1 |
Solar cells on hydro power plants : A feasibility studyLenner, Johan January 2015 (has links)
Parts of the auxiliary power systems at Fortum's hydro power stations are usingdirect current, which is fed from the generators at the plant and converted byrectifiers. As photovoltaic solar cells produce direct current there are severalhypothetical advantages to use solar power for the auxiliary power supply, e.g.enabling more of the power from the generator to be sold to the grid. It eliminatesthe need of an inverter, conversion losses are avoided and less load is put on therectifiers. However the exclusion of an inverter also prevents the solar cells to have adirect connection to the grid, which in turn makes them ineligible for the Swedishgovernmental solar power investment support program. The lesser load on therectifiers will not affect their lifetime according to manufacturers and thus achieves noeconomic gain. Avoiding conversion losses will increase the gain from the producedelectricity by enabling even more power to be sold to the grid. The economic gainfrom avoiding conversion losses is however too small to gain any feasibility in a smallsolar power installation at a hydro power plant, as the small size will make itexpensive in terms of investment per Wp.
|
2 |
Adaptive Phase Locked Loops for VSC connected to weak ac systemsBabu Narayanan, Mita 13 April 2015 (has links)
The performance of the High voltage dc systems is dependent on the stiffness of the ac bus, it is connected to. With the traditional synchronous reference frame-phase locked loops (SRF-PLL), voltage source converters (VSC) systems with large PLL gains, connected to weak ac networks are shown to be prone to instabilities, when subject to disturbances.
In this thesis a new Adaptive PLL is designed with a pre-filter topology which extracts the fundamental positive sequence component of the input voltage, to be fed into the SRF-PLL for tracking of its phase angle. Compared with other traditional PLL topologies, this Adaptive PLL shows superior immunity to voltage distortions, and also has a faster dynamic performance.
The thesis presents a comparative analysis of the performance of the traditional SRF-PLL with the Adaptive PLL in a VSC control system, and its impact on stability for VSCs connected to weak ac systems (up to SCR=1.3).
|
3 |
En komparativ studie av tillgängligheten hos likströmssystem utifrån deras uppbyggnad.Holmberg, Elias January 2022 (has links)
Den här rapporten undersöker tillgängligheten hos fyra olika likströmssystem vid ett svenskt kärnkraftverk. Detta görs genom att analysera underhållsdokumentation och annan dokumentation från anläggningen samt därifrån beräkna mått för funktionssäkerhet och underhållsmässighet. Dessa mått används i sin tur för att få fram ett mått på driftsäkerheten vilket kvantifieras i ett nyckeltal. Rapporten kommer inte till någon konkret slutsats kring vilket av systemen som i praktiken faktiskt är bäst lämpat för att fungera som förebild för framtida likströmssystem. I stället rekommenderas ytterligare studier av två av systemen. I rapporten framkommer det att två av systemen relativt sett är mer utsatta för handhavandefel, det bör göras ytterligare studier för att vidimera den slutsatsen och för att kunna slå fast sambandet med säkerhet. Det slås fast att den vanligaste komponenten som felar är likriktarna i likströmssystemen. / This report examines the availability of four different DC-systems at a Swedish nuclear powerplant. This is done by analyzing maintenance documentation and other documentation from the facility. This documentation is then used to calculate a measure of operational reliability, which is quantified in a key performance indicator. The report does not come to any absolute conclusion about which of the systems is in practice best suited to serve as a model for future DC-systems. Instead, further studies of two of the systems are recommended. The findings in this communicated in this report is that two of the systems are more likely to suffer from handling errors. More research is needed and this should also be investigated further in order to be able to say with certainty that this is the case. The component that fails the most in these systems is the rectifiers.
|
4 |
On the design of hybrid DC-breakers consisting of a mechanical switch and semiconductor devicesMagnusson, Jesper January 2015 (has links)
The interest of using direct current in networks for both transmission and distribution of power is increasing due to the higher efficiency compared to the alternating current used today. As no natural zero crossings exist in direct current, the interruption of fault currents becomes a challenge. Several circuit breaker topologies have been proposed to fulfill the requirements for DC grids. One such topology is the hybrid DC-breaker consisting of three parallel branches: a mechanical switch, a semiconductor branch, and a metal oxide varistor. The current interruption in the hybrid DC-breaker is made in three steps. A mechanical switch carries the nominal current with low losses during normal operation. When the breaker is tripped to interrupt the current, the mechanical switch is opened and commutates the current into the semiconductor branch. This branch will then conduct the current as the mechanical switch regains its voltage withstand. The semiconductors turn off and force the current into the varistor branch where the magnetic energy is absorbed and the current is forced to zero. This thesis is based on simulations and experiments to obtain design rules for such a DC-breaker. It has been shown that several aspects needs to be considered. Simulations are performed with several different models to obtain the requirements of each of the components in the DC-breaker. First of all, the choice of the semiconductor is important. There are a number of components available in the market, but typically they are optimized for fast switching applications like inverters rather than circuit breaker applications that only requires one single switching. Due to the high current and voltage ratings and the easy control, the IGBT seems to be the best choice among the commercially available components. Simulations on the mechanical switch show that there is an optimal combination of opening time and arc voltage of the to obtain a successful commutation into the semiconductor branch. The actuator is a key component since a relatively low increase in performance of the actuator drive circuit, significantly decreases the requirement of the other components in the DC-breaker. A significant part of the work has been put on the voltage transient during the turn-off of the semiconductor. As the current is forced into the varistor branch, the stray inductance in that loop will result in an over-voltage due to the high current derivative. A new type of snubber has been investigated using another varistor mounted close to the semiconductor. It has been shown that the function of the varistor snubber can be divided into two regions depending on the ratio between the snubber and the main varistor. If the ratio is high enough, the energy absorbed in the snubber varistor is only a few percent of the total energy. / Intresset för att använda likström i både transmission och distribution av elkraft har ökat tack vare en högre verkningsgrad och lägre förluster. En begränsande faktor för utbyggnad av likströmsnät är utvecklingen av brytare för likström. Svårigheten att bryta en likström jämfört med växelström är att det saknas en naturlig nollgenomgång där strömmen kan brytas. För att tvinga fram en nollgenomgång kan man använda en hybrid brytare som består av tre parallella grenar: en mekanisk switch, en gren med krafthalvledarkomponenter och en gren med en varistor. Hybridbrytaren bryter en ström i tre steg. I normalfallet leder den mekaniska kontakten strömmen för att hålla nere de elektriska förlusterna. När strömmen ska brytas öppnas den mekaniska kontakten och strömmen kommuteras över till krafthalvledargrenen. När krafthalvledaren stängs av, trycks strömmen över till den tredje grenen där varistorn begränsar spänningen över brytaren och absorberar den magnetiska energi som finns lagrad i nätet. Strömmen avtar och när systemet är avmagnetiserat når strömmen noll. Denna avhandling sammanfattar ett arbete att med hjälp av simuleringar och experiment få fram designparametrar för en sådan brytare. Flera simuleringsmodeller har av använts för att få fram designkriterier för de olika komponenterna i hybridbrytaren. Ett första steg är att välja krafthalvledarkomponent. Dessa komponenter är främst utvecklade för omvandling mellan lik- och växelström där de slås av och på i korta intervall. En brytartillämpning skiljer sig markant från detta eftersom strömmen bara behöver brytas enstaka gånger vilket ändrar kraven på komponenten. Enkelheten i att kontrollera komponenten tillsammans med dess höga ström- och spänningstålighet gör IGBTn till det bästa valet bland de kommersiellt tillgängliga komponenterna. Simuleringar visar att en optimal design av den mekaniska switchen är en kombination av snabbhet och ljusbågsspänning. En nyckelkomponent är den snabba aktuatorn som driver switchen. En relativt liten förbättring av drivkretsen kan leda till minskade krav och därmed kostnader på övriga komponenter i brytaren. En stor del av arbetet har lagts på att studera den transienta överspänningen då krafthalvledarkomponenten bryter strömmen. Den höga strömderivatan medför att även små ströinduktanser leder till relativt stora överspänningar som riskerar att skada brytaren. En ny typ av snubberkrets, bestående av en mindre varistor som monteras nära krafthalvledaren, har föreslagits. På detta sätt separeras överspänningsskyddet från absorptionen av den magnetiska energin. Experiment och simuleringar visar att om spänningsförhållandet mellan de två varistorerna är tillräckligt stort absorberas endast ett par procent av energin i snubbern. / <p>QC 20150420</p>
|
Page generated in 0.0199 seconds