Spelling suggestions: "subject:"curtoscircuitos"" "subject:"curtocircuitos""
1 |
Desenvolvimento de um software para curto-circuitos em transformadores de potênciaGonçalves, Gabriel do Fundo January 2009 (has links)
Estágio realizado na EFACEC Energia - PT e orientado pelo Eng.º Duarte Couto / Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Energia). Faculdade de Engenharia. Universidade do Porto. 2009
|
2 |
Desenvolvimento de uma ferramenta para projecto de quadros eléctricos de baixa tensãoFernandes, Carlos Gustavo Teixeira Paiva January 2009 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major em Energia). Faculdade de Engenharia. Universidade do Porto. 2009
|
3 |
Desenvolvimento de uma ferramenta de apoio ao projecto de instalações electricas BTPereira, André Quintino Alves January 2011 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores. Energia. Faculdade de Engenharia. Universidade do Porto. 2010
|
4 |
Análise da operação de sistemas elétricos com centrais eólicas durante curto-circuitosLuiz Alves Ferreira, Silvio January 2007 (has links)
Made available in DSpace on 2014-06-12T17:42:14Z (GMT). No. of bitstreams: 1
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2007 / Com a crescente aplicação de centrais eólicas para produção de energia elétrica, seja por
motivos ecológicos ou de outras ordens, a influência dessas fontes de geração sobre o
comportamento do sistema de potência tem se tornado cada vez mais significativa. Por
esta razão, os procedimentos de rede de diversos países foram revisados de modo a incluir
critérios específicos para a conexão de centrais eólicas à rede. Dentre esses critérios, destacase
a exigência de que as novas centrais eólicas devem ter capacidade de se manterem
conectadas durante afundamentos momentâneos de tensão, geralmente causados por curtocircuitos.
Dessa maneira, esta dissertação apresenta uma comparação entre os procedimentos
de rede brasileiro e de alguns países com tradição em energia eólica. Além disso, é realizada
uma avaliação dos principais efeitos de curto-circuitos na rede elétrica sobre a capacidade de
centrais eólicas se manterem em operação, com o objetivo de melhorar o desempenho da rede
elétrica durante e após a falta. Para as análises de desempenho, as ferramentas de simulação
ANATEM e ATP foram usadas, com a modelagem de turbinas eólicas com as tecnologias do
tipo gerador de indução conectado diretamente à rede e gerador síncrono conectado à rede
através de conversor de freqüência. Como resultado, essa dissertação contribui para uma
melhor avaliação do comportamento das turbinas eólicas, permitindo a identificação dos
principais fatores que levam as turbinas conectadas à rede com conversores de freqüência
plenos a ter melhor desempenho quanto à operação durante curto-circuitos prolongados
|
5 |
Proposta de Algoritmos Inteligentes para Localizar Faltas e Monitorar a Qualidade da Energia em Redes de Distribuição de Energia ElétricaBíscaro, André do Amaral Penteado [UNESP] 25 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:51Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-04-25Bitstream added on 2014-06-13T21:01:24Z : No. of bitstreams: 1
biscaro_aap_dr_ilha.pdf: 3362347 bytes, checksum: 291075977b505bee42d5b968b8f631c6 (MD5) / Neste trabalho apresenta-se uma metodologia para a localização e diagnóstico automático de faltas em alimentadores de distribuição de energia elétrica através do uso combinado de técnicas de análise de redes, processamento de sinais e sistemas inteligentes. Foram desenvolvidos algoritmos capazes de detectar, classificar e localizar no tempo e espaço, os eventos de qualidade de energia. O procedimento contínuo de detecção de distúrbios é realizado através de análises estatísticas diretas e multinível dos sinais de correntes no domínio wavelet, registrados na subestação. As principais características, ou índices comportamentais, dos sinais das correntes e tensões são extraídas empregando-se a transformada wavelet discreta, a análise multirresolução e o conceito de energia do sinal. Estes índices correspondem aos vetores de entrada de um conjunto de redes neurais ARTMAP Fuzzy independentes, que tem por finalidade estimar o tipo de falta e quais eventos de qualidade de energia estão presentes no sinal amostrado. Os padrões de entrada destas redes são compostos pela energia dos coeficientes dos quatro primeiros níveis de detalhes e aproximações dos sinais de tensão e corrente e, na saída dessas redes, como resposta, tem-se o código do tipo de distúrbio e as fases envolvidas no problema. A localização do distúrbio é realizada após o processo de classificação, sendo que a técnica de localização de faltas proposta aplica-se a alimentadores trifásicos radiais ou fracamente malhados, com cargas desequilibradas, ramais laterais trifásicos, bifásicos ou monofásicos e que possam apresentar geração distribuída. O sistema de diagnóstico e localização de faltas proposto neste trabalho é capaz de auxiliar as concessionárias de energia em sua rotina de trabalho, fornecendo informações importantes para... / This work presents a methodology for automatic diagnosis and fault location on electric power distribution systems through the combined use of modern techniques of network analysis, signal processing and, intelligent systems. Some algorithms were developed aiming to detect, classify and locate in time and space the power quality disturbances. The continuous process of detecting these disturbances is accomplished through statistical analysis and direct current multilevel signal analysis in wavelet domain, recorded in the substation. The main characteristics, or behavioral indices, of the current and voltage signals are extracted employing the discrete wavelet transform, multiresolution analysis and the concept of signal energy. These indexes correspond to the input vectors of a number of independent Fuzzy ARTMAP neural networks, which aim to estimate the fault type and the power quality events that are present in the sampled signal. The input patterns of these networks are composed by energy coefficients of the first four levels of details and approximations of current and voltage signals and, the output network presents the disorder type code and the phases involved in the problem. The fault location is performed after the classification process, and the proposed technique applies to three-phase radial or weakly meshed feeders with unbalanced loads, lateral extensions triphasic, biphasic or, monophasic and presenting distributed generation. The system diagnosis and fault location proposed in this paper are able to assist the utilities in their daily works, providing important information for the operation and maintenance of power distribution systems, minimizing the repairing time and, consequently, obtaining less financial losses due to rapid fault diagnosis and restoration of the normal system operation. A real life three-phase... (Complete abstract click electronic access below)
|
6 |
Proposta de Algoritmos Inteligentes para Localizar Faltas e Monitorar a Qualidade da Energia em Redes de Distribuição de Energia Elétrica /Bíscaro, André do Amaral Penteado. January 2013 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Rubén Augusto Romero Lázaro / Banca: Anna Diva Plasencia Lotufo / Banca: Rogério Andrade Flauzino / Banca: Edgar Manuel Carreño Franco / Resumo: Neste trabalho apresenta-se uma metodologia para a localização e diagnóstico automático de faltas em alimentadores de distribuição de energia elétrica através do uso combinado de técnicas de análise de redes, processamento de sinais e sistemas inteligentes. Foram desenvolvidos algoritmos capazes de detectar, classificar e localizar no tempo e espaço, os eventos de qualidade de energia. O procedimento contínuo de detecção de distúrbios é realizado através de análises estatísticas diretas e multinível dos sinais de correntes no domínio wavelet, registrados na subestação. As principais características, ou índices comportamentais, dos sinais das correntes e tensões são extraídas empregando-se a transformada wavelet discreta, a análise multirresolução e o conceito de energia do sinal. Estes índices correspondem aos vetores de entrada de um conjunto de redes neurais ARTMAP Fuzzy independentes, que tem por finalidade estimar o tipo de falta e quais eventos de qualidade de energia estão presentes no sinal amostrado. Os padrões de entrada destas redes são compostos pela energia dos coeficientes dos quatro primeiros níveis de detalhes e aproximações dos sinais de tensão e corrente e, na saída dessas redes, como resposta, tem-se o código do tipo de distúrbio e as fases envolvidas no problema. A localização do distúrbio é realizada após o processo de classificação, sendo que a técnica de localização de faltas proposta aplica-se a alimentadores trifásicos radiais ou fracamente malhados, com cargas desequilibradas, ramais laterais trifásicos, bifásicos ou monofásicos e que possam apresentar geração distribuída. O sistema de diagnóstico e localização de faltas proposto neste trabalho é capaz de auxiliar as concessionárias de energia em sua rotina de trabalho, fornecendo informações importantes para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work presents a methodology for automatic diagnosis and fault location on electric power distribution systems through the combined use of modern techniques of network analysis, signal processing and, intelligent systems. Some algorithms were developed aiming to detect, classify and locate in time and space the power quality disturbances. The continuous process of detecting these disturbances is accomplished through statistical analysis and direct current multilevel signal analysis in wavelet domain, recorded in the substation. The main characteristics, or behavioral indices, of the current and voltage signals are extracted employing the discrete wavelet transform, multiresolution analysis and the concept of signal energy. These indexes correspond to the input vectors of a number of independent Fuzzy ARTMAP neural networks, which aim to estimate the fault type and the power quality events that are present in the sampled signal. The input patterns of these networks are composed by energy coefficients of the first four levels of details and approximations of current and voltage signals and, the output network presents the disorder type code and the phases involved in the problem. The fault location is performed after the classification process, and the proposed technique applies to three-phase radial or weakly meshed feeders with unbalanced loads, lateral extensions triphasic, biphasic or, monophasic and presenting distributed generation. The system diagnosis and fault location proposed in this paper are able to assist the utilities in their daily works, providing important information for the operation and maintenance of power distribution systems, minimizing the repairing time and, consequently, obtaining less financial losses due to rapid fault diagnosis and restoration of the normal system operation. A real life three-phase... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.0344 seconds