• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 36
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 365
  • 365
  • 365
  • 365
  • 282
  • 279
  • 247
  • 246
  • 56
  • 54
  • 53
  • 49
  • 49
  • 46
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Multi-modal registration of maxillodental CBCT and photogrammetry data over time

Bolandzadeh-Fasaie, Niousha Unknown Date
No description available.
12

Évaluation des effets dento-alvéolaires et squelettiques de l'expansion palatine rapide assistée chirurgicalement à l'aide de tomodensitométrie à faisceau conique

Quintin, Olivier January 2009 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
13

Three dimensional evaluation of the TMJ condyle position in different types of skeletal patterns

Guedes, Ines H. 06 March 2014 (has links)
Objective: To evaluate three-dimensional position of the TMJ condyle within the glenoid fossa in different types of skeletal patterns. Materials and methods: Ninety CBCT images were consecutively selected and divided into skeletal class I, class II and class III. The images were analyzed locating landmarks in the different areas of the condyle and glenoid fossa. All landmarks presented acceptable reliability. The mean results were compared using ANOVA and Bonferroni post-hoc test (p < 0.05). Results: There was a tendency for the anterior joint space to be smaller than the posterior joint space. Statistical analysis, however, evidenced no significant differences between the anterior, superior and posterior joint spaces and the different skeletal patterns or between sides. Conclusion: There was non-concentricity of the condyle for all the groups studied, and no particular direction was statistically significantly favored. It is unclear whether the differences found would be clinically significant, considering anatomical individual variations.
14

Comparison of clinical, periapical radiograph and cone beam volume tomography measurement techniques for assessing bone level changes following regenerative periodontal therapy a thesis /

Grimard, Brently Allan. January 2008 (has links)
Thesis (M.S.) --University of Texas Graduate School of Biomedical Sciences at San Antonio, 2008. / Vita. Includes bibliographical references.
15

A study using 3D cone beam computed tomography to evaluate masseter muscle morphology in observed skeletal malocclusions

Becht, Michael P. January 2009 (has links)
Thesis (M.S.)--West Virginia University, 2009. / Title from document title page. Document formatted into pages; contains viii, 88 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 62-66).
16

Scatter correction, intermediate view estimation and dose characterization in megavoltage cone-beam CT imaging a dissertation /

Sramek, Benjamin Koerner. January 2008 (has links)
Dissertation (Ph.D.) --University of Texas Graduate School of Biomedical Sciences at San Antonio, 2008. / Vita. Includes bibliographical references.
17

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
18

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
19

Estudo comparativo de cefalogramas realizados sobre reconstruções de tomografia cone beam total e unilaterais da face e telerradiografias convencionais

Liedke, Gabriela Salatino January 2009 (has links)
A possibilidade de exploração das imagens oferecida pela tomografia computadorizada cone beam (TCCB) permite investigações mais detalhadas do paciente. Este estudo, empregando alguns destes recursos, se propôs a comparar medidas cefalométricas realizadas sobre telerradiografias convencionais e reconstruções de perfil total e unilaterais obtidas da TCCB. Análises cefalométricas de 30 pacientes foram realizadas por um examinador calibrado sobre as reconstruções da TCCB e as telerradiografias convencionais. A reprodutibilidade dos fatores cefalométricos foi investigada por meio do coeficiente de correlação intraclasse em cada imagem. O método de Bland-Altman foi utilizado para averiguar a performance diagnóstica de cada imagem em relação às medidas de cada fator cefalométrico. O coeficiente de correlação intraclasse evidenciou semelhança de reprodutibilidade entre os exames. Quando os valores dos fatores cefalométricos foram comparados, observou-se forte concordância diagnóstica entre as mensurações realizadas sobre telerradiografias convencionais e imagens reconstruídas por TCCB. Conclui-se que, em pacientes sem assimetrias faciais importantes, a telerradiografia convencional e as reconstruções total e unilaterais a partir da TCCB oferecem desempenho de reprodutibilidade e resultado de análise cefalométrica semelhantes. / The possibility to explore images afforded by the cone beam computer tomography (CBCT) technique allows investigating patients in more detail. The present study uses some of these resources to compare cephalometric measurements obtained from conventional cephalograms and total and half-skull synthesized cone beam computed tomography (CBCT) cephalograms. Cephalometric analyses of 30 clinically symmetric patients; were conducted by a calibrated examiner on conventional and CBCTsynthesized cephalograms. Reproducibility was investigated using the intraclass correlation coefficient. The Bland-Altman analysis was used to assess the agreement of the measurements from each factor obtained by conventional, total, right and left CBCT-synthesized cephalograms. The intraclass correlation coefficient revealed similar levels of reproducibility. When the measurements obtained from conventional and CBCT-synthesized cephalograms were compared, the Bland-Altman analysis showed a strong agreement between them. Half-skull CBCT-synthesized cephalograms offer the same diagnostic performance and equivalent reproducibility in terms of cephalometric analysis as observed in conventional and total CBCT-synthesized cephalograms.
20

Validity of water and acrylic as soft tissue simulation materials in an in vitro study using cone beam computed tomography / Validade da água e acrílico como materiais simuladores de tecidos moles em estudo in vitro realizado com tomografia computadorizada de feixe cônico

Visconti, Maria Augusta Portella Guedes, 1985- 24 August 2018 (has links)
Orientador: Francisco Haiter Neto / Texto em português e inglês / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T17:16:38Z (GMT). No. of bitstreams: 1 Visconti_MariaAugustaPortellaGuedes_D.pdf: 2357684 bytes, checksum: ed042e1f5da51d27eae5691a052e4cc3 (MD5) Previous issue date: 2014 / Resumo: O presente estudo propôs-se validar os materiais água e acrílico como simuladores de tecidos moles em um estudo in vitro realizado com tomografia computadorizada de feixe cônico (TCFC). Para isso foram utilizadas três cabeças humanas, com tecidos moles intactos, para determinação do padrão-ouro. Essas cabeças foram submetidas a exames de TCFC e posteriormente descarnadas e tomografadas novamente, agora com diferentes tipos de simuladores de tecido mole, seguindo o mesmo protocolo de aquisição. Para simulação dos tecidos moles foram confeccionadas três caixas de acrílico com diferentes dimensões e espessuras. Estas caixas foram utilizadas isoladamente, conjugadas entre si e em combinação com a água, totalizando dez diferentes tipos de simuladores. Um único avaliador experiente realizou as mensurações em quatro regiões de interesse para maxila e mandíbula, incluindo dentes e ossos alveolares. As regiões de interesse consistiram em áreas quadrangulares, nas quais foram determinados todos os valores de cinzas expressos em pixels. Os resultados mostraram que tanto a região avaliada quanto os tipos de simuladores testados interferiram diretamente nos valores de pixels obtidos. As caixas de acrílico de 0,5 e 1,5 cm de espessura foram os simuladores que mais se assemelharam ao padrão-ouro, não apresentando diferença significativa. No entanto, essa similaridade apenas foi observada para a maxila, limitada às regiões dos dentes e ossos alveolares anteriores. A simulação dos tecidos moles realizada apenas com o acrílico foi a que mais se aproximou dos tecidos moles humanos nas imagens de TCFC, apenas para maxila / Abstract: The aim of this study was to validate the materials water and acrylic as soft tissue simulators in an in vitro study conducted with cone beam computed tomography (CBCT). For this we used three human heads, with soft tissues intact, to determine the "gold standard". These heads were submitted to CBCT exams, and subsequently stripped and scanned again, this time with different types of soft tissue simulators, following the same acquisition protocol. For soft tissue simulation, three acrylic boxes of differing dimensions and thicknesses were prepared. These boxes were used separately, combined together, and in combination with water, totaling ten different types of simulators. A single experienced evaluator did measurements in four regions of interest for the maxilla and mandible, including teeth and alveolar bone. The regions of interest consisted of quadrangular areas, in which all gray values were determined, expressed in pixels. The results sowed both the region evaluated as well as the types of simulators tested directly affected the pixel values obtained. The acrylic boxes with 0.5 and 1.5 cm thickness were the simulators that more closely resembled the gold standard, presenting no significant difference. However, this similarity was observed only for the maxilla, limited to the anterior tooth and alveolar bone regions. The simulation of soft tissues done solely with acrylic was the one closest to human soft tissues in the CBCT images, only for maxilla / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica

Page generated in 0.0751 seconds