Spelling suggestions: "subject:"crevice"" "subject:"srevice""
1 |
The effect of the molybdate ion on the pitting corrosion of nickel and nickel/phosphorous coatings in near neutral sodium chloride solutionsKingerley, D. G. January 2000 (has links)
No description available.
|
2 |
Crevice Corrosion in Nickel Alloy 625 in an Ocean Water EnvironmentMuñoz Salgado, Diana R. January 2017 (has links)
No description available.
|
3 |
Electrochemical neasurement of crevice corrosion of type AISI 304 stainless steelEtor, Aniekan 13 January 2010
Crevice corrosion is a form of galvanic corrosion that occurs when a metal is exposed to different environments. This occurs when the oxygen within the crevice gets depleted, thus acting as the anodic site for metal dissolution reaction. The anodic site thus encourages the migration of Cl- ions into the crevice leading to the development of an aggressive local solution. The acidic conditions present in the crevice reaches a critical crevice solution composition and results in the loss of stability of the passive film which further leads to a rapid breakdown of these films on the metal thus indicating the onset of active corrosion.<p>
In this research, it is hypothesized that the onset of crevice corrosion can be detected by measuring the galvanic coupling current between electrodes in a crevice and an external metal surface composed of the same material as the electrodes. To prove this hypothesis an engineered crevice was designed to measure IR controlled crevice currents along the crevice length of AISI 304 stainless steel immersed in a 0.5 M solution and a 1 M NaCl solution. Varying crevice openings were used to determine the effect of crevice gap (G) on the initiation of crevice corrosion and the position of the accelerated attack within the crevice.<p>
Multiplexed corrosion potential measurement and galvanic corrosion measurement techniques were used to measure the change in the open circuit potential (OCP) and the galvanic current for the four channels along the crevice length of the galvanic couple. The results obtained from the MGC test for the 100 µm crevice width immersed in 0.5 M NaCl solution showed good results with high anodic current at approximately 1 cm from the crevice mouth. This finding was in close agreement with the peak pH value observed at the position closest to the crevice mouth in the work of Alavi and Cottis (1987) and the model prediction of Kennell et al. 2009. However, for test samples with crevice width ≥ 200 µm, there was no initiation of crevice corrosion and the results obtained were discarded. The Linear polarization resistance scan and Potentiodynamic polarization scan carried out along the crevice to measure the polarization resistance, Rp , and to obtain the region of passivity along an AISI 304 SS crevice did not yield good results. Low corrosion rate in the range of 0.06 mm/yr was calculated for the AISI 304 stainless steel crevice.
|
4 |
Experimental study of reverse crevice corrosion of copperLu, Lin 09 December 2005
Crevice corrosion generally occurs on the crevice surface while the exterior or bold surfaces are not damaged. However, for copper and its alloys, the opposite is true; the bold surface is corroded while the crevice remains relatively corrosion-free. This unique type of corrosion is referred to as reverse crevice corrosion (RCC). In this research, commercially pure copper was chosen as the target metal to investigate RCC. Based on electrochemical measurements and surface analysis, reverse crevice corrosion was found to occur at room temperature. At elevated temperature only uniform corrosion was observed while under a deoxygenated environment, as expected, no corrosion was observed.<p> A multiple crevice assembly and a working electrode were designed especially for this research. Exposure test experiments were first performed at room temperature and 50 ºC. Several types of electrochemical tests were conducted including open circuit potential measurement, potentiodynamic measurement and electrochemical impendence spectroscopy (EIS). Atomic Force Microscopy (AFM) and Raman Spectroscopy were used to analyze the surfaces of the copper coupon.<p>The results of the exposure tests showed that RCC occurred at room temperature, but not at elevated temperature. Only uniform corrosion was observed at elevated temperature and no corrosion was occurred under a deoxygenated environment. It was found, based on the open circuit potential measurement, that the RCC process can be divided into three steps, a uniform corrosion phase, a corrosion slow-down step and a reverse crevice corrosion step. The first two steps can be combined into one phase, incubation phase. This hypothesis is supported with the results from Raman spectra and AFM. The EIS measurements revealed that the diffusion process from bulk solution to copper coupon surface is the rate controlling step for incubation phase and this diffusion process combined with the reduction of Cu (I) oxide in the crevice are the rate-controlling step corresponding to the last step.
|
5 |
Experimental study of reverse crevice corrosion of copperLu, Lin 09 December 2005 (has links)
Crevice corrosion generally occurs on the crevice surface while the exterior or bold surfaces are not damaged. However, for copper and its alloys, the opposite is true; the bold surface is corroded while the crevice remains relatively corrosion-free. This unique type of corrosion is referred to as reverse crevice corrosion (RCC). In this research, commercially pure copper was chosen as the target metal to investigate RCC. Based on electrochemical measurements and surface analysis, reverse crevice corrosion was found to occur at room temperature. At elevated temperature only uniform corrosion was observed while under a deoxygenated environment, as expected, no corrosion was observed.<p> A multiple crevice assembly and a working electrode were designed especially for this research. Exposure test experiments were first performed at room temperature and 50 ºC. Several types of electrochemical tests were conducted including open circuit potential measurement, potentiodynamic measurement and electrochemical impendence spectroscopy (EIS). Atomic Force Microscopy (AFM) and Raman Spectroscopy were used to analyze the surfaces of the copper coupon.<p>The results of the exposure tests showed that RCC occurred at room temperature, but not at elevated temperature. Only uniform corrosion was observed at elevated temperature and no corrosion was occurred under a deoxygenated environment. It was found, based on the open circuit potential measurement, that the RCC process can be divided into three steps, a uniform corrosion phase, a corrosion slow-down step and a reverse crevice corrosion step. The first two steps can be combined into one phase, incubation phase. This hypothesis is supported with the results from Raman spectra and AFM. The EIS measurements revealed that the diffusion process from bulk solution to copper coupon surface is the rate controlling step for incubation phase and this diffusion process combined with the reduction of Cu (I) oxide in the crevice are the rate-controlling step corresponding to the last step.
|
6 |
Electrochemical neasurement of crevice corrosion of type AISI 304 stainless steelEtor, Aniekan 13 January 2010 (has links)
Crevice corrosion is a form of galvanic corrosion that occurs when a metal is exposed to different environments. This occurs when the oxygen within the crevice gets depleted, thus acting as the anodic site for metal dissolution reaction. The anodic site thus encourages the migration of Cl- ions into the crevice leading to the development of an aggressive local solution. The acidic conditions present in the crevice reaches a critical crevice solution composition and results in the loss of stability of the passive film which further leads to a rapid breakdown of these films on the metal thus indicating the onset of active corrosion.<p>
In this research, it is hypothesized that the onset of crevice corrosion can be detected by measuring the galvanic coupling current between electrodes in a crevice and an external metal surface composed of the same material as the electrodes. To prove this hypothesis an engineered crevice was designed to measure IR controlled crevice currents along the crevice length of AISI 304 stainless steel immersed in a 0.5 M solution and a 1 M NaCl solution. Varying crevice openings were used to determine the effect of crevice gap (G) on the initiation of crevice corrosion and the position of the accelerated attack within the crevice.<p>
Multiplexed corrosion potential measurement and galvanic corrosion measurement techniques were used to measure the change in the open circuit potential (OCP) and the galvanic current for the four channels along the crevice length of the galvanic couple. The results obtained from the MGC test for the 100 µm crevice width immersed in 0.5 M NaCl solution showed good results with high anodic current at approximately 1 cm from the crevice mouth. This finding was in close agreement with the peak pH value observed at the position closest to the crevice mouth in the work of Alavi and Cottis (1987) and the model prediction of Kennell et al. 2009. However, for test samples with crevice width ≥ 200 µm, there was no initiation of crevice corrosion and the results obtained were discarded. The Linear polarization resistance scan and Potentiodynamic polarization scan carried out along the crevice to measure the polarization resistance, Rp , and to obtain the region of passivity along an AISI 304 SS crevice did not yield good results. Low corrosion rate in the range of 0.06 mm/yr was calculated for the AISI 304 stainless steel crevice.
|
7 |
Development of predictive models of flow induced and localized corrosionHeppner, Kevin L 20 September 2006
Corrosion is a serious industrial concern. According to a cost of corrosion study released in 2002, the direct cost of corrosion is approximately $276 billion dollars in the United States approximately 3.1% of their Gross Domestic Product. Key influences on the severity of corrosion include: metal and electrolyte composition, temperature, turbulent flow, and location of attack. In this work, mechanistic models of localized and flow influenced corrosion were constructed and these influences on corrosion were simulated.<p>A rigourous description of mass transport is paramount for accurate corrosion modelling. A new moderately dilute mass transport model was developed. A customized hybrid differencing scheme was used to discretize the model. The scheme calculated an appropriate upwind parameter based upon the Peclet number. Charge density effects were modelled using an algebraic charge density correction. Activity coefficients were calculated using Pitzers equations. This transport model was computationally efficient and yielded accurate simulation results relative to experimental data. Use of the hybrid differencing scheme with the mass transport equation resulted in simulation results which were up to 87% more accurate (relative to experimental data) than other conventional differencing schemes. In addition, when the charge density correction was used during the solution of the electromigration-diffusion equation, rather than solving the charge density term separately, a sixfold increase in the simulation time to real time was seen (for equal time steps in both simulation strategies). Furthermore, the charge density correction is algebraic, and thus, can be applied at larger time steps that would cause the solution of the charge density term to not converge.<p>The validated mass transport model was then applied to simulate crevice corrosion initiation of passive alloys. The cathodic reactions assumed to occur were crevice-external oxygen reduction and crevice-internal hydrogen ion reduction. Dissolution of each metal in the alloy occurred at anodic sites. The predicted transient and spatial pH profile for type 304 stainless steel was in good agreement with the independent experimental data of others. Furthermore, the pH predictions of the new model for 304 stainless steel more closely matched experimental results than previous models.<p>The mass transport model was also applied to model flow influenced CO2 corrosion. The CO2 corrosion model accounted for iron dissolution, H+, H2CO3, and water reduction, and FeCO3 film formation. The model accurately predicted experimental transient corrosion rate data.<p>Finally, a comprehensive model of crevice corrosion under the influence of flow was developed. The mass transport model was modified to account for convection. Electrode potential and current density in solution was calculated using a rigourous electrode-coupling algorithm. It was predicted that as the crevice gap to depth ratio increased, the extent of fluid penetration also increased, thereby causing crevice washout. However, for crevices with small crevice gaps, external flow increased the cathodic limiting current while fluid penetration did not occur, thereby increasing the propensity for crevice corrosion.
|
8 |
Development of predictive models of flow induced and localized corrosionHeppner, Kevin L 20 September 2006 (has links)
Corrosion is a serious industrial concern. According to a cost of corrosion study released in 2002, the direct cost of corrosion is approximately $276 billion dollars in the United States approximately 3.1% of their Gross Domestic Product. Key influences on the severity of corrosion include: metal and electrolyte composition, temperature, turbulent flow, and location of attack. In this work, mechanistic models of localized and flow influenced corrosion were constructed and these influences on corrosion were simulated.<p>A rigourous description of mass transport is paramount for accurate corrosion modelling. A new moderately dilute mass transport model was developed. A customized hybrid differencing scheme was used to discretize the model. The scheme calculated an appropriate upwind parameter based upon the Peclet number. Charge density effects were modelled using an algebraic charge density correction. Activity coefficients were calculated using Pitzers equations. This transport model was computationally efficient and yielded accurate simulation results relative to experimental data. Use of the hybrid differencing scheme with the mass transport equation resulted in simulation results which were up to 87% more accurate (relative to experimental data) than other conventional differencing schemes. In addition, when the charge density correction was used during the solution of the electromigration-diffusion equation, rather than solving the charge density term separately, a sixfold increase in the simulation time to real time was seen (for equal time steps in both simulation strategies). Furthermore, the charge density correction is algebraic, and thus, can be applied at larger time steps that would cause the solution of the charge density term to not converge.<p>The validated mass transport model was then applied to simulate crevice corrosion initiation of passive alloys. The cathodic reactions assumed to occur were crevice-external oxygen reduction and crevice-internal hydrogen ion reduction. Dissolution of each metal in the alloy occurred at anodic sites. The predicted transient and spatial pH profile for type 304 stainless steel was in good agreement with the independent experimental data of others. Furthermore, the pH predictions of the new model for 304 stainless steel more closely matched experimental results than previous models.<p>The mass transport model was also applied to model flow influenced CO2 corrosion. The CO2 corrosion model accounted for iron dissolution, H+, H2CO3, and water reduction, and FeCO3 film formation. The model accurately predicted experimental transient corrosion rate data.<p>Finally, a comprehensive model of crevice corrosion under the influence of flow was developed. The mass transport model was modified to account for convection. Electrode potential and current density in solution was calculated using a rigourous electrode-coupling algorithm. It was predicted that as the crevice gap to depth ratio increased, the extent of fluid penetration also increased, thereby causing crevice washout. However, for crevices with small crevice gaps, external flow increased the cathodic limiting current while fluid penetration did not occur, thereby increasing the propensity for crevice corrosion.
|
9 |
A Rapid Compression Machine with the Novel Concept of Crevice ContainmentBhari, Anil January 2010 (has links)
No description available.
|
10 |
Galvanically Induced/Accelerated Crevice CorrosionRoland, Zachary R. 07 June 2016 (has links)
No description available.
|
Page generated in 0.0268 seconds