• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo das interferências espectrais na determinação de cromo em diferentes matrizes por espectrometria de massas com plasma acoplado indutivamente (ICP-MS) /

Denadai, Josiane Benjamin Vera. January 2019 (has links)
Orientador: Mario Henrique Gonzalez / Coorientador: Márcia Cristina Bisinoti / Banca: Letícia Malta Costa / Banca: Mirian Cristina dos Santos / Resumo: O cromo é um contaminante inorgânico que apresenta elevado impacto ao meio ambiente e pode estar presente em algumas atividades antrópicas. Há diversos métodos para a determinação deste metal em amostras ambientais utilizando técnicas espectroanalíticas, porém, o emprego da espectrometria de massas com plasma acoplado indutivamente (ICP-MS) tem se mostrado bastante eficiente devido a possibilidade de detecção em baixas concentrações. No entanto, o estudo da remoção das interferências deve ser cautelosamente avaliado. Diferentes estratégias podem ser empregadas para reduzir essas interferências, dentre elas: equações matemáticas de correção e emprego da célula de colisão. As principais interferências espectrais foram analisadas empregando soluções de ácido nítrico, água-régia invertida e ácido cítrico em diferentes concentrações (1 - 5%) contendo concentrações pré-estabelecidas do analito (1,5 - 90 μg L-1) no modo padrão sem correções e utilizando célula de colisão com discriminação por energia cinética (KED) com vazões de gás hélio pré-definidas. Foi otimizado um método unificado para a determinação de Cr em diferentes matrizes (água, tecido de peixe e solo), empregando materiais de referência certificados (MRC's) de água (NIST1640a),tecido de peixe (DORM-4) e solo(NIST2709a)onde foram avaliadas as respostas no modo padrão sem correções; utilizando vazões distintas de hélio na célula de colisão (1 - 5 mL min-1); aplicando duas equações matemáticas de correção e equações... / Abstract: Chrome is an inorganic contaminant that has high impact to the environment and is present in some anthropic activities. There are several methods for the determination of chrome in environmental samples using spectrum-analytical techniques, however, the use of mass spectrometry with inductively coupled plasma (ICP-MS) has been very effective due to the possibility of detection in low concentrations, however the study of removals of interferences must be carefully evaluated. Different strategies may be used to reduce those interferences, among them: mathematical equations of correction and using the collision cell. In order toe valuate the main spectral interferences were analyzed solutions of nitric acid, aqua regia and citric acid in different concentrations (1 - 5%) having previously established concentrations of analyte (1.5 - 90 μg L-1) in standard mode without corrections and using collisioncell by discrimination of kinetic energy (KED) with pre-defined helium gas flows were analyzed. Subsequently, in order to develop a unified method for the determination of Cr in different matrices (water, fish tissue and soil), Certified Reference Materials (CRMs) of water (NIST1640a), fish tissue (DORM-4) andsoil (NIST 2709a)where were evaluated in standard mode without corrections; using distinct flows of Helium in the collision cell (1 - 5 mL min-1); applying two mathematical equations of correction and mathematical equations jointly with the collision cell. Statistical analyzes were ... / Mestre

Page generated in 0.0764 seconds