• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • 1
  • Tagged with
  • 12
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Implantation et validation d’un modèle Monte Carlo du Cyberknife dans un outil de calcul de dose clinique

Zerouali Boukhal, Karim 12 1900 (has links)
Le travail de modélisation a été réalisé à travers EGSnrc, un logiciel développé par le Conseil National de Recherche Canada. / Le Cyberknife (Accuray, Sunnyvale, CA) est un appareil de radiochirurgie stéréotaxique sans cadre. Il a été développé pour administrer de fortes doses dans des volumes restreints. Aussi, pour obtenir une conformation optimale de traitement, des champs circulaires de petites dimensions sont utilisés (\phi = 0,5 à 6 cm). L'étude dosimétrique de ces petits champs doit être menée selon de nouveaux standards puisque ceux-ci échappent aux définitions du TG-51. L'objectif de ce projet est d'implanter une plateforme de calcul de dose de type Monte Carlo pour le CyberKnife en clinique. Il s'articule autour de deux réalisations principales. Tout d'abord, une caractérisation dosimétrique du modèle Monte Carlo de l'accélérateur linéaire du CyberKnife a été menée à travers des simulations Monte Carlo générées par le moteur de EGSnrc. Cette étude est basée sur la caractérisation de la réponse d'un détecteur à un champ de type CK à partir de simulations EGS_chamber. Cette approche permet de prendre en compte l'impact du détecteur sur les mesures expérimentales. Cet aspect est d'autant plus important que le modèle Monte Carlo de l'accélérateur est validé à partir de mesures expérimentales. Les résultats obtenus montrent une bonne concordance, <1% ou 1 mm, entre les mesures expérimentales et les données de simulations pour les grands champs. Pour les champs de diamètre < 12,5 mm, le modèle est moins exact et une correction est appliquée pour atteindre une différence de <1% ou 1 mm. Deuxièmement, ce modèle validé du CK a été implanté dans un cadre de calcul Monte Carlo complet. Une plateforme de calcul dédiée aux calculs Monte Carlo, WebTPS, a été adaptée aux calculs de dose CK. Cette plateforme reçoit les données relatives au plan de traitement et lance des calcul EGSnrc sur un superordinateur. Cette approche tend à réduire les approximations lors de l'évaluation dosimétrique de plans de traitements cliniques. Une incertitude inférieure à 1% peut être atteinte en deux heures de calcul. Ce projet a donc pour objectif de développer une référence clinique pour le calcul de dose dans le cadre de la radiochirurgie stéréotaxique. L'outil WebTPS pourrait être particulièrement utile en clinique, l'algorithme de calcul de dose du CK étant limité dans plusieurs situations de traitement. / Purpose: The scope of this study is to implement a clinical Monte Carlo dose calculation system based on the EGSnrc engine. This web-based tool will be mostly used to evaluate clinical treatment plans in highly heterogeneous phantoms. Methods: The Monte Carlo calculation tool is based on the DOSXYZnrc user code. The platform automatically converts CyberKnife clinical plan to the user code input files. Phantoms can be created from HU to ED curves or by manually assigning material using medical contours. Parallel computation is made on a Compute Canada high-performance cluster to reduce simulation time. A Monte Carlo CyberKnife model is built on BEAMnrc user code using the manufacturer specifications. Simulated and experimental data is compared to estimate the electron beam parameters. The beam energy estimation is based on percent depth dose (PDD) comparison while the full width at half max (FWHM) is validated by output factor (OF) and off-axis ratio (OAR). An EGS_chamber model of the PTW60012 diode is used in the OF calculation. A set of phase-spaces is generated from the optimal model and for each collimator to calculate dose contribution from each incident beam. Results: The linac model optimisation yielded a 0.5% PDD agreement between experimental and simulation data, and a 0.5% or 1 mm for OAR. DOSxyz simulation of full treatment plan, based on the preliminary CyberKnife model, were achieved. Total Monte Carlo dose calculation have been achieved for heterogeneous phantoms. Uncertainty under 1% can be achieved for less than 2 hour of computing time. However, computing time estimation is nontrivial due to its dependence on cluster availability. Conclusion: This work aims to develop a suitable tool for reference plan dose calculation. This web-based tool would be used in several clinical and research applications where the CyberKnife embedded ray-tracing algorithm would show significant limitations. Because it is destined to a clinical use, the whole dose calculation system will be rigorously validated.
12

Traitement du cancer pulmonaire non à petites cellules par radiothérapie stéréotaxique d’ablation

Mathieu, Dominique 03 1900 (has links)
Les néoplasies pulmonaires demeurent la première cause de décès par cancer au Québec représentant près de 6000 décès par année. Au cours des dernières années, la radiothérapie stéréotaxique d’ablation (SABR) s’est imposée comme un traitement alternatif à la résection anatomique pour les patients inopérables atteints d’un cancer pulmonaire non à petites cellules de stade précoce. Il s’agit d’une modalité de traitement qui permet d’administrer des doses élevées, typiquement 30-60 Gy en 1-8 fractions, dans le but de cibler précisément le volume de traitement tout en épargnant les tissus sains. Le Centre Hospitalier de l’Université de Montréal s’est muni en 2009 d’un appareil de SABR de fine pointe, le CyberKnife™ (CK), un accélérateur linéaire produisant un faisceau de photons de 6 MV dirigé par un bras robotisé, permettant d’administrer des traitements non-coplanaires avec une précision infra-millimétrique. Ce mémoire est dédié à la caractérisation de certains enjeux cliniques et physiques associés au traitement par CK. Il s’articule autour de deux articles scientifiques revus par les pairs. D’une part, une étude prospective clinique présentant les avantages de la SABR pulmonaire, une technique qui offre un excellent contrôle tumoral à long terme et aide au maintien de la qualité de vie et de la fonction pulmonaire. D’autre part, une étude de physique médicale illustrant les limites de l’acquisition d’images tomodensitométriques en auto-rétention respiratoire lors de la planification de traitement par CK. / Lung neoplasia remains the leading cause of cancer death accounting for nearly 6,000 deaths per year in Quebec. In recent years, stereotactic ablative radiotherapy (SABR) has emerged as an alternative treatment to anatomical resection for inoperable patients suffering from early stage non-small cell lung cancer. This technique can deliver highly focused doses such as 30-60 Gy in 1-8 fractions in order to target precisely the treatment volume while sparing healthy tissue. In 2009, the Centre Hospitalier de l’Université de Montréal acquired a robotic SABR apparatus, the CyberKnife™ (CK), a linear accelerator mounted on a moving arm producing non-coplanar photon beams of 6 MV with millimetric precision. This thesis presents two scientific peer reviewed articles adressing some clinical and physical challenges with CK. On one hand, a clinical prospective study reporting the advantages of lung SABR, a technic that offers excellent long-term tumor control and helps maintain the quality of life and lung function. On the other hand, a medical physics study exposing the limits of computed tomography scan acquisition in breath-holding for CK treatment planning.

Page generated in 0.0176 seconds