• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • Tagged with
  • 22
  • 22
  • 19
  • 16
  • 15
  • 13
  • 13
  • 12
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de um controlador ressonante-repetitivo aplicado a fontes de energia

Lorenzini, Charles January 2015 (has links)
Este trabalho apresenta um estudo de controladores repetitivos e ressonantes-repetitivos aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Supplies). Primeiramente, o desempenho dos controladores repetitivos é analisado a partir das exigências e dos procedimentos de testes definidos pela norma IEC 62040-3. A partir destes resultados, são discutidas as principais causas para o erro de seguimento de um sinal de referência e é avaliado o impacto de metodologias de correção aplicadas na função de transferência do controlador repetitivo. No contexto dos controladores ressonantes-repetitivos duas topologias são analisadas: a primeira é composta por um controlador ressonante sintonizado na frequência fundamental do sinal a ser seguido em paralelo com um controlador repetitivo sintonizado na mesma frequência; a segunda topologia é composta pelo mesmo paralelo entre os controladores ressonante e repetitivo, mas um filtro complementar é adicionado em série com o controlador repetitivo visando alocar a operação de cada controlador em faixas de frequências distintas. Então uma variação do controlador ressonante-repetitivo com filtro é proposta, na qual o filtro é utilizado para corrigir a fase do laço do controlador repetitivo e consequentemente aumentar a magnitude nas frequências de interesse. A partir desta estrutura proposta, uma representação no espaço de estados do sistema em malha fechada é obtida e o projeto do controlador é realizado através da solução de um problema de otimização com restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). Resultados de simulação utilizando Matlab/PSIM são apresentados para demostrar a melhoria de desempenho do sistema com o controlador proposto. / This work presents a study of repetitive and resonant-repetitive controllers applied to Uninterruptible Power Supplies (UPSs). First, the performance of repetitive controllers is analyzed in terms of requirements and test procedures defined in the IEC 62040-3 standard. From these results the main causes of the reference tracking error are discussed and the impact of correction methodologies applied to repetitive controller transfer function is evaluated. In the context of the resonant-repetitive controllers two topologies are analyzed: the first is composed of a resonant controller tuned to the fundamental frequency of the signal to be followed in parallel with a repetitive controller tuned to the same frequency; the second topology is composed of the same parallel connection between the resonant and the repetitive controllers but a complementary filter is added in series with the repetitive controller aiming to restrict each controller action to different frequency bands. Then a variation of the resonant-repetitive controller with a filter is proposed, in which the filter is used to correct the phase of the repetitive controller loop and consequently increase the magnitude at the frequencies of interest. From this proposed structure, a state space model representing the closed loop system is obtained and the controller design is carried out by the solution of an optimization problem based on LMI (Linear Matrix Inequality) constraints. Simulation results in Matlab/PSIM are presented to demonstrate the improvement on system performance with the proposed controller.
12

Desenvolvimento de um controlador ressonante-repetitivo aplicado a fontes de energia

Lorenzini, Charles January 2015 (has links)
Este trabalho apresenta um estudo de controladores repetitivos e ressonantes-repetitivos aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Supplies). Primeiramente, o desempenho dos controladores repetitivos é analisado a partir das exigências e dos procedimentos de testes definidos pela norma IEC 62040-3. A partir destes resultados, são discutidas as principais causas para o erro de seguimento de um sinal de referência e é avaliado o impacto de metodologias de correção aplicadas na função de transferência do controlador repetitivo. No contexto dos controladores ressonantes-repetitivos duas topologias são analisadas: a primeira é composta por um controlador ressonante sintonizado na frequência fundamental do sinal a ser seguido em paralelo com um controlador repetitivo sintonizado na mesma frequência; a segunda topologia é composta pelo mesmo paralelo entre os controladores ressonante e repetitivo, mas um filtro complementar é adicionado em série com o controlador repetitivo visando alocar a operação de cada controlador em faixas de frequências distintas. Então uma variação do controlador ressonante-repetitivo com filtro é proposta, na qual o filtro é utilizado para corrigir a fase do laço do controlador repetitivo e consequentemente aumentar a magnitude nas frequências de interesse. A partir desta estrutura proposta, uma representação no espaço de estados do sistema em malha fechada é obtida e o projeto do controlador é realizado através da solução de um problema de otimização com restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). Resultados de simulação utilizando Matlab/PSIM são apresentados para demostrar a melhoria de desempenho do sistema com o controlador proposto. / This work presents a study of repetitive and resonant-repetitive controllers applied to Uninterruptible Power Supplies (UPSs). First, the performance of repetitive controllers is analyzed in terms of requirements and test procedures defined in the IEC 62040-3 standard. From these results the main causes of the reference tracking error are discussed and the impact of correction methodologies applied to repetitive controller transfer function is evaluated. In the context of the resonant-repetitive controllers two topologies are analyzed: the first is composed of a resonant controller tuned to the fundamental frequency of the signal to be followed in parallel with a repetitive controller tuned to the same frequency; the second topology is composed of the same parallel connection between the resonant and the repetitive controllers but a complementary filter is added in series with the repetitive controller aiming to restrict each controller action to different frequency bands. Then a variation of the resonant-repetitive controller with a filter is proposed, in which the filter is used to correct the phase of the repetitive controller loop and consequently increase the magnitude at the frequencies of interest. From this proposed structure, a state space model representing the closed loop system is obtained and the controller design is carried out by the solution of an optimization problem based on LMI (Linear Matrix Inequality) constraints. Simulation results in Matlab/PSIM are presented to demonstrate the improvement on system performance with the proposed controller.
13

Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)

Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
14

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
15

Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)

Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
16

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
17

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
18

Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)

Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
19

CONTROLE DE CORRENTE APLICADO EM INVERSOR MONOFÁSICO DE TENSÃO / CURRENT CONTROL APPLIED IN SINGLE-PHASE VOLTAGE INVERTERS

Lima, Marcel Soares 20 February 2015 (has links)
Made available in DSpace on 2016-08-17T14:52:39Z (GMT). No. of bitstreams: 1 DISSERTACAO_MARCEL SOARES LIMA.pdf: 17818100 bytes, checksum: 95b36384b873fd5da81040a537b53ec1 (MD5) Previous issue date: 2015-02-20 / With advancement of power electronics and the wide range of applications involving single-phase inverter voltage, current controllers has gained great prominence, because they control the flow of energy supplied to the grid or to a load and compensate some quality energy problems. For this, various techniques for controlling power has been studied in order to meet the robustness characteristics, accuracy and speed of response. In addition, another important characteristic, which has been adopted for accurately determining the choice of the current driver is the possibility of eliminating disturbances in specific frequency, such as those caused by harmonicas of the fundamental signal. This paper presents the study, analysis and resonant controller design. Since this controller is equivalent to adding two PI controllers synchronously, a positive sequence and negative sequence other, implemented in the stationary frame of reference, we will investigate the possible resonance structures of controlling synchronous equivalent to PI controllers, and vector classic and the advantages and disadvantages of each. The analyses of resonant controllers are held in the continuous domain and then the drivers are implemented in discrete domain, taking into account the computational delay. It is also performed the analysis and design of strategies for controlling resonant with and without a delay compensator. Finally, experimental tests will be performed to confirm the analyzes in this paper. / Com o avanço da eletrônica de potência e a vasta gama de aplicações que envolvem os inversores monofásicos de tensão, os controladores de corrente têm ganhado grande destaque, pois controlam o fluxo de energia fornecida à rede elétrica ou a uma carga e compensam alguns problemas de qualidade de energia. Para isso, diversas técnicas de controladores de corrente têm sido estudadas com o intuito de atender as características de robustez, precisão e rapidez na resposta. Além disso, outra característica importante, e que tem sido rigorosamente adotada para determinar a escolha dos controladores de corrente, é a possibilidade de eliminar distúrbios em frequências específicas, como por exemplo, aqueles causados por harmônicas do sinal fundamental. Esta dissertação apresenta o estudo, análise e projeto do controlador ressonante. Uma vez que este controlador é equivalente à adição de dois controladores PI síncronos, um de sequência positiva e outro de sequência negativa, implementados no referencial estacionário, serão investigados as possíveis estruturas dos controladores ressonantes equivalentes aos controladores PI síncronos, clássico e vetorial, bem como as vantagens e desvantagens de cada um. As análises dos controladores ressonantes são realizadas no dominio contínuo e, posteriormente, os controladores são implementados no dominio discreto, levando em consideração o atraso computacional. Também é realizada a análise e projeto das estratégias de controladores ressonantes com e sem um compensador de atraso. Por fim, serão realizados ensaios experimentais para confirmar as análises realizadas no decorrer deste trabalho.
20

Controladores baseados no princípio do modelo interno com ação Anti-Windup / Controllers basead on internal model principle with anti-windup

Soares, Claudio Eduardo 28 April 2011 (has links)
Made available in DSpace on 2016-12-12T17:38:37Z (GMT). No. of bitstreams: 1 CLAUDIO EDUARDO SOARES.pdf: 20046362 bytes, checksum: 135e6d7d3a6f98bef9152afe645904c4 (MD5) Previous issue date: 2011-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The controllers based on the internal model principle have found emphasis on control systems due to its ability to perform robust tracking of signals whose generator models are embedded in their internal structures. Controllers with integral, resonant and repetitive terms are examples of this principle. However, the control systems are subject to physical limitations that restrict their operation under certain conditions. The amplitude saturation of the control action is the most common type of restriction found in real systems. The impacts of the saturation of control action are known as windup and its consequences for systems with integral action have already been exhaustive examined. However, the impacts of saturation of control action are not restricted to this type of controller. Other controllers based on the internal model principle are also affected by the windup phenomenon due to saturation of the action control. The impacts of the windup phenomenon for resonant, multi-resonant and repetitive controllers are investigated in this dissertation and an anti-windup technique is suggested to mitigate the impacts of the control saturation on these controllers. The proposed anti-windup technique is based on the conditional integration technique, originally developed for the controllers with integral action, and it is named conditional update. Simulation results are presented to validate the proposed technique. / Os controladores baseados no princípio do modelo interno têm encontrado destaque no controle de sistemas devido a sua capacidade de realizar o rastreamento robusto dos sinais cujos modelos geradores estejam embutidos nas suas estruturas internas. Os controladores com ação integral, ressonantes e repetitivos são exemplos da aplicação deste princípio. Contudo, os sistemas de controle estão sujeitos a limitações físicas que restringem suas condições de operação. A saturação da amplitude da ação de controle é o tipo de limitação mais comum encontrada nos sistemas reais. Os impactos da saturação da ação de controle são conhecidos como windup e suas consequências para os sistemas com ação integral já foram exaustivamente analisadas. Porém, os impactos da saturação da ação de controle não se restringem a este tipo de controlador. Outros controladores baseados no princípio do modelo interno também são afetados pelo fenômeno windup decorrente da saturação da ação de controle. Os impactos do fenômeno windup sobre os controladores ressonantes, multiressonantes e repetitivos são investigados nesta dissertação e uma técnica anti-windup é sugerida para atenuar os impactos da saturação da ação de controle sobre estes controladores. A técnica anti-windup proposta é baseada na técnica da integração condicional, originalmente desenvolvida para os controladores com ação integral e, por isso, denominada de atualização condicional. Resultados de simulação são apresentados para validação da técnica proposta.

Page generated in 0.1398 seconds