• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

PLL (Phase-Locked Loop) structures for single phase and three phase systems with a high rejection capacity to sub and interharmonic / Estruturas de PLL (Phase-Locked Loop) monofÃsica e trifÃsica com alta rejeiÃÃo a sub e inter-harmÃnicas

Renato Guerreiro AraÃjo 18 November 2015 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / In applications related to power converters, such as inverters, rectifiers and the use of active filters, the synchronization method represent a very important element in the performance of the control strategy of this equipment. The estimated values of the synchronism angle, frequency and amplitude determined by the synchronization algorithms present, facing strongly distorted signals with the presence of sub and interharmonics, high errors. This study presents two algorithms: one applied on single-phase electrical systems and one applied on three-phase electrical systems, with high immunity to interharmonics and subharmonics. First are presented the main synchronization systems that are used in the electrical power systems. In addition, will be presented the main causes and consequences of the presence of subharmonics and interharmnics in the system, as well as the mathematical modeling of the two algorithms with high rejection to these disturbances. Will be presented the simulation and the experimental results of the proposed algorithms and the comparison between these synchronization methods with particular methods present in the literature. As a result of the study, it can be seen that the proposed structures present a higher response time, but the error of the estimated signal with respect the fundamental component of the input signal is lower when compared to structures such as EPLL and structures based on SOGI. It was observed that the proposed synchronization methods are enabled to estimate the synchronism angle, the frequency and the fundamental component of the input signal adequately and can be used in control strategies of power converters. / Em aplicaÃÃes relacionadas à EletrÃnica de PotÃncia, como inversores, retificadores e a utilizaÃÃo de filtros ativos, o mÃtodo de sincronizaÃÃo representa um elemento chave no desempenho da estratÃgia de controle destes equipamentos. Os valores do Ãngulo de sincronismo, frequÃncia e amplitude estimados com determinados algoritmos de sincronizaÃÃo apresentam, diante de sinais fortemente distorcidos com a presenÃa de sub e inter-harmÃnicos, erros elevados. Neste trabalho sÃo apresentados dois algoritmos: um aplicado a sistemas elÃtricos monofÃsicos e outro aplicado a sistemas elÃtricos trifÃsicos, com elevada imunidade a inter-harmÃnicos e sub-harmÃnicos. Primeiramente sÃo apresentados os principais sistemas de sincronizaÃÃo utilizados em sistemas elÃtricos de potÃncia. AlÃm disso, sÃo apresentadas as principais causas e consequÃncias da presenÃa de sub-harmÃnicos e inter-harmÃnicos no sistema, bem como a modelagem matemÃtica dos dois algoritmos com elevada rejeiÃÃo a estes distÃrbios. SÃo apresentados os resultados de simulaÃÃo e experimentais dos algoritmos propostos e a comparaÃÃo entre estes mÃtodos de sincronizaÃÃo com determinados mÃtodos presentes na literatura. Como resultado do estudo, pode-se observar que as estruturas de sincronizaÃÃo propostas apresentam um tempo de resposta mais elevado, porÃm o erro do sinal estimado em relaÃÃo a componente fundamental do sinal de entrada à inferior quando comparado a estruturas como o EPLL e estruturas baseadas no SOGI. Com isso, tem-se que as mesmas estÃo habilitadas para estimar o Ãngulo de sincronismo, a frequÃncia e a componente fundamental do sinal de entrada adequadamente e podem serem utilizadas eficientemente em estratÃgias de controle de conversores de potÃncia.

Page generated in 0.0905 seconds