• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Overvoltages and coupling effects on an ac-dc hybrid transmission system

Verdolin, Rogerio 05 1900 (has links)
Abstract Adding a dc circuit to an existing transmission line is one method of significantly increasing the power transfer capability of a transmission corridor. The resulting hybrid system has significant coupling between the ac and dc circuits, not only because of the proximity of the circuits, but also from the fact that they may share the same sending end or receiving end ac systems. The resultant interaction produces overvoltages on the dc system which can be somewhat higher than for a conventional dc scheme. This thesis investigates the overvoltages on a hybrid ac-dc transmission system and suggests some design considerations which could be taken into account to reduce stresses on certain critical components which result from such an arrangement. Blocking filters consisting of a parallel L-C combination in series with the dc converter were included to limit the flow of fundamental frequency current in the dc line. This thesis also investigates the proper blocking filter configuration to be used as an incorrectly chosen blocking filter can cause resonance overvoltages on the dc line at fundamental frequency. A method of eliminating dc components of the currents in the transformer windings of a dc converter is presented. The method uses the technique of firing angle modulation. It is shown that merely eliminating the fundamental frequency component on the dc side may not remove this dc component. The impact of such control action at one converter on the other converters in the dc transmission system is also presented. It is also shown that the undesirable side effects of such a scheme include increased generation of non-characteristic harmonies on both the ac and dc sides. The study is performed using an electromagnetic transients simulation program and theoretical calculations.
2

Overvoltages and coupling effects on an ac-dc hybrid transmission system

Verdolin, Rogerio 05 1900 (has links)
Abstract Adding a dc circuit to an existing transmission line is one method of significantly increasing the power transfer capability of a transmission corridor. The resulting hybrid system has significant coupling between the ac and dc circuits, not only because of the proximity of the circuits, but also from the fact that they may share the same sending end or receiving end ac systems. The resultant interaction produces overvoltages on the dc system which can be somewhat higher than for a conventional dc scheme. This thesis investigates the overvoltages on a hybrid ac-dc transmission system and suggests some design considerations which could be taken into account to reduce stresses on certain critical components which result from such an arrangement. Blocking filters consisting of a parallel L-C combination in series with the dc converter were included to limit the flow of fundamental frequency current in the dc line. This thesis also investigates the proper blocking filter configuration to be used as an incorrectly chosen blocking filter can cause resonance overvoltages on the dc line at fundamental frequency. A method of eliminating dc components of the currents in the transformer windings of a dc converter is presented. The method uses the technique of firing angle modulation. It is shown that merely eliminating the fundamental frequency component on the dc side may not remove this dc component. The impact of such control action at one converter on the other converters in the dc transmission system is also presented. It is also shown that the undesirable side effects of such a scheme include increased generation of non-characteristic harmonies on both the ac and dc sides. The study is performed using an electromagnetic transients simulation program and theoretical calculations.
3

Protection contre les courts-circuits des réseaux à courant continu de forte puissance / Short circuit protection of direct current electrical grid with high power

Descloux, Justine 20 September 2013 (has links)
Dans le domaine du transport de l'électricité, les qualités intrinsèques des réseaux alternatifs s'estompent devant la difficulté imposée par le transport de la puissance réactive lorsque les lignes aériennes ou, plus particulièrement, les câbles souterrains ou sous-marins atteignent des longueurs critiques. Dans le cadre des réflexions visant à exploiter au mieux les énergies renouvelables d'origine éolienne off-shore ou hydrolienne, l'hypothèse de la création d'un réseau électrique à haute tension continue pour acheminer ces énergies jusqu'aux centres de consommation est considérée. Ce travail de thèse est en lien avec le projet européen TWENTIES (Transmission system operation with large penetration of Wind and other renewable Electricity sources in Networks by means of innovative Tools and Integrated Energy Solutions, ref 249812), financé dans le cadre du programme FP7 de la Commission Européenne. Ces travaux traitent de la protection des réseaux à courant continu contre les défauts d'isolement dans les câbles et au niveau des jeux de barre. L'étude se concentre sur des réseaux multi-terminaux bouclés et/ou maillés, et propose d'étudier la faisabilité d'un plan de protection comportant un algorithme principal et un secours en cas de défaillance d'un disjoncteur. / In the area of power transmission grids, the inherent qualities of alternative current networks fade behind the difficulty imposed by the transmission of the reactive power when overhead lines or, particularly, underground or undersea cables reach critical lengths. As part of thought aimed for operate at best renewable energy resources, namely wind or marine resources, the assumption of the creation of a high voltage direct current power grid to dispatch those energies to the consumption centers is considered. This Ph.D work is linked to the European project TWENTIES (Transmission system operation with large penetration of Wind and other renewable Electricity sources in Networks by means of innovative Tools and Integrated Energy Solutions, ref 249812), funded as a part of the 7th framework program of the European Commission. This work deal with the protection of DC grids against insulation faults occurring in the cables or at a busbar. The study focusses on meshed and/or looped multi-terminal grids, and proposes to study the feasibility of a protection plan including a main protection algorithm and a backup in case of breaker failure.

Page generated in 0.1089 seconds