• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • Tagged with
  • 9
  • 9
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Examination of dampness problems of a historic house/

Yardım, Bülent. Tunçoku, Sarp January 2006 (has links) (PDF)
Thesis (Master)--İzmir Institute of Technology, İzmir, 2006. / Keywords: Dampness, humidity, moisture,restoration. Includes bibliographical references (leaves. 66-69).
2

Whole building heat and moisture analysis

Tariku, Fitsum. January 1900 (has links)
Thesis (Ph.D.)--Concordia University (Canada), 2008. / Includes bibliographical references.
3

Dynamic model of the rotary dryer /

Cho, Hyun Sam January 1975 (has links)
No description available.
4

Systèmes d’isolation thermique par l’extérieur : études expérimentales et numériques des transferts de chaleur et d’humidité. / External Thermal Insulation Systems : Experimental and Numerical Studies of Heat and Humidity Transfers

Bendouma, Mathieu 22 February 2018 (has links)
L’isolation thermique par l’extérieure (ITE) constitue une solution technique intéressante pour améliorer les performances énergétiques du secteur du bâtiment. Cependant, l’ITE peut venir modifier l’équilibre hygrothermique de l’enveloppe et affecter sa durabilité, notamment au regard de l’humidité. Dans ce contexte, un premier travail a consisté à étudier en laboratoire le comportement hygrothermique de trois systèmes d’ITE rapportés sur une paroi en parpaing : un système ETICS (PSE sous enduit mis en œuvre par voie humide) et deux systèmes sous bardage (mis en œuvre par voie sèche), dont un incluant des matériaux biosourcés (laine de bois et ouate de cellulose). Des expériences en enceinte biclimatique, combinées à des simulations numériques des transferts couplés de chaleur et de masse, ont permis d’appréhender le comportement hygrothermique de ces parois rénovées à différents stades : lors de la pose des solutions d’ITE, en usage « normal » et dans des conditions conduisant à des risques de condensation. Les résultats du système ETICS montrent le rôle important de la colle et la difficulté à appréhender numériquement son comportement. Les résultats des systèmes sous bardage soulignent l’intérêt d’utiliser des matériaux biosourcés dans des conditions à risques, mais également la sensibilité des simulations numériques aux propriétés hydriques des matériaux hygroscopiques. Un second travail portant sur l’analyse in situ d’un système d’ITE sous bardage a souligné l’absence de risques majeurs liés à l’humidité durant les deux années étudiées. Par ailleurs, la comparaison simulation/expérience a mis en évidence le rôle important joué par la lame d’air ventilée. / External thermal insulation (ETI) is an interesting technical solution for improving the energy performance of the building sector. However, ETI may change the hygrothermal balance of the envelope and affect its durability, especially with regard to moisture. With this in mind, a first work consisted in studying the hygrothermal behavior of three systems of ETI set on a hollow concrete block wall in the laboratory: an ETICS system (wet process) and two systems under cladding (dry process), with one of them composed with bio-based materials (wood wool and cellulose wadding). Experiments in a bi-climatic enclosure, combined with numerical simulations of coupled heat and mass transfers, made it possible to apprehend the hygrothermal behavior of these renovated walls at different stages: during the installation of ETI solutions, in "normal" use and under conditions leading to risks of condensation. The results of the ETICS system show the important role of the glue and the difficulty to understand numerically its behavior. The results of the cladding systems underline the interest of using bio-based materials under hazardous conditions, but also the sensitivity of numerical simulations to the hydric properties of hygroscopic materials. A second study on the in situ analysis of a cladding ETI system highlighted the absence of major risks related to humidity during the two years studied. In addition, the simulation / experiment comparison highlighted the important role played by the ventilated air.
5

Indoor and outdoor environmental assessment of Durban block hostels : an internal evaluations on exposure measures and outcomes of self supported health and well-being in hostels.

Buthelezi, Sikhumbuzo Archibald. January 2007 (has links)
Hostel dwellers form a larger part of the urban population in South Africa (Ramphele, 1999). These hostels were initially created as temporal arrangement for African men moving from rural to urban areas seeking for employment. Due to housing shortage in urban areas they eventually became permanent residential accommodation. However, observations into the environmental conditions in these hostels have raised concerns about the health and well being of residents and neighbouring communities. The area of study was selected on the basis of the current depleted living conditions due to mismanagement of facilities provided by both the occupants and the hostel administrators. The study was a cross sectional descriptive study involving all three Durban Metropolitan block hostels. Assessing (i) the quality of block hostel environment (indoor and outdoor) through visual inspection (walkthrough), (ii) the exposure measures and outcomes (biophysical environment assessment) by means of questionnaire survey, air testing and microbial identification. Sixty three (63) hostel inventory were completed, followed by the administration of 450 questionnaires, and 646 surface and air samples were collected in the indoors of the selected hostel blocks including the control outdoor samples. The demographic profile of the hostel dwellers in the selected hostel blocks revealed that in the five bed type dormitories the habitable space per individual was 3 m 2 to 3.8 m2. Whilst in the ten bed type dormitories the habitable space per individual was 3.3 m 2 to 3.6 m2 . This was not even close to the World Health Organization suggested habitable space of 12 m2 (WHO, 2000) and was therefore regarded as overcrowding. Lack of access control in the hostels exacerbated by the socio-economic demands of the living environments, e.g. unemployment, was to blame for overcrowding. This overcrowding of the hostels was overloading the services, causing enormous number of blockages and bursts of wastewater pipes resulting in the system not functioning. This situation resulted in the accumulation of dampness in the indoor environment, and hence creating conditions favouring the growth of indoor mouldiness in the buildings. This was further supported by evidence that 47% of the occupants in the selected hostel blocks were experiencing respiratory symptoms and 53% experiencing non-respiratory symptoms. The most recorded respiratory symptoms were pulmonary tuberculosis (14.3%), chest tightness (12.2%), sore and dry throat (7%), sinus congestion (7%) symptoms. Whilst the most recorded non-respiratory symptoms were headache (11.5%), dry and itchy skin (11.5%), stomach upset (6.3%) and fatigue (3.6%). Forty five percent (45%) of the respondents were current smokers and 80% of them had a tendency of smoking indoors. The results of the surface and air samples indicated that the level of indoor mould growth in the selected hostel blocks was at 37, 24%. Surface moulds were at 58% and airborne spores were at 42%. Statistical analysis of data revealed a significant relationship between exposure factors and outcomes in the 5, 10 and 15-bed type dormitories. Incidence Risk Rate (IRR) and the p-value (p . 0.01) were used to determine relationships between exposure factors and outcomes. Certain factors were very much supportive in the development of selfreported symptoms in the selected hostel blocks of the three hostels under certain circumstances and these were the hygiene state of the building, leaking pipes, smoking habits and total mea and dg surface moulds. At all levels of the analysis the hygiene state of the building was very much supportive in the development of self-reported symptoms. Other exposure factors were not supportive at all, for example, structural defects, bed-types, different floor levels and participants' perception of overcrowding. A review process of the role of legislation in controlling the adverse health effects revealed that certain aspects of the legislation relating to building standards requirements, sanitation requirements, ventilation requirements, space and density requirements, and air quality standards requirements were violated. Therefore, the findings of the study recommended that a proper management plan must be developed to enhance living standards. This plan shall include a routine maintenance of the building structures, the development of a culture of self-care, as well as access control in the hostels. In addition to that where there are signs of visible moulds on walls and ceilings adequate control measures are highly recommended using commercially available measures in order to provide a healthy living environment. In conclusion is the adoption of a compliance policy towards legal requirements pertaining to building standards as defined in the National Building Regulations Standards Act (Act 103 of 1977). This study has showed that necessary iii steps need to be taken in South Africa in order to combat this problem. Further research need to be taken in order the inhabitable buildings to be better living environment improving the existing building structures. / Thesis (MMed.)-University of KwaZulu-Natal, Durban, 2007.
6

Adsorption of moisture and indoor pollutants on a mixed-adsorbent /

Lee, Song-Yng, January 1997 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1997. / Typescript. Vita. Includes bibliographical references (leaves 115-119). Also available on the Internet.
7

Adsorption of moisture and indoor pollutants on a mixed-adsorbent

Lee, Song-Yng, January 1997 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 1997. / Typescript. Vita. Includes bibliographical references (leaves 115-119). Also available on the Internet.
8

An investigation of unbalanced forced-air heating systems in historic homes and the potential for resultant moisture problems in the building envelope

Brown, Peter M. January 2001 (has links)
Unblanced forced-air heating systems create a situation that may be detrimental to the building envelope. These systems create an air pressure differential, which acts as a moisture transport mechanism, which has the potential to carry moisture, through the smallest of openings in the building envelope. Once this warm air enters the wall cavity it comes into contact with the unheated surfaces of the components making up the building envelope, which are below dew point during the heating months. As this moisture-laden air reaches its dew point, condensation occurs. / Department of Architecture
9

Natural ventilation, dampness and mouldiness in dwellings in the Waterloo housing development (Durban Metropolitan Area) : a case study of indoor air quality.

Gansan, Jaisendra. January 2004 (has links)
Dampness can cause the development of moulds in buildings and pose a threat to the quality of the building structure, indoor air quality and health of the occupants. An emerging source of housing related problems are the building materials commonly used in housing construction, which can influence respiratory health. There is concern regarding the quality of the housing stock in the Durban Metropolitan area with regard to dampness and its the potential impact on the health of occupants. To elucidate this issue, a study was conducted to assess natural ventilation, dampness and mouldiness in dwellings of the Waterloo Housing development (Durban Metropolitan Area), between February 2001 and December 2003. A total of 491 randomly selected homes were visually inspected and residents were surveyed by means of a structured questionnaire. Three hundred and eighteen (318) air and surface mould samples were collected in duplicate, totalling 636 samples and analysed in the laboratory. Building characteristics and physical conditions were recorded and noted. Temperature and relative humidity readings were also taken during the survey. After the analysis of the 491 questionnaires, physical conditions of the dwellings were found to be poor and of concern. With the number (1178) and size of habitable rooms in the dwellings; the occupancy of 2414 people with an average of 2.05 persons per room, indicated overcrowding and congestion. About 51% (n=249) of the dwellings surveyed were found to be experiencing dampness (>3m2) and 47% (n=230) had visible surface moulds, primarily on the walls (at least an average of 1m2) . Predominant airborne fungal organism identified included; Aspergillus (23%-indoors, 26outdoors), Cladosporium (47%- indoors, 51%-outdoors), Penicillum (27%-indoors, 26%-outdoors) spp. Natural ventilation was also inadequate in 261 (53%) dwellings, which did not have airbricks. This inadequacy significantly promotes the occurrence of dampness and surface moulds (p < 0.05). With poor ventilation, dampness and mould growth in the dwellings, there was a high number of cases with upper respiratory tract health complaints; like Cough - 25% (n=122), Sinuses - 25% (n=121), flu symptoms 23% (n=llO) lower respiratory infections such as asthma - 27% (n=130), and chest infections - 23% (n=113). Asthma, wheeze, runny nose and allergy to dust were statistically associated with dampness (p < 0.05), mouldiness (p < 0.03) and lack of ventilation (p < 0.01). Buildings separate their occupants from hostile external environments and create a better internal environment for them, therefore dwellings must be constructed in a manner that promotes the health and well being of the occupants. In terms of guiding regulations, there were several omissions and non-compliance with existing local building bye-laws in the construction of houses, leading to adverse implications. Improved workmanship, appropriate material selection and compliance with the relevant guidelines during planning and construction inter alia, are recommended when addressing housing issues, thereby promoting the interest, health and well-being of the users. / Thesis-(M.Med)- University of KwaZulu-Natal, Durban, 2004.

Page generated in 0.1295 seconds