• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 31
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 79
  • 79
  • 79
  • 26
  • 24
  • 24
  • 13
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

The effect of the surface roughness of prepared teeth on the retention of castings

Smith, Bernard G. N. January 1968 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1968. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 52-54).
32

Cavity linings and varnishes a thesis submitted in partial fulfillment ... dentistry for children /

Walsh, Cameron T. January 1947 (has links)
Thesis (M.S.)--University of Michigan, 1947.
33

Avaliação da forma de preparos cavitários confeccionados a partir do sistema CVDentus /

Josgrilberg, Érika Botelho. January 2005 (has links)
Resumo: Foi avaliado a morfologia de preparos cavitários realizados com o sistema CVDentus® variando-se a potência do ultra-som. As cavidades foram preparadas com a ponta cilíndrica modelo 8.2142, na face vestibular de 15 incisivos bovinos, que foram divididos em 3 grupos: G1 utilizando a potência II do aparelho de ultra-som, G2 a potência III e G3 potência IV do mesmo aparelho, na máquina padronizadora de preparos cavitários durante 1 minuto para cada preparo. Após, os preparos foram seccionados ao meio obtendo-se duas hemi-faces com seus perfis, que foi observado em Lupa Estereoscópica e medidos por meio do programa Leica Qwin. De acordo com os testes estatísticos Kruskal-Wallis e método de Dunn, houve diferença entre a largura e a profundidade dos preparos somente quando comparados às potências III e IV do aparelho de ultrasom, e que a largura da cavidade realizada pela potência III é a mais semelhante ao diâmetro real da ponta. Concluiu-se que a potência III indicada pelo fabricante é de fato a mais apropriada para o uso na clínica diária, pois possibilita a realização de preparos conservadores. / Abstract: This study has evaluated the shape of dental cavities made by CVDentus® system with ultrasound potency variation. The cavities have been made on buccal face of 15 bovine incisors with acylindrical bur (82142). The sample have been divided into three groups: G1, using ultrasound power II; G2, using power II, and G3, using power IV with a standard device. The cavities have been sliced in the middle, allowing thereby the cavity's profile observation with magnifying glasses, and measurement with a Leica Qwin program. The Kruskall-Wallis and Dunn statistical analysis has shown differences between dental cavities shapes when power III and IV were used. However, the cavities who have been made with power III were similar to bur dimension. Therefore, we conclude that the manufacturer indication to use power III is more suitable to clinical use because it allows more conservative cavity preparation. / Orientador: Cyneu Aguiar Pansani / Coorientador: Rita de Cassia Loiola Cordeiro / Banca: Evaldo José Corat / Banca: Silvio Issáo Myaki / Mestre
34

A clinical evaluation of the effect of polishing procedures on the marginal breakdown of two dental amalgams

Adams, George Austin, 1949- January 1977 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The investigation was undertaken to determine the effects of the polishing and finishing of dental amalgam in relation to its marginal breakdown. The study was also conducted to make a clinical comparison of the marginal integrity of Dispersalloy restorations as compared to Twentieth Century Fine Cut Alloy restorations in both the polished and unpolished state. Forty patients with a total of 131 Class I amalgam restorations were used as the study group. The two alloy systems and polish or unpolish techniques were selected from a random table. Photographic evaluation of the restorations was used to judge the degree of marginal breakdown. The results of the study at the one-year evaluation show two main findings: (1) the Dispersalloy restorations showed less marginal breakdown than the Twentieth Century Fine Cut Alloy restorations, and (2) there was no significant difference between the polished and unpolished restorations overall.
35

Bacterial penetration of varnish-lined amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Harrison, Lee Moncrief. January 1964 (has links)
Thesis (M.S.)--University of Michigan, 1964.
36

A method for the photoelastic study of stresses developed in dental structures a thesis submitted in partial fulfillment ... dentistry for children ... /

King, Richard M. January 1953 (has links)
Thesis (M.S.)--University of Michigan, 1953.
37

Bacterial penetration of varnish-lined amalgam restorations a thesis submitted in partial fulfillment ... pedodontics /

Harrison, Lee Moncrief. January 1964 (has links)
Thesis (M.S.)--University of Michigan, 1964.
38

Avaliação da forma de preparos cavitários confeccionados a partir do sistema CVDentus

Josgrilberg, Érika Botelho [UNESP] 03 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-03Bitstream added on 2014-06-13T19:35:58Z : No. of bitstreams: 1 josgrilberg_eb_me_arafo.pdf: 895515 bytes, checksum: 121a11d0eecc4c18e0cf9eb1de8128a9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi avaliado a morfologia de preparos cavitários realizados com o sistema CVDentus® variando-se a potência do ultra-som. As cavidades foram preparadas com a ponta cilíndrica modelo 8.2142, na face vestibular de 15 incisivos bovinos, que foram divididos em 3 grupos: G1 utilizando a potência II do aparelho de ultra-som, G2 a potência III e G3 potência IV do mesmo aparelho, na máquina padronizadora de preparos cavitários durante 1 minuto para cada preparo. Após, os preparos foram seccionados ao meio obtendo-se duas hemi-faces com seus perfis, que foi observado em Lupa Estereoscópica e medidos por meio do programa Leica Qwin. De acordo com os testes estatísticos Kruskal-Wallis e método de Dunn, houve diferença entre a largura e a profundidade dos preparos somente quando comparados às potências III e IV do aparelho de ultrasom, e que a largura da cavidade realizada pela potência III é a mais semelhante ao diâmetro real da ponta. Concluiu-se que a potência III indicada pelo fabricante é de fato a mais apropriada para o uso na clínica diária, pois possibilita a realização de preparos conservadores. / This study has evaluated the shape of dental cavities made by CVDentus® system with ultrasound potency variation. The cavities have been made on buccal face of 15 bovine incisors with acylindrical bur (82142). The sample have been divided into three groups: G1, using ultrasound power II; G2, using power II, and G3, using power IV with a standard device. The cavities have been sliced in the middle, allowing thereby the cavity’s profile observation with magnifying glasses, and measurement with a Leica Qwin program. The Kruskall-Wallis and Dunn statistical analysis has shown differences between dental cavities shapes when power III and IV were used. However, the cavities who have been made with power III were similar to bur dimension. Therefore, we conclude that the manufacturer indication to use power III is more suitable to clinical use because it allows more conservative cavity preparation.
39

Avaliação das dimensões e aspectos morfológicos da cavidade promovida pela ablação do esmalte de dentes decíduos irradiados pelo laser de Er:YAG

Giusti, Juçaíra Stella Martins [UNESP] 07 March 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-03-07Bitstream added on 2014-06-13T20:56:56Z : No. of bitstreams: 1 giusti_jsm_me_arafo.pdf: 1950651 bytes, checksum: 6fab906468c3160220b340e3664b33d6 (MD5) / O propósito desse estudo in vitro foi analisar as características morfológicas das cavidades em esmalte promovidas pela irradiação de dentes decíduos com laser de Er:YAG, bem como avaliar as dimensões das cavidades de acordo com a variação de energia aplicada, 200 mJ e 300 mJ , mantendo-se constante a freqüência de 10 Hz e 10 s o tempo de aplicação. Foram utilizados quatorze dentes decíduos esfoliados, que foram irradiados e tiveram seu diâmetro e profundidade medidos por meio de fotomicrografias obtidas após microscopia eletrônica de varredura, utilizando um programa de análise cefalométrica. Pudemos observar que as características morfológicas são as mesmas observadas por outros autores em dentes permanentes: cavidades arredondadas com bordas delimitadas e presença de escamas ou flocos no fundo da cavidade.Quanto às dimensões dos preparos observou-se que o diâmetro da cavidades não aumentou significativamente com o aumento da energia (média de 1033,37 mm para 200 mJ e 1083,75 mm para 300 mJ), enquanto a profundidade teve um aumento estatisticamente significante em relação ao aumento da energia aplicada (média de 153,69 mm para 200 mJ e 296,67 mm para 300 mJ). O volume foi estatisticamente superior nos preparos realizados com 300 mJ de energia. / The aim of this in vitro study was to analyze the morphology, diameter, depth and volume of the cavities prepared in deciduous teeth enamel using laser. Fourteen exfoliated teeth were irradiated by Er:YAG laser set at 200 and 300 mJ of energy and 10Hz of frequency, applied during 10 seconds. The morphology, diameter and depth of the cavities were measured on scanning electron micrographs using a cephalometric program and the volume was calculated. The cavities presented round shape and flakes or scales pattern were observed in the bottom. There was no significant statistical difference in the diameter of the cavities when 200 mJ (1033,37 mm) or 300 mJ (1083,75 mm) were used. The depth was statistically greater when energy was increased ( 153,69 mm and 296,67 mm to 200 and 300 mJ respectively). The volume also increased when 300 mJ was use.
40

CVDentus® X micromotor na segunda infância: avaliação de aspectos técnicos, comportamentais e da agradabilidade / CVDentUS® x low speed handpiece in the 2nd childhood: evaluation of technical and behavioral aspects and pleasantness

Carvalho, Flávia Patto 09 May 2011 (has links)
O tratamento odontológico geralmente envolve ansiedade nos pacientes decorrente da vibração e ruído provocado pelos instrumentos rotatórios. A instrumentação ultrassônica é uma alternativa ao instrumento rotatório convencional, pois proporciona segurança e conforto ao paciente, além de execução simples e fácil. O presente estudo teve como objetivo comparar o uso de brocas convencionais usadas em micromotor (MM) com, pontas diamantadas CVDentus® no equipamento CVDent1000 (CVD) para remoção de tecido cariado e preparo cavitário em crianças, avaliando os aspectos técnicos das pontas, o comportamento das crianças e a agradabilidade dos equipamentos. Participaram 30 crianças de 36 a 71 meses, apresentando pelo menos dois molares decíduos com lesão de cárie oclusal ativa incipiente, ou com lesão questionável, em fossas e fissuras. A amostra foi subdividida em duas fases. Na fase 1, o CVD foi comparado ao MM sem refrigeração e, na fase 2, com o MM sob refrigeração. Este estudo seguiu o modelo split mouth, e o critério de escolha do dente e do equipamento usado na primeira criança foi aleatório, através de sorteios inicialmente e depois, programado para o equipamento. O tratamento foi realizado em uma única sessão, sem anestesia local, sob isolamento relativo, e os dentes restaurados com cimento de ionômero de vidro convencional. Os aspectos técnicos dos sistemas nas fases 1 e 2, avaliados pelo operador, incluíram os parâmetros visualização da área de trabalho (VAT), acesso á cavidade (AC), remoção do tecido cariado (RTC) e ruído e vibração (RV). O comportamento da criança (Cpt) também foi avaliado. As crianças avaliaram a agradabilidade dos equipamentos pela Escala Analógica Visual de Faces de McGrath (1990) Modificada, somente na fase 2. Na fase 1 houve diferença significantemente superior para o CVD nos critérios Cpt (p=0,0431), AC (p=0,0009) e RV (p=0,0006), sendo estes dois últimos também significantes na fase 2, com o mesmo valor de p (Teste de Mann-Whitney). Nos demais critérios, o MM foi superior apenas no RTC, mas não significante. O sistema CVD parece ser uma alternativa promissora. No entanto, são necessários outros estudos para esclarecer aspectos ainda não totalmente entendidos, para que a sua indicação e aplicação em odontopediatria sejam apoiadas por uma evidência científica consistente. / The dental treatment usually involves anxiety in patients due to vibration and noise caused by the rotary instruments. The ultrasonic instrumentation is an alternative to the conventional rotatory instrument, device as it provides security and comfort to the patients, beyond simple and easy execution. The objective of this study was to compare the use of conventional handpiece and drills versus diamond burs CVDentus® system CVDent1000® equipment (CVD) for caries removal and cavity preparation in children, evaluating their clinical performance, behavior children and the pleasantness of the equipment. The sample was composed by 30 children from 36 to 71 months, with at least two primary molars with occlusal incipient active or questionable pits and fissures dental caries. The study was divided into two phases. In the phase one, the CVD was compared to HP without refrigeration, and in the phase two, with HP under refrigeration. This study followed a \"split mouth\" design, and the tooth and the equipment used for the first child were randomly selected by lottery at the beginning, then the selection was programmed for the equipment. The treatment was performed in a single session, without local anesthesia, under rubber dam isolation, and the teeth were restored with conventional glass ionomer cement. The clinical performance of the systems in the two phases was evaluated by the operator, and included the parameters working area view (WAV), access to the cavity (AC), removal of carious tissue (RCT) and noise and vibration (NV). The child\'s behavior (B) was also evaluated. Children rated the pleasantness of the equipment by the modified VAS Faces of McGrath (1990), only in phase 2. There was a higher and significant difference for CVD in the criteria B (p = 0.0431), AC (p = 0.0009) and NV (p = 0.0006). These last two criteria were also significant in phase 2, with the same p value (Mann-Whitney). For the other criteria, the MM was only superior in RCT, but not significant. The CVDentus® system seems to be a promising alternative. However, additional studies are necessary to clarify aspects that were not completely understood, so that its indication and application in pediatric dentistry being supported by consistent scientific evidence.

Page generated in 0.1418 seconds