• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimentos analíticos limpos em sistemas de análises em fluxo para determinação de espécies de interesse ambiental / Development of clean analytical procedures in flow injection analysis for determination of environmentally relevant species

Melchert, Wanessa Roberto 01 April 2005 (has links)
A química limpa tem como principal objetivo o desenvolvimento e a implementação de processos e produtos químicos para reduzir ou eliminar o uso ou a geração de substâncias nocivas à saúde humana e ao meio ambiente. Neste trabalho, foram desenvolvidos procedimentos analíticos limpos para a determinação de nitrato e nitrito em águas naturais e para o tratamento dos resíduos gerados na determinação espectrofotométrica de nitrito e fenóis. Para tanto, foram exploradas as principais estratégias empregadas em química limpa: substituição dos reagentes tóxicos, minimização do consumo dos reagentes e dos resíduos gerados e tratamento desses resíduos. O procedimento analítico limpo para a determinação de nitrato em águas naturais foi baseado em medidas diretas no ultravioleta, após separação de nitrato dos interferentes utilizando um sistema de análises em fluxo com coluna de resina aniônica. O método desenvolvido emprega um único reagente (HClO4) em quantidades mínimas (18 µL/determinação) e permite a determinação de nitrato entre 0,50 e 25,0 mg L-1, sem interferência de ácido húmico, NO2-, PO43-, Cl-, SO42- e ferro(III) nas quantidades usuais em águas naturais. A freqüência de amostragem e o coeficiente de variação (n = 20) foram estimados em 17 determinações h-1 e 0,7%, respectivamente. Os resultados obtidos para amostras de águas de diferentes procedências foram concordantes com o método de referência (redução a nitrito por limalhas de cádmio cobreado seguida por reação de diazo-acoplamento) a nível de confiança de 95%. O tratamento do resíduo gerado na determinação de nitrito, empregando irradiação (UV) na presença do reagente de Fenton (80 mmol/L H2O2 e 1 mmol/L Fe2+), promoveu completa descoloração do resíduo com diminuição de ca. 87% na concentração de carbono orgânico total. A fotodegradação também foi aplicada no tratamento do resíduo gerado na determinação de fenóis totais com 4-aminoantipirina. A degradação ocorreu na presença de H2O2 e irradiação (UV). A completa supressão da absorção de radiação pela 4-aminoantipirina foi observada após 30 min de recirculação da solução no foto-reator, à vazão de 4 mL/min. O procedimento analítico para a determinação de nitrito foi baseado em sistema de análises em fluxo com multicomutação empregando mini-bombas solenóides para o gerenciamento das soluções. O sistema foi acoplado a um foto-reator para a degradação em linha dos resíduos gerados. O método desenvolvido minimiza as quantidades de reagentes (0,6 mg sulfanilamida e 0,03 mg N-naftil-etilenodiamina por determinação) e permite a determinação de nitrito entre 0,10 e 1,00 mg L-1 (r = 0,998) com sensibilidade comparável à alcançada no procedimento com adição contínua de reagentes. O limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e freqüência de amostragem foram estimados em 17 µg L-1, 2,6% e 80 determinações h-1, respectivamente. / Green chemistry has as principal objective the development and implementation of chemical processes and products to minimize or eliminate the use or generation of harmful substances to the human health and the environment. In this work, clean analytical procedures for determination of nitrate and nitrite in natural waters and for the treatment of wastes generated in the spectrophotometric determination of nitrite and phenol were developed. The principal strategies employed in green chemistry were explored to achieve these goals: replacement of the toxic reagents, minimization of reagent consumption and waste generation and waste treatment. The clean analytical procedure for nitrate determination in natural waters was based on the direct spectrophotometric measurement in the ultraviolet, after separation of nitrate from interfering species in a flow-injection system with an anion-exchange resin. The developed method employ only one reagent (HClO4) in minimum amount (18 µL/determination) and can be applied for nitrate determination within 0.50 and 25.0 mg L-1, without interference of humic acid, NO2-, PO43-, Cl-, SO42- and iron(III) in concentrations typically found in natural waters. The sampling rate and the coefficient of variation (n = 20) were estimated as 17 determinations per hour and 0.7%, respectively. Results obtained for natural water samples of different origin were in agreement with the reference method (reduction to nitrite by copperized cadmium filings followed by a diazo-coupling reaction) at the 95% confidence level. The treatment of the waste generated in nitrite determination employing UV irradiation in the presence of Fenton reagent (80 mmol/L H2O2 and 1 mmol/L Fe2+) caused the complete discoloration of the waste and reduced the total organic carbon concentration in 87%. The photodegradation was also applied for the treatment of the waste generated in the determination of total phenols with 4-aminoantipyrine. The degradation occurred in the presence of H2O2 and UV irradiation. Radiation absorption by 4-aminoantipyrine was completely suppressed after 30 min of treatment of solution in the recirculation mode at 4mL/min. The analytical procedure for nitrite determination was based on a flow system with multicommutation employing solenoid micro-pumps for the solution handling. The developed method minimizes the reagent amounts (0.6 mg sulfanilamide and 0.03 mg N-(1-Naphthyl)-ethylene-diamine per determination) and can be applied for nitrite determination within 0.10 and 1.00 mg L-1 (r = 0.998) with sensitivity comparable to the achieved in the procedure with continuous reagent addition. The detection limit (99.7% of confidence), coefficient of variation (n = 20) and sampling rate were estimated as 17 µg L-1, 2.6% and 80 determinations per hour, respectively.
2

Desenvolvimento de procedimentos analíticos limpos em sistemas de análises em fluxo para determinação de espécies de interesse ambiental / Development of clean analytical procedures in flow injection analysis for determination of environmentally relevant species

Wanessa Roberto Melchert 01 April 2005 (has links)
A química limpa tem como principal objetivo o desenvolvimento e a implementação de processos e produtos químicos para reduzir ou eliminar o uso ou a geração de substâncias nocivas à saúde humana e ao meio ambiente. Neste trabalho, foram desenvolvidos procedimentos analíticos limpos para a determinação de nitrato e nitrito em águas naturais e para o tratamento dos resíduos gerados na determinação espectrofotométrica de nitrito e fenóis. Para tanto, foram exploradas as principais estratégias empregadas em química limpa: substituição dos reagentes tóxicos, minimização do consumo dos reagentes e dos resíduos gerados e tratamento desses resíduos. O procedimento analítico limpo para a determinação de nitrato em águas naturais foi baseado em medidas diretas no ultravioleta, após separação de nitrato dos interferentes utilizando um sistema de análises em fluxo com coluna de resina aniônica. O método desenvolvido emprega um único reagente (HClO4) em quantidades mínimas (18 µL/determinação) e permite a determinação de nitrato entre 0,50 e 25,0 mg L-1, sem interferência de ácido húmico, NO2-, PO43-, Cl-, SO42- e ferro(III) nas quantidades usuais em águas naturais. A freqüência de amostragem e o coeficiente de variação (n = 20) foram estimados em 17 determinações h-1 e 0,7%, respectivamente. Os resultados obtidos para amostras de águas de diferentes procedências foram concordantes com o método de referência (redução a nitrito por limalhas de cádmio cobreado seguida por reação de diazo-acoplamento) a nível de confiança de 95%. O tratamento do resíduo gerado na determinação de nitrito, empregando irradiação (UV) na presença do reagente de Fenton (80 mmol/L H2O2 e 1 mmol/L Fe2+), promoveu completa descoloração do resíduo com diminuição de ca. 87% na concentração de carbono orgânico total. A fotodegradação também foi aplicada no tratamento do resíduo gerado na determinação de fenóis totais com 4-aminoantipirina. A degradação ocorreu na presença de H2O2 e irradiação (UV). A completa supressão da absorção de radiação pela 4-aminoantipirina foi observada após 30 min de recirculação da solução no foto-reator, à vazão de 4 mL/min. O procedimento analítico para a determinação de nitrito foi baseado em sistema de análises em fluxo com multicomutação empregando mini-bombas solenóides para o gerenciamento das soluções. O sistema foi acoplado a um foto-reator para a degradação em linha dos resíduos gerados. O método desenvolvido minimiza as quantidades de reagentes (0,6 mg sulfanilamida e 0,03 mg N-naftil-etilenodiamina por determinação) e permite a determinação de nitrito entre 0,10 e 1,00 mg L-1 (r = 0,998) com sensibilidade comparável à alcançada no procedimento com adição contínua de reagentes. O limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e freqüência de amostragem foram estimados em 17 µg L-1, 2,6% e 80 determinações h-1, respectivamente. / Green chemistry has as principal objective the development and implementation of chemical processes and products to minimize or eliminate the use or generation of harmful substances to the human health and the environment. In this work, clean analytical procedures for determination of nitrate and nitrite in natural waters and for the treatment of wastes generated in the spectrophotometric determination of nitrite and phenol were developed. The principal strategies employed in green chemistry were explored to achieve these goals: replacement of the toxic reagents, minimization of reagent consumption and waste generation and waste treatment. The clean analytical procedure for nitrate determination in natural waters was based on the direct spectrophotometric measurement in the ultraviolet, after separation of nitrate from interfering species in a flow-injection system with an anion-exchange resin. The developed method employ only one reagent (HClO4) in minimum amount (18 µL/determination) and can be applied for nitrate determination within 0.50 and 25.0 mg L-1, without interference of humic acid, NO2-, PO43-, Cl-, SO42- and iron(III) in concentrations typically found in natural waters. The sampling rate and the coefficient of variation (n = 20) were estimated as 17 determinations per hour and 0.7%, respectively. Results obtained for natural water samples of different origin were in agreement with the reference method (reduction to nitrite by copperized cadmium filings followed by a diazo-coupling reaction) at the 95% confidence level. The treatment of the waste generated in nitrite determination employing UV irradiation in the presence of Fenton reagent (80 mmol/L H2O2 and 1 mmol/L Fe2+) caused the complete discoloration of the waste and reduced the total organic carbon concentration in 87%. The photodegradation was also applied for the treatment of the waste generated in the determination of total phenols with 4-aminoantipyrine. The degradation occurred in the presence of H2O2 and UV irradiation. Radiation absorption by 4-aminoantipyrine was completely suppressed after 30 min of treatment of solution in the recirculation mode at 4mL/min. The analytical procedure for nitrite determination was based on a flow system with multicommutation employing solenoid micro-pumps for the solution handling. The developed method minimizes the reagent amounts (0.6 mg sulfanilamide and 0.03 mg N-(1-Naphthyl)-ethylene-diamine per determination) and can be applied for nitrite determination within 0.10 and 1.00 mg L-1 (r = 0.998) with sensitivity comparable to the achieved in the procedure with continuous reagent addition. The detection limit (99.7% of confidence), coefficient of variation (n = 20) and sampling rate were estimated as 17 µg L-1, 2.6% and 80 determinations per hour, respectively.
3

Estudo numérico e experimental da geração de biogás a partir da biodegradação de resíduos sólidos urbanos

Firmo, Alessandra Lee Barbosa 02 July 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-10T14:21:50Z No. of bitstreams: 2 TESE Alessandra Lee Barbosa Firmo.pdf: 5891703 bytes, checksum: 8757ac807155466d5e195ef525335be4 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-10T14:21:50Z (GMT). No. of bitstreams: 2 TESE Alessandra Lee Barbosa Firmo.pdf: 5891703 bytes, checksum: 8757ac807155466d5e195ef525335be4 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-07-02 / CNPq / O avanço no entendimento dos processos de biodegradação em resíduos sólidos urbanos (RSU), impulsionado pelo desenvolvimento de técnicas experimentais de laboratório e campo específicas, tem permitido o desenvolvimento de ferramentas numéricas que podem descrever de forma mais detalhada o processo de geração de biogás em um aterro (considerando a heterogeneidade do material, características e operação do local) e as alterações que podem acontecer no meio poroso ao longo do processo de biodegradação. Para a solução de um modelo matemático desta natureza, programas computacionais baseados em técnicas numéricas como o método dos elementos finitos podem ser desenvolvidos e adaptados para diversas situações. Neste trabalho, primeiramente foram utilizados modelos usuais para analisar a geração de biogás em um aterro experimental no qual foi observado que os modelos multicomponentes melhor representaram a geração de biogás, desde que os parâmetros de entrada sejam adotados cautelosamente. Em seguida, os parâmetros de entrada do modelo multicomponente foram estudados através de experimentos de laboratório com condições iniciais e de controle mais definidas, como os experimentos BMP (Biochemical Methane Potential) e reatores piloto, analisando o efeito da composição dos resíduos e inoculação com lodo anaeróbio. Com os dados experimentais, foi possível determinar o potencial de geração de biogás e metano e a velocidade de degradação dos resíduos sob as condições de cada experimento. Assim, estes dados experimentais foram analisados e utilizados como dados de entrada em um programa computacional em elementos finitos desenvolvido in house (CODE_BRIGHT), no qual foi implementado o modelo multicomponente IPCC (2006), que melhor representou o comportamento da geração de biogás em todos os experimentos. Os dados experimentais e o modelo computacional desenvolvidos neste estudo permitiram analisar o comportamento da geração de biogás em um sistema controlado de biodegradação, simulando as condições de um biodigestor simplificado (simulando casos 2D) e do aterro experimental (caso 3D). Neste último, foi considerado o sistema de drenagem vertical existente conseguindo representar o comportamento do fluxo de biogás semelhante ao encontrado em campo. Assim, cerca de 40% do total do biogás gerado foi captado pelo sistema de drenagem e outra parte foi emitido pela camada de cobertura ou acumulado no meio. Por fim, também foi possível analisar a distribuição espacial e temporal da pressão de gás, de líquido e temperatura no aterro experimental, representando seu comportamento dinâmico no qual normalmente não é examinado de forma detalhada em um aterro real.
4

Análise da degradação e do poder calorífico de resíduos sólidos urbanos. / Analyse de la dégradation et du pouvoir calorifique des déchets dans les solides urbains. / Analysis of the degradation and calorific power of waste to urban solids (garbage) / Análisis de la degradación y del poder calorífico de residuos sólidos urbanos.

QUEIROZ, Abílio José Procópio. 06 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-06T21:19:15Z No. of bitstreams: 1 ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5) / Made available in DSpace on 2018-04-06T21:19:15Z (GMT). No. of bitstreams: 1 ABÍLIO JOSÉ PROCÓPIO QUEIROZ - DISSERTAÇÃO PPG-CEMat 2014..pdf: 5068589 bytes, checksum: 8bb50d0449bc510a3c3f1cd6c496edd3 (MD5) Previous issue date: 2014-08-27 / O gerenciamento de resíduos sólidos urbanos, atualmente feito de forma errônea na maior parte das cidades brasileiras, acelerando a degradação do meio ambiente, e a busca por fontes alternativas de energia, para suprimento da crescente demanda, são problemáticas atualmente discutidas e que precisam de soluções urgentes. Este estudo identifica características físicoquímicas de RSU, depositados em biorreator que simula as condições de um aterro sanitário, e avalia a possibilidade de utilização de um material que ainda é descartado como combustível para geração de energia. O objetivo geral foi avaliar a degradação e o poder calorífico de resíduos sólidos urbanos. As amostras analisadas por FTIR, DRX, TG e DSC foram coletadas em lisímetro construído na Universidade Federal de Campina Grande e preenchido de RSU previamente caracterizados. Os ensaios de FTIR indicaram a predominância orgânica dos materiais presentes nas amostras de RSU. Pelos difratogramas de raios-X o principal pico e comum a todas amostras foi de quartzo, justificando a presença do solo de recobrimento das amostras. As amostras de RSU apresentaram baixa estabilidade térmica, ocorrendo degradação entre a temperatura ambiente e 1000 ºC, sendo visível e aceitável afirmar que ocorrem em cinco etapas de perda associadas à volatilização dos solventes (água e álcoois), à queima de celulose, borracha natural, matéria orgânica putrescível e materiais plásticos, bem como dos óxidos formados durante o processo. Pelas curvas DSC foram identificadas uma reação endotérmica, associada à primeira perda de massa, e quatro reações, duas endotérmicas e duas exotérmicas, ligadas às perdas da degradação dos componentes orgânicos. Os 348.402 kg/dia de RSU produzidos em Campina Grande, amostrados pela massa do biorreator, possuem um poder calorífico médio de 3.744,86 kcal/kg e poderiam ser gerados 1.518.551,40 kW.h/dia de energia térmica ou 303.710,28 kW.h/dia de energia elétrica, com eficiência de conversão de 20%. / The management of municipal solid waste, currently done wrongly in most Brazilian cities, accelerating the degradation of the environment, and the search for alternative energy sources to supply the growing demand, are currently discussed and problems that need solutions urgent. This study identifies physical and chemical characteristics of MSW deposited in bioreactor that simulates the conditions of a landfill site, and evaluates the possibility of using a material that is still dismissed as fuel for power generation. The overall objective was to evaluate the degradation and the calorific value of municipal solid waste. The samples analyzed by FTIR, XRD, TG and DSC were collected in lysimeter constructed at the Federal University of Campina Grande and filled MSW previously characterized. FTIR tests indicated a predominance of the organic materials present in samples of MSW. By X-ray diffraction main peak and common to all samples was quartz, which explains the presence of the soil cover of the samples. MSW samples had poor thermal stability, degradation occurring between room temperature and 1000 ºC, being visible and acceptable state that occurs in five steps loss associated volatilization of the solvents (water and alcohol), the combustion of cellulose, natural rubber, putrescible organic matter and plastics, as well as the oxides formed during the process. DSC curves for an endothermic reaction associated with the first weight loss and four reactions, two endothermic and exothermic two linked to the loss of the degradation of the organic components have been identified. The 348,402 kg/day of USW produced in Campina Grande, sampled by mass of the bioreactor have an average calorific value of 3,744.86 kcal/kg, and could be generated 1,518,551.40 kW.h/day of thermal energy or 303,710. 28 kW.h/day of electricity, with conversion efficiency of 20%.

Page generated in 0.077 seconds