• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento mecânico de cerâmicas utilizadas na confecção de próteses parciais fixas / Mechanical behavior of ceramic materials used for fixed partial dentures

Borba, Marcia 23 June 2010 (has links)
Objetivos: determinar a resistência à flexão em três pontos (f), módulo de Weibull (m), coeficiente de susceptibilidade ao crescimento subcrítico de trinca (n) e tenacidade à fratura (KIC) de três cerâmicas usadas para confecção de infraestrutura (IE) de próteses parciais fixas (PPFs) (YZ- zircônia tetragonal parcialmente estabilizada por óxido de ítrio; IZ- cerâmica a base de alumina infiltrada por vidro e reforçada com zircônia; AL alumina policristalina) e duas porcelanas (VM7 e VM9); avaliar o efeito da configuração (uma, duas ou três camadas) nos valores de f e modo de fratura dos corpos-de-prova (CP); avaliar a influência do material de IE, do tamanho dos conectores e da ciclagem mecânica (CM) na carga de fratura (CF) e distribuição de tensões de PPFs; relacionar o comportamento mecânico dos materiais cerâmicos testados na configuração de barra e de PPF. Material e Método: Foram produzidos três tipos de CP em forma de barra (2mm x 4mm x 16mm): monolítico, duas camadas e três camadas. As IE das PPFs foram confeccionadas utilizando o sistema CAD-CAM e recobertas com porcelana. Os ensaios de f foram realizados em saliva artificial a 37ºC. Os valores de m e n foram determinados pela análise de Weibull e ensaio de fadiga dinâmica, respectivamente. As PPFs foram carregadas no centro do pôntico até a fratura. Oito PPFs de cada grupo foram submetidas a CM com freqüência de 2 Hz e carga de 140 N durante 106 ciclos e, posteriormente, ensaiadas até a fratura. A distribuição de tensões nas PPFs foi avaliada com análise de elementos finitos (AEF). Os princípios da fractografia foram utilizados para determinar o padrão de fratura e os valores de KIC. Os dados de f e CF foram analisados estatisticamente com Kruskal-Wallis e Tukey (95%). Resultados: A YZ obteve o maior valor de f (860 MPa) seguida dos materiais IZ (411 MPa) e AL (474 MPa) que não apresentaram diferença estatística. Os menores valores de f foram encontrados para as porcelanas (65 MPa). Os valores de m foram semelhantes para os materiais, com exceção dos grupos IZ e VM7, que apresentaram diferença significante. Os maiores valores de n foram encontrados para as cerâmicas YZ (76) e AL (72), seguidos pela IZ (54) e pelas porcelanas (40). A YZ apresentou o maior valor de KIC. O material submetido à tensão de tração durante o ensaio determinou o valor de f das estruturas. As PPFs de YZ com conector de 16mm2 suportaram os maiores valores de CF. Houve influência significativa do tamanho de conector para o material YZ. A CM não influenciou os valores de CF das PPFs. O padrão de distribuição de tensões foi semelhante entre as PPFs. Foi observada uma boa relação entre os valores de tensão de fratura dos materiais de IE em forma de barra e de PPF. Foram encontradas diferenças no modo de falha dos CP em forma de barra e de PPF. Conclusão: a YZ apresentou o melhor comportamento mecânico tanto na configuração de barra como de PPF. / Objectives: to determine the flexural strength (f), Weibull modulus (m), slow crack growth coefficient (n) and fracture toughness (KIC) of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ- yttria partially stabilized zirconia tetragonal polycrystals; IZ- alumina-based zirconia-reinforced glass infiltrated ceramic; AL alumina polycrystals) and two veneering porcelains (VM7 and VM9); to evaluate the effect of the specimen design (one, two or three layers) in the f and fracture mode; to evaluate the influence of the framework material, connector size and mechanical cycling (MC) in the fracture load (FL) and stress distribution of FPDs; to relate the mechanical behavior of the ceramic materials tested using bar-shaped specimens and FPDs. Materials and Methods: Bar-shaped specimens (2mm x 4mm x 16mm) were produced in three different designs: monolithic, bilayer and trilayer. FPD frameworks were built using CAD-CAM system and veneered with porcelain. Specimens were tested for three point bending in 37ºC artificial saliva. Weibull analysis and dynamic fatigue testing were used to determine m and n values, respectively. FPDs were tested with a load applied in the middle of the pontic. Eight FPDs of each group were subjected to MC using a frequency of 2Hz and load of 140N for 106 cycles and were subsequently loaded to failure. Stress distribution for FPDs was evaluated using finite element analysis (FEA). Fractography principles were used to determine the fracture mode and KIC values. f and FL data were analyzed using Kruskal-Wallis and Tukey (95%). Results: YZ had the highest f value (860 MPa) followed by IZ (411 MPa) and AL (474 MPa). Lower f values were observed for the porcelains (65 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (40). YZ presented the highest KIC value. The f values were influenced by the material subjected to tensile stress during testing. YZ FPDs with 16mm2 connector showed higher FL values. There was significant influence of the connector size on the FL values for YZ material. MC had no influence in the FL values for the FPDs. The stress distribution was similar for all FPDs. Considering the framework material, there was a good agreement between the fracture strength values obtained for bar-shaped specimens and FPDs. Different fracture modes were observed for bar-shaped specimens and FPDs. Conclusion: YZ presented the best mechanical performance in both bar-shaped and FPD specimen configuration.
2

Comportamento mecânico de cerâmicas utilizadas na confecção de próteses parciais fixas / Mechanical behavior of ceramic materials used for fixed partial dentures

Marcia Borba 23 June 2010 (has links)
Objetivos: determinar a resistência à flexão em três pontos (f), módulo de Weibull (m), coeficiente de susceptibilidade ao crescimento subcrítico de trinca (n) e tenacidade à fratura (KIC) de três cerâmicas usadas para confecção de infraestrutura (IE) de próteses parciais fixas (PPFs) (YZ- zircônia tetragonal parcialmente estabilizada por óxido de ítrio; IZ- cerâmica a base de alumina infiltrada por vidro e reforçada com zircônia; AL alumina policristalina) e duas porcelanas (VM7 e VM9); avaliar o efeito da configuração (uma, duas ou três camadas) nos valores de f e modo de fratura dos corpos-de-prova (CP); avaliar a influência do material de IE, do tamanho dos conectores e da ciclagem mecânica (CM) na carga de fratura (CF) e distribuição de tensões de PPFs; relacionar o comportamento mecânico dos materiais cerâmicos testados na configuração de barra e de PPF. Material e Método: Foram produzidos três tipos de CP em forma de barra (2mm x 4mm x 16mm): monolítico, duas camadas e três camadas. As IE das PPFs foram confeccionadas utilizando o sistema CAD-CAM e recobertas com porcelana. Os ensaios de f foram realizados em saliva artificial a 37ºC. Os valores de m e n foram determinados pela análise de Weibull e ensaio de fadiga dinâmica, respectivamente. As PPFs foram carregadas no centro do pôntico até a fratura. Oito PPFs de cada grupo foram submetidas a CM com freqüência de 2 Hz e carga de 140 N durante 106 ciclos e, posteriormente, ensaiadas até a fratura. A distribuição de tensões nas PPFs foi avaliada com análise de elementos finitos (AEF). Os princípios da fractografia foram utilizados para determinar o padrão de fratura e os valores de KIC. Os dados de f e CF foram analisados estatisticamente com Kruskal-Wallis e Tukey (95%). Resultados: A YZ obteve o maior valor de f (860 MPa) seguida dos materiais IZ (411 MPa) e AL (474 MPa) que não apresentaram diferença estatística. Os menores valores de f foram encontrados para as porcelanas (65 MPa). Os valores de m foram semelhantes para os materiais, com exceção dos grupos IZ e VM7, que apresentaram diferença significante. Os maiores valores de n foram encontrados para as cerâmicas YZ (76) e AL (72), seguidos pela IZ (54) e pelas porcelanas (40). A YZ apresentou o maior valor de KIC. O material submetido à tensão de tração durante o ensaio determinou o valor de f das estruturas. As PPFs de YZ com conector de 16mm2 suportaram os maiores valores de CF. Houve influência significativa do tamanho de conector para o material YZ. A CM não influenciou os valores de CF das PPFs. O padrão de distribuição de tensões foi semelhante entre as PPFs. Foi observada uma boa relação entre os valores de tensão de fratura dos materiais de IE em forma de barra e de PPF. Foram encontradas diferenças no modo de falha dos CP em forma de barra e de PPF. Conclusão: a YZ apresentou o melhor comportamento mecânico tanto na configuração de barra como de PPF. / Objectives: to determine the flexural strength (f), Weibull modulus (m), slow crack growth coefficient (n) and fracture toughness (KIC) of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ- yttria partially stabilized zirconia tetragonal polycrystals; IZ- alumina-based zirconia-reinforced glass infiltrated ceramic; AL alumina polycrystals) and two veneering porcelains (VM7 and VM9); to evaluate the effect of the specimen design (one, two or three layers) in the f and fracture mode; to evaluate the influence of the framework material, connector size and mechanical cycling (MC) in the fracture load (FL) and stress distribution of FPDs; to relate the mechanical behavior of the ceramic materials tested using bar-shaped specimens and FPDs. Materials and Methods: Bar-shaped specimens (2mm x 4mm x 16mm) were produced in three different designs: monolithic, bilayer and trilayer. FPD frameworks were built using CAD-CAM system and veneered with porcelain. Specimens were tested for three point bending in 37ºC artificial saliva. Weibull analysis and dynamic fatigue testing were used to determine m and n values, respectively. FPDs were tested with a load applied in the middle of the pontic. Eight FPDs of each group were subjected to MC using a frequency of 2Hz and load of 140N for 106 cycles and were subsequently loaded to failure. Stress distribution for FPDs was evaluated using finite element analysis (FEA). Fractography principles were used to determine the fracture mode and KIC values. f and FL data were analyzed using Kruskal-Wallis and Tukey (95%). Results: YZ had the highest f value (860 MPa) followed by IZ (411 MPa) and AL (474 MPa). Lower f values were observed for the porcelains (65 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (40). YZ presented the highest KIC value. The f values were influenced by the material subjected to tensile stress during testing. YZ FPDs with 16mm2 connector showed higher FL values. There was significant influence of the connector size on the FL values for YZ material. MC had no influence in the FL values for the FPDs. The stress distribution was similar for all FPDs. Considering the framework material, there was a good agreement between the fracture strength values obtained for bar-shaped specimens and FPDs. Different fracture modes were observed for bar-shaped specimens and FPDs. Conclusion: YZ presented the best mechanical performance in both bar-shaped and FPD specimen configuration.
3

Crescimento de trinca subcrítico em cerâmicas odontológicas: efeito do material (microestrutura) e do método de ensaio / Growth of crack subcrítico in dental ceramics: effect of the material (Microstructure) and the test method

Gonzaga, Carla Castiglia 17 August 2007 (has links)
O objetivo deste trabalho foi realizar a caracterização microestrutural e das propriedades mecânicas de diferentes cerâmicas odontológicas para entender sua influência nos parâmetros de crescimento de trinca subcrítico (SCG), n (coeficiente de susceptibilidade ao SCG) e ?f0 (parâmetro escalar), determinados por diferentes métodos. Cinco cerâmicas foram avaliadas: porcelanas VM7 (Vita) e D (d.Sign, Ivoclar), vitrocerâmicas E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) e compósito IC (In-Ceram Alumina, Vita). Espécimes em forma de disco (12 mm x 1 mm) foram confeccionados segundo as recomendações dos fabricantes. A caracterização microestrutural dos materiais foi realizada. A tenacidade à fratura (KIc) foi determinada pelo método da fratura por indentação (IF) e indentation strength. Os parâmetros de SCG foram determinados por fadiga dinâmica (com diferentes taxas de tensão constante), fadiga estática (com diferentes níveis de tensão constante) e fadiga por IF. Os resultados mostraram que todas as cerâmicas constituíram-se de fase vítrea e cristalina, com exceção da VM7, composta somente por fase amorfa. D e E1 apresentaram partículas de leucita, em frações volumétricas iguais a 0,16 e 0,29, sendo que E1 apresentou distribuição homogênea destes cristais, enquanto que D apresentou distribuição heterogênea, formando aglomerados. E2 apresentou cristais alongados de dissilicato de lítio, em fração volumétrica de 0,58, que apresentaram tendência de alinhamento com seu maior eixo alinhado perpendicularmente à direção de compactação, que variou angularmente a partir do ponto de injeção. O compósito IC apresentou-se constituído de cristais de alumina parcialmente sinterizados (65% em volume), infiltrados por vidro de baixa fusão. Independentemente do método, IC apresentou maior tenacidade (2,81 MPa.m1/2), seguido por E2 (1,81 MPa.m1/2) e E1 (0,96 MPa.m1/2) e, por último pelas porcelanas D (0,84 MPa.m1/2) e VM7 (0,67 MPa.m1/2). A deflexão de trincas foi o principal mecanismo de tenacificação dos materiais com partículas cristalinas. Para o ensaio de fadiga dinâmica, o valor de n dependeu do material estudado, ficando entre 17,2 e 31,1. Com relação ao parâmetro ?f0, foram encontrados valores entre 48 e 384 MPa. Para materiais a base de silicato de alumínio e potássio (porcelanas VM7 e D e vitrocerâmica E1), a composição química das fases vítreas dos materiais estudados parece estar relacionada com as diferenças entre os valores de n. O parâmetro ?f0 apresentou correlação com KIc e com a microestrutura, tendendo a aumentar com o aumento da fração volumétrica de cristais. No ensaio de fadiga estática, realizado apenas com D, foram obtidos valores de n e ?f0 respectivamente iguais a 31,4 e 47 MPa, sendo considerados similares aos obtidos por fadiga dinâmica. Ao se compararem os valores de n determinados nos ensaios dinâmico e por IF, nota-se que os materiais com maior volume de fase vítrea (VM7, D e E1) apresentaram valores de n próximos para os dois métodos, ao passo que materiais com maior fração de cristais (E2 e IC), apresentaram maiores discrepâncias entre os valores de n. O ensaio de fadiga por IF também permitiu a determinação dos limites de fadiga (KI0), encontrando-se valores de entre 0,48 e 2,89 MPa.m1/2. / The objective of this study was to determine the mechanical properties and the microstructure of different dental ceramics in order to understand their influence on the slow crack growth (SCG) parameters, n (crack growth exponent) and ?f0, (scaling parameter), determined by different methods. The five ceramics tested were: porcelains VM7 (Vita) and D (d.Sign, Ivoclar), glass-ceramics E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) and composite IC (In-Ceram Alumina, Vita). Disc specimens (12 mm x 1 mm) were prepared according to manufacturers\' instructions. The microstructure of the materials was carried out. The fracture toughness (KIc) was determined by means of the indentation fracture technique (IF) and indentation strength. The slow crack growth parameters were determined by dynamic fatigue test (constant stress rate), static fatigue test (constant stress) and the indentation fracture method. The results showed that all ceramic materials were composed by glassy matrix and crystalline phases, except for VM7 (vitreous porcelain). D and E1 presented leucite particles, in volume fractions of 0.16 and 0.29. For E1, the leucite crystals were homogeneously distributed in the glassy matrix, while in D, leucite formed agglomerates. E2 presented lithium dissilicate crystals (58% in volume) that presented an alignment tendency, with their major axis oriented perpendicularly to the pressing direction, which varied angularly from the injection point. IC presented alumina crystals (65% in volume) partially sintered, infiltrated by a lanthanum glass. Regardless of the method, the fracture toughness values were higher for IC (2.81 MPa.m1/2), followed by E2 (1.81 MPa.m1/2) and E1 (0.96 MPa.m1/2), and were lower for the porcelains D (0.84 MPa.m1/2) and VM7 (0.67 MPa.m1/2). Crack deflection was the main toughening mechanism observed for the ceramics containing crystalline phases. Regarding the dynamic fatigue test, the n values depended on the material, ranging from 17,2 to 31,1. With respect to ?f0, the values obtained for this parameter ranged from 48 e 384 MPa. For the ceramics based on potassium and aluminum silicate (porcelains VM7 and D and glass-ceramic E1), the chemical composition of the glass matrix seems to be related to the differences observed in the n values. The ?f0 parameter presented a positive correlation with KIc and volume fraction of crystalline particles. For the static fatigue test, used only for porcelain D, the n and ?f0 values were, respectively, 31,4 e 47 MPa, considered similar to the ones obtained by the dynamic method. When comparing the crack growth exponents determined by the dynamic and indentation fracture tests, it can be noted that n values for the ceramics with high volume fraction of glassy phase (VM7, D and E1) were similar for both methods, but for ceramics with higher crystalline content (E2 and IC), large discrepancies were observed. The static fatigue limit (KI0) was also determined for the five materials, ranging from 0.48 e 2.89 MPa.m1/2.
4

Crescimento de trincas em fadiga torsional / Fatigue crack growth in torsional fatigue

Stryhalski, Joel 19 July 2011 (has links)
Made available in DSpace on 2016-12-08T17:19:38Z (GMT). No. of bitstreams: 1 CAPA - SUMARIO.pdf: 307847 bytes, checksum: 431911d5eb22b3080df0c9228cba482d (MD5) Previous issue date: 2011-07-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / With increasing competition and reliability in modern equipment, is of vital importance to studies on the structural fatigue life in the time domain and frequency domain, the advance speed and cost reduction in computing greatly simplifies the prediction fatigue life. But it is also necessary to know the modes of fatigue crack growth, and its mechanisms. After a review appropriate to implement a program to estimate the loss of torsional stiffness in a specimen with a crack in Mode II, was developed a device torsional fatigue tests in an attempt to identify the onset of macroscopic crack and study its growth. With learning the operation of the drive system, the system data acquisition device testing, and design and construction of an electronic circuit to shutdown device tests at the beginning of the crack in the specimen, an adequate control and calibration of these components was performed, generating confidence in that joint. This document is the experimentally determined curve of fatigue specimens of SAE 1020 Steel, Grey Cast Iron and Aluminum 6063. They also studied the failure modes of cracks from the beginning until the final rupture of the specimen to verify the failure modes, the crack initiation and propagation of macroscopic materials. It still made a numerical prediction by finite element method the size of the crack. / Com aumento da competitividade e da confiabilidade em equipamentos modernos, é de vital importância os estudos em relação à vida em fadiga estrutural no domínio do tempo e no domínio da freqüência, o avanço da velocidade e redução de custos na área computacional facilita bastante a previsão de vida em fadiga. Mas é necessário também conhecer os modos de crescimento de trinca por fadiga, e seus mecanismos. Após revisão bibliográfica adequada, com implementação de um programa para estimar a perda de rigidez torsional em um corpo de prova com trinca no Modo II, foi desenvolvido um dispositivo de testes de fadiga torsional na tentativa de identificar o início da trinca macroscópica e estudar o seu crescimento. Com o aprendizado do funcionamento do sistema de acionamento, do sistema de aquisição de dados do dispositivo de testes, e a elaboração e construção de um circuito eletrônico para desligamento do dispositivo de testes ao início da trinca no corpo de prova, um adequado controle e calibração destes componentes executou-se, gerando confiabilidade nestes conjuntos. Neste documento é determinada experimentalmente a curva de fadiga de corpos de prova de Aço SAE 1020, Ferro Fundido Cinzento e Alumínio 6063. Também são estudados os modos de falha desde o início da trinca até a ruptura final do corpo de prova para verificar os modos de falha, início e propagação da trinca macroscópica desses materiais. É feita ainda uma previsão numérica através do Método dos Elementos Finitos do tamanho da trinca.
5

Crescimento de trinca subcrítico em cerâmicas odontológicas: efeito do material (microestrutura) e do método de ensaio / Growth of crack subcrítico in dental ceramics: effect of the material (Microstructure) and the test method

Carla Castiglia Gonzaga 17 August 2007 (has links)
O objetivo deste trabalho foi realizar a caracterização microestrutural e das propriedades mecânicas de diferentes cerâmicas odontológicas para entender sua influência nos parâmetros de crescimento de trinca subcrítico (SCG), n (coeficiente de susceptibilidade ao SCG) e ?f0 (parâmetro escalar), determinados por diferentes métodos. Cinco cerâmicas foram avaliadas: porcelanas VM7 (Vita) e D (d.Sign, Ivoclar), vitrocerâmicas E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) e compósito IC (In-Ceram Alumina, Vita). Espécimes em forma de disco (12 mm x 1 mm) foram confeccionados segundo as recomendações dos fabricantes. A caracterização microestrutural dos materiais foi realizada. A tenacidade à fratura (KIc) foi determinada pelo método da fratura por indentação (IF) e indentation strength. Os parâmetros de SCG foram determinados por fadiga dinâmica (com diferentes taxas de tensão constante), fadiga estática (com diferentes níveis de tensão constante) e fadiga por IF. Os resultados mostraram que todas as cerâmicas constituíram-se de fase vítrea e cristalina, com exceção da VM7, composta somente por fase amorfa. D e E1 apresentaram partículas de leucita, em frações volumétricas iguais a 0,16 e 0,29, sendo que E1 apresentou distribuição homogênea destes cristais, enquanto que D apresentou distribuição heterogênea, formando aglomerados. E2 apresentou cristais alongados de dissilicato de lítio, em fração volumétrica de 0,58, que apresentaram tendência de alinhamento com seu maior eixo alinhado perpendicularmente à direção de compactação, que variou angularmente a partir do ponto de injeção. O compósito IC apresentou-se constituído de cristais de alumina parcialmente sinterizados (65% em volume), infiltrados por vidro de baixa fusão. Independentemente do método, IC apresentou maior tenacidade (2,81 MPa.m1/2), seguido por E2 (1,81 MPa.m1/2) e E1 (0,96 MPa.m1/2) e, por último pelas porcelanas D (0,84 MPa.m1/2) e VM7 (0,67 MPa.m1/2). A deflexão de trincas foi o principal mecanismo de tenacificação dos materiais com partículas cristalinas. Para o ensaio de fadiga dinâmica, o valor de n dependeu do material estudado, ficando entre 17,2 e 31,1. Com relação ao parâmetro ?f0, foram encontrados valores entre 48 e 384 MPa. Para materiais a base de silicato de alumínio e potássio (porcelanas VM7 e D e vitrocerâmica E1), a composição química das fases vítreas dos materiais estudados parece estar relacionada com as diferenças entre os valores de n. O parâmetro ?f0 apresentou correlação com KIc e com a microestrutura, tendendo a aumentar com o aumento da fração volumétrica de cristais. No ensaio de fadiga estática, realizado apenas com D, foram obtidos valores de n e ?f0 respectivamente iguais a 31,4 e 47 MPa, sendo considerados similares aos obtidos por fadiga dinâmica. Ao se compararem os valores de n determinados nos ensaios dinâmico e por IF, nota-se que os materiais com maior volume de fase vítrea (VM7, D e E1) apresentaram valores de n próximos para os dois métodos, ao passo que materiais com maior fração de cristais (E2 e IC), apresentaram maiores discrepâncias entre os valores de n. O ensaio de fadiga por IF também permitiu a determinação dos limites de fadiga (KI0), encontrando-se valores de entre 0,48 e 2,89 MPa.m1/2. / The objective of this study was to determine the mechanical properties and the microstructure of different dental ceramics in order to understand their influence on the slow crack growth (SCG) parameters, n (crack growth exponent) and ?f0, (scaling parameter), determined by different methods. The five ceramics tested were: porcelains VM7 (Vita) and D (d.Sign, Ivoclar), glass-ceramics E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) and composite IC (In-Ceram Alumina, Vita). Disc specimens (12 mm x 1 mm) were prepared according to manufacturers\' instructions. The microstructure of the materials was carried out. The fracture toughness (KIc) was determined by means of the indentation fracture technique (IF) and indentation strength. The slow crack growth parameters were determined by dynamic fatigue test (constant stress rate), static fatigue test (constant stress) and the indentation fracture method. The results showed that all ceramic materials were composed by glassy matrix and crystalline phases, except for VM7 (vitreous porcelain). D and E1 presented leucite particles, in volume fractions of 0.16 and 0.29. For E1, the leucite crystals were homogeneously distributed in the glassy matrix, while in D, leucite formed agglomerates. E2 presented lithium dissilicate crystals (58% in volume) that presented an alignment tendency, with their major axis oriented perpendicularly to the pressing direction, which varied angularly from the injection point. IC presented alumina crystals (65% in volume) partially sintered, infiltrated by a lanthanum glass. Regardless of the method, the fracture toughness values were higher for IC (2.81 MPa.m1/2), followed by E2 (1.81 MPa.m1/2) and E1 (0.96 MPa.m1/2), and were lower for the porcelains D (0.84 MPa.m1/2) and VM7 (0.67 MPa.m1/2). Crack deflection was the main toughening mechanism observed for the ceramics containing crystalline phases. Regarding the dynamic fatigue test, the n values depended on the material, ranging from 17,2 to 31,1. With respect to ?f0, the values obtained for this parameter ranged from 48 e 384 MPa. For the ceramics based on potassium and aluminum silicate (porcelains VM7 and D and glass-ceramic E1), the chemical composition of the glass matrix seems to be related to the differences observed in the n values. The ?f0 parameter presented a positive correlation with KIc and volume fraction of crystalline particles. For the static fatigue test, used only for porcelain D, the n and ?f0 values were, respectively, 31,4 e 47 MPa, considered similar to the ones obtained by the dynamic method. When comparing the crack growth exponents determined by the dynamic and indentation fracture tests, it can be noted that n values for the ceramics with high volume fraction of glassy phase (VM7, D and E1) were similar for both methods, but for ceramics with higher crystalline content (E2 and IC), large discrepancies were observed. The static fatigue limit (KI0) was also determined for the five materials, ranging from 0.48 e 2.89 MPa.m1/2.
6

Avaliação da propagação de trinca associada à corrosão da liga 7475 T7351 submetida a carregamentos de voos simulados / Evaluation of corrosion fatigue crack growth for 7475 T7351 alloy under spectrum loading

Chemin, Aline Emanuelle Albuquerque 13 July 2012 (has links)
A análise da vida em fadiga em amplitude variável associada à corrosão é bastante complexa, devido a combinações entre as interações eletroquímicas ocorridas, tendo em vista a exposição da frente da trinca à névoa salina somada aos efeitos deletérios do carregamento de amplitude variável. Esta combinação de efeitos ainda não é modelada matematicamente, e os dados experimentais observados em outros trabalhos ainda geram hipóteses inconclusivas. Neste contexto, este estudo tem como objetivo avaliar a vida em fadiga da liga 7475 T7351, utilizando carregamento de voos simulados TWIST e FALSTAFF e submetida a névoa salina a 3,5 e 5%. Foram executados ensaios eletroquímicos, para verificar o potencial de corrosão dessa liga e análise microestrutural para verificar a formação de pites. O crescimento de trinca por fadiga com carregamento de voo foi simulado, sem considerar os efeitos do meio, nos programas NASGRO 4.0, AFGROW e CRACK 2000, com parâmetros calibrados no NASGRO 4.0, no intuito de verificar quais modelos matemáticos e programas descrevem a curva experimental em ar com menor erro. Os resultados mostraram que os programas NASGRO 4.0 e AFGROW se aproximaram com menor erro à curva experimental em ar. Os ensaios de crescimento de trinca por fadiga foram executados com carregamento de voos simulados e os parâmetros para o sistema de geração de névoa salina foram determinados experimentalmente. As curvas de crescimento de trinca e taxa de propagação em névoa salina foram comparadas às curvas em ar, as quais também foram obtidas sob as mesmas condições de carregamento. Observou-se que para os ensaios em névoa salina, a trinca rompeu com maior número de voos em relação às curvas em ar. / The corrosion fatigue life analysis under variable amplitude loading is very complex due electrochemistry effects in crack tip exposed to salt spray matched to harmful effects of amplitude variable loading. This effects combination is not modeling mathematically actually, and the experimentally data observed in other research generates inconclusive theories. In this context, the main aim of this research to evaluate the corrosion fatigue life of 7475 T7351 under spectrum loading TWIST and FALSTAFF and exposed to 3.5% and 5% NaCl. Electrochemistry test were performed to verify the corrosion potential followed of microstructural analysis by SEM, to verify the pitting on 7475 T7351 alloy. The fatigue crack growth was simulated, without environmental effects, using the codes NASGRO, AFGROW and CRACK 2000, the simulation parameters was fit on NASGRO 4.0, to analyze whether the crack growth models and codes are able to represent properly the air experimental crack growth data. The results showed that NASGRO 4.0 and AFGROW codes described the fatigue crack growth in air with less error. The fatigue crack growth tests were performed under spectrum loadings and the parameters to obtain salt spray were determined experimentally. The corrosion fatigue crack growth and rate data were compared to air data, under the same loading conditions. The corrosion fatigue tests showed that the specimens cracked under a larger number of flights than specimens in air.
7

Avaliação da propagação de trinca associada à corrosão da liga 7475 T7351 submetida a carregamentos de voos simulados / Evaluation of corrosion fatigue crack growth for 7475 T7351 alloy under spectrum loading

Aline Emanuelle Albuquerque Chemin 13 July 2012 (has links)
A análise da vida em fadiga em amplitude variável associada à corrosão é bastante complexa, devido a combinações entre as interações eletroquímicas ocorridas, tendo em vista a exposição da frente da trinca à névoa salina somada aos efeitos deletérios do carregamento de amplitude variável. Esta combinação de efeitos ainda não é modelada matematicamente, e os dados experimentais observados em outros trabalhos ainda geram hipóteses inconclusivas. Neste contexto, este estudo tem como objetivo avaliar a vida em fadiga da liga 7475 T7351, utilizando carregamento de voos simulados TWIST e FALSTAFF e submetida a névoa salina a 3,5 e 5%. Foram executados ensaios eletroquímicos, para verificar o potencial de corrosão dessa liga e análise microestrutural para verificar a formação de pites. O crescimento de trinca por fadiga com carregamento de voo foi simulado, sem considerar os efeitos do meio, nos programas NASGRO 4.0, AFGROW e CRACK 2000, com parâmetros calibrados no NASGRO 4.0, no intuito de verificar quais modelos matemáticos e programas descrevem a curva experimental em ar com menor erro. Os resultados mostraram que os programas NASGRO 4.0 e AFGROW se aproximaram com menor erro à curva experimental em ar. Os ensaios de crescimento de trinca por fadiga foram executados com carregamento de voos simulados e os parâmetros para o sistema de geração de névoa salina foram determinados experimentalmente. As curvas de crescimento de trinca e taxa de propagação em névoa salina foram comparadas às curvas em ar, as quais também foram obtidas sob as mesmas condições de carregamento. Observou-se que para os ensaios em névoa salina, a trinca rompeu com maior número de voos em relação às curvas em ar. / The corrosion fatigue life analysis under variable amplitude loading is very complex due electrochemistry effects in crack tip exposed to salt spray matched to harmful effects of amplitude variable loading. This effects combination is not modeling mathematically actually, and the experimentally data observed in other research generates inconclusive theories. In this context, the main aim of this research to evaluate the corrosion fatigue life of 7475 T7351 under spectrum loading TWIST and FALSTAFF and exposed to 3.5% and 5% NaCl. Electrochemistry test were performed to verify the corrosion potential followed of microstructural analysis by SEM, to verify the pitting on 7475 T7351 alloy. The fatigue crack growth was simulated, without environmental effects, using the codes NASGRO, AFGROW and CRACK 2000, the simulation parameters was fit on NASGRO 4.0, to analyze whether the crack growth models and codes are able to represent properly the air experimental crack growth data. The results showed that NASGRO 4.0 and AFGROW codes described the fatigue crack growth in air with less error. The fatigue crack growth tests were performed under spectrum loadings and the parameters to obtain salt spray were determined experimentally. The corrosion fatigue crack growth and rate data were compared to air data, under the same loading conditions. The corrosion fatigue tests showed that the specimens cracked under a larger number of flights than specimens in air.

Page generated in 0.1444 seconds