• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação das condições de desempenho acústico, lumínico e térmico em edificações de porte monumental : um estudo de caso da Biblioteca Central e do Restaurante Universitário da Universidade de Brasília

Oliveira, Ana Luiza Alves de 16 December 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Falculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2017-01-26T12:34:51Z No. of bitstreams: 1 2016_AnaLuizaAlvesdeOliveira.pdf: 4283704 bytes, checksum: 708d31f7a13fdd492fe6e502281fe331 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-03-24T18:39:05Z (GMT) No. of bitstreams: 1 2016_AnaLuizaAlvesdeOliveira.pdf: 4283704 bytes, checksum: 708d31f7a13fdd492fe6e502281fe331 (MD5) / Made available in DSpace on 2017-03-24T18:39:05Z (GMT). No. of bitstreams: 1 2016_AnaLuizaAlvesdeOliveira.pdf: 4283704 bytes, checksum: 708d31f7a13fdd492fe6e502281fe331 (MD5) / O conforto ambiental é composto pelo conforto visual, acústico, lumínico e térmico. Estudos revelam que para que ocorra uma boa qualidade e produtividade no trabalho, o conforto ambiental é essencial. Diante disso, o presente trabalho tem como objetivo verificar as condições de conforto acústico, lumínico e térmico em edificações de porte monumental de arquitetura modernista, analisando se elas atendem aos requisitos mínimos exigidos pela norma de desempenho e de outras normas pertinentes e se as premissas de projeto foram cumpridas. Como estudo de caso, avaliou-se o restaurante universitário e a biblioteca central da Universidade de Brasília. Para isso, foi feita uma entrevista com o projetista dessas construções, o Dr. Arquiteto José Galbinski, na qual foram identificadas as premissas de projeto. Através da aplicação de questionários as percepções dos usuários das edificações foram detectadas. E, por fim, medições in loco avaliando o nível de nível de isolamento sonoro de impacto, o nível de pressão sonora e de iluminância artificial foram realizadas. Com o estudo, concluiu-se que, na biblioteca central, quanto ao isolamento sonoro de impacto, seu desempenho foi superior ao exigido pela ABNT NBR 15.575 e que as premissas de projeto no que tange ao conforto acústico foram atendidas. Já no RU essas premissas não foram alcançadas, uma vez que o nível de ruído medido no local era maior que o recomendado pelas normas brasileiras e os seus usuários consideraram o local barulhento. Quando ao conforto lumínico, tanto na biblioteca central quanto no restaurante universitário o nível de luminosidade artificial foi superior ao mínimo exigido pela norma de desempenho, porém inferior ao recomendado pela ISO 8995. No que concerne ao conforto térmico, as duas edificações foram consideradas quentes pelos usuários e as premissas de projeto do arquiteto foram aprovadas com ressalvas. / The environmental comfort is consisted of visual, acoustic, lighting and thermal comfort. Studies show that for good quality and productivity at work, the environmental comfort is essential. Therefore, the objective of this study is to verify the conditions of acoustic, luminous and thermal comfort in monumental buildings of modernist architecture, analyzing whether they achieved the minimum requirements demanded by the ABNT BR 15.575 and other pertinent codes, and if the project assumptions were reached. As case study, the university restaurant and the central library of the University of Brasília were evaluated. For this, an interview was made with the designer of these constructions, Dr. architect José Galbinski, in which the project premises were identified. Through the application of questionnaires, the perceptions of the users of the buildings were detected. And, finally, on-site measurements were performed.With the study, it was concluded that in the central library, regarding impact sound insulation, its performance was superior to that required by ABNT NBR 15.575 and that the design premises in relation to acoustic comfort were achieved. In the university restaurant, these premises were not reached, since the noise level measured in the place was higher than the one recommended by the Brazilian norms and its users considered the place noisy. About lighting comfort, both, the central library and the university restaurant, the level of luminosity was higher than the minimum required by the standard of performance, but lower than the one recommended by ISO 8995.
2

Estudo dos sistemas de iluminação artificial em edifícios corporativos: o escritório sede da PHILIPS em BARUERI - SP

Fernandes, Patricia Silva 17 August 2016 (has links)
Submitted by Rosa Assis (rosa_assis@yahoo.com.br) on 2016-09-30T13:33:05Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Patricia Silva Fernandes.pdf: 10565507 bytes, checksum: cee5f04c63550511b77da74c14033c69 (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2016-10-01T15:43:28Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Patricia Silva Fernandes.pdf: 10565507 bytes, checksum: cee5f04c63550511b77da74c14033c69 (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2016-10-04T14:14:33Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Patricia Silva Fernandes.pdf: 10565507 bytes, checksum: cee5f04c63550511b77da74c14033c69 (MD5) / Made available in DSpace on 2016-10-04T14:39:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Patricia Silva Fernandes.pdf: 10565507 bytes, checksum: cee5f04c63550511b77da74c14033c69 (MD5) Previous issue date: 2016-08-17 / Artificial lighting is considered one of the biggest energy costs in commercial buildings after the air conditioning systems. The design of efficient lighting system contributes to energy sustainability of buildings throughout the building life cycle. Another important aspect of the project is the importance of quality lighting in the health and safety of workers, directly affecting its production. This research aims to analyze what characteristics lead to the quality of artificial lighting design and energy efficiency. The method applied is the embedded case study, having as object of study the Philips head office in Barueri. The form of analysis is to support Brazilian rules and American on the subject, ISO / CIE. 8995-1 (2013) and the Guide ANSI / IES - RP-1-12 (2012) and the certification of LEED and RTQ-C Procel. The analysis carried out at the office Philips demonstrates a balance from the design of interior design, with the colors of the walls in each room designed for their use, but also for better lighting and user productivity. / A iluminação artificial é considerada como um dos maiores gastos energéticos nos edifícios comerciais, depois dos sistemas de ar condicionado. A concepção do sistema de iluminação eficiente contribui com a sustentabilidade energética dos edifícios, ao longo do ciclo de vida da edificação. Outro aspecto relevante no projeto é a importância da qualidade da iluminação na saúde e na segurança dos trabalhadores, afetando diretamente a sua produção. Esta pesquisa tem como objetivo analisar quais as características que levam à máxima qualidade no projeto de iluminação artificial. O método aplicado será o estudo de caso incorporado, tendo como objeto de estudo o escritório sede da Philips, em Barueri. A forma de análise tem como apoio as normas Brasileiras e Americana sobre o assunto, NBR ISO/CIE. 8995-1(2013) e o Guia ANSI/IES - RP-1-12(2012) e as certificações LEED e RTQ-C PROCEL. A análise realizada no escritório da Philips demonstra um equilíbrio desde a concepção do projeto de interiores, com as cores das paredes projetadas para o uso específico de cada ambiente, como também para uma melhor iluminação e produtividade dos usuários.
3

O uso do pet em telhas translúcidas visando o conforto natural lumínico e térmico / The use of pet in translucent roofing in order to a luminous, thermal and natural comfort

CAVALCANTE, Christiane Rosa de Paiva 23 September 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:48Z (GMT). No. of bitstreams: 1 Dissertacao Christiane R de P Cavalcante.pdf: 2530151 bytes, checksum: c8418cc369a22584f8884d3a586e48ae (MD5) Previous issue date: 2011-09-23 / The PET, tereftalato of ethylene, is the most known and appropriated material in the manufacture of several packings of nourishing products, specially the bottles of beverages. The correct management of the urban solid residues to the transformation into those which return to the use and the environment education are essential tasks to guarantee the exploitation of the complete useful life of this material and to prevent it on environmental focus. From the industrial point of view, the PET recycling in Brazil is still a recently activity. All around the country there are recycling industries, but they were created specially for environmental reasons. Although they became an important source of jobs and income. That s why, nowadays, recycling industries are considered an important social order factor. In Brazil, there are industries which transform the PET into roofing tiles for covering for drawing or injection. In this work, the main analyzed topic was the properties of the transparent roofing tiles of PET and other materials, the polycarbonate and the available fiberglass in the civil construction market through the main properties and relative parameters to the natural illumination, including its optic properties and the objective of the luminous and thermal comfort. Using the results of the spectrophotometer device, it was made a comparison among the studied materials in order to help the best choice of luminous and thermal comfort materials. PET, compared to the other studied materials, is not the best choice, even concerned to the price. However, for environmental solutions, the best way to use this solid waste recycling is the utilization of the PET as transparent roofing tiles, specially considering the amount of material all around rivers, scoots, attires, and so on. / O PET, tereftalato de etileno, é o material mais conhecido e apropriado na fabricação de várias embalagens de produtos alimentícios, entre as quais se destacam as garrafas de refrigerante. A correta gestão dos resíduos sólidos urbanos, com a transformação desses resíduos para o retorno ao uso, e a educação ambiental são tarefas essenciais para garantir o aproveitamento da totalidade da vida útil daquele material e evitar que seja ele o foco de contaminação ambiental. Do ponto de vista industrial, a reciclagem de PET no Brasil ainda é uma atividade recente. Há indústrias recicladoras em todo o território nacional criadas primordialmente para guarnecer uma questão ambiental, mas que culminou em uma questão de ordem social com geração de empregos e renda. No mercado existem no Brasil empresas que transformam o PET em telhas de cobertura por extrusão ou injeção. Neste trabalho foram analisadas as propriedades das telhas transparentes de PET e de outros materiais, o policarbonato e a fibra de vidro disponíveis no mercado da construção civil através das principais propriedades e parâmetros relativos à iluminação natural, incluindo suas propriedades óticas e com o objetivo do conforto lumínico e o térmico. Por meio dos resultados obtidos pelo uso do aparelho de espectrofotômetro, elaborou-se uma comparação entre os materiais estudados a fim de auxiliar na sua escolha, visando um melhor conforto lumínico e térmico. O PET não obteve o comportamento ansiado em comparação com os demais materiais estudados, também em relação ao custo pode-se observar que é mais onerosa a instalação do telhado de PET. Mas já em relação ao quesito de reaproveitamento de resíduos sólidos urbanos descartados no meio ambiente, o PET possui melhor desempenho uma vez que seu material se encontra em abundância e pode ser transformado e reaproveitado, amenizando o impacto ambiental.

Page generated in 0.0622 seconds