• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Détection des courts-circuits inter-spires dans les Générateurs Synchrones à Aimants Permanents : Méthodes basées modèles et filtre de Kalman étendu - Application à un canal de génération électrique en aéronautique

Aubert, Brice 31 March 2014 (has links) (PDF)
La mise en place d'un nouveau canal d'alimentation électrique incorporant un générateur à aimants permanents PMG (Permanent Magnet Generator) en remplacement de l'actuel canal de génération hydraulique est l'un des sujets de recherche en cours dans le secteur aéronautique. Le choix de cette solution est motivé par de nombreux avantages : réduction de masse, meilleure disponibilité du réseau hydraulique et maintenance plus aisée. Cependant, l'utilisation d'un PMG en tant que générateur électrique au sein d'un avion implique de nouvelles problématiques, notamment en ce qui concerne la sûreté de fonctionnement lors de défaillances internes au PMG. En effet, tant que le rotor est en rotation, la présence d'une excitation permanente due aux aimants entretient la présence du défaut même si le stator n'est plus alimenté, ce qui complexifie la mise en sécurité du PMG. Il est ainsi nécessaire de connaître précisément l'état de santé du PMG afin d'assurer une bonne continuité de service en évitant d'ordonner la mise en sécurité du PMG sur des défaillances externes au générateur. C'est pourquoi les travaux de cette thèse portent sur la détection des courts-circuits inter-spires dans les PMG, ces défauts ayant été identifiés comme les plus critiques pour ce type de machine. Compte tenu du contexte aéronautique, il a été choisi de travailler sur les méthodes de détection basées sur l'estimation de paramètres via un modèle mathématique de la machine en utilisant le Filtre de Kalman Etendu (FKE). En effet, s'il est correctement paramétré, le FKE permet d'obtenir une bonne dynamique de détection et s'avère être très robuste aux variations du réseau électrique (vitesse, déséquilibre, ...), critère important pour garantir un canal de génération fiable. Deux types de modèle mathématique sont présentés pour la construction d'un indicateur de défaut utilisant les estimations fournies par le FKE. Le premier est basé sur une représentation saine du PMG où l'indicateur de défaut est construit à partir de l'estimation de certains paramètres de la machine (résistance, inductance, constante de fem ou pulsation électrique). Le second modèle utilise une formulation d'un PMG défaillant qui permet d'estimer le pourcentage de spires en court-circuit. Après avoir comparé et validé expérimentalement le comportement des différents indicateurs sur un banc de test à puissance réduite, la mise en place d'un indicateur de court-circuit inter-spires au sein d'un réseau électrique aéronautique et son interaction avec les protections existantes sur avion sont étudiées dans la dernière partie de ce mémoire.
2

Contribution à l'étude des machines synchrones à aimants permanents en présence de défauts inter-spires : modélisation, détection de défauts inter-spires / Contribution to the Study of Permanent Magnet Synchronous Machines Under Inter-turn Faults Conditions : Modelling, Inter-turn Fault Detection

Leboeuf, Nicolas 11 December 2012 (has links)
Les systèmes électriques embarqués dans l'aéronautique doivent satisfaire à des cahiers des charges de plus en plus exigeants portant sur le poids, les performances et la fiabilité, d'où l'utilisation des Machines Synchrones à Aimants Permanents (MSAP). Vu les contraintes imposées, les prototypes sont parfois assez éloignés d'une MSAP classique. La surveillance en ligne de ces systèmes est alors plus délicate mais représente un enjeu considérable vu l'aspect critique des applications (ailerons d'avion, freinage...) et a pour objectif d'éviter un incident majeur en le détectant puis en basculant sur un système identique redondé. Ce document propose un travail de modélisation de MSAP saine et en présence de défaut inter-spires ayant pour objectif de définir des méthodes de détections de défauts inter-spires en ligne, sans capteurs supplémentaires. Deux approches sont présentées pour modéliser les MSAP en présence de défauts inter-spires et sont comparées à des essais expérimentaux réalisés sur un prototype aéronautique. L'une d'entre elles, reposant sur une approche par Réseaux De Perméances (RDP), permet d'obtenir le meilleur compromis. La partie suivante propose de tester deux approches utilisant un indicateur de défaut basé sur un modèle d'Onduleur-MSAP sain et montre l'intérêt de ce type d'approche comparé à des approches plus classiques. L'ensemble des indicateurs développés est ensuite analysé à l'aide d'un outil utilisant la Reconnaissance de Formes (RDF) / Embedded electric systems in aircraft applications have to satisfy to specifications including weight, performances and reliability leading to the use of Permanent Magnet Synchronous Machines (PMSM). Due to these constraints, prototypes are often different from classical PMSM. Online monitoring of these systems is challenging but is still important regarding safety applications (electro mechanical airfoil, braking?). The main aim is to detect major incidents in order to use redundant systems. This work concerns modeling of PMSM under both healthy and inter-turn fault cases in order to defined online fault detection methods without additional sensors. Two approaches are presented and compared to experimental tests concerning PMSM under inter-turn fault conditions. One of them is based on Permeance Network (PN) modelling. It can be considered to be the best compromise. The next part deals with two fault indicators methods based on healthy models of Inverter and PMSM and shows improvements brought by these approaches compared to classical methods. The whole indicators are analyzed using Pattern Recognition (PR)
3

Détection des courts-circuits inter-spires dans les Générateurs Synchrones à Aimants Permanents : Méthodes basées modèles et filtre de Kalman étendu / Inter-turn Short-circuit detection on Permanent Magnet Synchronous Machines : Model based method with Extended Kalman Filter

Aubert, Brice 31 March 2014 (has links)
La mise en place d’un nouveau canal d’alimentation électrique incorporant un générateur à aimants permanents PMG (Permanent Magnet Generator) en remplacement de l’actuel canal de génération hydraulique est l’un des sujets de recherche en cours dans le secteur aéronautique. Le choix de cette solution est motivé par de nombreux avantages : réduction de masse, meilleure disponibilité du réseau hydraulique et maintenance plus aisée. Cependant, l’utilisation d’un PMG en tant que générateur électrique au sein d’un avion implique de nouvelles problématiques, notamment en ce qui concerne la sûreté de fonctionnement lors de défaillances internes au PMG. En effet, tant que le rotor est en rotation, la présence d’une excitation permanente due aux aimants entretient la présence du défaut même si le stator n’est plus alimenté, ce qui complexifie la mise en sécurité du PMG. Il est ainsi nécessaire de connaître précisément l’état de santé du PMG afin d’assurer une bonne continuité de service en évitant d’ordonner la mise en sécurité du PMG sur des défaillances externes au générateur. C’est pourquoi les travaux de cette thèse portent sur la détection des courts-circuits inter-spires dans les PMG, ces défauts ayant été identifiés comme les plus critiques pour ce type de machine. Compte tenu du contexte aéronautique, il a été choisi de travailler sur les méthodes de détection basées sur l’estimation de paramètres via un modèle mathématique de la machine en utilisant le Filtre de Kalman Etendu (FKE). En effet, s’il est correctement paramétré, le FKE permet d’obtenir une bonne dynamique de détection et s’avère être très robuste aux variations du réseau électrique (vitesse, déséquilibre, …), critère important pour garantir un canal de génération fiable. Deux types de modèle mathématique sont présentés pour la construction d’un indicateur de défaut utilisant les estimations fournies par le FKE. Le premier est basé sur une représentation saine du PMG où l’indicateur de défaut est construit à partir de l’estimation de certains paramètres de la machine (résistance, inductance, constante de fem ou pulsation électrique). Le second modèle utilise une formulation d’un PMG défaillant qui permet d’estimer le pourcentage de spires en court-circuit. Après avoir comparé et validé expérimentalement le comportement des différents indicateurs sur un banc de test à puissance réduite, la mise en place d’un indicateur de court-circuit inter-spires au sein d’un réseau électrique aéronautique et son interaction avec les protections existantes sur avion sont étudiées dans la dernière partie de ce mémoire. / The establishment of an electrical power supply channel including a Permanent Magnet Generator (PMG) to replace an hydraulic power channel is one of the current topics of research in the aeronautic field. This choice is motivated by several benefits : weight reduction, improvement of the hydraulic network avaibility and easier maintenance. However, the use of PMG as an electrical generator in an aircraft implies new issues, particularly as regards safety considerations when an internal fault occurs in the PMG. Indeed, as long as the rotor in rotating, the presence of the persistent excitation due to the magnets maintains the internal fault even if the stator is de-energized. This makes the safety procedure of PMG more complex. Therefore, it is necessary to precisely know the behavior of the PMG (healthy or faulty) to ensure the avaibility of this power supply channel in order to avoid triggering PMG safety procedure when an external fault occurs. Thus, this work deals with the on-line detection of inter-turn short-circuits in PMG, these faults have been identified as the most critical for this kind of machine Given the aeronautic context, it has been decided to work on detection methods based on parameter estimation via a mathematical model of the machine using the Extended Kalman Filter (EKF). Indeed, with an appropriate setting, the EKF provides a fast dynamic detection and can be very robust to variations in the electrical network (speed, unbalanced, ...) which is an important characteristic to ensure a reliable generation channel. Two types of mathematical model are presented for fault indicator construction using the estimations provided by the EKF. The first one is based on an healthy representation of the PMG where the fault indicator is built from the estimation of PMG electrical parameters (resistance, inductance, electromotive force constant or electrical rotational velocity). The second model uses a faulty PMG formulation to estimate the ratio of short-circuited turns. After the comparison and the experimental validation of the fault indicators behavior on a test bench at reduced power, the establishment of a inter-turn short-circuit indicator within an aircraft electrical system and its interaction with existing protections are studied in the last part of this thesis.

Page generated in 0.1219 seconds