1

Προστασία ηλεκτρονικών διατάξεων από κεραυνούς

Καραγιάννης, Κωνσταντίνος 06 October 2011 (has links)
Το θέμα της παρούσας διπλωματικής εργασίας είναι η αντικεραυνική προστασία όσον αφορά ευαίσθητους ηλεκτρονικούς εξοπλισμούς και ηλεκτρικές εγκαταστάσεις. Προτού όμως αναφερθούν τρόποι και συσκευές προστασίας ή δοθούν κάποια παραδείγματα εφαρμογών σε εγκαταστάσεις και εξοπλισμούς κάποιων χωρών, πρέπει να γίνει μια εισαγωγική αναφορά γύρω από τον πυρήνα αυτής της εργασίας: τον κεραυνό. Έτσι, στο 1ο κεφάλαιο γίνεται περιγραφή κάποιων εισαγωγικών εννοιών σχετικά με τον κεραυνό. Ξεκινώντας από τη φόρτιση των σύννεφων και στο πως αυτή γίνεται, καταλήγουμε στα διάφορα είδη κεραυνών. Ακολουθεί η εξομοίωση στο εργαστήριο με ορισμένα μεγάλα διάκενα εκκένωσης του κεραυνού. Στη συνέχεια αναλύεται ο μηχανισμός των ατμοσφαιρικών εκκενώσεων μέσα από τρείς φάσεις: έναρξη οχετού (οχετός προεκκένωσης), φάση του οχετού επιστροφής και ο συνδετικός οχετός. Τέλος, γίνεται ανάλυση και μοντελοποίηση του ρεύματος κεραυνού και των παραμέτρων του. Οι βλάβες στις μονάδες ισχύος ενός υπαίθριου ηλεκτρονικού εξοπλισμού, απαντώνται συχνά εξαιτίας των κρουστικών ρευμάτων των κεραυνών που επάγονται πάνω στις AC γραμμές τροφοδοσίας. Οι αιτίες για τις βλάβες αυτές είναι ότι τα κρουστικά ρεύματα λόγω κεραυνών, ενεργοποιούν το κύκλωμα ασφαλείας της μονάδας ισχύος. Στο 2ο κεφάλαιο, για να αποσαφηνίσουμε τους μηχανισμούς των βλαβών αυτών, μετρήσαμε τα κρουστικά ρεύματα πάνω στις γραμμές. Οι μετρημένες κυματομορφές ήταν αρκετά μεγαλύτερες από τις τυποποιημένες κυματομορφές, που έχουν οριστεί από το Κ.44 του ITU-T. Επίσης, η πιθανότητα εμφάνισης κρουστικών ρευμάτων πάνω σε AC γραμμές τροφοδοσίας ήταν 20 φορές μεγαλύτερη από ότι να εμφανιστεί σε γραμμές τηλεπικοινωνιών. Όταν ένα κτίριο πλήγεται από κεραυνό, ένα μεγάλο μέρος του κρουστικού ρεύματος ρέει μέσω του συστήματος γείωσης προς το έδαφος και ένα μέρος του διαρρέει μέσω των ηλεκτρικών καλωδιώσεων του κτιρίου, οι οποίες προστατεύονται από SPD (Surge Protective Device). Στο 3ο κεφάλαιο, γίνεται αριθμητική ανάλυση της κατανομής του ρεύματος κεραυνού σε ένα πληγέν κτίριο, μέσω ενός ηλεκτρομαγνητικού και ενός κυκλωματικού μοντέλου. Σύμφωνα με την κατανομή του ρεύματος και για διάφορα συστήματα καλωδίωσης, καταλήξαμε ότι το ποσοστό του ρεύματος στις καλωδιώσεις στα υψηλότερα και στα χαμηλότερα πατώματα είναι τα μεγαλύτερο και συγκλίνει σε μία σταθερή τιμή όσο το κτίριο ψηλώνει. Όσον αφορά τα μεσαία πατώματα, είναι ασήμαντα μικρό. Αυτό το αποτέλεσμα μας είναι πάρα πολύ χρήσιμο στον προσδιορισμό της ενεργειακής κατάταξης του SPD. Συχνά ακούμε για ζημιές σε ηλεκτρικό/ηλεκτρονικό εξοπλισμό ενός κτιρίου που προκαλούνται από ρεύμα κεραυνού, ακόμα και αν η απόσταση της ηλεκτρονικής συσκευής από το σημείο πλήγματος του κεραυνού είναι μερικές εκατοντάδες μέτρα μακριά. Στο 4ο κεφάλαιο, εξετάζουμε τα ποσοστά του ρεύματος που μεταφέρονται μέσω των γραμμών τροφοδοσίας μιας κατοικημένης περιοχής από το πληγέν κτίριο στα γειτονικά του. Στο 5ο κεφάλαιο εξετάζουμε το επακόλουθο της επικίνδυνης υπέρτασης, λόγω πλήγματος κεραυνού στο LPS (Lightning Protection System) ενός κτιρίου, όπως επίσης και τα επιμέρους ρεύματα που ρέουν στις εσωτερικές εγκαταστάσεις που συνδέονται με τη ράβδο ισοδυναμικής σύνδεσης (bonding bar) και το σύστημα τερματισμού γείωσης. Μετρήσαμε τα ρεύματα κεραυνού στις εισερχόμενες γραμμές του κτιρίου για διαφορετικές εισόδους έγχυσης του κρουστικού ρεύματος, έτσι ώστε να καταλήξουμε στην κατάλληλη επιλογή και σύμπλεξη του σετ των SPD, της προστατευόμενης συσκευής χαμηλής τάσης. Επιπλέον, μετρήσαμε την κατανομή του ρεύματος και την πτώση τάσης για διαφορετικά σετ των SPD (switching και limiting) και για διαφορετικούς κατασκευαστές, σε διάφορα σημεία των μοντελοποιημένων κυκλωμάτων του οικοδομήματος. Στο 6ο κεφάλαιο, αναπτύσσονται οι δίσκοι ΖnO με ικανότητα αντοχής σε υψηλή ενέργεια, για χαμηλής τάσης συσκευές προστασίας από υπερφορτίσεις. Αυτό το πετυχαίνουμε βελτιώνοντας την χημική σύνθεση, την κατασκευαστική επεξεργασία και τον σχεδιασμό των ηλεκτροδίων των δίσκων αυτών. Οι μεταβλητές αντιστάσεις (Varistors) είναι από τα πιο κοινά χρησιμοποιούμενα προστατευτικά εξαρτήματα στα συστήματα χαμηλής τάσης. Είναι πολύ σημαντικό να εντοπίσουμε και να αντικαταστήσουμε τις φθαρμένες μεταβλητές αντιστάσεις με σκοπό να αποφύγουμε οποιεσδήποτε ζημιές στη προστατευόμενη συσκευή. Στο 7ο κεφάλαιο, μελετάμε την συμπεριφορά των χαμηλής τάσης μεταβλητών αντιστάσεων λόγω του επαναληπτικού κρουστικού ρεύματος με ρυθμό επανάληψης 10 έως 60 sec. Λεπτομερείς αναλύσεις έγιναν για να έχουμε μια ξεκάθαρη αντίληψη για τις αλλαγές των χαρακτηριστικών της μεταβλητής αντίστασης κάτω από ένα τέτοιο περιβάλλον. Οι περισσότερες από τις φυσικές ζημιές (90%) παρατηρήθηκαν στην επιφανειακή επίστρωση των αντιστάσεων. Οι επιφανειακές ηλεκτρικές εκκενώσεις θα μπορούσε να είναι ο κύριος λόγος για αυτόν τον τύπο ζημιών. Η διηλεκτρική συμπεριφορά της επιφανειακής επίστρωσης της μεταβλητής αντίστασης και του συστήματος του ηλεκτροδίου επαφής, καθώς και οι κατασκευαστικές ατέλειες της επιφανειακής επίστρωσης της μεταβλητής αντίστασης θα μπορούσαν να έχουν σημαντική επίδραση στην χωρητικότητα αντοχής. Έχει παρατηρηθεί ότι ηλεκτρικές εκκενώσεις μπορούν να εμφανιστούν και οι μεταβλητές αντιστάσεις μπορούν να υποστούν φυσική ζημιά πριν αυτό φτάσει στην τάση επιβολής αποτυχημένης λειτουργίας. Συνεπώς καταλήγουμε στο συμπέρασμα ότι η τάση επιβολής αποτυχημένης λειτουργίας δεν θα εμφανιστεί κατά την διάρκεια του περιβάλλοντος επαναληπτικού κρουστικού ρεύματος. Τέλος, στόχος του 8ου κεφαλαίου είναι να παρουσιάσει πρακτικές διαδικασίες μετριασμού και βελτιώσεις εφαρμοσμένες σε σύστημα αντικεραυνικής προστασίας (Σ.Α.Π.) ενός ευαίσθητου εξοπλισμού, ο οποίος αποτελείται από κινητές και σταθερές κάμερες ασφαλείας εγκατεστημένες σε υποσταθμό με πίνακες σταθμών ισχύος. Αυτοί είναι κατασκευασμένοι σε μια γεωγραφική περιοχή μεγάλης πρόσπτωσης κεραυνών και σε μια περιοχή με έδαφος μεγάλης ειδικής αντίστασης. Διαδικασίες και εφαρμογές που αφορούν την θεμελίωση και την γείωση των καμερών ασφαλείας θα εξεταστούν, το ίδιο καλά όπως και η εγκατάσταση των αλεξικέραυνων της γραμμής ισχύος. / The subject of this project is the lightning protection for electrical/electronic equipments with low voltage devices. But before being reported ways and protection devices or given some examples of applications for electrical installations in some countries, should be an introductory reference around the core of this work: the lightning. Thus, chapter 1 contains a description of some import concepts about lightning. Starting from the charge of the clouds and how it is, we arrive at the different types of lightning. Here the simulation in the laboratory with some major gaps evacuation for some of the conclusions of the lightning discharges. Then analyze the mechanism of atmospheric discharges through three phases: entry drain, phase of the return drain and the connecting drain. Finally an analysis and modeling of lightning current and his parameters became. Malfunctions on power units frequently occur due to lightning surge currents induced on ac mains lines of access network equipment installed at outdoor locations. The reasons for malfunctions are that the lightning surge current unnecessarily trips a circuit breaker of a power unit. In chapter 2, to clarify the mechanisms of the malfunctions, we have measured the lightning surge current on ac mains lines of access network equipment. The measured waveforms of the lightning surge current were much longer than those of combination waves defined by K.44 of ITU-T, and the occurrence probability of surge current on ac mains lines was 20 times higher than that on telecommunication lines. When lightning strikes a building, a part of it’s diverted to ground via the external lightning protection system and the grounding system, and another part flows through the electrical wirings of a building, which protected by surge protective devices (SPD). In chapter 3, became a numerical electromagnetic analysis on lightning current distribution inside of directly stricken building, by the electromagnetic model and a simple circuit model of the wirings. According to calculated portion of lightning current and for different wiring systems, concluded that the portion of the lightning current into the wiring on the top and on the bottom floors are the largest, and they converge on constant values at a tall building. Those into wirings on the middle floors are negligibly small. This result is useful in determining energy ratings of SPD. We often hear about damages at electrical/electronic equipment caused by a lightning current although the distance between the lightning stroke and the electronic device is often several hundred meters. In chapter 4, we investigate the portion of lightning current that flows from the stricken building to the next buildings via the supply lines. In chapter 5, we investigate the overvoltage hazard resulting from lightning strikes to the LPS and the partial currents entering the internal installations connected with bonding bar and earth termination system. We calculated the lightning current at the incoming lines of the building for different injection points of lightning current, in order to select the co-ordination of SPD sets, of low-voltage protected device. Also, we calculated the measurements of lightning current distribution and voltage drops in different points and elements of two-stages of SPD sets of different types (switching and limiting) and producers. In chapter 6, we investigate the development of ZnO disks with high energy withstand capability for low voltage surge protected devices. We accomplish that by some modifications of chemical composition, by optimization of manufacturing process and by electrode design of those disks. Varistors are one of the most commonly used protective components in the low voltage systems. It is very important to detect and replace the deteriorated varistors to avoid any damages to the protected system. In chapter 7, we investigate the behavior of low voltage varistors due to repetitive current impulses with the rate of 10 sec to 60 sec. Detailed analysis was done to have the clear idea about the changes of varistor characteristic under repetitive current impulse environment. Most of the physical damages (90%) observed are at the surface coating of the varistors. Surface flashovers could be the main reason for this type of damages. Dielectric behavior of the varistor surface coating and the electrode contact system, and manufacturing defects of the varistor surface coating could be a major influence on withstand capability under the repetitive impulses. It was observed that the surface flashovers may occur and varistors may physically damage before it reach to the clamping voltage failure mode. Therefore it can conclude that the clamping voltage failure mode will not occur during the repetitive impulse environment. Finally, the goal of chapter 8 is to present practical mitigation procedures and improvements applied to the lightning protection system of sensitive equipment, which is composed of moving and stationary security cameras installed in power substation switchyards. They were built in a geographic area of large incidents of lightning strokes and in a region with a high resistivity soil. Practical procedures concerning the grounding and earthing of security cameras are discussed, as well as the installation of power line surge arresters.
2

[en] METROLOGICAL TRACEABILITY OF ELECTRICAL CURRENT IMPULSES IN BRAZIL / [pt] RASTREABILIDADE METROLÓGICA DE IMPULSOS DE CORRENTE ELÉTRICA NO BRASIL

LUCAS CASTRO FARIA 12 March 2019 (has links)
[pt] O para-raios é o principal equipamento de proteção dos transformadores e linhas de transmissão de energia, que estão presentes em todo território nacional, protegendo-os de descargas atmosféricas e sobretensão, evitando grandes perdas de equipamentos e um custo relativamente alto para as concessionárias de energia. O para-raios precisa obter conformidade e certificação em relação à qualidade do material e a suas características de proteção, e um dos ensaios de verificação de desempenho baseia-se na resposta ao impulso de corrente. Contudo, para a realização destes ensaios de desempenho é necessário que haja um sistema de medição acreditado, apto a realizá-los com precisão e rastreabilidade aos padrões de transdutores, ou seja, com níveis de incerteza dentro dos limites aceitáveis, segundo a norma IEC 62475:2010. O Inmetro, que é o Instituto Nacional de Metrologia do Brasil, ainda não possui um Sistema de Medição de Referência (SMR) que possa ser empregado na fiscalização e acreditação de laboratórios que venham a exercer a função de Sistema de Medição Aprovado (SMA), levando a rastreabilidade e conformidade aos padrões de transdutores de corrente elétrica, de modo a produzir equipamentos com confiabilidade e segurança. Assim, essa dissertação faz um levantamento dos níveis de rastreabilidade e um estudo normativo e estrutural de ensaios de impulso de corrente, à luz da norma IEC 62475:2010. / [en] The surge arrester is the main protection equipment of the power transformers and power transmission lines, which are present throughout the country, protecting them from lightnings and overvoltage, avoiding large equipment failures and a relatively high cost for the power companies. The arrester must obtain conformity and certification regarding the quality of the material and its safety features, and one of the performance verification tests is based on the response to current impulses. However, to realize these performance tests it is necessary to have a measurement system accredited to perform this type of test, with accuracy and traceability of the standard transducers, that is, uncertainty levels within acceptable limits according to IEC 62475:2010. The Brazilian National Institute of Metrology ( INMETRO) does not have a Reference Measuring System (RMS) that can be used in the inspection and accreditation of laboratories that will perform as a Approved Measuring System, giving traceability and conformity to the electrical current transducers standards (Shunts or CTs), so as to produce reliable and safe equipments. Thus, this dissertation surveys the traceability levels and the normative and structural landscape regadring current impulse tests based on IEC 62475:2010.
3

Análise de sistemas de aterramento com hastes concretadas submetidos a correntes impulsivas.

BEZERRA, Gabriel Vidal Negreiros. 25 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-25T17:58:53Z No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) / Made available in DSpace on 2018-04-25T17:58:53Z (GMT). No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) Previous issue date: 2017-03-30 / CNPq / Neste trabalho é realizada uma avaliação da resposta impulsiva de aterramento com haste concretada, considerando o efeito da ionização do solo. Para isso, o aterramento foi representado e simulado utilizando uma ferramenta computacional de simulação em três dimensões por meio do método dos elementos finitos. A representação computacional, bem como a validação da mesma, foi feita tomando-se como base dados experimentais apresentados na literatura. O fenômeno da ionização do solo foi implementado ponto a ponto, utilizando o equacionamento do modelo dinâmico de ionização do solo, possibilitando que aterramentos com diferentes formatos geométricos sejam avaliados. Avaliou-se a impedância transitória de uma haste concretada padronizada para solos com diferentes resistividades. Além disso, procedeu-se com uma análise da resposta impulsiva da haste concretada para diferentes parâmetros geométricos, a saber: raio do concreto envolvente, comprimento vertical da haste concretada, comprimento vertical do concreto envolvente e profundidade da haste concretada em relação ao nível do solo. Por fim, propõem-se limites práticos e sugestões de dimensões para a haste concretada, de forma que a reposta impulsiva seja otimizada. / In this research, was performed an impulsive response evaluation of concrete encased groundings, considering de soil ionization effect. In order to achive this, the grouding was represented and simulated in three dimensions using a finite element method software. The computational representation and validation were performed using experimental data presented in the literature. The soil ionization effect was implemented in a point form, allowing evaluate groudings with different geometric formats. It was studied the transient impedance of a standard concrete encased rod placed in soils with different resistivity values. Furthermore, was performed a transient response analysis for different geometric parameters of the concrete encased rod, namely: the concrete radius, the vertical length of the concrete encased rod, the vertical length of the concrete encased rod, the surrounding concrete and the depth of the concrete encased rod in relation to the soil surface. Finally, practical limits and suggested dimensions for the concrete encased rod are proposed, in order to optimize the impulse response.
4

Diagnostika vysokonapěťových kondenzátorů pro kaskádní napěťový násobič / Diagnosis of high voltage capacitors for cascade voltage multiplier

Baev, Dmitriy January 2017 (has links)
The main subject of the final thesis is to find a suitable method for measuring the partial discharge (PD) in the dielectric of high-voltage capacitor. In the theoretical part of my thesis contains from the mechanisms of origin and the harmful effects of partial discharge at high voltage insulation of capacitor. It describes the global galvanic method of partial discharge measurement, the principle of cascade voltage multiplier, its main components are high-voltage capacitor and diode, facilities quality measurement of capacitors for voltage multipliers, advantages and disadvantages and principles of HIPOTRONICS DDX-8003 with the pulse discrimination system. In the experimental part of the diploma thesis is familiar with the diagnostics of high – voltage capacitors by means of laboratory measurements on the electronic bridge and with the help of partial discharge measurement system. Design of suitable electrode arrangement is described which eliminates the influence of corona which makes it impossible to measure partial discharges and the dissipation factor (tg ). Analysis data from measurement and determination of quality level, eventual degradation of measured capacitors. The result of this project should be designed the methodology for finding of poor – quality capacitors in order to increase the reliability of the voltage multiplier.
5

Diagnostika vysokonapěťových kondenzátorů pro kaskádní napěťový násobič / Diagnosis of high voltage capacitors for cascade voltage multiplier

Baev, Dmitriy January 2017 (has links)
The main subject of the final thesis is to find a suitable method for measuring the partial discharge (PD) in the dielectric of high-voltage capacitor. In the theoretical part of thesis contains from the mechanisms of origin and the harmful effects of partial discharge at high voltage insulation of capacitor. It describes the global galvanic method of partial discharge measurement, the principle of cascade voltage multiplier, its main components (high-voltage capacitor and diode). Nowadays are presented the possibilities of measuring the quality of capacitors for voltage multipliers. In the experimental part of the diploma thesis is familiar with the diagnostics of high – voltage capacitors by means of laboratory measurements on the electronic bridge and with the help of partial discharge measurement system. It describes the design of a suitable electrode arrangement that eliminates the influence of the corona, which makes it impossible to measure partial discharges and the dissipation factor tg . The thesis analyzes the obtained data from measurements and determines the quality level or the degradation of the measured capacitors. The result of the project should be designed the methodology for finding poor quality capacitors in order to increase the reliability of the voltage multiplier.