• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The impact of topical prostaglandin analogs on the biomechanical properties of the cornea in patients with open angle glaucoma

Meda, Roman 12 1900 (has links)
Justification: Le glaucome entraîne une perte progressive de la vision causée par la détérioration du nerf optique. Le glaucome est répandu dans le monde et cause la cécité dans environ sept millions de personnes. Le glaucome touche plus de 400 000 Canadiens et sa prévalence augmente avec le vieillissement de la population.1,2 Il s'agit d'une maladie chronique surnoise dont les symptômes se manifestent uniquement lors des stades avancés et qui peuvent mener à la cécité. Présentement, le seul moyen possible d’arrêter la progression du glaucome au stade initial est de diminuer la pression intra-oculaire (PIO). Les analogues de prostaglandines (APG) topiques sont fréquemment utilisées comme traitement de première ligne. Cependant, la recherche démontre que cette classe de médicaments peut changer certaines propriétés de la cornée, et possiblement influencer la mesure de la PIO.3 Objectif: À déterminer si l'utilisation d'APG affecte les propriétés biomécaniques de la cornée. La conclusion sera basée sur l'analyse intégrée des résultats obtenus de l'analyseur Reichert oculaire Réponse (ORA), la tonométrie par applanation de Goldmann (TAG) et la pachymétrie ultrasonographique. Le deuxième objectif potentiel de cette étude est de déterminer la corrélation, le cas échéant, entre les propriétés biomécaniques de la cornée, l'épaisseur de la cornée centrale (ECC) et la PIO chez les patients subissant un traitement d’APG topique. L'hypothèse principale de cette étude est que l’APG influence les propriétés de la cornée telles que l'épaisseur centrale, l'élasticité et la résistance. Patients et méthodes : Soixante-dix yeux de 35 patients, âgés de 50-85 ans, atteints de glaucome à angle ouvert (GAO) et traités avec APG topique ont été examinés. Seulement les sujets avec une réfraction manifeste entre -6,00 D et +4,25 D ont été inclus. Les critères d'exclusion sont: patients avec n'importe quelle autre maladie de la cornée de l’œil, telles que la dystrophie endothéliale de Fuch’s et kératocône, ou tout antécédent de traumatisme ou d'une chirurgie de la cornée, ainsi que le port de lentilles de contact. Nous avons demandé aux patients atteints du glaucome qui ont des paramètres stables et qui utilisent l’APG dans les deux yeux de cesser l’APG dans l'œil moins affecté par la PIO, et de continuer l’utilisation d’APG dans l'œil contralatéral. Le meilleur œil est défini comme celui avec moins de dommage sur le champ visuel (CV) (déviation moyenne (DM), le moins négatif) ou une PIO maximale historique plus basse si la DM est égale ou encore celui avec plus de dommage sur la tomographie par cohérence optique (TCO, Cirrus, CA) ou la tomographie confocale par balayage laser (HRT, Heidelberg, Allemagne). Toutes les mesures ont été prises avant la cessation d’APG et répétées 6 semaines après l’arrêt. Les patients ont ensuite recommencé l’utilisation d’APG et toutes les mesures ont été répétées encore une fois après une période supplémentaire de 6 semaines. Après commencer ou de changer le traitement du glaucome, le patient doit être vu environ 4-6 semaines plus tard pour évaluer l'efficacité de la goutte.4 Pour cette raison, on été décidé d'utiliser 6 semaines d'intervalle. Toutes les mesures ont été effectuées à l’institut du glaucome de Montréal par le même technicien, avec le même équipement et à la même heure de la journée. L'œil contralatéral a servi comme œil contrôle pour les analyses statistiques. La tonométrie par applanation de Goldmann a été utilisée pour mesurer la PIO, la pachymétrie ultrasonographique pour mesurer l'ECC, et l’ORA pour mesurer les propriétés biomécaniques de la cornée, incluant l'hystérèse cornéenne (HC). L’hypothèse de l'absence d'effet de l'arrêt de l’APG sur les propriétés biomécaniques a été examiné par un modèle linéaire à effets mixtes en utilisant le logiciel statistique R. Les effets aléatoires ont été définies à deux niveaux: le patient (niveau 1) et l'œil de chaque patient (niveau 2). Les effets aléatoires ont été ajoutés au modèle pour tenir compte de la variance intra-individuelle. L’âge a également été inclus dans le modèle comme variable. Les contrastes entre les yeux et les temps ont été estimés en utilisant les valeurs p ajustées pour contrôler les taux d'erreur internes de la famille en utilisant multcomp paquet dans R. Résultats: Une augmentation statistiquement significative due l 'HC a été trouvée entre les visites 1 (sur APG) et 2 (aucun APG) dans les yeux de l'étude, avec une moyenne (±erreur standard) des valeurs de 8,98 ± 0,29 mmHg et 10,35 ± 0,29 mmHg, respectivement, correspondant à une augmentation moyenne de 1,37 ± 0,18 mmHg (p <0,001). Une réduction significative de 1,25 ± 0,18 mmHg (p <0,001) a été observée entre les visites 2 et 3, avec une valeur moyenne HC finale de 9,09 ± 0,29 mmHg. En outre, une différence statistiquement significative entre l’oeil d’étude et le contrôle n'a été observée que lors de la visite 2 (1,01 ± 0,23 mmHg, p <0,001) et non lors des visites 1 et 3. Une augmentation statistiquement significative du facteur de résistance conréen (FRC) a été trouvée entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 10,23 ± 0,34 mmHg et 11,71 ± 0,34 mmHg, respectivement. Le FRC a ensuite été réduit de 1,90 ± 0,21 mmHg (p <0,001) entre les visites 2 et 3, avec une valeur moyenne FRC finale de 9,81 ± 0,34 mmHg. Une différence statistiquement significative entre l’oeil d’étude et le contrôle n'a été observée que lors de la visite 2 (1,46 ± 0,23 mmHg, p <0,001). Une augmentation statistiquement significative de l'ECC a été trouvée entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 541,83 ± 7,27 µm et 551,91 ± 7,27 µm, respectivement, ce qui correspond à une augmentation moyenne de 10,09 ± 0,94 µm (p <0,001). L'ECC a ensuite diminué de 9,40 ± 0,94 µm (p <0,001) entre les visites 2 et 3, avec une valeur moyenne finale de 542,51 ± 7,27 µm. Une différence entre l’étude et le contrôle des yeux n'a été enregistré que lors de la visite 2 (11,26 ± 1,79 µm, p <0,001). De même, on a observé une augmentation significative de la PIO entre les visites 1 et 2 dans les yeux de l'étude, avec des valeurs moyennes de 15,37 ± 0,54 mmHg et 18,37 ± 0,54 mmHg, respectivement, ce qui correspond à une augmentation moyenne de 3,0 ± 0,49 mmHg (p <0,001). Une réduction significative de 2,83 ± 0,49 mmHg (p <0,001) a été observée entre les visites 2 et 3, avec une valeur moyenne de la PIO finale de 15,54 ± 0,54 mmHg. L’oeil de contrôle et d’étude ne différaient que lors de la visite 2 (1,91 ± 0,49 mmHg, p <0,001), ce qui confirme l'efficacité du traitement de l’APG. Lors de la visite 1, le biais de la PIO (PIOcc - PIO Goldmann) était similaire dans les deux groupes avec des valeurs moyennes de 4,1 ± 0,54 mmHg dans les yeux de contrôles et de 4,8 ± 0,54 mmHg dans les yeux d’études. Lors de la visite 2, après un lavage de 6 semaines d’APG, le biais de la PIO dans l'œil testé a été réduit à 1,6 ± 0,54 mmHg (p <0,001), ce qui signifie que la sous-estimation de la PIO par TAG était significativement moins dans la visite 2 que de la visite 1. La différence en biais PIO moyenne entre l'étude et le contrôle des yeux lors de la visite 2, en revanche, n'a pas atteint la signification statistique (p = 0,124). On a observé une augmentation peu significative de 1,53 ± 0,60 mmHg (p = 0,055) entre les visites 2 et 3 dans les yeux de l'étude, avec une valeur de polarisation finale de la PIO moyenne de 3,10 ± 0,54 mmHg dans les yeux d'études et de 2,8 ± 0,54 mmHg dans les yeux de contrôles. Nous avons ensuite cherché à déterminer si une faible HC a été associée à un stade de glaucome plus avancé chez nos patients atteints du glaucome à angle ouvert traités avec l’APG. Lorsque l'on considère tous les yeux sur l’APG au moment de la première visite, aucune association n'a été trouvée entre les dommages sur le CV et l'HC. Cependant, si l'on considère seulement les yeux avec un glaucome plus avancé, une corrélation positive significative a été observée entre la DM et l'HC (B = 0,65, p = 0,003). Une HC inférieure a été associé à une valeur de DM de champ visuelle plus négative et donc plus de dommages liés au glaucome. Conclusions : Les prostaglandines topiques affectent les propriétés biomécaniques de la cornée. Ils réduisent l'hystérèse cornéenne, le facteur de résistance cornéen et l'épaisseur centrale de la cornée. On doit tenir compte de ces changements lors de l'évaluation des effets d’APG sur la PIO. Plus de recherche devrait être menées pour confirmer nos résultats. De plus, d’autres études pourraient être réalisées en utilisant des médicaments qui diminuent la PIO sans influencer les propriétés biomécaniques de la cornée ou à l'aide de tonomètre dynamique de Pascal ou similaire qui ne dépend pas des propriétés biomécaniques de la cornée. En ce qui concerne l'interaction entre les dommages de glaucome et l'hystérésis de la cornée, nous pouvons conclure qu' une HC inférieure a été associé à une valeur de DM de CV plus négative. Mots Clés glaucome - analogues de prostaglandines - hystérèse cornéenne – l’épaisseur de la cornée centrale - la pression intraoculaire - propriétés biomécaniques de la cornée. / Rationale: Glaucoma is a chronic disease that causes a gradual loss of vision due to progressive damage to the optic nerve. It is widespread in the world and causes blindness in about seven million people. In addition, it affects more than 400,000 Canadians and its prevalence is increasing with the aging of the population.1, 2 Glaucoma becomes symptomatic only in the more advanced stages of the disease, and currently, the goal of treatment is to halt the progression of the disease by lowering the intra-ocular pressure (IOP). Topical prostaglandin analogs (PGA) are currently the first line treatment, however research has shown that this class of medications may change certain properties of the cornea, and hence the measurement of IOP.3 Aim: To determine whether the use of topical prostaglandin analogs (PGA) affects the biomechanical properties of the cornea. The conclusion will be based on the integrated analysis of the data collected from the Reichert Ocular Response Analyzer (ORA), Goldmann tonometry and ultrasound pachymetry. The second potential aim of this study is to determine the correlations, if any, between the biomechanical properties of cornea, the Central Corneal Thickness (CCT) and IOP in patients undergoing topical PGA treatment. The main hypothesis of this study is that the PGA drops influence the properties of the cornea such as central thickness, elasticity and resistance. Patients and Methods: In this study, seventy eyes of 35 patients, aged 50 - 85 years, with open angle glaucoma (OAG) and treated with topical PGA were examined. Only subjects with a manifest refraction between -6.00 D and +4.25 D were included. Exclusion criteria included patients with any other corneal eye disease, such as Fuch’s endothelial dystrophy or keratoconus, or any past history of corneal trauma or surgery. Contact lens wearers were also excluded. Patients with stable glaucoma parameters who were using topical PGA in both eyes prior to the start of the study were asked to discontinue the PGA in the best eye and to continue the application of PGA to the contralateral eye. The "best" eye, representing the eye with the least amount of glaucoma-related damage, was selected based on the results of the Humphrey Visual Field (HFA, Carl Zeiss Meditec, Inc., Dublin, CA), Heidelberg Retinal Tomography (HRT II, Heidelberg Engineering GmbH, Heidelberg, Germany), Optical Coherence Tomography (CIRRUS HD-OCT, Carl Zeiss Meditec, Inc., Dublin, CA) and maximum IOP. The contralateral eye served as a control for statistical analyses. Corneal measurements were taken before PGA cessation and repeated 6 weeks after cessation. Patients then restarted the use of PGA and all measurements were repeated once more after an additional 6 weeks. After starting or changing glaucoma treatment the patient should be seen approximately 4-6 weeks later to assess efficacy of the drop.4 For this reason it was decided to use 6 weeks interval. All measurements were performed at The Montreal Glaucoma Institute by the same trained technician, with the same equipment and at the same time of day. Goldmann applanation tonometry was used to measure the patient’s intraocular pressure (IOP), ultrasound pachymetry was used to measure central corneal thickness (CCT) and the ORA provided the measurements of the corneal biomechanical properties, including corneal hysteresis (CH). The hypothesis of no effect regarding the discontinuation of PGA on the biomechanical properties was examined by a linear mixed-effect model using the nlme package in R. Random-effects was defined on two levels: the patient (level-1) and the eye within each patient (level-2). Those random-effects were added to the model to account for the intra-individual variance due to the repeated-measure design. Age was also included in the model as a covariate. Contrasts between the eyes and times were estimated using adjusted p-values to control for familywise error rate using multcomp package in R. Results: A statistically significant increase in CH was found between Visit 1 (on PGA) and Visit 2 (no PGA) in the study eyes, with mean (±Standard Error) values of 8.98 ± 0.29 mmHg and 10.35 ± 0.29 mmHg, respectively, corresponding to a mean increase of 1.37 ± 0.18 mmHg (p < 0.001). A significant reduction of 1.25 ± 0.18 mmHg (p < 0.001) was also observed between Visits 2 and 3, with a final mean CH value of 9.09 ± 0.29 mmHg. In addition, a statistically significant difference between the study and control eyes was only observed at Visit 2 (1.01 ± 0.23 mmHg; p < 0.001) and not at Visits 1 and 3. A statistically significant increase in Corneal Resistance Factor (CRF) was found between Visits 1 and 2 in the study eyes, with mean values of 10.23 ± 0.34 mmHg and 11.71 ± 0.34 mmHg, respectively. CRF was then reduced by 1.90 ± 0.21 mmHg (p < 0.001) between Visits 2 and 3, with a final mean CRF value of 9.81 ± 0.34 mmHg. A statistically significant difference between the study and control eyes was only observed at Visit 2 (1.46 ± 0.23 mmHg; p < 0.001). A statistically significant increase in CCT was found between Visits 1 and 2 in the study eyes, with mean values of 541.83 ± 7.27 µm and 551.91 ± 7.27 µm respectively, corresponding to a mean increase of 10.09 ± 0.94 µm (p < 0.001). CCT then decreased by 9.40 ± 0.94 µm (p < 0.001) between Visits 2 and 3, with a final mean value of 542.51 ± 7.27 µm. A difference between the study and control eyes was only recorded at Visit 2 (11.26 ± 1.79 µm; p < 0.001). Similarly, a significant increase in IOP was observed between Visits 1 and 2 in the study eyes, with mean values of 15.37 ± 0.54 mmHg and 18.37 ± 0.54 mmHg respectively, corresponding to a mean increase of 3.0 ± 0.49 mmHg (p < 0.001). A significant reduction of 2.83 ± 0.49 mmHg (p < 0.001) was observed between Visits 2 and 3, with a final mean IOP value of 15.54 ± 0.54 mmHg. The control and study eyes only differed at Visit 2 (1.91 ± 0.49 mmHg; p < 0.001), confirming the effectiveness of PGA treatment. At Visit 1, the IOP bias (IOPcc – Goldmann IOP) was similar in both groups, all eyes at that time being on long term PGA medication, with mean values of 4.1 ± 0.54 mmHg in the control eyes and 4.8 ± 0.54 mmHg in the study eyes. At Visit 2, after a 6 week washout of PGAs, the IOP bias in the tested eye was reduced to 1.6 ± 0.54 mmHg (p<0.001), meaning that underestimation of IOP by Goldmann tonometry was significantly less than at Visit 1. The difference in mean IOP bias between the study and control eyes at Visit 2, however, did not reach statistical significance (p= 0.124). A marginally significant increase of 1.53 ± 0.60 mmHg (p = 0.055) was observed between Visits 2 and 3 in the study eyes, with a final mean IOP bias value of 3.10 ± 0.54 mmHg in the study eyes and 2.8 ± 0.54 mmHg in the control eyes. We then tried to determine if a low CH was associated with signs of more severe glaucoma progression among our open-angle glaucoma patients treated with PGA. When considering all eyes on PGA at the time of the first Visit, no association was found between VF damage and CH. However, when considering only eyes with more advanced glaucoma, a significant positive correlation was observed between VF MD and CH (B = 0.65; p = 0.003). A lower CH was associated with a more negative visual field MD value and thus greater glaucoma-related damage. Conclusions: Topical prostaglandin analogs reduce CH, CRF, CCT and IOP in glaucomatous eyes. The changes in CH and CCT influence the measurement of IOP, and therefore, these changes should be taken into account when evaluating IOP lowering response to PGA medications. To discern an interaction between IOP and corneal hysteresis, further research should be conducted with intraocular pressure control. It can be achieved by using systemic medications that decrease IOP and do not influence biomechanical properties. It can also be achieved by using Pascal dynamic contour tonometry or a similar tonometer that does not depend on the biomechanical properties of the cornea. Regarding the interaction between severity of glaucoma damage and corneal hysteresis, it was demonstrated that a lower CH was associated with a more negative visual field MD value. Key Words glaucoma – prostaglandin analogs – corneal hysteresis – central corneal thickness – intraocular pressure – biomechanical properties of the cornea.
2

Ocular biomechanics of the anterior segment

Oehring, Daniela January 2018 (has links)
The thesis investigates methods of examining corneal biomechanics using non-contact tonometry and introduces novel techniques to investigate corneal material properties in vivo. A comprehensive systems analysis of the CorvisST (CST) and Ocular Response Analyser (ORA) was performed. Pressure sensors were used to characterisation the airflow produced by the CST and the ORA. Distinct differences were observed between the central airflow pressures between the two devices: the CST pressure was higher and of shorter duration. Scheimpflug high-speed imaging via the CST allowed components of the corneal deformation to be investigated and the development of a 3D deformation matrix (time, depth and spatial resolution) through tracing of the anterior and posterior corneal surface. Measures of whole eye movement (WEM) with CST were found to be robust. WEM demonstrated an asymmetric profile and a correction method was developed to address the corneal deformation matrix for this asymmetry. Novel methods for characterisation of intrinsic material characteristics of the cornea were developed using numerical and graphical analytical procedures. Application of these parameters was tested on enucleated porcine eyes across a wide range of manometry internal ocular pressure (MIOP). The dynamic E-Modulus was found to be most affected by MIOP change. To investigate the in vivo distribution and heterogeneity of the corneal biomechanics, a novel set-up allowed the mapping of corneal biomechanics across the cornea using the CST (central, paracentral, peripheral) and ORA (central, peripheral). Biometric and demographic grouping of subjects allowed detection of discriminating factors between individuals. The results suggest that the in vivo cornea of healthy human adults can be characterised as a viscoelastic, damped system for longitudinal strain and a highly oscillating system for lateral strain. The cornea is approximately homogenous for measures of rigidity and dynamic E-Modulus but other corneal material characteristics (longitudinal and lateral strain, hysteresis, damping and compressibility) demonstrated regional differences. The experimental design employed allowed for strict control of biometric and biomechanical intersubject variables, based on gold-standard techniques as well as newly-developed methods, thereby creating a normative database for future use.

Page generated in 0.094 seconds