• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 1
  • 1
  • Tagged with
  • 12
  • 12
  • 12
  • 12
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The use of valved conduits for right ventricular outflow reconstruction in children: a systematicreview and meta-analysis

Loi, Chan-pong., 雷振邦. January 2011 (has links)
published_or_final_version / Paediatrics / Master / Master of Medical Sciences
2

Aortic root dilation and stiffness in children after repair of Tetralogy of Fallot

Chong, Wan-yip. January 2004 (has links)
Thesis (M. Med. Sc.)--University of Hong Kong, 2004. / Also available in print.
3

Growth impairment in patients with congenital heart disease /

Jacobs, Esther Gertruda Josephus. January 1999 (has links)
Thesis (M. Phil.)--University of Hong Kong, 1999. / Includes bibliographical references (leaves 111-127).
4

Body composition in children and adolescents with congenital heart disease and residual pulmonary regurgitation

Spencer, Mark Kendall, 1958- January 1988 (has links)
The body composition of children and adolescents with congenital heart disease and residual pulmonary regurgitation (PR) was compared to that of healthy age- and sex-matched controls. Testing included height, weight, skinfolds, skeletal widths, circumferences, bio-electrical impedance (for estimation of total body water from resistance index), hydrostatic weighing, bone mineral content from single photon absorptiometry, and an assessment of maturational status. Activity levels were assessed by questionnaires and an accelerometer. The two groups were found to be different in height, skeletal widths, bone mineral content, bone mineral index and total body water determined by bio-electrical impedance. After adjusting the data for height differences, the groups were different for skeletal widths and bone mineral index. The PR and control subjects had similar skinfolds and circumferences, as well as percent fat determined by body density, body water and bone mineral content.
5

Recovery kinetics in Chinese children with simple repaired congenital heart disease

洪克賢, Hung, Newman. January 2001 (has links)
published_or_final_version / Sports Science / Master / Master of Science in Sports Science
6

Recovery kinetics in Chinese children with simple repaired congenital heart disease /

Hung, Newman. January 2001 (has links)
Thesis (M. Sc.)--University of Hong Kong, 2001. / Includes bibliographical references (leaves 68-75).
7

Aortic root dilation and stiffness in children after repair of Tetralogy of Fallot

Chong, Wan-yip., 莊雲葉. January 2004 (has links)
published_or_final_version / Medical Sciences / Master / Master of Medical Sciences
8

Utility of the routine chest radiograph following removal of a chest tube in pediatric postoperative cardiac patients

Gerrein, Betsy T. January 1900 (has links)
Thesis (M.A.)--Northern Kentucky University, 2007. / Made available through ProQuest. Publication number: AAT 1447123. ProQuest document ID: 1414126941. Includes bibliographical references (p. 30-31)
9

Growth impairment in patients with congenital heart disease

Jacobs, Esther Gertruda Josephus. January 1999 (has links)
published_or_final_version / Paediatrics / Master / Master of Philosophy
10

Computational Design of Structures for Enhanced Failure Resistance

Russ, Jonathan Brent January 2021 (has links)
The field of structural design optimization is one with great breadth and depth in many engineering applications. From the perspective of a designer, three distinct numerical methodologies may be employed. These include size, shape, and topology optimization, in which the ordering typically (but not always) corresponds to the order of increasing complexity and computational expense. This, of course, depends on the particular problem of interest and the selected numerical methods. The primary focus of this research employs density-based topology optimization with the goal of improving structural resistance to failure. Beginning with brittle fracture, two topology optimization based formulations are proposed in which low weight designs are achieved with substantially increased fracture resistance. In contrast to the majority of the current relevant literature which favors stress constraints with linear elastic physics, we explicitly simulate brittle fracture using the phase field method during the topology optimization procedure. In the second formulation, a direct comparison is made against results obtained using conventional stress-constrained topology optimization and the improved performance is numerically demonstrated. Multiple enhancements are proposed including a numerical efficiency gain based on the Schur-complement during the analytical sensitivity analysis and a new function which provides additional path information to the optimizer, making the gradient-based optimization problem more tractable in the presence of brittle fracture physics. Subsequently, design for ductile failure and buckling resistance is addressed and a numerically efficient topology optimization formulation is proposed which may provide significant design improvements when ductile materials are used and extreme loading situations are anticipated. The proposed scheme is examined regarding its impact on both the peak load carrying capacity of the structure and the amount of external work required to achieve this peak load, past which the structure may no longer be able to support any increase in the external force. The optimized structures are also subjected to a post-optimization verification step in which a large deformation phase field fracture model is used to numerically compare the performance of each design. Significant gains in structural strength and toughness are demonstrated using the proposed framework. Additionally, the failure behavior of 3D-printed polymer composites is investigated, both numerically and experimentally. A large deformation phase field fracture model is derived under the assumption of plane-stress for numerical efficiency. Experimental results are compared to numerical simulations for a composite system consisting of three stiff circular inclusions embedded into a soft matrix. In particular, we examine how geometric parameters, such as the distances between inclusions and the length of initial notches affect the failure pattern in the soft composites. It is shown that the mechanical performance of the system (e.g. strength and toughness) can be tuned through selection of the inclusion positions which offers useful insight for material design. Finally, a size optimization technique for a cardiovascular stent is proposed with application to a balloon expandable prosthetic heart valve intended for the pediatric population born with Congenital Heart Disease (CHD). Multiple open heart surgical procedures are typically required in order to replace the original diseased valve and subsequent prosthetic valves with those of larger diameter as the patient grows. Most expandable prosthetic heart valves currently in development to resolve this issue do not incorporate a corresponding expandable conduit that is typically required in a neonate without a sufficiently long Right Ventricular Outflow Tract (RVOT). Within the context of a particular design, a numerical methodology is proposed for designing a metallic stent incorporated into the conduit between layers of polymeric glue. A multiobjective optimization problem is solved, not only to resist the retractive forces of the glue layers, but also to ensure the durability of the stent both during expansion and while subject to the anticipated high cycle fatigue loading. It is demonstrated that the surrogate-based optimization strategy is effective for understanding the trade-offs between each performance metric and ultimately efficiently arriving at a single optimized design candidate. Finally, it is shown that the desired expandability of the device from 12mm to 16mm inner diameter is achievable, effectively eliminating at least one open heart surgical procedure for certain children born with CHD.

Page generated in 0.1412 seconds