• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

AvaliaÃÃo do descenso perineal utilizando o ultrassom anorretal tridimensional dinÃmico comparado com a proctografia evacuatÃria dinÃmica / Analysis of a novel 3-d dynamic anorectal ultrasonography technique for the assessment of perineal descent, compared with dynamic evacuation proctography

Gabriel Santos Soares 19 July 2010 (has links)
CoordenaÃÃo de AperfeiÃoamento de NÃvel Superior / O objetivo à verificar a aplicabilidade de uma nova tÃcnica, com quantificaÃÃo de valores numÃricos para o diagnÃstico do descenso perineal, utilizando o ultrassom anorretal tri-dimensional dinÃmico (ecodefecografia), comparando com a proctografia evacuatÃria dinÃmica convencional. Secundariamente, foram comparados os achados das demais alteraÃÃes anÃtomo-funcionais do assoalho pÃlvico ocorridas no compartimento posterior (anismus, retocele e intussuscepÃÃo retal) diagnosticadas pela proctografia evacuatÃria dinÃmica e pela ecodefecografia. Foram avaliadas 29 mulheres adultas, com idade mÃdia de 47,7 anos (23-74) e sintomas de evacuaÃÃo obstruÃda, com escore mÃdio de 10 pontos (7-14), segundo o Sistema de ClassificaÃÃo da Cleveland Clinic para constipaÃÃo. Todas as pacientes foram submetidas à proctografia evacuatÃria dinÃmica e à ecodefecografia. Os parÃmetros avaliados, comparativamente, incluÃram a determinaÃÃo, em centÃmetros, dos valores do limite mÃximo de descenso perineal fisiolÃgico e do limite mÃnimo de descenso perineal excessivo, para a padronizaÃÃo de valores numÃricos à ecodefecografia, e a determinaÃÃo das demais alteraÃÃes anÃtomo-funcionais do compartimento posterior do assoalho pÃlvico (anismus, retocele e intussuscepÃÃo retal). à ecodefecografia, a tÃcnica para descenso perineal consistiu em escaneamento com transdutor posicionado na borda proximal do mÃsculo puborretal, por trÃs segundos, seguindo-se o esforÃo evacuatÃrio mÃximo. Com transdutor em posiÃÃo fixa, seguia-se no monitor a visualizaÃÃo da seqÃÃncia automÃtica das imagens, sendo evidenciada a borda proximal do puborretal no repouso atà a identificaÃÃo do puborretal no seu mÃximo deslocamento. 12 pacientes foram diagnosticadas com descenso perineal excessivo à proctografia evacuatÃria dinÃmica. Destas, 10 apresentaram o deslocamento do mÃsculo puborretal, no esforÃo evacuatÃrio mÃximo, maior que 2,5cm, à ecodefecografia. Portanto, estabeleceu-se que a descida do puborretal maior que 2,5cm determina o diagnÃstico de descenso perineal excessivo à ecodefecografia. 17 pacientes foram diagnosticadas sem descenso perineal tanto à proctografia evacuatÃria dinÃmica quanto à ecodefecografia. O Ãndice Kappa de concordÃncia entre os dois exames, para este parÃmetro, foi quase perfeito, de 0,854 (IC95%: 0,494â1,0; p<0,001). A avaliaÃÃo das demais alteraÃÃes anÃtomo-funcionais do compartimento posterior pÃlvico, quando comparados os exames, demonstrou Ãndice Kappa de concordÃncia substancial, de 0,649 (IC95%: 0,286â1,0; p<0,001) para avaliaÃÃo do anismus; Kappa de concordÃncia quase perfeita, de 0,868 (IC95%: 0,508â1,0; p<0,001) para avaliaÃÃo da presenÃa de retocele; Kappa de concordÃncia moderada, de 0,455 (IC95%: 0,174â0,798; p<0,007) para avaliaÃÃo da presenÃa de intussuscepÃÃo retal. Conclui-se que a ecodefecografia demonstrou ser mÃtodo aplicÃvel para avaliar descenso perineal, sendo padronizados tÃcnica e valores para o diagnÃstico de descenso perineal fisiolÃgico e excessivo, e para avaliar as demais disfunÃÃes do assoalho pÃlvico no compartimento posterior. / The main purpose of the study was to describe a novel 3-D dynamic anorectal ultrasonography technique (3-DAUS, or echodefecography) for the assessment of perineal descent and establishment of normal range values compared to dynamic evacuation proctography (DEP). Secondarily, the study compared the ability of the two techniques to identify various pelvic floor dysfunctions, including anismus, rectocele and rectal intussusception. Twenty-nine women aged 47.7 years (range: 23â74) with symptoms of obstructed evacuation were evaluated. The mean Cleveland Clinic Constipation Score was 10 (range: 7â14). All patients were submitted to DEP and 3-DAUS. Based on a comparison with DEP, normal range values (cm) of perineal descent were established for the 3-DAUS technique; anismus, rectocele and intussusceptions were also evaluated. The technique for the assessment of perineal descent at 3-DAUS started with a 3-second scan with the transducer positioned at the proximal border of the puborectal muscle (PR). The patient was then asked to strain maximally. Without displacing the transducer, a series of images were acquired and recorded automatically until the PR returned into view. Twelve patients were diagnosed with excessive perineal descent on DEP. Of these, 10 presented perineal descent >2.5cm during maximal straining on 3-DAUS. Thus, a displacement of the puborectal muscle >2.5cm was considered diagnostic of excessive perineal descent on 3-DAUS. Seventeen patients had no excessive perineal descent with either scanning technique. The Kappa index showed an almost perfect agreement between the techniques for the diagnosis of perineal descent: 0.854 (CI95%: 0,494-1,0; p<0.001). Likewise, agreement between the techniques was substantial for animus (Kappa: 0.649; CI95%: 0,286-1,0; p<0.001), almost perfect for rectocele (Kappa: 0.868; CI95%: 0,508-1,0; p<0.001) and moderate for rectal intussusception (Kappa: 0.455; CI95%: 0,174-0,798; p<0.007). In conclusion, 3-DAUS was shown to be a reliable technique for the assessment of perineal descent and pelvic floor dysfunctions, with findings confirmed by DEP.
2

Dynamic two-dimensional anorretal ultrasound in the diagnosis of Anismus in adult women - comparative study to the anal manometria and dynamic three-dimensional anorretal ultrasound / Ultra-som anorretal bi-dimensional dinÃmico no diagnÃstico de Anismus em mulheres adultas â estudo comparativo à manometria anal e ultra-som anorretal tri-dimensional dinÃmico

Rosilma Gorete Lima Barreto 30 July 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Anismus is one of the most frequent disease in carrying patients of obstructed defecation and it is being present in about 50.0% of the constipated patients. The aim of this study is to demonstrate the use of the bi-dimensional anorectal ultrasound (2-D USD) for the diagnosis of anismus and comparing the results with the anus manometry and the three-dimensional anorectal ultrasound (3-D USD). Sixty adult women with obstructed defecation symptoms were evaluated in this prospective and comparative study, coming from Colorectal Unit of the Hospital UniversitÃrio Walter CantÃdio of the Universidade Federal do CearÃ, between September 2006 to March 2007. All the patients were initially submitted to anus manometry (BAD) and then divided in two groups with 30 patients each. Group I was formed by patients without anismus at the mean age of 48,63 (24 the 69) years, while group II with carrying patients with anismus at the mean age of 51,20 (27 the 78) years. After that, patients of both groups were submitted to the 3-D and 2-D USD by an examiner who was unaware of the results of the manometries. The average size of the gotten angle with the 3-D USD at rest position of group I was 87.28  0.80 (76,5Â-96,2Â) and of 87.87  0.99 (78,5Â-109,4Â) in group II. (p=0,3220). The average size of the angle during the evacuatory effort of group I was of 93.25  1.49 (74,9Â-106,9Â) and of 85.27  1.35 (72,0Â- 101,8Â) in group II, (p=0.007). The average size of the gotten angle with the USD 2-D at rest positions of group I was 62.61  1.15 (50,9Â-75,0Â) and of 65.51  0.89 (50,8Â-73,0Â) in group II (p=0,0257). The average size of the angle during the evacuating effort of group I was of 59.75  1.42 (44,0Â-73,0Â) and of 69.40  1.06 (52,6Â-79,5Â) in group II, (p< 0,001). Comparing the differences of the angles size at rest position and during evacuatory effort of the patients of group I with group II, using 2-D and 3-D USD, there was statistically significant difference (p< 0,0001). Comparing the results between the 2-D USD with the manometry, there was agreement in 86,67% and 83,33% of the patients of group I and group II respectivelly. Comparing the results between the 2-D and 3-D USD, there was agreement of 93,33% in the evaluation of the patients of group I and of 90,0% of the patients of group II. The agreement among the three methods was 86,67% as positive predictive value and 83.33% as negative predictive value. It is concluded that the use the 2-D USD was considered efficient in the diagnosis of anismus by the high indication of agreement among the three used methods / Anismus à uma das afecÃÃes mais freqÃentes em pacientes portadores de evacuaÃÃo obstruÃda, estando presente em cerca de 50.0% dos pacientes constipados. O objetivo deste trabalho à avaliar se o USD 2-D faz o diagnÃstico de anismus, quando comparado a manometria anal e ao USD 3-D. Foram avaliadas neste estudo prospectivo e comparativo 60 mulheres adultas com sintomas de evacuaÃÃo obstruÃda, provenientes do ServiÃo de Coloproctologia do Hospital UniversitÃrio Walter CantÃdio da Universidade Federal do CearÃ, no perÃodo entre setembro de 2006 a marÃo de 2007. Todas as pacientes foram inicialmente submetidas à manometria anal (MA) e, distribuidas em dois grupos com 30 pacientes cada. O grupo I foi constituÃdo por pacientes sem anismus e com mÃdia de idade 48,63 (24 a 69) anos, enquanto o grupo II com pacientes portadoras de anismus e com mÃdia de idade 51,20 (27 a 78) anos. Em seguida, as pacientes de ambos os grupos foram submetidas à USD 3-D E 2-D por um examinador que desconhecia o resultado da manometria. O tamanho mÃdio do Ãngulo obtido com o USD 3-D no repouso do grupo I foi 87.28  0.80 (76,5Â-96,2Â) e de 87.87  0.99 (78,5Â-109,4Â) no grupo II. (p=0,3220). O tamanho mÃdio do Ãngulo no esforÃo evacuatÃrio do grupo I foi de 93.25  1.49Â(74,9Â-106,9Â) e de 85.27  1.35Â(72,0Â-101,8Â) no grupo II, (p=0.007). O tamanho mÃdio do Ãngulo obtido com a USD 2-D no repouso do grupo I foi 62.61  1.15Â(50,9Â-75,0Â) e de 65.51  0.89Â(50,8Â-73,0Â) no grupo II (p=0,0257). O tamanho mÃdio do Ãngulo no esforÃo evacuatÃrio do grupo I foi de 59.75  1.42Â(44,0Â-73,0Â) e de 69.40  1.06Â(52,6Â-79,5Â) no grupo II, (p<0.001). Comparando a diferenÃa do tamanho dos Ãngulos no repouso e no esforÃo evacuatÃrio dos pacientes do grupo I com o grupo II, ao USD 2-D e 3-D, foi observado diferenÃa estatisticamente significante (p< 0,0001). Comparando os resultados obtidos ao USD 2-D com a manometria, houve concordÃncia em 86,67% das pacientes de ambos os grupos. Comparando os resultados obtidos entre o USD 2-D com o 3-D, houve concordÃncia de 93,33% na avaliaÃÃo das pacientes do grupo I e de 90,0% das pacientes do grupo II.A concordÃncia entre os trÃs mÃtodos foi de 86,67% como valor preditivo positivo e 83,33% como valor preditivo negativo. Conclui-se que a o USD 2-D foi eficaz em averiguar o diagnÃstico do anismus pelo elevado Ãndice de concordÃncia entre os trÃs mÃtodos utilizados

Page generated in 0.0677 seconds