície do prisma. Para o processo de filtragem, foi utilizado o filtro de correlação ótima. / Optical correlators can realize bidimensional pattern recognition faster than digital devices that have the same size, weight and power consumption. In this work, the compact optical correlator is implemented with only one spatial light modulator, a commercial liquid crystal television (LCTV) located at the Fourier plane. A CCD camera is used at the correlator exit to read the correlation images. The fingerprint image is read in the correlator input using a prism illuminated with a monochromatic coherent beam. The total reflection elimination in the prism surface during the fingerprint contact permits the reading of the fingerprint image. The optimal correlation filter is used in the Fourier plane to implement the filtering process.
8

Search for new resonances in the merged jet plus dilepton final state in CMS /

Ruiz Vargas, José Cupertino. January 2017 (has links)
Orientador: Sérgio Ferraz Novaes / Coorientador: Thiago R. F. P. Tomei / Banca: Alexandre Alves / Banca: Antonio Vilela Pereira / Banca: Gilvan Augusto Alves / Banca: Murilo Santana Rangel / Resumo: Na Organização Europeia para a Pesquisa Nuclear (CERN), o Large Hadron Collider (LHC) colide grupos de prótons 40 milhões de vezes por segundo a uma energia de 13 TeV. Operando junto ao LHC, o Compact Muon Solenoid (CMS) é um detector projetado para identificar uma ampla gama de partículas produzidas nessas colisões. As partículas produzidas em cada colisão são observadas nos subdetectores na busca de pistas sobre a Natureza no seu nível mais fundamental. Apesar do modelo padrão das partículas elementares ter sido testado em uma variedade de experimentos de altas energias, um dos principais objetivos do LHC é a busca de uma nova física além daquela prevista pela teoria existente. Nesse trabalho analisamos os dados de colisões próton-próton produzidos pelo LHC operando com energia de centro de massa de 13 TeV e coletados pelo CMS em 2015. O presente estudo envolve a busca de uma ressonância X não observada previamente, decaindo em um par de bósons vetoriais. Os resultados são interpretados no contexto do modelo de dimensões extras deformadas de Randall-Sundrum, distinguindo as hipóteses de fundo (modelo padrão) e fundo mais sinal (modelo padrão + graviton). Nenhuma evidência da existência de uma partícula com as características do graviton de Randall-Sundrum foi encontrada. Limites superiores com nível de confiança de 95% são estabelecidos para a seção de choque de produção da ressonância X decaindo em um par de bosons Z, para valores de massa MX no intervalo 800 - 3000 GeV. A exclusão esperada (observada) no valor de massa MX = 800 GeV é 154 fb (93 fb); para o valor de massa MX = 3000 GeV o valor de exclusão esperado (observado) diminui para 19 fb (15 fb). Um excesso com significância global igual a 2s é observado no ponto de massa MX = 1000 GeV. / Abstract: At the European Organization for Nuclear Research (CERN), the Large Hadron Collider (LHC) smashes groups of protons 40 million times per second at an energy of 13 TeV. Operating at the LHC, the Compact Muon Solenoid (CMS) is a multipurpose detector conceived to identify a large variety of particles produced in such collisions. The produced particles are observed at the sub-detectors in search of clues about Nature at the most fundamental level. In spite of the impressive agreement of the standard model with all the experimental results obtained so far, one of the main aims of the LHC is the search of new physics beyond the one foreseen by this theoretical model. In this work, we analyze proton-proton collisions delivered by the LHC operating at centre-of-mass energy of 13 TeV and collected by CMS during 2015. The channel under study involves the search for an unknown resonance X decaying into a pair of vector bosons. The results are interpreted in the context of the Randall-Sundrum warped extra-dimensional model, distinguishing between the hypotheses of background only (standard model) and background plus signal (standard model + graviton). No evidence of the existence of a graviton-like particle was found. Upper limits at 95% confidence level are set for the production cross section of a resonance X decaying to a pair of Z bosons, for values of mass MX in the range between 800 - 3000 GeV. The limit expected (observed) at MX = 800 GeV is 154 fb (93 fb); for the mass point MX = 3000 GeV the limit expected (observed) decreases to 19 fb (15 fb). A localised excess with global significance equal to 2s is observed in the mass point MX = 1000 GeV. / Doutor
9

Avalia??o de dois modelos de maternidade para su?nos / Assessment of two models of maternity systems for pigs

Sabino, Luana Ara?jo January 2010 (has links)
Submitted by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-11-20T17:04:17Z No. of bitstreams: 2 luana_araujo_sabino.pdf: 4890945 bytes, checksum: afddfa662d3a96b16a48e2787b10c2b4 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-11-20T17:05:00Z (GMT) No. of bitstreams: 2 luana_araujo_sabino.pdf: 4890945 bytes, checksum: afddfa662d3a96b16a48e2787b10c2b4 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-11-20T17:05:00Z (GMT). No. of bitstreams: 2 luana_araujo_sabino.pdf: 4890945 bytes, checksum: afddfa662d3a96b16a48e2787b10c2b4 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / Um dos maiores problemas relacionados ao conforto t?rmico e bem-estar animal na suinocultura est? na maternidade, na qual se t?m dois ambientes distintos a serem avaliados, com exig?ncias bem diferenciadas. Objetivou-se com esse estudo ampliar o conhecimento relativo ao efeito dos modelos de maternidade e de aquecimento do abrigo escamoteador para leit?es, utilizando como ferramenta de avalia??o a an?lise de imagem para o entendimento do comportamento animal, avaliar alguns dos ?ndices zoot?cnicos tanto dos leit?es quanto das f?meas que podem ser influenciados pelo ambiente e possibilitar an?lise econ?mica dos modelos. Foram avaliados dois tipos de celas parideiras e dois tipos de escamoteador. O modelo 1 (MOD 1) formado por 8 celas parideiras com piso semi-ripado, e escamoteador de alvenaria, com aquecimento por meio de resist?ncia el?trica embutida no piso e ilumina??o com l?mpada fluorescente de 7 W. O modelo 2 (MOD 2) composto por 8 celas parideiras totalmente ripado de ferro, com o escamoteador de madeira, com o aquecimento por meio de l?mpada incandescente de 60 W. Os dados foram coletados do nascimento at? o 21? dias. O MOD 1 obteve os melhores valores de desempenho para os leit?es. Escamoteadores do MOD 1 obtiveram maiores percentuais de temperaturas dentro do conforto t?rmico em rela??o ao MOD 2, apesar dos elevados percentuais de temperatura abaixo do conforto. A temperatura do piso do MOD 1 obteve maiores percentuais de valores dentro do conforto t?rmico em todas as semanas do per?odos experimental. A temperatura do piso das celas no MOD 1 foi mais elevadas em rela??o ao MOD 2. A higiene das celas n?o foi afetada diretamente pela estrutura da cela e sim por altera??es no manejo, como arra?oamento em hor?rio diferente do habitual. A mortalidade, onfalite, artrite e les?es nos joelhos dos leit?es n?o apresentaram diferen?a significativa ente os modelos (p< 0,05). O modelo 1 apresentou um lucro superior ao modelo 2, de aproximadamente R$ 1,37 por leitegada, sendo necess?rio avaliar o gasto com m?o de obra para inferir qual o modelo ? mais rent?vel para o produtor. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Zootecnia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2010. / ABSTRACT One of the main problems relating to thermal comfort and animal welfare in pig farming is in maternity, which have two different environments with very different requirements to be evaluated. This study aimed to expand the knowledge on the effect of the systems to maternity and heating of creep for piglets using the image analysis as evaluation tool to understand animal behavior, to evaluate some of the indexes of both piglets and the females considering that it can be influenced by environment and allow an economic analysis of this systems. There were evaluated two types of dam cells and two types of creep. The model 1 (MOD 1) was formed by 8 dam cells with semi-slatted floor and creep of masonry, with electrical resistance built into the floor and illumination with fluorescent lamp of 7 W. The model 2 (MOD 2) consisted of eight dam cells with totally ripped iron, with the creep of wood for heating by incandescent lamp of 60W. Data were collected from birth until weaning at 21 days. The MOD 1 showed the best performance values for piglets. The temperature of the creep of MOD 1 showed the highest percentage of temperatures within the thermal comfort in relation to MOD 2, despite the high percentage of temperature below comfort. The temperature of the floor of MOD 1 showed the highest percentage of values within the thermal comfort in every week of the experimental period. The temperature of the surface of the cells in MOD 1 were higher compared to the MOD 2, but not enough to cause thermal discomfort for the sows. The hygiene of the cells was not affected directly by the structure of the cell but rather by changes in handling practices such as feeding on different time than usual. Mortality, omphalitis, arthritis and knee injuries of the piglets showed no significant differences between the systems (p<0.05). The use of the system with creep with heated floors (MOD 1) showed a profit above the heating system with a light bulb (MOD 2) of approximately R$ 1,37 for litter, being necessary the evaluation of the expends to infer about the most financially profitable system for the producer.
10

Estudo de Monte Carlo da produção de nova ressonância neutra decaindo em dois bósons vetoriais no experimento CMS

Ruiz Vargas, José Cupertino [UNESP] 15 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-15Bitstream added on 2014-06-13T19:12:26Z : No. of bitstreams: 1 ruizvargas_jc_me_ift.pdf: 1319759 bytes, checksum: bc922e0bd52ff609b646c63b4019bf05 (MD5) / Estudamos neste trabalho a produção de um novo bóson vetorial neutro pelo detector Compact Muon Solenoid (CMS) do Large Hadron Collider (LHC). Adotamos as condições de operação do LHC em 2012, i.e. energia do centro de massa de 8 TeV e luminosidade integrada de 20 'fb POT.−1'. Nós realizamos um estudo de viabilidade da busca de física além do modelo padrão através da produção e decaimento de uma ressonância exótica em um par de bósons vetoriais 'W POT.+W POT.−'. O fundo do Modelo Padrão foi estimado por amostras de Monte Carlo geradas centralmente pela colaboração CMS, enquanto as amostras do sinal foram simuladas localmente por nós no SPRACE. A massa transversal invariante foi reconstruída usando léptons de cargas opostas mais a energia transversal faltante. Uma análise da significância, considerando sinais com massas de 0.5, 1, 1.5, e 2 TeV, foi implementada para melhorar a eficiência da seleção de eventos. Finalmente, para avaliar a sensibilidade da análise, foram estabelecidos limites esperados com 95% CL para a seção de choque multiplicada pela razão de ramificação σ(pp → Z')×BR(Z' → WW → e+µ+ET/ ) / In this work, we study the production of a new neutral vector boson at the Compact Muon Solenoid(CMS)detectorfromthe Large Hadron Collider(LHC).We adopt the operation parameters of the LHC during the 2012 run, i.e. center-of-mass energy of 8 TeV and integrated luminosity of 20 'fb POT. −1'. We conducted a feasibility study of the search for physics beyond the standard model through the production and decay of an exotic resonance in a pair of vector bosons 'W POT.+W POT.−'. The Standard Model background was estimated by Monte Carlo samples centrally generated by CMS, while the signal samples were simulated locally by us at SPRACE. The invariant transverse mass was reconstructed using the oppositely charged leptons and the missing transverse energy. An analysis of the significance of the signal, considering resonances with mass of 0.5, 1, 1.5, and 2TeV, was implemented to improve the efficiency of the event selection. Finally, to assess the sensitivity of the analysis, we calculated the 95% CL limits for the cross section times the branching ratio, σ(pp → Z')×BR(Z' → WW → e+µ+ET/ )

Page generated in 0.047 seconds