Caracterização microestrutural e resistência à corrosão de ligas Ni-Cr-Mo refundidas utilizadas em próteses dentárias /

Sousa, Lucíola Lucena de. January 2005 (has links)
Resumo: O objetivo deste trabalho foi estudar o efeito de diferentes processos de refundição e resfriamento na microestrutura e nas propriedades mecânicas e eletroquímicas de duas ligas de Ni-Cr-Mo, Wiron 99 e Wironia, utilizadas em próteses dentárias fixas. As ligas como recebidas (bruta de fusão) foram refundidas em chama aberta com maçarico oxi-GLP e por indução em forno de alta freqüência utilizando diferentes velocidades de resfriamento. As microestruturas reveladas por ataque eletroquímico nas amostras bruta de fusão (BF), foram analisadas por microscopia ótica e eletrônica de varredura, apresentam caráter dendrítico; as amostras refundidas apresentam duas fases: uma solução sólida de Ni-Cr-Mo e precipitados. A região de precipitados tem maior teor de Mo que na fase principal. As amostras Wironia refundida em chama aberta (MRL), refundidas por indução seguida de resfriamento em água fria (IRR) e seguida de resfriamento natural (IRL) apresentam maior número de precipitados que a Wiron 99. O estudo eletroquímico foi realizado em meio de NaCl 0,9% em massa, pH 6 a 37ºC, utilizando as técnicas de medidas de potencial em circuito aberto, polarização potenciodinâmica e voltametria cíclica. Diferentes procedimentos de refundição alteram parâmetros eletroquímicos como potencial de estabilização em circuito aberto, densidade de corrente e intervalo de passivação. As alterações foram mais pronunciadas para as ligas Wironia IRL e Wiron 99 IRL. Ensaios de imersão durante um ano em solução de NaCl 0,9% mostraram dissolução de Ni, Cr e Mo em maior quantidade para a Wironia MRL e IRR. A dureza e a resistência à abrasão foram menores nas ligas refundidas do que nas BF. Diferentes procedimentos de refundição e resfriamento afetam a microestrutura e a resistência à corrosão destas ligas. / Abstract: This work aim has been to study the effect of different recast and cooling processes in microstructure and in mechanical and electrochemical properties of two Ni-Cr-Mo alloys, Wiron 99 and Wironia, used in fixed dental prostheses. The alloys as-received (as-cast) have been recast in an open flame (oxy-LPG torch) and through induction in high frequency furnace by using different cooling rates. Microstructures revealed through as-cast (AC) electrochemical attack analyzed through light and scanning electronic microscopy present dendritic character; recast samples present two phases: a Ni-Cr-Mo solid solution and precipitates. Precipitates region has Mo content greater than the main phase. Wironia samples recast through open flame (TSC - Torch followed by slow cooling), recast through induction followed by cooling in cold water (IRC - Induction followed by rapid cooling) and then by natural cooling (ISC - Induction followed by slow cooling) present a precipitate number greater than Wiron 99. Electrochemical study has been carried out in 0.9% NaCl, pH 6 at 37°C, by using open circuit potential techniques, potentiodynamic polarization and cyclic voltammetry. Different recast procedures change electrochemical parameters as stabilizing potential in open circuit, current density and passivation interval. Changes have been more markedly for ISC Wironia and ISC Wiron 99. Immersion tests during one year in NaCl 0.9% have displayed Ni, Cr and Mo dissolution in major quantity for TSC and IRC Wironia. Hardness and abrasion resistance have been smaller for recast than in AC alloys. Different recast and cooling procedures affect microstructure and corrosion resistance of these alloys. / Orientador: Hamilton de Felipe / Coorientador: Eduardo Norberto Codaro / Banca: Roberto Zenhei Nakazato / Banca: Gilberto Luis Jardim Pinto da Silva / Mestre
2

Efeito de tratamentos térmicos na resistência à tração e na dureza Vickers do Ti c.p. e da liga Ti-6Al-4V obtidos por fundição odontológica /

Rocha, Sicknan Soares da. January 2002 (has links)
Orientador: Gelson Luis Adabo / Banca: Luís Geraldo Vaz / Banca: Guilherme Elias Pessanha Henriques / Resumo: O objetivo desta investigação foi determinar se os tratamentos térmicos podem alterar a resistência à tração e a dureza Vickers do Ti c.p. e da liga Ti-6Al-4V. Trinta corpos-de-prova na forma de halteres com 3,0 mm no segmento central e 42 mm de comprimento, obtidos por meio de uma matriz de alumínio, foram fundidos no sistema Rematitan. Os corpos-de-prova de Ti c.p. e Ti-6Al-4V foram divididos aleatoriamente em três grupos de 10 cada, e submetidos às seguintes condições de tratamento térmico: (1) controle; (2) T1 - aquecimento a 750ºC/2 h; (3) T2 - recozimento a 955ºC/1 h e envelhecimento a 620ºC/2 h. Ambos, aquecimento e resfriamento, foram realizados em atmosfera controlada de argônio. O ensaio de tração foi efetivado na máquina de testes mecânicos MTS modelo 810 à velocidade de 1,0 mm/min. Após o teste de tração uma das extremidades do corpo-de-prova foi embutida em resina acrílica, regularizada e polida antes da medida da dureza Vickers no durômetro Micromet 2100. As médias de resistência à tração e dureza Vickers foram comparadas estatisticamente usando o teste não-paramétrico de Kluskall-Wallis. Nos grupos de Ti c.p. não foram observadas diferenças significativas na resistência à tração, entretanto, na dureza Vickers os resultados do grupo T2 foram significativamente maiores que os outros grupos, que se mostraram iguais entre si. Na liga Ti-6Al-4V os grupos controle e T1 revelaram igualdade estatística em relação à resistência à tração, e significativamente superiores ao grupo T2. Quanto à dureza Vickers, diferenças estatisticamente significantes foram observadas entre os três grupos de tratamento térmico: T2>T1>controle. Não foi observada correlação entre as propriedades de resistência à tração e dureza Vickers. ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this investigation was to determine whether heat treatments could change the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy castings. Thirty dumbbell rods, 3.0 mm in diameter at the central segment and 42 mm in length, obtained from an aluminum matrix, were cast for each metal in the Rematitan system. The specimens of CP Ti and of alloy Ti-6Al-4V, were divided randomly into three groups of ten each; then submitted to the following heat treatments: (1) control group, without heat treatment; (2) T2 - heat at 750ºC for 2 h; (3) annealing at 955ºC for 1 h and aged at 620ºC for 2 h. The heat treatments, as well as the cooling process were conducted in the furnace with argon atmosphere. The tensile strength was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile testing the specimens were embedded in acrylic resin, grounded and polished prior to hardness measurements, using the Vickers tester Micromet 2100. The means and standard deviations of tensile strength and Vickers hardness were statistically compared using Kruskal-Wallis non-parametric test at a=0.05 significance level. In CP Ti groups, no statistically significant differences in tensile strength were observed; however, in Vickers hardness the results of group T2 were significantly higher than the other groups, which showed similar mean values among themselves. In Ti-6Al-4V alloy, the control and T1 groups revealed statistically higher tensile strength when compared to T2 group, with no significant difference between control and T1 group. Regarding Vickers hardness, statistically significant differences were observed among the three heat-treatment groups: T2>T1>control...(Complete abstract, click electronic access below) / Mestre
3

Efeito da concentração do líquido especial e da temperatura do molde de revestimentos na desadaptação marginal de coroas fundidas em titânio /

Rocha, Sicknan Soares da. January 2005 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da concentração do líquido especial e da temperatura do molde dos revestimentos Rematitan Plus, específico para titânio, Rema Exakt e Castorit Super C, alternativos, na desadaptação marginal de coroas fundidas em titânio puro. Para o revestimento Rematitan Plus os padrões de cera foram incluídos à vácuo com três diferentes concentrações do líquido especial, 100%, 75% e 50%, diluídos em água destilada. As fundições foram realizadas na máquina Discovery Plasma com os moldes em três temperaturas, 430ºC, 515ºC e 600ºC. Os revestimentos alternativos foram empregados nas condições em que obtiveram expansão total de 0,8%, equivalente à do Rematitan Plus (100%/430ºC), adotado como grupo controle. Conforme as curvas de expansão de presa e térmica foram estabelecidas as condições de concentração e temperatura: Rema Exakt (100%/220ºC, 75%/240ºC e 50%/340ºC) e Castorit Super C (100%/temperatura ambiente e 75%/160ºC). / Abstract: This study had the goal of assessing the effect of the concentration of the special liquid and the temperature of the mold of Rematitan Plus investment, specific for titanium, Rema Exakt and Castorit Super C, alternative investments, on the marginal misfit of crowns cast on pure titanium. For the Rematitan Plus investment, the wax standards were included in vacuum with three different concentrations of the special liquid, 100%, 75% and 50%, diluted in distilled water. The castings were performed on the Discovery Plasma machine with the molds at three temperatures, 430ºC, 515ºC and 600ºC. The alternative investments were employed under conditions in which they obtained a overall expansion of 0.8%, equivalent to that of the Rematitan Plus (100%/430ºC), adopted as the control group. According to the thermal and setting expansion curves the conditions of concentration and temperature were established: Rema Exakt (100%/220ºC, 75%/240ºC and 50%/340ºC) and Castorit Super C (100%/room temperature and 75%/160ºC). / Orientador: Gelson Luis Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Marco Antonio Compagnoni / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antônio de Arruda Nóbilo / Banca: Cláudio Rodrigues Leles / Doutor
4

Influência de tratamentos superficiais e termociclagem na resistência da união resina/metal /

Almilhatti, Hercules Jorge. January 2004 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Gelson Luis Adabo / Banca: Carlos Eduardo Vergani / Banca: Maria da Glória Chiarello de Mattos / Banca: Ricardo Faria Ribeiro / Resumo: Este estudo teve como objetivo avaliar a efetividade de quatro condicionadores de metal (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL e Siloc, S) aplicados sobre diferentes superfícies das ligas de Ni-Cr, Co-Cr e do metal Ti Cp. Após o polimento metalográfico e jateamento com Al2O3, foram obtidos três grupos experimentais para cada metal : Grupo polimento (P) - controle; Grupo (J50), jateado com Al2O3 de 250 um. A esses grupos foram aplicados os condicionadores e as resinas opaca e de revestimento estético (Artglass). Decorridos 24 horas de armazenamento em água a 37ºC, cada grupo foi dividido em dois grupos e submetidos aos ensaios mecânicos de cisalhamento (0,5 mm/min.), um antes e outro após 500 ciclos térmicos (60ºC e 4ºC). As superfícies fraturadas foram analisadas e o padrão de falhas determinado. Adicionalmente foram feitas análises de MEV e EDS. Seguem os resultados para cada metal: Liga de Ni-Cr: para os Grupos P e J50, não foram observadas diferenças (p>0,05) nos valores médios de tensão de cisalhamento entre os condicionadores OP e TL e entre MPP e S, sendo maiores as médias dos dois primeiros. Não foram encontradas diferenças (p>0,05) entre as médias de tensão para os condicionadores do Grupo J250. No entanto, esses valores foram superiores aos do Grupo J50. Após a termociclagem, as médias para os condicionadores OP, S e TL não apresentaram aumento significante (p>0,05), enquanto a média para o MPP aumentou (p<0,05). Liga de Co-Cr, para o Grupo P, não foram observadas diferenças (p>0,05) nos valores médios de tensão entre os condicionadores OP e TL e entre MPP e S, sendo superiores as médias dos dois primeiros. As médias de tensão para o Grupo J250 foram estatisticamente maiores às do Grupo J50, ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of the study was to evaluated the effect of three adhesive primers (Metal Photo Primer, MPP; Cesead II Opaque Primer, OP; Targis Link, TL) and a bonding system (Siloc, S) on the shear bond strength between a prosthetic composite material (Artglass) to Ni-Cr alloy (Wiron 99), Co-Cr alloy (Wironit), and CP Ti (Tritan). Disk patterns were cast of the 3 alloys. All the disk surfaces were abraded with No. 80, 320, and 600 SiC paper, respectively and three different surface treatment were applied: No. 600 SiC polishing, P; 50 mm Al2O3 sandblasting, S50; 250 mm Al2O3 sandblasting, S250. The composites (Artglass opaque and dentin) were applied using a cylindrical stainless steel split according to manufacturer's instructions then light polymerized. Specimens without primer and bonding system were also prepared as control. The specimens were stored in water a 37oC for 24 h and then shear bond strengths were determined both before and after immersed alternately in water baths at 4oC and 60oC for 15 seconds each for up to 500 thermal cycles before shear mode testing at a crosshead speed of 0.5 mm/min. Data were statistically analyzed using 3-way ANOVA and 1-way ANOVA, followed by Tukey multiple range intervals calculated at the 0.05 significance level. Fractured interfaces were analyzed by use of light microscopy and SEM. Results: Ni-Cr alloy: The bond strength of the P-OP/J50-OP group and P-TL/J50- TL group were statistically comparable (p>0,05) and exhibited greater strength than the P-MPP/J50-MPP group and P-S/J50-S (p<0,05). No significant differences were found among the four conditioners for J250 group (p>0,05), and these group showed the greater strength than the J50 group (p<0,05). After thermocycling, no significant differences (p>0,05) were found among the three primers (OP, S, TL) and the bond strength of MPP increased...(Complete abstract, click electronic access below) / Doutor