• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 27
  • 27
  • 22
  • 16
  • 14
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise de riscos toxicológicos e ambientais na exposição ocupacional aos resíduos de armas de fogo (GSR/ firing ranges): uma proposta de normalização / Analysis of toxicological and environmental risks of occupational exposure to residues of firearms (GSR/ firing ranges): A proposal for mormalization

ROCHA, ERNESTO D. 03 February 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-02-03T12:11:19Z No. of bitstreams: 0 / Made available in DSpace on 2016-02-03T12:11:19Z (GMT). No. of bitstreams: 0 / Diariamente milhares de profissionais da área de segurança utilizam armas de fogo, quer em ações de combate a criminalidade; quer em treinamentos obrigatórios que a atividade exige. Apesar disso a quantidade de informação sobre os riscos à saúde desses profissionais devido da exposição aos resíduos de disparos, especialmente quando são usadas armas de grosso calibre, ainda é escassa. Este trabalho pretendeu trazer uma contribuição às discussões sobre o tema com uma proposta de normalização para ser observada no planejamento dos procedimentos de treinamento e atividades desses profissionais. Para tanto foram estudados dois grupos de profissionais: o primeiro, profissionais militares da Polícia Militar do Estado de São Paulo durante intensas jornadas de treinamento com esforço físico e grande numero de disparos com armas de fogo de grosso calibre O segundo grupo envolvendo peritos criminais do núcleo de balística do Instituto de Criminalística da Secretaria de Segurança do Estado de São Paulo. Foram utilizadas amostras de materiais biológicos (sangue, urina e saliva) e amostras do ar dos ambientes fechados onde estas rotinas de trabalho ocorrem. No caso dos profissionais militares, os níveis dos metais monitorados no ar variaram de acordo com o tipo de arma e munição utilizada, sendo ultrapassado o limite de tolerância estabelecido na NR-15 (100 μg/m3) após o uso de espingarda (216 μg/m3). A média e desvio padrão dos níveis de chumbo no sangue antes (3,3 μg/dL ± 0,7) e depois (18,2 μg/dL ± 5,1) do curso indicam que ouve um aumento importante num curto período de tempo, também houve aumento nos níveis de chumbo e antimônio na urina. No segundo caso de exposição ocupacional aos resíduos de disparo no núcleo dos peritos balísticos se verificou uma baixa quantidade de resíduos no ambiente de trabalho, se comparado com o Limite de Tolerância preconizado na norma NR-15, e uma baixa quantidade de chumbo no sangue (3,9 μg/dL ± 0,8) se comparado com o Índice Biológico Maximo Permitido IBMP (60 μg/dL) estabelecido na NR-7, sem embargo quando comparado o grupo de balísticos com o grupo controle (1,8 μg/dL ± 0,7) estabeleceu se uma diferença. O estudo dos cenários de exposição permitiu gerar uma proposta para trabalho seguro nestes ambientes e recomendações para o desenho e uso de estantes fechados de disparo. Os câmbios que se introduzam nos costumes e comportamentos dos profissionais levaram uma diminuição do risco associado ao uso de armas de fogo nestes estantes. As conclusões do presente trabalho contribuem para a adequação das medidas de proteção dos trabalhadores de segurança, e na adequação da legislação relativa aos limites de tolerância e índices bilógicos empregados no controle de saúde ocupacional. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
12

Medidas do primeiro coeficiente de Townsend de ionização em misturas gasosas utilizadas em microdosimetria / Measurements of the first Townsend ionization coefficient in gaseous mixtures employed in microdosimetry

PETRI, ANNA R. 01 November 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-11-01T17:22:23Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-01T17:22:24Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Microdosímetros gasosos geralmente empregam uma mistura gasosa equivalente ao tecido humano mole (Tissue-equivalent Gas TEG), composta de um hidrocarboneto, dióxido de carbono e nitrogênio, de forma que o poder de freamento na mistura e no tecido sejam semelhantes. Entretanto, independentemente do hidrocarboneto adotado, dados tanto teóricos como experimentais do primeiro coeficiente de Townsend de ionização (α) nestas misturas são raros, ainda que a primeira TEG, cujo metano é o gás majoritário, tenha sido proposta em 1956 por Rossi e Failla e continue sendo amplamente utilizada. Neste trabalho, dados do parâmetro α em TEGs baseadas no metano (CH4 64,4%, CO2 32,4% e N2 3,2%) e nos isômeros do butano (C4H10 51,4%, CO2 42,3% e N2 6,3%) são apresentados pela primeira vez em geometria planar para a faixa de campo elétrico normalizado pela densidade do gás (E/N) entre 100 290 Td (1 Td = 10-21 V.m2). O método de medidas adotado baseia-se na técnica de Townsend pulsada, onde o primeiro coeficiente de Townsend pode ser determinando comparando a corrente elétrica no regime de avalanche e a corrente de ionização primária gerada pela incidência de um feixe de laser de nitrogênio em um eletrodo metálico (catodo) de uma câmara de geometria planar, sendo o anodo um eletrodo de alta resistividade (ρ=2×1010Ω.m). O aparato experimental, até então operado apenas em pressão atmosférica, foi modificado para também trabalhar em baixa pressão (120 hPa), de modo a aumentar a faixa de E/N investigada. A validação do método e das alterações do sistema de detecção foi realizada utilizando os três gases componentes das TEGs cujos parâmetros de transporte são amplamente estudados: o nitrogênio, o dióxido de carbono e o metano. Observou-se que o parâmetro na TEG com metano assemelha-se com os valores determinados para o metano puro. Na TEG baseada no isobutano, ele é compatível com o primeiro coeficiente de Townsend do dióxido de carbono para campos acima de 170 Td. Já o parâmetro na mistura com n-butano é intermediário entre os valores obtidos para o dióxido de carbono e o nitrogênio. Os resultados experimentais, disponíveis em forma tabular, foram comparados com os simulados utilizando o programa Magboltz 2, evidenciando boa concordância dentro da incerteza experimental. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP / FAPESP: 02/04697-1; 07/50591-4; 09/51809-9
13

Risco de exposição à radiação ionizante em crianças e adolescentes participantes de um programa de controle da asma em comparação à população geral / Exposure risk to ionizing radiation in children and adolescents participating in an asthma control program compared to the general population

LIMA, LETÍCIA G.C. de S. 31 January 2018 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2018-01-31T16:47:23Z No. of bitstreams: 0 / Made available in DSpace on 2018-01-31T16:47:23Z (GMT). No. of bitstreams: 0 / Asma é uma doença de elevada prevalência e morbidade, constituindo-se um importante problema de saúde pública em todo o mundo. Muitos diagnósticos médicos por imagem dependem da utilização de raio X; entretanto, no caso da asma, o diagnóstico é clínico, particularmente na criança. Os pacientes são frequentemente submetidos a procedimentos radiológicos, preferencialmente o raio X de tórax. A escassez de dados na literatura referentes aos riscos da exposição à radiação ionizante em pacientes com asma e os possíveis benefícios relacionados à oportunidade de coleta de informações justificaram a investigação no programa municipal infantil de controle da asma de Ipatinga, Minas Gerais (Programa Respirar). Foi realizado estudo retrospectivo referente ao ano de 2014, com caso controle, do qual participaram 363 pacientes do Programa Respirar e número semelhante de controle, sem diferença sociodemográfica significativa entre os grupos. Encontramos que uma criança do grupo respirar tem 1,59 vez mais chance de realizar um raio X, e para o raio X de tórax essa chance aumenta para 6,56 vezes. A maioria dos raios X de tórax foi solicitada nas visitas aos serviços de urgência, mas 90% dos raios X realizados e laudados no grupo respirar e 84,2% do grupo controle revelaram resultado normal ou com alterações típicas, possibilitando o questionamento a respeito da indicação do exame. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
14

Avaliacao da radioatividade natural em areias das praias da Grande Vitoria, Espirito Santo / Assessment of natural radiation of beachs sands in Great Vitoria, Espirito Santo

AQUINO, REGINALDO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:15Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
15

Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios X gerados no intervalo de 50 kV subp a 125 kV subp

NOGUEIRA, MARIA do S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:03Z (GMT). No. of bitstreams: 1 04674.pdf: 2960498 bytes, checksum: 31da12ce5904c3db2729e9982663d7fe (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
16

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

OLIVEIRA, CAMILA T. de 08 April 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-04-08T12:56:51Z No. of bitstreams: 0 / Made available in DSpace on 2016-04-08T12:56:51Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
17

Avaliacao da radioatividade natural em areias das praias da Grande Vitoria, Espirito Santo / Assessment of natural radiation of beachs sands in Great Vitoria, Espirito Santo

AQUINO, REGINALDO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:15Z (GMT). No. of bitstreams: 0 / Neste trabalho foram determinadas as concentrações dos radionuclídeos naturais 226Ra, 232Th e 40K em amostras de areias superficiais para 16 localizações ao longo da costa da Grande Vitória, região metropolitana do estado do Espírito Santo, sudeste do Brasil. As áreas de estudo compreendem as praias de Manguinhos e Jacaraípe no município da Serra, Camburi, Praia do Canto e Curva da Jurema no município de Vitória, Praia da Costa e Praia de Itapuã no município de Vila Velha, Praia de Setibão, Setibinha, Praia do Morro, Praia das Castanheiras e Praia da Areia Preta no Município de Guarapari e areia da Reserva Paulo Cesar Vinha também localizada no município de Guarapari. Para cada sítio de estudo, três amostras foram seladas em frascos de 100 ml de polietileno de alta densidade. Após espera de aproximadamente 4 semanas para atingir o equilíbrio secular das séries do 238U e 232Th, as amostras foram medidas por espectrometria gama de alta resolução e o espectro analisado com o software WinnerGamma. A correção da auto-absorção foi realizada para todas as amostras. A concentração do 226Ra foi determinada pela média ponderada das concentrações do 214Pb e 214Bi, a concentração de 232Th pela média ponderada das concentrações dos 228Ac, 212Pb e 212Bi e a concentração de 40K pela sua transição única de 1460 keV. O equivalente em rádio e o índice gama foram obtidos a partir das concentrações de 226Ra, 232Th e 40K. As concentrações de 226Ra variaram de 3 ± 1Bq.kg-1 a 738 ± 38Bq.kg-1, com o maior valor na localidade central da Praia de Camburi. As concentrações de 232Th variaram de 7 ± 3Bq.kg-1 a 7422 ± 526Bq.kg-1, com o maior valor na Praia da Areia Preta. As concentrações de 40K variaram de 14 ± 6Bq.kg-1 a 638 ± 232Bq.kg-1, com o maior valor na Praia da Areia Preta. O cálculo do equivalente em rádio e do índice gama mostrou duas faixas distintas. Na primeira, para a maioria das praias, o equivalente em rádio variou de 15 ± 6Bq.kg-1 a 257 ± 18Bq.kg-1, abaixo do limite inferior de 370Bq.kg-1 recomendado pela OECD como adequado para uso em material de construção e o índice gama externo foi inferior ao limite aceitável de 1 sugerido pelo UNSCEAR. Na segunda, para as praias de Setibinha, Curva da Jurema, Camburi Sul e Camburi Central e Praia da Areia Preta, o equivalente em rádio variou de 820 ± 40Bq.kg-1 até 11200 ± 580Bq.kg-1, excedendo de 2 a 30 vezes o limite mínimo recomendado para aplicação na construção civil e o índice gama superou de 3 até quase 40 vezes o limite sugerido pelo UNSCEAR. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
18

Desenvolvimento de um sistema de referencia para determinacao do equivalente de dose pessoal e da constancia de feixes de radiacao X

VIVOLO, VITOR 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:52Z (GMT). No. of bitstreams: 0 / Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10). / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
19

Determinacao dos fatores de conversao de kerma no ar e de fluencia para o equivalente de dose ambiental para raios X gerados no intervalo de 50 kV subp a 125 kV subp

NOGUEIRA, MARIA do S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:03Z (GMT). No. of bitstreams: 1 04674.pdf: 2960498 bytes, checksum: 31da12ce5904c3db2729e9982663d7fe (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
20

Análise compartimental e aspectos dosimétricos aplicados ao colesterol marcado com sup(3)H / Compartimental analysis and dosimetric aspects applied to cholesterol with sup(3)H labeled

OLIVEIRA, ADRIANO dos S. 03 February 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-02-03T11:46:20Z No. of bitstreams: 0 / Made available in DSpace on 2016-02-03T11:46:20Z (GMT). No. of bitstreams: 0 / Doenças cardiovasculares (DCVs) são uma das maiores causas de morte ao redor do mundo, de acordo com a Organização Mundial da Saúde (OMS). Sabe-se que, alterações do nível das lipoproteínas plasmáticas, que são responsáveis pelo transporte do colesterol pela corrente sanguínea, estão relacionadas com o desenvolvimento de doenças cardiovasculares. Por essa razão conhecer os parâmetros biocinéticos das lipoproteínas plasmáticas e quantificá-los é importante para corrigir e aprofundar estudos relacionados às doenças associadas a alterações no nível das lipoproteínas. O objetivo principal deste trabalho é fornecer um modelo biocinético e estimar as doses radiométricas para o 3H-Colesterol, um traçador radioativo empregado em estudos fisiológicos e metabólicos. O modelo utilizado neste trabalho foi baseado em [SCHWARTZ e col., 2004] quanto à distribuição do colesterol pelas lipoproteínas e no modelo gastrointestinal do [ICRP 30, 1979]. As doses distribuídas nos compartimentos do modelo e nos órgãos e tecidos de um adulto padrão descritos no [ICRP 106, 2008] foram calculadas utilizando a metodologia MIRD (Medical Internal Radiation Dose) e a análise compartimental realizada pelo programa computacional Matlab®. Os coeficientes de doses foram estimados para um phantom de um homem padrão (73 kg) descrito no [ICRP 60, 1991]. As doses estimadas tanto para o modelo quanto as estimadas para outros órgãos foram baixas e não ultrapassaram a maior dose obtida que foi no intestino grosso superior, como sendo 46,8 μGy. Esses parâmetros poderão ser utilizados como auxilio em trabalhos que necessitem de pareceres dos comitês de ética, quanto ao uso do 3H-Colesterol como traçador radioativo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0245 seconds