• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação da técnica de decomposição de Benders para cálculo da reserva girante considerando a curva de capabilidade dos geradores

Aleixo, Marcelo de Souza 29 June 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-11-06T17:02:42Z No. of bitstreams: 1 marcelodesouzaaleixo.pdf: 2786878 bytes, checksum: dfbd57d9b8be2153917fe637209df9f0 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-11-23T13:19:16Z (GMT) No. of bitstreams: 1 marcelodesouzaaleixo.pdf: 2786878 bytes, checksum: dfbd57d9b8be2153917fe637209df9f0 (MD5) / Made available in DSpace on 2018-11-23T13:19:16Z (GMT). No. of bitstreams: 1 marcelodesouzaaleixo.pdf: 2786878 bytes, checksum: dfbd57d9b8be2153917fe637209df9f0 (MD5) Previous issue date: 2018-06-29 / Este trabalho apresenta uma metodologia para cálculo da reserva girante do sistema elétrico de potência. A proposta inclui a curva de capabilidade dos geradores bem como cenários de carga e de geração eólica bem como falhas no sistema de geração e transmissão. O fluxo de potência ótimo é utilizado para determinar as condições iniciais do sistema, caso base. A partir daí o problema é resolvido de forma interativa entre dois estágios em umaestruturamestreeescravo: Oproblemamestreutilizaprogramaçãolinearinteirapara determinar o número mínimo de unidades de geração disponíveis (ligadas); O problema escravo verifica se o número de unidades ligadas é suficiente para operação do sistema. Este problema corresponde ao Fluxo de Potência Ótimo com o objetivo de obter o mínimo corte de carga para cada condição operativa. O corte de Benders é produzido para cada cenário, altenativamente, será investigado a utilização da média dos cortes de Benders. O processo termina quando não ocorrer corte de carga. A metodologia é testada utilizando um sistema teste de 4 barras como exemplo tutorial e também aplicada nos sistemas IEEE 14, 39 e 118 barras. / This work presents a methodology for calculating the spinning reserve of the electric power system. The proposal includes the capability curve of the generators as well as errors of prediction of load, wind generation, failures in the system of generation and transmission. The optimal power flow is used to determine the initial conditions of the system, base case. From this point the problem is solved interactively between two stages in a master and slave structure: The first uses integer linear programming to determine the minimum number of available (turn on) generation units; The second corresponds to the Optimum Power Flow with the purpose of obtaining the minimum load shedding for each operative condition. The cut of Benders is produced for each scenario, alternatively, the use of the average of cuts will be investigated. The process ends when there is no load shedding. The methodology is tested using a 4-bar test system as a tutorial example and also applied in IEEE systems 14, 39 and 118 bars.
2

[en] ECONOMIC VALUE OF REACTIVE POWER DEVICES / [pt] MAPEAMENTO DO VALOR ECONÔMICO DOS EQUIPAMENTOS DE COMPENSAÇÃO DE POTÊNCIA REATIVA

IVO SERGIO BARAN 13 December 2002 (has links)
[pt] No novo modelo para o setor elétrico brasileiro a operação do sistema é de responsabilidade do Operador Independente do Sistema enquanto que a propriedade do equipamento e os gastos com a sua manutenção são de responsabilidade do agente prestador do serviço ancilar.Desta forma, o lucro do agente prestador do serviço ancilar de potência reativa será função do custo deste serviço uma vez que a sua remuneração é previamente definida pelo agente regulador. Dentro desta ótica os riscos operacionais dos equipamentos de compensação de potência reativa, se não forem convenientemente mitigados,poderão aumentar os gastos com a manutenção e o pagamento de multa pela indisponibilidade do equipamento.Riscos operacionais são situações de sistema que estão fora da responsabilidade do agente mas que poderão reduzir o seu faturamento.Esta dissertação descreve os riscos operacionais e faz algumas sugestões para proteger o agente da redução do seu faturamento. / [en] In the new brazilian deregulated electrical network, system operation is under Independent System Operator responsibility while the ancillary service agent is the owner of the reactive power equipment and, as a consequence, is responsible for its maintenance costs. In the new model, the profit of the agent is a function of the maintenance costs because his payment is previously defined by the authorities. The operational risks of the reactive power equipments, if not conveniently mitigated, may increase the maintenance frequency and may also result in the payment of a fee due to the equipment unavailability.Operational risks are events in the electrical transmission system that are not under the responsibility of the agent but may reduce his profits. This report describes these operational risks and makes some suggestions to protect the agent against the reduction in his profits.

Page generated in 0.0642 seconds