• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 84
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 93
  • 93
  • 46
  • 35
  • 27
  • 26
  • 24
  • 19
  • 15
  • 14
  • 12
  • 10
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Controle PID auto-ajustável, inteligente e preditivo

Almeida, Otacilio da Mota January 2002 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica / Made available in DSpace on 2012-10-19T20:57:28Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T02:28:23Z : No. of bitstreams: 1 183135.pdf: 11455154 bytes, checksum: 78f44a203e8565a27d3d1028c137afb6 (MD5)
32

Controle de temperatura de secadores de revestimentos cerâmicos alimentados com gás natural

Bristot, Vilmar Menegon January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T01:18:41Z (GMT). No. of bitstreams: 1 189079.pdf: 2535930 bytes, checksum: 4eeb399d693e15d2488e7221d1598ac5 (MD5) / Esta dissertação, que tem um caráter teórico-prático, apresenta um estudo do processo de secagem de peças cerâmicas e analisa o projeto e ajuste do sistema de controle de temperatura de um secador vertical de ciclo contínuo. O estudo do comportamento do processo é realizado a partir de um modelo matemático obtido com dados experimentais do secador instalado na linha de produção de monoporosa da Eliane Revestimentos Cerâmicos - Unidade V, em Criciúma - SC. A partir do modelo obtido projetam-se diversas estratégias de controle clássico, controle PI, PID e uma técnica de controle preditivo, o Controle Preditivo Generalizado (GPC) baseado no preditor de Smith. A aplicação destas técnicas ao modelo simulado do secador, permite compara-las tanto do ponto de vista do comportamento dinâmico como da complexidade de implementação. As conclusões desta análise servem para indicar as modificações a serem implantadas no sistema de controle analógico existente no processo real. Finalmente, apresentam-se resultados experimentais com a utilização do controlador PI analógico instalado no processo que mostram as melhorias introduzidas no desempenho do sistema com o ajuste proposto para o controlador. Desta forma o trabalho contribui para a melhoria imediata do comportamento do secador e aponta para futuras modificações do sistema de medição e controle que permitiriam otimizar o seu desempenho.
33

Implementação e sintonia de um controlador clássico industrial PID: estudo de caso na indústria química

Cornetti, Gustavo Perrenoud [UNESP] 18 July 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-18Bitstream added on 2014-12-02T11:21:17Z : No. of bitstreams: 1 000792343.pdf: 1375935 bytes, checksum: eead910c412b75624061ec463da3bc4e (MD5) / Devido às necessidades de se automatizar parte de seu processo para garantir os resultados projetados e obter maior segurança nas operações, desenvolveu-se um projeto para a implementação de um sistema para o controle da pressão interna de um reator, em uma indústria química. Através de minuciosos estudos sobre estrutura de controle PID e métodos clássicos de sintonia de Ziegler e Nichols, e após analisar em ambientes de simulação, o comportamento da resposta da planta diante das ações de controle, foi proposto um sistema completo, contendo um modelo sintonizado de controlador PID (Proporcional, Integrativo e Derivativo) para ser integrado no Sistema Digital de Controle Distribuído (SDCD), existente na empresa, com estratégia de controle em faixa dividida. Tal sistema foi aplicado no processo real e mostrou-se eficiente e de fácil aplicabilidade, trazendo resultados satisfatórios no controle da pressão e imediatas justificativas para o investimento / Due to the need to automate part of the process to ensure the projected results and to get more operational safety, it was developed a project for the implementation of a system for internal pressure control of a reactor in a chemical industry. Through detailed studies of control structure PID and Ziegler and Nichols classic tuning methods, and after analyzing in simulation environments the behavior of plant response on control actions, it was proposed a complete system, containing a controller tuned model PID (Proportional, Integrative and Derivative) to be integrated into the Digital Distributed Control System, belonging the company, with split range control strategy. This system was applied to the current process and it was proved to be efficient and easily applied, bringing satisfactory results in pressure control and immediate justification for the investment
34

Controle da posição da perna de pessoas hígidas utilizando um controlador PID

Kozan, Renan Fernandes [UNESP] 31 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-31Bitstream added on 2014-06-13T20:09:41Z : No. of bitstreams: 1 kozan_rf_me_ilha.pdf: 1513619 bytes, checksum: 4155bafb25f3608bef16f25ae4874e56 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A Estimulação Elétrica Funcional (FES - Functional Electrical Stimulation) tem sido utilizada na ajuda do restabelecimento de funções motoras em pacientes hemiplégicos e paraplégicos. A estimulação aplicada em níveis adequados pode ser tão eficaz no fortalecimento muscular quanto uma contração muscular voluntária. Este trabalho faz parte de um projeto multidisciplinar que integra controle e instrumentação que tem por objetivo controlar os movimentos dos membros inferiores de pacientes paraplégicos. Utilizando um processador digital de sinais e um modelo matemático linear simplificado efetuou-se a implementação de um sistema de controle em malha fechada, por meio de um controlador PID, da posição da perna de uma pessoa hígida. Implementou-se também o circuito lógico de um estágio formador de onda de um Estimulador Elétrico Neuromuscular, utilizando LabVIEW. Os parâmetros de estirnulação podem ser alterados com agilidade e facilidade. Resultados experimentais ficaram muito próximos aos obtidos através das simulações. O sistema de controle conseguiu estabilizar a posição da perna de pessoas hígidas no ângulo desejado / The Functional Electrical Stimulation (FES) has been used to help restore motor functions of hemiplegic and paraplegic patients. The FES applied at appropriate levels can be as effective in muscle strengthening as a voluntary muscle contraction. This work is part of a multidisciplinary project that integrates control systems and instrumentation to control the movements of the lower limbs of paraplegic patients. Using a digital signal processor and a simplified linear mathematical model, a PID controller was implemented with the aim of controlling the position of the leg of healthy patients. The Neuromuscular Electrical Stimulator logic circuit was implemented using LabVIEW. The stimulation parameters can be changed easily and quickly. The experimental results were very elose to those simulated. The control system was able to stabilize the position of the leg of a patient at a desired angle
35

Eletroestimulador funcional de oito canais com malha de realimentação utilizando Controlador Digital

Junqueira, Marcos Vinícius Nascimento [UNESP] 04 October 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-10-04Bitstream added on 2014-06-13T19:48:53Z : No. of bitstreams: 1 junqueira_mvn_me_ilha.pdf: 2490518 bytes, checksum: 7e14b1f52c086453d1a4b7b8750cb97e (MD5) / Foi desenvolvido um Eletroestimulador Funcional Microcontrolado para geração de movimentos nos membros inferiores de paraplégicos, visando acelerar o processo de reabilitação. O estimulador neuromuscular é constituído por oito canais microcontrolados, com formas de onda de corrente bifásica, retangular e carga balanceada, com capacidade para fornecer correntes com amplitude de até 140 mA, utilizando modulação por largura de pulso (PWM). Foi implementado um controlador Proporcional Integral Derivativo (PID) embarcado para uso com o eletroestimulador, sendo possível determinar a energia a ser aplicada ao membro estimulado, de forma a mantê-lo em uma posição pré-estabelecida. O projeto desse controlador se baseou em um modelo matemático linear de segunda ordem, que representa o comportamento da força muscular devido a um estímulo elétrico. Para validação e teste do funcionamento do sistema, funções matemáticas que descrevem o comportamento fisiológico do membro inferior foram representadas por circuitos eletrônicos. Desta forma, neste projeto foi possível integrar o controlador, o estimulador e o modelo fisiológico do músculo, observando-se a resposta temporal durante a eletroestimulação, descartando, inicialmente, a realização de testes com pessoas, visando preservar a integridade física dos voluntários. Após a verificação do bom funcionamento do equipamento, realizou-se testes com voluntários aplicando o controle em malha fechada / A Microcontrolled Functional Electrical Stimulation (FES) system was developed for generating movements in the lower limbs of paraplegics in order to accelerate their rehabilitation process. The neuromuscular stimulator consists of eight channels, microcontrolled, rectangular, biphasic current waveform, balanced load, with the ability to deliver current with amplitude of 140 mA using pulse width modulation (PWM). A PID controller was implemented for using with the microcontrolled stimulator, and the energy to be applied to the stimulated member can be determined in order to keep the leg in a pre-determined position. The design of this controller was based on a linear second order mathematical model, which describes the behavior of a muscle strength due to an electrical stimulus. For validation and testing the microcontrolled electrical stimulator system, mathematical functions that represent the physiological behavior of the lower limbs were represented by electronic circuits. Thus, this project integrates the controller, the stimulator and the muscle model, observing the time response during electrical stimulation, avoiding testing it with patients and preserving the physical integrity of the volunteers. After verifying the proper operation of the equipment, tests with volunteers were carried out applying closed loop control
36

Implementação e sintonia de um controlador clássico industrial PID : estudo de caso na indústria química /

Cornetti, Gustavo Perrenoud. January 2014 (has links)
Orientador: Victor Orlando Gamarra Rosado / Banca: José Elias Tomazini / Banca: Luiz Eduardo Nicolini do Patrocínio Nunes / Resumo : Devido às necessidades de se automatizar parte de seu processo para garantir os resultados projetados e obter maior segurança nas operações, desenvolveu-se um projeto para a implementação de um sistema para o controle da pressão interna de um reator, em uma indústria química. Através de minuciosos estudos sobre estrutura de controle PID e métodos clássicos de sintonia de Ziegler e Nichols, e após analisar em ambientes de simulação, o comportamento da resposta da planta diante das ações de controle, foi proposto um sistema completo, contendo um modelo sintonizado de controlador PID (Proporcional, Integrativo e Derivativo) para ser integrado no Sistema Digital de Controle Distribuído (SDCD), existente na empresa, com estratégia de controle em faixa dividida. Tal sistema foi aplicado no processo real e mostrou-se eficiente e de fácil aplicabilidade, trazendo resultados satisfatórios no controle da pressão e imediatas justificativas para o investimento / Abstract: Due to the need to automate part of the process to ensure the projected results and to get more operational safety, it was developed a project for the implementation of a system for internal pressure control of a reactor in a chemical industry. Through detailed studies of control structure PID and Ziegler and Nichols classic tuning methods, and after analyzing in simulation environments the behavior of plant response on control actions, it was proposed a complete system, containing a controller tuned model PID (Proportional, Integrative and Derivative) to be integrated into the Digital Distributed Control System, belonging the company, with split range control strategy. This system was applied to the current process and it was proved to be efficient and easily applied, bringing satisfactory results in pressure control and immediate justification for the investment / Mestre
37

Eletroestimulador funcional de oito canais com malha de realimentação utilizando Controlador Digital /

Junqueira, Marcos Vinícius Nascimento. January 2013 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Carlos Antonio Alves / Banca: Uender da Costa Faria / Resumo: Foi desenvolvido um Eletroestimulador Funcional Microcontrolado para geração de movimentos nos membros inferiores de paraplégicos, visando acelerar o processo de reabilitação. O estimulador neuromuscular é constituído por oito canais microcontrolados, com formas de onda de corrente bifásica, retangular e carga balanceada, com capacidade para fornecer correntes com amplitude de até 140 mA, utilizando modulação por largura de pulso (PWM). Foi implementado um controlador Proporcional Integral Derivativo (PID) embarcado para uso com o eletroestimulador, sendo possível determinar a energia a ser aplicada ao membro estimulado, de forma a mantê-lo em uma posição pré-estabelecida. O projeto desse controlador se baseou em um modelo matemático linear de segunda ordem, que representa o comportamento da força muscular devido a um estímulo elétrico. Para validação e teste do funcionamento do sistema, funções matemáticas que descrevem o comportamento fisiológico do membro inferior foram representadas por circuitos eletrônicos. Desta forma, neste projeto foi possível integrar o controlador, o estimulador e o modelo fisiológico do músculo, observando-se a resposta temporal durante a eletroestimulação, descartando, inicialmente, a realização de testes com pessoas, visando preservar a integridade física dos voluntários. Após a verificação do bom funcionamento do equipamento, realizou-se testes com voluntários aplicando o controle em malha fechada / Abstract: A Microcontrolled Functional Electrical Stimulation (FES) system was developed for generating movements in the lower limbs of paraplegics in order to accelerate their rehabilitation process. The neuromuscular stimulator consists of eight channels, microcontrolled, rectangular, biphasic current waveform, balanced load, with the ability to deliver current with amplitude of 140 mA using pulse width modulation (PWM). A PID controller was implemented for using with the microcontrolled stimulator, and the energy to be applied to the stimulated member can be determined in order to keep the leg in a pre-determined position. The design of this controller was based on a linear second order mathematical model, which describes the behavior of a muscle strength due to an electrical stimulus. For validation and testing the microcontrolled electrical stimulator system, mathematical functions that represent the physiological behavior of the lower limbs were represented by electronic circuits. Thus, this project integrates the controller, the stimulator and the muscle model, observing the time response during electrical stimulation, avoiding testing it with patients and preserving the physical integrity of the volunteers. After verifying the proper operation of the equipment, tests with volunteers were carried out applying closed loop control / Mestre
38

Controle da posição da perna de pessoas hígidas utilizando um controlador PID /

Kozan, Renan Fernandes. January 2012 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Erica Regina Marani Daruichi Machado / Banca: Ruberlei Gaino / Resumo: A Estimulação Elétrica Funcional (FES - Functional Electrical Stimulation) tem sido utilizada na ajuda do restabelecimento de funções motoras em pacientes hemiplégicos e paraplégicos. A estimulação aplicada em níveis adequados pode ser tão eficaz no fortalecimento muscular quanto uma contração muscular voluntária. Este trabalho faz parte de um projeto multidisciplinar que integra controle e instrumentação que tem por objetivo controlar os movimentos dos membros inferiores de pacientes paraplégicos. Utilizando um processador digital de sinais e um modelo matemático linear simplificado efetuou-se a implementação de um sistema de controle em malha fechada, por meio de um controlador PID, da posição da perna de uma pessoa hígida. Implementou-se também o circuito lógico de um estágio formador de onda de um Estimulador Elétrico Neuromuscular, utilizando LabVIEW. Os parâmetros de estirnulação podem ser alterados com agilidade e facilidade. Resultados experimentais ficaram muito próximos aos obtidos através das simulações. O sistema de controle conseguiu estabilizar a posição da perna de pessoas hígidas no ângulo desejado / Abstract: The Functional Electrical Stimulation (FES) has been used to help restore motor functions of hemiplegic and paraplegic patients. The FES applied at appropriate levels can be as effective in muscle strengthening as a voluntary muscle contraction. This work is part of a multidisciplinary project that integrates control systems and instrumentation to control the movements of the lower limbs of paraplegic patients. Using a digital signal processor and a simplified linear mathematical model, a PID controller was implemented with the aim of controlling the position of the leg of healthy patients. The Neuromuscular Electrical Stimulator logic circuit was implemented using LabVIEW. The stimulation parameters can be changed easily and quickly. The experimental results were very elose to those simulated. The control system was able to stabilize the position of the leg of a patient at a desired angle / Mestre
39

Sistema de controle microprocessado para tanques para Wet-etching/cleaning em microeletronica

Lopes, Silvia Elisabeth Sauaia 12 February 1996 (has links)
Orientador: Jose Antonio Siqueira Dias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-21T10:43:13Z (GMT). No. of bitstreams: 1 Lopes_SilviaElisabethSauaia_M.pdf: 6529088 bytes, checksum: 94361c93b2fa30ab34622f13f5d2b5f3 (MD5) Previous issue date: 1996 / Resumo: Tanques para banho à temperatura constante necessitam de um sistema de controle para monitoração e controle de sua temperatura de operação e demais funções. O controle da temperatura deve ser rígido e preciso; condições de alarme e desligamento automático devem ser previstos. O presente trabalho pretende estudar, implementar e testar um protótipo de um sistema de controle microprocessado para tais tanques. Este trabalho apresenta um controlador digital do tipo PID, baseado na arquitetura do microcontrolador 8051 da Intel, com aIto desempenho, robusto, eficiente e simples, características estas comprovadas através de testes práticos realizados no final do projeto / Abstract: Tanks for constant temperature bath need a temperature and related functions moni toring and control system. Temperature control must be constant and precise; alarm and automatic switching off conditions must be provided. This work is to study, implement and test a microprocessor controller's prototype for such tanks. This work presents a digital controller with a PID control scheme, based in the architecture of the Intel' s 8051 microcontroller, with high performance, strong, efficient and simple, characteristics verified through practical tests made at the end of the project / Mestrado / Mestre em Engenharia Elétrica
40

Modelagem e desenvolvimento de estrategia de controle para o reator de sintese de dextrana

Florido, Camile 02 May 2001 (has links)
Orientador: Rubens Maciel Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-28T11:58:51Z (GMT). No. of bitstreams: 1 Florido_Camile_M.pdf: 5813413 bytes, checksum: 855765ae1c9917bf3b30c36df4e3373c (MD5) Previous issue date: 2001 / Resumo: Este trabalho tem como enfoque a modelagem e o desenvolvimento de uma estratégia de controle para um reator de síntese de dextrana. A dextrana é um biopolímero, com grande potencial de utilização em indústria cosmética e área médica; a cada faixa de peso molecular se associa uma utilidade à dextrana. Ela pode ser obtida por via enzimática, com a reação ocorrendo "in vivo" ou "in vitro". Esta é normalmente mais empregada porque é mais fácil de controlar, se comparada com a técnica "in vivo". O reator de síntese de dextrana é constituído de dois estágios, dois recipientes preenchidos com uma mistura bifásica. A reação enzimática e a dessorção da enzima ocorrem no primeiro estágio, enquanto a adsorção da enzima acontece no segundo. A enzima dextrana-sacarase e o substrato não consumido - sacarose - são reciclados continuamente. Diante destas considerações foi desenvolvido um modelo dinâmico para o processo, cujas características principais foram tomadas para tomar a representação tão real quanto possível. O modelo matemático se baseou em balanços de massa envolvendo as distribuições de enzima e de substrato entre as fases sólida e líquida; não se utilizou balanços de energia porque os efeitos térmicos foram desprezados. Os resultados obtidos através da simulação do modelo matemático, na qual se empregou o algoritmo LSODAR para a integração numérica, revelam o comportamento dinâmico natural ou "pseudo-estacionário" do sistema. Como as variáveis não atingem um valor estacionário, foi necessário desenvolver controladores capazes de manter a variável de interesse em um nível satisfatório. Tal variável - a concentração de substrato no segundo estágio - é usada para calcular a produtividade e o rendimento do processo. Foram desenvolvidos e comparados dois tipos de algoritmos de controle: um PID convencional e o algoritmo DMC para a malha SISO, utilizando o fluxo de alimentação no primeiro reator como variável manipulada. Os resultados mostram que o algoritmo DMC apresenta melhor robustez se comparado ao PID, para a maior parte dos resultados. Conclui-se, portanto, que o algoritmo de DMC convencional pode ser usado com sucesso em controle de processos com um comportamento dinâmico natural contanto que os parâmetros sejam cuidadosamente escolhidos / Abstract: This work is focused on modeling and development of a control strategy for a dextran reactor. Dextran is a biopolymer, with great potential of utilization in cosmetic industry and medica1 area. For each specific purpose, it must have suitable molecular weight. Dextran can be obtained by enzymatic path, with the reaction occurring "in vivo" or "in vitro". The latter has been chosen because it is easier to control, if compared with "in vivo" technique. The dextran reactor is constituted by two stages, two vessels filled with a two-phase mixture. Enzymatic reaction - desorption of the enzyme carries out the first stage; meanwhile, the adsorption of the enzyme takes place in the second stage. Enzyme dextran-sucrase and non-consumed substrate - sucrose - are continuously recycled. From these considerations, it was developed a dynamic model for the process, whose main characteristics were considered to make the representation as real as possible. Mathematical models were based on mass balances involving enzyme and substrate distributions between solid and liquid phases; eoergy balances were not considered because the thermal effects are oegligible. The results obtained ftom the simulation of mathematical model, using LSODAR algorithm for numerica1 iotegration, revealed the natural dynamic behavior - also called pseudo stationary behavior - of the system. The variables did not reach a stationary value, so it was necessary to develop controllers which were capable to maintain the variable of interest in a suitable leveI. This variable was the substract concentratioo on the second stage, which is used to ca1culate the productivity and the yield of the processo Two types of control algorithms were performed and compared: a conventional feedback PID and the DMC-SISO, utilizing the feed flow 00 the fIrst reactor as manipulated variable. The results showed that DMC algorithm presents a better robustness if compared to the PID, for the most part of results. It was concluded that the conventional DMC algorithm can be used successfully in control of processes with a natural dynamic behavior as long as the parameters are chosen carefully / Mestrado / Desenvolvimento de Processos Químicos

Page generated in 0.0429 seconds