• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Development of an adiabatic demagnetisation refrigerator for use in space

Bromiley, Paul Ann January 2000 (has links)
No description available.
2

Particle detection with superconducting phonon sensors

Hahn, Andreas January 1994 (has links)
No description available.
3

EDELWEISS-II, direct Dark Matter search experiment : first data analysis and results

Scorza, Silvia 06 November 2009 (has links) (PDF)
One of the greatest mysteries of the universe that, for the present, puzzles the mind of most astronomers, cosmologists and physicists is the question: "What makes up our universe?". This is due to how a certain substance named Dark Matter came under speculation. It is believed this enigmatic substance, of type unknown, accounts for almost three-quarters of the cosmos within the universe, could be the answer to several questions raised by the models of the expanding universe astronomers have created, and even decide the fate of the expansion of the universe. There is strong observational evidence for the dominance of non-baryonic Dark Matter (DM) over baryonic matter in the universe. Such evidence comes from many independent observations over different length scales. The most stringent constraint on the abundance of DM comes from the analysis of the Cosmic Microwave Background (CMB) anisotropies. In particular, the WMAP (Wilkinson Microwave Anisotropy Probe) experiment restricts the abundance of matter and the abundance of baryonic matter in good agreement with predictions from Big Bang Nucleosynthesis. It is commonly believed that such a non-baryonic component could consist of new, as yet undiscovered, particles, usually referred to as WIMPs (Weakly Interacting Massive Particles). Some extensions of the standard model (SM) of particle physics predict the existence of particles that would be excellent DM candidates. In particular great attention has been dedicated to candidates arising in supersymmetric theories: the Lightest Supersymmetric Particle (LSP). In the most supersymmetric scenarios, the so-called neutralino seems to be a natural candidate, being stable in theories with conservation of R-parity and having masses and cross sections of typical WIMPs. The EDELWEISS collaboration is a direct dark matter search experiment, aiming to detect directly a WIMP interaction in a target material, high purity germanium crystal working at cryogenic temperatures. It relies in the measurement of nuclear recoils that produce measurable effects in the crystal such ionization and heat. My PhD thesis is organized as follows. The first chapter aims to provide an introduction to the theoretical framework and the scientific motivation for the following work. The nature of DM has been one of the most challenging topics in contemporary physics since the first evidences of its existence had been found in the 1930s. Cosmologists and astrophysicists on one side, together with particle theorists on the other have put a lot of effort into this field: I will briefly account for their achievements and for the experimental strategies which can be set in this scenario. Since this thesis work was carried out within the EDELWEISS-II direct dark matter experiment, I will focus the next chapter on this topic, describing the main features. The second chapter is related to the set-up of the EDELWEISS-II, the current stage of the EDELWEISS experiment necessary after a first phase that achieved the best upper limit on the WIMP elastic scattering on nucleon as a function of WIMP mass in 2004. [....]
4

Development and Performance of Detectors for the Cryogenic Dark Matter Search Experiment with an Increased Sensitivity Based on a Maximum Likelihood Analysis of Beta Contamination

Driscoll, Donald D., Jr. 14 January 2004 (has links)
No description available.
5

EDELWEISS-II, direct Dark Matter search experiment : first data analysis and results / Recherche directe de matière noire : analyse et interprétation de premières données de l'expérience EDELWEISS-II.

Scorza, Silvia 06 November 2009 (has links)
La présence de grandes quantités de matière noire invisible, c'est-à-dire non lumineuse, donc sans couplage avec les photons, autour des galaxies et à l'intérieur de leurs amas, a été confirmée par toute une série d'observations indépendantes au niveau galactique, extragalactique et cosmologique. De quoi cette matière noire est composée représente un des mystères de l'Univers qui intrigue cosmologistes et physiciens des particules. Les modèles supersymétriques proposent des candidats naturels : les WIMPs (Weakly Interacting Massive Particle). Dans la plupart des cas de figure, l'Univers est suffisamment rempli de WIMPs pour qu'il soit possible de les détecter indirectement ou directement. Pendant mon doctorat, je me suis intéressée à la recherche directe de matière noire au sein de la collaboration EDELWEISS. EDELWEISS est une expérience de recherche directe de matière noire, cette dernière interagissant avec la matière baryonique par diffusion élastique. Dans le but de mesurer les énergies des reculs nucléaires dus à ces rares interactions, EDELWEISS emploie des détecteurs cryogéniques à double composante chaleur et ionisation (de type Ge-NTD). Chacun de ces détecteurs est constitué d'un cristal de Germanium de 320g, refroidi à une température de 20 mK. La mesure simultanée de deux signaux chaleur et ionisation permet la discrimination entre les reculs électroniques et les reculs nucléaires, ces derniers étant principalement induits par des WIMPs ou des neutrons. Le coeur de mon travail de thèse a été l'analyse des données du run 8 de physique comportant 11 bolomètres caractérisés par une très bonne stabilité en termes de résolution ligne de base et correspondant à une exposition fiducielle de 93.5 kg.j. Les différentes étapes de l'analyse sont détaillées ci-dessous. J'ai commencé par l'étalonnage des détecteurs cryogéniques avec des sources gamma 133Ba et neutron Am-Be dans le but d'évaluer leurs performances dans l'environnement du nouveau cryostat EDELWEISS-II et de la nouvelle chaîne d'acquisition. Ensuite j'ai traité l'optimisation des méthodes d'analyse et des paramètres de la chaîne de lecture des données. Enfin les résultats sont interprétés en termes de limite sur la section efficace d'interaction d'un WIMP avec un nucléon en fonction de la valeur de sa masse. Pour un seuil en énergie de recul de 30 keV (choisi a priori), 3 événements ont été enregistrés dans la bande de reculs nucléaires, correspondant à une sensibilité de 5*10^-7 pb pour une masse de WIMP de 80 GeV/c^2. J'ai également mené une étude pour comprendre le bruit de fond radioactif résiduel, regardant avec attention le fond gamma et le fond beta provenant du 210Pb. Pour ce dernier, un bolomètre Ge-NTD a été équipé avec une source de 210Pb. Le fond gamma pour des énergies supérieures à 100 keV montre une réduction globale et uniforme d'un facteur deux par rapport à la première phase de l'expérience, EDELWEISS-I, arrêtée en 2004. [....] Cette étude a permis de prédire le nombre de betas de basse énergie attendus pour le run de physique. Cette prédiction se révèle compatible avec le spectre expérimental de trois événements observés dans la zone des reculs nucléaires. Néanmoins cela n'est pas suffisant pour permettre une soustraction du fond, du fait des grandes incertitudes liées au profil de collection de charge et au profil d'implantation du Pb / One of the greatest mysteries of the universe that, for the present, puzzles the mind of most astronomers, cosmologists and physicists is the question: "What makes up our universe?". This is due to how a certain substance named Dark Matter came under speculation. It is believed this enigmatic substance, of type unknown, accounts for almost three-quarters of the cosmos within the universe, could be the answer to several questions raised by the models of the expanding universe astronomers have created, and even decide the fate of the expansion of the universe. There is strong observational evidence for the dominance of non-baryonic Dark Matter (DM) over baryonic matter in the universe. Such evidence comes from many independent observations over different length scales. The most stringent constraint on the abundance of DM comes from the analysis of the Cosmic Microwave Background (CMB) anisotropies. In particular, the WMAP (Wilkinson Microwave Anisotropy Probe) experiment restricts the abundance of matter and the abundance of baryonic matter in good agreement with predictions from Big Bang Nucleosynthesis. It is commonly believed that such a non-baryonic component could consist of new, as yet undiscovered, particles, usually referred to as WIMPs (Weakly Interacting Massive Particles). Some extensions of the standard model (SM) of particle physics predict the existence of particles that would be excellent DM candidates. In particular great attention has been dedicated to candidates arising in supersymmetric theories: the Lightest Supersymmetric Particle (LSP). In the most supersymmetric scenarios, the so-called neutralino seems to be a natural candidate, being stable in theories with conservation of R-parity and having masses and cross sections of typical WIMPs. The EDELWEISS collaboration is a direct dark matter search experiment, aiming to detect directly a WIMP interaction in a target material, high purity germanium crystal working at cryogenic temperatures. It relies in the measurement of nuclear recoils that produce measurable effects in the crystal such ionization and heat. My PhD thesis is organized as follows. The first chapter aims to provide an introduction to the theoretical framework and the scientific motivation for the following work. The nature of DM has been one of the most challenging topics in contemporary physics since the first evidences of its existence had been found in the 1930s. Cosmologists and astrophysicists on one side, together with particle theorists on the other have put a lot of effort into this field: I will briefly account for their achievements and for the experimental strategies which can be set in this scenario. Since this thesis work was carried out within the EDELWEISS-II direct dark matter experiment, I will focus the next chapter on this topic, describing the main features. The second chapter is related to the set-up of the EDELWEISS-II, the current stage of the EDELWEISS experiment necessary after a first phase that achieved the best upper limit on the WIMP elastic scattering on nucleon as a function of WIMP mass in 2004. [....]
6

Sensitivity enhancement of the CUORE experiment via the development of Cherenkov hybrid TeO₂ bolometers / Amélioration de la sensibilité de l'expérience CUORE par le développement de bolomètres de TeO₂ hybrides à “lumière Cherenkov

Novati, Valentina 21 November 2018 (has links)
CUORE est la plus grande expérience qui recherche la double désintégration bêta sans neutrino avec des bolomètres de TeO₂. La découverte de cette transition nucléaire aurait des conséquences décisives sur la scène actuelle de la physique. Les questions suivantes trouveraient une réponse : pourquoi la matière est-elle dominante dans l’Univers? Quelle est la masse du neutrino? Le neutrino est il un particule de Majorana ou de Dirac? Ce travail présente deux approches différentes pour l’amélioration de la sensibilité de CUORE en vue de sa prochaine phase : CUPID. Dans la première partie de ce travail, une étude du modèle thermique pour les bolomètres équipés avec des NTDs est présentée dans le but de mieux comprendre la réponse des détecteurs de CUORE. Les bolomètres sont des détecteurs extraordinaires utilisés pour un grand nombre d’applications en raison de leurs performances remarquables, mais leur modélisation et leur simulation sont loin d’être complètement comprises. Deux mesures ont été effectuées pour évaluer expérimentalement deux paramètres du modèle thermique : la conductance de la colle et celle entre les électrons et les phonons. Dans la deuxième partie de ce travail, la possibilité de détecter la faible lumière Cherenkov émise par le TeO₂ est étudiée à fin de rejeter des événements alpha, le fond principal de l’expérience CUORE. Le défi consiste dans la détection d’un signal de lumière de 100 eV à moyen d’un détecteur équipé avec un NTD qui a normalement un bruit de l’ordre de 100 eV. Cette question peut être résolue grâce à l’effet Neganov-Trofimov-Luke (NTL) qui a permis de baisser le seuil du détecteur de lumière et d'améliorer son rapport signal-sur-bruit. Cet effet exploite la présence d’un champ électrique pour amplifier les signaux thermiques des bolomètres. Le rejet complet du fond alpha a été prouvé avec un photo-bolomètre amélioré par l’effet NTL et couplé à un bolomètre de TeO₂ comme ceux utilisés par CUORE. Une solution convaincante pour le rejet de fond alpha a été démontrée en vue de l’expérience CUPID. / CUORE is the first tonne-scale experiment searching for the neutrinoless double beta decay with TeO₂ bolometers. The discovery of this nuclear transitionwould have decisive consequences on the present physics scene. The following questions would find an answer: why is matter dominant in the Universe? which is the neutrino mass? has the neutrino a Majorana or a Dirac nature? This work presents two different approaches for the enhancement of the CUORE sensitivity with a view to its upgrade: the CUPID experiment. In the first part, a study of the thermal model describing NTD-based bolometers is presented with the objective to achieve a better comprehension of the response of the CUORE detectors. Bolometers are amazing detectors used for a large number of applications because of their impressive high performance, but their modelisation and simulation is far to be completely understood. Two measurements have been performed for an experimental evaluation of two thermal-model parameters: the glue and the electron-phonon conductances. In the second part, the possibility to detect the tiny Cherenkov light emitted by TeO₂ to reject alpha events — the main background of the CUORE experiment — is studied. The challenge consists in the detection of a 100-eV light signal with a NTD-based light detector that usually is characterised by a baseline noise of the order of 100 eV. This issue is solved with the employment of the Neganov-Trofimov-Luke (NTL) effect to lower the energy threshold of the light detector and improve its signal-to-noise ratio. This effect exploits the presence of an electric field to amplify bolometric thermal signals. The full rejection of the alpha background has been proved with one NTL assisted photo-bolometer coupled to a CUORE-size TeO₂ bolometer. A convincing solution for the alpha background rejection has been demonstrated with a view to the CUPID experiment.
7

Development of luminescent bolometers and light detectors for neutrinoless double beta decay search / Développement de bolomètres luminescents et détecteurs de lumière pour la recherche de la double désintégration bêta sans émission de neutrinos

Tenconi, Margherita 28 September 2015 (has links)
L'étude de la double désintégration bêta sans neutrinos joue un rôle important dans plusieurs questions en physique des particules et cosmologie. Ce processus nucléaire hypothétique viole la conservation du nombre leptonique par deux unités et jusqu'à présent il est le seule moyen pratique pour dévoiler la nature du neutrino : sa détection implique forcement que neutrino et antineutrino sont la même particule. En outre, le taux de décroissance est sensible à la masse efficace de Majorana du neutrino, du coup à l'échelle absolue des valeurs propres de la masse et leur hiérarchie. La marque expérimentale de la DDB0ν est un pic monochromatique dans le spectre énergétique de la somme des deux électrons émis. Le but des expériences de prochaine génération est une sensibilité sur la masse efficace du neutrino de l'ordre de dizaines de meV, c'est-à-dire demi-vies de l'ordre de 10²⁷-10²⁸ années : en pratique, il s'agit de construire des sources de quelques centaines de kg d'isotope candidat, au moins, et les sonder par des détecteurs très efficients, tout en gardant le bruit de fond dans la région énergétique d'intérêt au niveau d'un coup/tonne/an. Les bolomètres luminescents sont une technique prometteuse vu leur excellentes résolutions énergétiques, haute efficacité de détection, ample choix pour les matériaux et extensibilité modulaire à grande échelle; de plus, grâce à la détection simultanée de chaleur et lumière produites par l'interaction des particules, il est possible de discriminer les contaminations α, dangereuse source de bruit aux énergies d'intérêt pour plusieurs noyaux candidats à la DDB0ν. Cette thèse a été effectuée dans le contexte de l'expérience LUMINEU : une expérience pilote qui a pour but la construction d'une expérience de prochaine génération basée sur les bolomètres scintillants en molybdate de zinc, pour l'étude de l'isotope candidat ¹⁰⁰Mo. En vue de la construction d'une expérience à grande échelle, il est nécessaire d'effectuer des caractérisations systématiques pour s'assurer des performances et de la reproductibilité des détecteurs et leurs composantes. La disponibilité d'installations expérimentales en surface, facilement accessibles, est souhaitable pour des tests routiniers : j'ai mené la plupart des expériences au CSNSM, où j'ai aussi travaillé à l'installation d'un nouvel cryostat à dilution basé sur la technologie du Pulse-Tube. Une partie de ma thèse a concerné l'étude de détecteurs bolométriques de lumière aux absorbeurs en germanium et thermomètres NTD (thermistors Neutron Transmutation Doped) : une structure standard pour LUMINEU a été établie et on a mesuré les performances des bolomètres telles que sensibilité, résolution énergétique, bruit de base et reproductibilité. Les résultats sont satisfaisants en vue d'un emploi dans une expérience avec bolomètres scintillants, bien que la configuration soit très sensible à la microphonie. En outre, j'ai testé avec succès des détecteurs bolométriques de lumière exploitants l'effet Neganov-Luke, qui augmente le rapport signal-bruit au niveau compatible avec la détection de la lumière Cherenkov pour la discrimination des événements. Une autre partie a vu la caractérisation des bolomètres scintillants en molybdate de zinc avec masse allant jusqu'à environ 300 g : couplés aux capteurs de lumière susmentionnés et lus par thermistors NTD, ils ont été refroidis en surface au CSNSM et en endroit souterrain à Modane, dans l'installation de l'expérience EDELWEISS pour la Matière Noire. Grâce à la détection simultanée de lumière et chaleur, les interactions des particules β/γ sont séparées des contaminations α. Les résultats démontrent que la caractérisation de bolomètres massifs, presque la taille cible des détecteurs finaux, est possible même en surface, en dépit du rayonnement cosmique. En outre, ces tests ont permis d'optimiser la compatibilité de l'installation de Modane avec les exigences des bolomètres scintillants pour la recherche de la DDB0ν. / Neutrinoless Double Beta Decay (0νDBD) is regarded as an important key in the decryption of some hot astroparticle and cosmological enigmas: it violates lepton number by two units and it is currently the only known practical way to shed light on the neutrino nature, being possible only in case of a Majorana neutrino, identical to its antiparticle. Moreover, the 0νDBD rate is sensitive to the effective neutrino mass, so it would be useful to define the absolute neutrino mass scale and hierarchy. The experimental footprint of 0νDBD is a monochromatic peak in the sum energy spectrum of the two emitted electrons. Next-generation experiments aim at reaching a sensitivity on the effective neutrino mass of the order of ten meV, corresponding to half lives in the range 10²⁷-10²⁸ years: this means to be able to gather, at least, a few hundred kilograms of 0νDBD candidate isotope source and to efficiently scrutinize it with very sensitive detectors. Meanwhile, background levels in the energy region of interest of the 0νDBD signal should be lowered to less than one count/ton/y. Cryogenic luminescent bolometers are a promising technique for 0νDBD search, as they feature excellent energy resolutions, high detection efficiency, flexibility in the material choice and easy scalability to large modular experiments; furthermore, the simultaneous read-out of heat and light signals produced by particle interactions provides an active discrimination method against the dangerous α contaminations, populating the 0νDBD energy region of several interesting candidate isotopes. The work presented in this dissertation was carried out in the context of the LUMINEU project: a pilot experiment focused on zinc molybdate scintillating bolometers, to define the strategies for the construction of a next-generation experiment based on the 0νDBD candidate ¹⁰⁰Mo. In view of the construction of a large 0νDBD experiment, involving hundreds of modules, systematic cryogenic measurements have to be performed to ensure good performance and reproducibility of the detectors and their components. Aboveground facilities are preferred for routinary tests because of their easier accessibility: most of the tests were carried out at CSNSM, where I also worked on the setup of a new cryogenic apparatus, based on the Pulse-Tube technology. One part of my thesis work saw the study of bolometric light detectors based on germanium absorbers and Neutron Transmutation Doped (NTD) thermometers: a proper design was developed in view of LUMINEU and the devices were characterized in terms of sensitivity, energy resolution, baseline noise and reproducibility. The results are compatible with a 0νDBD search final experiment, though this detector configuration is very sensitive to vibrational noise. In addition, the feasibility of bolometric light detectors based on NTD thermometers and Neganov-Luke amplification was investigated, demonstrating that this technique can actually boost the signal-to-noise gain to a level compatible with event discrimination based on Cherenkov light detection. Another part of my work dealt with the test of scintillating zinc molybdate bolometers of mass up to ~300 g, coupled to the aforementioned light detectors and operated both in the aboveground facilities at CSNSM and underground at Modane, in the cryostat of the EDELWEISS Dark Matter search experiment. Good event discrimination capability was achieved: thanks to double read-out of heat and light, it is possible to identify α particles, the threatening background for 0νDBD interests, against β/γ interactions. The results proved the possibility to pre-characterize aboveground detectors of mass close to the one of a final experiment module, despite the high cosmic rays rates. Besides, the measurements opened the way to the mutual compatibility of the underground setup, conceived for another kind of experiment, and LUMINEU 0νDBD search detectors.
8

Détection directe de matière noire avec l’expérience EDELWEISS-III : étude des signaux induits par le piégeage de charges, analyse de données et caractérisation de la sensibilité des détecteurs cryogéniques aux WIMPs de basse masse / Direct detection of dark matter with the EDELWEISS-III experiment : signals induced by charge trapping, data analysis and characterization of cryogenic detector sensitivity to low-mass WIMPs

Arnaud, Quentin 02 November 2015 (has links)
L'expérience EDELWEISS-III est dédiée à la détection directe de matière noire sous forme de WIMPs. Ces particules massives devraient constituer plus de 80% de la masse de l'univers et être détectables via leur diffusion élastique sur un noyau de l'absorbeur d'un détecteur. Le taux d'événements WIMPs attendu étant très faible (<1/kg/an) , une méthode de double mesure chaleur/ionisation est réalisée afin de discriminer les reculs électroniques issus du fond et , des reculs nucléaires engendrés par les neutrons et WIMPs. Le travail de thèse a consisté en l'étude des signaux induits par le piégeage de charges. Un modèle analytique de son impact sur les signaux des voies ionisation et chaleur est présenté. Les prédictions du modèle, confortées par leur accord avec les données et une simulation numérique, ont donné lieu à diverses applications : amélioration des résolutions, sensibilité à la profondeur des dépôts d'énergie, caractérisation du piégeage de charges dans les cristaux. L'analyse des données du Run308 est détaillée et les résultats interprétés en terme de limite d'exclusion. Cette analyse a mis au jour la présence d'un bruit de fond neutron limitant pour la recherche de WIMPs de haute masse (>20GeV). La dernière partie est consacrée à une étude de l'optimisation des détecteurs cryogéniques aux WIMPs de basse masse. Ce travail, réalisée via un test statistique de rapport de vraisemblance profilé, a permis d'étudier l'influence des divers paramètres expérimentaux sur le potentiel d'exclusion. Les conclusions de cette analyse, conjointement aux résultats du Run308, ont mené l'expérience EDELWEISS à privilégier la recherche de WIMPs de basse masse (<20GeV) / The EDELWEISS-III experiment is dedicated to direct dark matter searches aiming at detecting WIMPS. These massive particles should account for more than 80% of the mass of the Universe and be detectable through their elastic scattering on nuclei constituting the absorber of a detector. As the expected WIMP event rate is extremely low (<1/kg/year), a double measurement heat/ionization is performed to discriminate electronic recoils originating from _ and backgrounds and nuclear recoils induced by neutrons and WIMPs. The first part of the thesis work consisted in studying the signals induced by charge carrier trapping. An analytical model of its impact on both ionization and heat signals is presented. The model predictions, through their agreement with both data and a numerical simulation, lead to various applications : improvement of the resolutions, statistical sensitivity to energy deposit depths, characterization of trapping within the crystals. The analysis of the Run308 data is detailed and its results are interpreted in terms of an exclusion limit on the WIMP-nucleon cross section (SI). This study brings to light the presence of a limiting neutron background for high mass WIMP searches (>20GeV). Finally, a study dedicated to the optimization of solid cryogenic detectors to low mass WIMP searches is presented. This study is performed on simulated data using a statistical test based on a profiled likelihood ratio that allows for statistical background subtraction and spectral shape discrimination. This study combined with results from Run308, has lead the EDELWEISS experiment to favor low mass WIMP searches (<20GeV)

Page generated in 0.0735 seconds