• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • Tagged with
  • 115
  • 81
  • 66
  • 38
  • 36
  • 32
  • 26
  • 24
  • 20
  • 20
  • 19
  • 16
  • 16
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Simulação semi-empírica da resposta termoluminescente sob diferentes geometrias de filtro

SHAMMAS, GABRIEL I.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:24Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
22

Dosimetria com materiais radiocromicos em feixes de eletrons acelerados - processos de irradiacao com doses altas

SILVA, ROSEMEIRE E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:35Z (GMT). No. of bitstreams: 1 06888.pdf: 7154898 bytes, checksum: 2cdf88344fc5d54779947540d009d741 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:97/11079-2
23

Avaliacao dosimetrica de detectores semicondutores para aplicacao na dosimetria e microdosimetria de neutrons em reatores nucleares e instalacoes de radiocirurgia / Dosimetric evaluation of semiconductor detectors for application in neutron dosimetry and microdosimetry in nuclear reactor and radio surgical facilities

NAHUEL CARDENAS, JOSE P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:28Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Dosimetria biologica em protecao radiologica. Elaboracao de curvas dose-reposta para o Cosup60 e Cssup137

SILVA, MARCIA A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:39Z (GMT). No. of bitstreams: 1 05407.pdf: 4903042 bytes, checksum: 419915481d530053b3055a4afa7c0e1f (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
25

Estudo e levantamentos de parametros para dosimetria de fontes de Iodo-125 aplicadas em braquiterapia / Study and parameters survey for iodine-125 source dosimetry to be applied in brachytherapy

MOURA, EDUARDO S. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:12Z (GMT). No. of bitstreams: 0 / A utilização da técnica braquiterapia com sementes de iodo-125 para o tratamento do câncer de próstata têm sido utilizada por décadas com bons resultados clínicos. Para atender as necessidades da população brasileira, o IPEN-CNEN/SP desenvolveu o protótipo para as sementes de iodo-125 com tecnologia nacional. Os objetivos deste trabalho são o desenvolvimento e estudo dos processos dosimétricos associados à obtenção experimental dos parâmetros úteis à caracterização das sementes de iodo-125 e avaliar se os procedimentos desenvolvidos, por este trabalho, possuem as condições necessárias para a determinação das análises dosimétricas, fundamentais para o sucesso dos procedimentos clínicos. Os dosímetros escolhidos para as análises são os TLD-100 (LiF:Mg,Ti), inicialmente estes dosímetros foram submetidos por duas etapas de seleção, com o objetivo de escolher os dosímetros mais reprodutíveis para as análises dosimétricas. As duas etapas foram à seleção por medidas de massa e a reprodutibilidade após quatro séries de irradiações por um irradiador de Cobalto-60 (CTR-IPEN). Após estas etapas, os dosímetros foram irradiados em um acelerador linear com energia de 6 MV (Serviço de Radioterapia Hospital Israelita Albert Einstein) para gerar os fatores de calibração individuais para cada dosímetro. Posteriormente, os dosímetros foram utilizados para as irradiações com a semente de iodo-125, modelo 6711 (GE-Healthcare). As irradiações com a semente de iodo-125 e demais análises renderam os valores necessários para a determinação dos parâmetros sugeridos pela AAPM (American Association of Physicists in Medicine): constante de taxa de dose, função de geometria, função de dose radial e função de anisotropia. Os resultados obtidos mostram boa concordância com os valores publicados pela literatura, para o mesmo modelo de semente de iodo-125, ratificando que os parâmetros realizados poderão ser utilizados para a dosimetria e controle de qualidade das sementes de iodo- 125 que irão ser produzidas pelo IPEN-CNEN/SP. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
26

Desenvolvimento e avaliação de um novo porta detector/filtro para monitoramento termoluminescente com CaSOsub(4):Dy/PTFE

CAMPOS, VICENTE de P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:30Z (GMT). No. of bitstreams: 1 11253.pdf: 7162286 bytes, checksum: 8c317086ceb03e1882b7946a3ddefe94 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
27

Dosimetria na regiao de 0.25Mrad a 25Mrad utilizando filmes de triacetato de celulose (CTA)

DAFFERNER, J.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:33Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:54Z (GMT). No. of bitstreams: 1 00358.pdf: 1139096 bytes, checksum: c1b62a118be24d3d34fe640cb74bff0b (MD5) / Dissertacao (Mestrado) / IEA/D / Escola Politecnica, Universidade de Sao Paulo - POLI/USP
28

Desenvolvimento de uma metodologia de calibração e testes de medidores de produto Kerma-Área / Development of a calibration methodology and tests of kerma area product meters

COSTA, NATHALIA A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:54Z (GMT). No. of bitstreams: 0 / A grandeza produto kerma-área (PKA) é importante para estabelecer níveis de referência em exames de radiologia diagnóstica. Essa grandeza pode ser obtida por meio de medidores do PKA. O uso desses medidores é fundamental para avaliar a dose de radiação em procedimentos radiológicos, além de ser um bom indicador para que os limites de dose na pele do paciente não sejam excedidos. Algumas vezes, esses medidores vêm acoplados a equipamentos de radiação X, o que dificulta sua calibração. Neste trabalho foi desenvolvida uma metodologia de calibração de medidores do PKA. O instrumento utilizado para este fim foi o Patient Dose Calibrator (PDC). Ele foi desenvolvido para ser utilizado como referência na verificação da calibração de medidores do PKA e kerma no ar usados na dosimetria de pacientes e para verificação da consistência e do comportamento de sistemas de controle de exposição automáticos. Por se tratar de um equipamento novo, que, no Brasil, ainda não é utilizado como equipamento de referência para calibração, foi realizado, também o controle de qualidade deste equipamento, com testes de caracterização, a calibração e a avaliação da dependência energética. Após os testes, ficou provado que o PDC pode ser utilizado como instrumento de referência para a calibração a ser realizada in situ, de forma que as características de cada equipamento de radiação X onde os medidores do PKA são utilizados sejam consideradas. A calibração foi, então, realizada com medidores do PKA portáteis e em um equipamento de radiologia intervencionista que possui um medidor do PKA acoplado. Os resultados foram bons e ficou provada a necessidade de calibração desses medidores e a importância da calibração in situ com um medidor de referência. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
29

Desenvolvimento de uma nova metodologia para o calculo de dose em dosimetria fotografica

DALTRO, TERESINHA F.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:37:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:16Z (GMT). No. of bitstreams: 1 05383.pdf: 5069239 bytes, checksum: 7eb90d0ab97b4fe286a135fef870f96f (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
30

Dosimetria termoluminescente de neutrons termicos com CaF-2+KBr e CaSO-4:Dy+KBr

LEITE, ANA M.P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:04Z (GMT). No. of bitstreams: 1 00456.pdf: 1075435 bytes, checksum: 5890a1018150d05979ee39919f44ca34 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Energia Atomica - IEA

Page generated in 0.0139 seconds