• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caractérisation de goujons de polymères renforcés de fibres de verre (PRFV) pour les dalles de chaussée jointées

Montaigu, Mathieu January 2010 (has links)
Les joints de chaussées sont mis en oeuvre pour contrôler la fissuration due aux conditions thermiques et environnementales. Par ailleurs, les goujons d?acier sont couramment utilisés au Québec dans la réalisation de dalles de chaussées en béton jointées, appelées communément dalles courtes goujonnées. Ils permettent le transfert des charges dues au trafic entre les dalles au niveau des joints. Il s?avère aujourd?hui que les conditions environnementales rencontrées en Amérique du Nord (et plus particulièrement au Québec) et l?emploi de sels de déglaçage en hiver, favorisent les phénomènes de corrosion et de dégradation au niveau des joints qui sont un élément structural prépondérant vis-à-vis de la durabilité de ces structures de chaussées. Des goujons de polymères renforcés de fibres de verre (PRFV) peuvent être une alternative sans corrosion à ceux d?acier et/ou revêtus d?époxy actuellement mis en oeuvre. Ils permettent une conception de durabilité accrue et à coûts moindres (durée de service allongée, entretiens réduits). Ce projet propose une série d?essais en laboratoire, pour d?une part caractériser les propriétés et le comportement à court et long terme de goujons de PRFV, et d?autre part réaliser des expérimentations structurales sur des spécimens de dalles de chaussées jointées. Un des objectifs est de proposer une méthodologie de design en vue de leur utilisation dans de futurs projets.Les goujons de PRFV qui font l?objet de ces essais sont fabriqués par la compagnie Pultrall Inc. de Thedford Mines (Québec, Canada). Deux types de goujons de PRFV sont étudiés dans le cadre de ce projet de recherche (résine polyester et vinylester) ; couvrant une gamme de sept diamètres allant de 25,4 mm à 44,5 mm.
2

Conception, construction et monitorage d'une dalle de grande dimension en béton armé de polymères renforcés de fibres (PRF)

Beaulieu-Michaud, Marie-Christine January 2013 (has links)
De nos jours, la corrosion des armatures engendre une usure accrue des structures en béton armé suscitant une inquiétude grandissante de la population. Afin d’éliminer ce problème, l’utilisation de barres d’armature en polymères renforcés de fibres (PRF) représentent une solution de substitution des barres d’armature en acier. Le projet de recherche s’effectue dans le cadre de la réfection complète en armatures composites de la dalle du quai de déchargement à l’incinérateur de la ville de Québec. En fait, les matériaux composites sont considérés, car ils constituent une solution alternative à l’acier et sont très avantageux considérant leurs propriétés mécaniques et leur comportement. Cependant, il y a toujours un manque d’informations sur la durabilité de ces types de barres soumises à des charges cycliques dans un environnement agressif. Le projet de recherche vise à étudier le comportement en service sur une toute nouvelle application, soit une dalle d'un quai de déchargement de déchets et l’expérimentation s’est effectuée à l’incinérateur de Québec. L’objectif global du projet est de caractériser le comportement en service (flèche, fissuration, déformation) des PRFV sous des sollicitations environnementales particulières et sous des charges importantes à l’intérieur du bâtiment. L’ouvrage est constitué d’une dalle de béton unidirectionnelle de 200 mm d'épaisseur supportée par des poutres de béton à travées multiples variant approximativement de 6 à 11,5 m. Cette dalle, ayant une surface approximative de 1300 mètres carrés, est conçue conformément à la norme CAN/CSA-S806-02¹ ainsi que la norme CAN/CSA-S6-06². Lors de la construction, des équipements de mesure ont été installés à des endroits stratégiques, ce qui a permis d’effectuer des études paramétriques, plus particulièrement sur la flèche, la fissuration ainsi que sur l’augmentation des contraintes et des déformations. Ces études sont requises étant donné que les critères en service prônent sur les critères de résistance lors de la conception. Afin de caractériser le comportement en service de l’ouvrage, des essais de chargement ont été réalisés, et ce, avec les camions-vidanges. La validation et la comparaison des résultats expérimentaux et théoriques ont permis de déterminer si les normes actuelles surestiment certaines valeurs pour le calcul des états limites de service.
3

Optimisation structurale de dalles de chaussées en béton jointées avec des goujons en matériaux composites en polymères renforcés de fibres de verre (PRFV)

Bricola, Julien January 2012 (has links)
Résumé: Au Québec, la majorité du réseau routier, construit dans les années 1960-1970, montre des signes manifestes de vieillissement. Aussi, l’augmentation du trafic routier et les conditions climatiques rigoureuses, rendent difficile l’entretien et l’exploitation des chaussées routières dans ce territoire nord-américain. Effectivement, ces conditions environnementales engendrent des dégâts importants pour les chaussées routières, principalement en hiver. L’emploi de sels de déglaçage pour lutter contre le gel accentue les facteurs de dégradation des routes surtout pour les chaussées rigides jointées en béton. Les phénomènes de détérioration se manifestent notamment par la corrosion des aciers au niveau des joints qui sont des éléments structuraux garantissant la durabilité des routes. Les chaussées rigides jointées ou « dalles courtes goujonnées » sont encore principalement dimensionnées avec des goujons en acier placés au droit des joints. Un des rôles de ces structures est de contrôler la fissuration due aux conditions thermiques et environnementales. Pour pallier ces désordres, le Ministère des Transports du Québec (MTQ) se tourne vers de nouvelles techniques et des matériaux plus performants afin d'assurer la pérennité des ouvrages. Avec l'évolution rapide des méthodes et des connaissances en matière de conception des chaussées, ainsi qu'avec l'apparition de nouvelles technologies et de nouveaux produits, le ministère met l'accent sur la recherche et le développement. Cela a permis de mettre au point des techniques novatrices et de concevoir diverses technologies au contexte québécois. Justement, un des axes de recherche et de développement se porte sur les matériaux composites qui ont récemment donné de bons résultats dans le domaine du génie civil. C’est pourquoi des goujons en polymères renforcés de fibres de verre (PRFV) apparaissent comme une solution à la corrosion des armatures de liaison en acier. Elles accroissent ainsi une durabilité à moindres coûts : la durée de service est allongée, l’entretien et l’impact sur les personnes et le trafic sont réduits. Ce projet propose une optimisation de dimensionnement structural sur des spécimens de dalles de chaussées jointées, en vue de leur utilisation dans de nouveaux projets.Les goujons de PRFV qui font l’objet de ces essais sont fabriqués par la compagnie Pultrall Inc. de Thetford Mines (Québec, Canada). La résine utilisée pour les PRFV est uniquement une résine vinylester et les goujons ont des diamètres allant de 28,6 mm à 34,9 mm. Enfin, un seul type de sol est utilisé dans le cadre de ce projet ; il s’agit d’un type de sol dont la particularité recherchée est son module de réaction.||Abstract: In Quebec, the majority of the road network was built in the 60's - 70's and show obvious signs of ageing. Moreover, the increase of road traffic and the rigorous weather conditions, render the maintenance and the exploitation of roads in this Northern American part quite difficult. Indeed, these environmental conditions cause severe damages for roads, especially in winter. The degradation factor of the jointed rigid pavement is intensified by the highway salt. So, the phenomena of deteriorations appears mainly by the corrosion of the steel at the joints (structural elements) guaranteeing the durability of roads. The jointed rigid pavements or "short jointed pavements" are still mainly sized with steel dowels placed at the lining of joints. One of the main functions of these structures is to control the formation of cracking due to the thermal and environmental conditions. In order to reduce these , disorders, the Ministry of Transport of Quebec (MTQ) turned towards new techniques and innovative materials to ensure the longevity of roads. With the rapid evolution of specific methods and knowledge in roads design, joined with technologies and new products, the MTQ emphasizes the research and development. That way, advanced techniques and diverse technologies in the Quebecois context are settled. As a matter of fact, one of the axes of these development researches concerns the composite materials which have recently been given good results in the civil engineering area. That is why Glass Fibre-Reinforced Polymer (GFRP) dowels bars appear as a solution to the steel corrosion. In fact, they provide better durability with lower costs: the increase of service life as well as the decrease of maintenance persons and traffics impac. Thus, this project proposes an optimization of structural design of GFRP dowels for transverse jointed highway pavement slabs, also keeping in mind their use in new projects. The GFRP dowels which are given in this essay are made by the Pultrall Inc. Company from Thetford Mines (Quebec, Canada). The resin used for the polymer materials is only vinylester resin and the dowels have diameters going from 28.6 mm to 34.9 mm. Finally, only a stiff base is used for the road, its particularity is the modulus of subgrade reaction.
4

Transfert d'un composé organo-chloré depuis une zone source localisée en zone non saturée d'un aquifère poreux vers l'interface sol-air : expérimentations et modélisations associées

Marzougui, Salsabil 29 January 2013 (has links) (PDF)
Deux expériences ont été menées sur la plate-forme expérimentale "SCERES" afin d'évaluer les concentrations et les flux de vapeurs de TCE dans SCERES en présence de deux dalles de béton fissurées installées, l'une après l'autre, à la surface de SCERES. Cet aquifère poreux est un milieu hétérogène de grande échelle (25 x 12 x 3 m3). Les résultats ont montré que le panache de vapeur de TCE couvre la plupart du bassin au bout de 3 semaines depuis la création de la zone source de TCE dans le sous sol. L'hétérogénéité du site SCERES a engendrée une distribution verticale non uniforme de la concentration de vapeurs de TCE. La simulation du panache de vapeur dans SCERES a été effectuée au moyen du code de calcul multiphasique "SIMUSCOPP". La présence sur SCERES de la dalle de béton, un milieu peu perméable et peu diffusif, a constitué une "barrière" en vue du transfert de vapeurs de TCE vers l'interface dalle/atmosphère. Afin de mieux quantifier le flux de vapeurs à travers la dalle de béton, une étude de coefficient de diffusion et de perméabilité des deux dalles a été réalisée. Un mouvement vertical ascendant du toit de la nappe a généré un fort gradient de pression motrice de l'air du sol. Ceci a engendré une forte augmentation des flux de vapeurs à l'interface sol/atmosphère. La quantification de ces flux de vapeurs a été effectuée à l'aide d'une solution semi analytique basée sur la loi de Fick et la loi de Darcy en tenant compte à la fois de l'effet de gradient de pression motrice et l'effet de densité de vapeurs sur le transfert de vapeurs vers la surface du sol. L'intrusion de vapeurs de TCE dans le bâtiment modèle, installé sur la dalle de béton, a été générée par une mise en dépression dans ce dernier. Ce qui a fait augmenter la concentration de vapeurs de TCE sous la dalle ainsi dans le bâtiment. La simulation de l'intrusion de vapeurs dans l'air intérieur de bâtiment a été réalisée par l'intermédiaire du code de calcul multiphysics "COMSOL", avec lequel nous avons démontré l'évolution de la concentration de vapeurs obtenues expérimentalement dans le bâtiment et qui dépend directement de la variation spatio-temporelle du flux massique à travers la dalle.
5

Transfert d'un composé organo-chloré depuis une zone source localisée en zone non saturée d'un aquifère poreux vers l'interface sol-air : expérimentations et modélisations associées / Transfer of an organo-chlorinated compound from a source area located in the unsaturated zone of a porous aquifer to the soil-air interface : experiments and modelling related

Marzougui Jaafar, Salsabil 29 January 2013 (has links)
Deux expériences ont été menées sur la plate-forme expérimentale "SCERES" afin d'évaluer les concentrations et les flux de vapeurs de TCE dans SCERES en présence de deux dalles de béton fissurées installées, l'une après l'autre, à la surface de SCERES. Cet aquifère poreux est un milieu hétérogène de grande échelle (25 x 12 x 3 m3). Les résultats ont montré que le panache de vapeur de TCE couvre la plupart du bassin au bout de 3 semaines depuis la création de la zone source de TCE dans le sous sol. L'hétérogénéité du site SCERES a engendrée une distribution verticale non uniforme de la concentration de vapeurs de TCE. La simulation du panache de vapeur dans SCERES a été effectuée au moyen du code de calcul multiphasique "SIMUSCOPP". La présence sur SCERES de la dalle de béton, un milieu peu perméable et peu diffusif, a constitué une "barrière" en vue du transfert de vapeurs de TCE vers l'interface dalle/atmosphère. Afin de mieux quantifier le flux de vapeurs à travers la dalle de béton, une étude de coefficient de diffusion et de perméabilité des deux dalles a été réalisée. Un mouvement vertical ascendant du toit de la nappe a généré un fort gradient de pression motrice de l'air du sol. Ceci a engendré une forte augmentation des flux de vapeurs à l'interface sol/atmosphère. La quantification de ces flux de vapeurs a été effectuée à l'aide d'une solution semi analytique basée sur la loi de Fick et la loi de Darcy en tenant compte à la fois de l'effet de gradient de pression motrice et l'effet de densité de vapeurs sur le transfert de vapeurs vers la surface du sol. L'intrusion de vapeurs de TCE dans le bâtiment modèle, installé sur la dalle de béton, a été générée par une mise en dépression dans ce dernier. Ce qui a fait augmenter la concentration de vapeurs de TCE sous la dalle ainsi dans le bâtiment. La simulation de l'intrusion de vapeurs dans l'air intérieur de bâtiment a été réalisée par l'intermédiaire du code de calcul multiphysics "COMSOL", avec lequel nous avons démontré l'évolution de la concentration de vapeurs obtenues expérimentalement dans le bâtiment et qui dépend directement de la variation spatio-temporelle du flux massique à travers la dalle. / Two experiments were conducted on the experimental platform "SCERES" to assess the TCE vapour concentrations and fluxes in SCERES with two concrete slabs installed, one after the other, on the ground surface. This artificial aquifer is a large scale (25 x 12 x 3 m3) heterogeneous porous medium. The results showed that the TCE vapour plume covers most of the basin 3 weeks after the creation of the TCE source area in unsaturated zone. The heterogeneity of SCERES has generated a non uniform vertical distribution of the TCE vapour concentration. Simulation of vapour plume in SCERES was carried out by the multiphase code "SIMUSCOPP".The presence in SCERES of a low permeability and low diffusive medium compared to the sand in the basin,as a concrete slab, constituted a "barrier" for the transfer of TCE vapour to the interface concrete slab / atmosphere. To better quantify the TOE fluxes through the concrete slab, a study of diffusion coefficient and permeability of both concrete slabs was done. An upward vertical movement of the water table has generated a strong soil air pressure driving gradient, which led to a strong increase in the TCE vapour concentrations near the surface which has increased the vapour fluxes at the interface soil / atmosphere. Quantification of vapour fluxes at the interfaces soil / atmosphere and concrete slab / atmosphere was performed using a semi analytical approach based onFick's and Darcy's laws by taking into account both the effect of the driving pressure gradient and the effect of density vapour on the vapour transfer towards the soil surface.The intrusion of TCE vapours into the model building installed on the concrete slab was generated by creating a vacuum. The results showed that, during the TCE vapour suction from the model building, the concentration of TCE vapours under the concrete slab and in the building increases. Simulation of vapour intrusion into indoor air was done by the computational Multiphysics code "COMSOL", allowing simulation of the evolution of the vapour concentration obtained experimentally in the building. Il was shown that they depend directly on the spatial-temporal variation of the mass flux through the slab.

Page generated in 0.0533 seconds