• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise comparativa da distribuição de tensões em incisivo central superior, restaurado com diferentes sistemas de pinos intra-radiculares /

Oliveira, Luana Cristina Araújo de. January 2002 (has links)
Resumo: Neste trabalho é proposto analisar a distribuição de tensões produzidas na dentina radicular do incisivo central superior restaurado com diferentes sistemas de pinos intra-radiculares, através dos Métodos de Fotoelasticidade e Elementos Finitos. Esta análise foi realizada para os seguintes sistemas de pinos intra-radiculares: fibra de carbono, fibra de vidro, zircônio, aço inoxidável, titânio e metálico fundido (Liga de Cu-Al), o dente hígido foi utilizado como controle. Em ambos método foi construído um modelo bidimensional representativo do incisivo central superior e aplicada uma carga de 100 N no terço incisal da região palatina com um inclinação de 45º em relação aoa longo eixo do dente. Os resultados foram expressos em função da Tensão de Von Mises - Se e Sy, e valor da Ordem de Franja, para o Método de Elementos Finitos e Fotoelasticidade, respectivamente. Através da análise dos resultados, concluiu-se que houve diferenças significativas na distribuição de tensão entre os seis sistemas de pinos testados, sendo que, os pinos de zircônio, aço inoxidável, titânio e metálico fundido, promoveram uma alta concentração de tensões na região conduto radicular ao longo da interface pino/dentina. Nos pinos de fibra de vidro e fibra de carbono houve uma distribuição de tensões uniforme ao longo de toda a superfície radicular, não se verificou áreas de concentração de tensões produzidas por estes sistemas de pinos. Os pinos de zircônio, aço inoxidável, titânio e metálico fundido apresentaram propriedades mecânicas diferentes da estrutura dental, promovendo alterações significativas no comportamento mecânico do dente. De acordo com estes resultados, concluímos que os pinos não metálicos atendem de maneira satisfatória os requisitos necessários para proporcionarem um comportamento mais semelhante à estrutura dental, a compatibilidade... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: This work proposes a study about the distribution of mechanical stresses in the radicular dentin of restored with different posts systems, by means of the photoelastic and the finite element techniques. This analysis is conducted for the following posts systems: carbon fiber, fiberglass, zirconium, stainless steel, titanium and cast metal (Cu-Al alloy) and the healthy tooth (control). For this purpose, representative two-dimensional models of the central upper incisor are built for both methods. These models are subject to a 100N load applied at the tip of the crown, at 45º from the axle along the tooth. The results are expressed in terms of the Von Mises and Sy stresses and the fringe order, for the finite element and photoelastic methods, respectively. Through the analysis of these results, it can be concluded that significant stress distribution differences arise between the six different pin systems tested, so that those made of zirconium, stainless steel, titanium and cast metal produced high stress concentration at the post/dentin interface region. In the cases of the carbon fiber and fiberglass pins, on the other hand, the stress distribution along the radicular surface is uniform, lacking stress concentration areas. The zirconium, stainless steel, titanium and cast metal pins present mechanical properties which are different from those of the tooth structure, resulting in significant alterations over the mechanical behavior of the dental structure. The non-metallic pins comply more satisfactorily with the requirements necessary to provide a mechanical behavior more similar to that of the dental structure, the compatibility among the mechanical properties found in these system and the dentin providing a biomimetic behavior, reducing the risk of failure or root fractures. / Orientador: Maria Salete Machado Cândido / Coorientador: Sônia Aparecida Goulart Oliveira / Banca: Jesuânia Maria Guardiero Azevedo Pfeifer / Banca: Welingtom Dinelli / Mestre
2

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro /

Lima, Luiz Rafael Calixto. January 2009 (has links)
Resumo: A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs. / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Alessandra Nara de Souza Rastelli / Banca: José Roberto Cury Saad / Banca: Edson Alves de Campos / Mestre
3

Influência de soluções irrigadoras na resistência adesiva de pinos de fibra de vidro utilizando cimento resinoso : avaliação através do teste de push-out /

Figueiredo, Mariana Diehl. January 2011 (has links)
Orientador: Claudio Antonio Talge Carvalho / Banca: Renato Miotto Palo / Banca: Márcia Carneiro Valera / Resumo: Atualmente, os pinos de fibra de vidro têm surgido como uma alternativa para restaurar dentes tratados endodonticamente. Entretanto, a perda da retenção do pino é uma das principais causas de falhas. Portanto, o objetivo deste estudo foi avaliar a resistência de união e o tipo de falha adesiva, em diferentes regiões da raiz, de pinos de fibra de vidro transparente cimentados no canal radicular com cimento de cura dual, variando-se a solução irrigadora utilizada durante o preparo dos canais, através do teste de push-out. Para o estudo, foram utilizados 30 dentes humanos, todos igualmente preparados. No momento da cimentação dos pinos, as soluções irrigadoras foram: solução de soro fisiológico, hipoclorito de sódio 2,5% e solução de clorexidina 2%; e o cimento resinoso utilizado foi de cura dual. Após a cimentação, os espécimes foram seccionados, obtendo-se 2 fatias de aproximadamente 2 mm cada, suas faces cervicais foram marcadas, e então, submetidas ao teste de push-out. Foram realizados os testes ANOVA e Tukey, com nível de significância de 5 %, para a análise do ensaio mecânico e realizada análise qualitativa do tipo de falha ocorrida. Pôde-se observar que o grupo irrigado com hipoclorito de sódio 2,5% apresentou menor valor da média de resistência adesiva (3,870 ± 3,799 MPa), comparado com o grupo da clorexidina 2% (4,215 ± 2,098 MPa) e com o grupo do soro (4,510 ± 1,186 MPa). Já em relação aos terços, a região média foi a que apresentou maior valor da média de resistência adesiva (4,803 ± 3,14 MPa) quando comparado com a região cervical (3,593 ± 1,717 MPa), porém não houve diferença estatística significante, nem entre as regiões e nem entre as soluções irrigadoras. A maioria das falhas ocorridas foram do tipo adesiva 70%, enquanto que 23,33% foram fraturas coesivas, e 6,66% foram do tipo mistas. Assim, é possível concluir que os ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Currently, the fiberglass posts have emerged as an alternative to restore endodontically treated teeth. However, the loss of retention of the pin is a major cause of failure. Therefore, the aim of this study was to evaluate and compare the bond strength of transparent fiberglass posts, using a dual cure cement, varying the irrigating solution used during the preparation of the root canals through the push-out test and then a qualitative analysis of types of adhesion failures was made by reading into a stereomicroscope. For the study, 30 human teeth were used, all equally prepared. At the time of cementation of the posts, the irrigating solutions were: normal saline solution, sodium hypochlorite 2.5%, and 2% chlorhexidine solution, and the resin cement used was dual-curing. After cementation, specimens were sectioned, yielding two slices of about 2 mm each, their cervical faces were marked, and then subjected to push-out test, the data obtained were analyzed by descriptive and inferential statistics. The tests performed were ANOVA and Tukey, with a significance level of 5% for the analysis of mechanical test, and the type of failure occurred was qualitatively evaluated. It could be observed that the group irrigated with sodium hypochlorite 2.5% showed the lowest mean bond strength (3.870 ± 3.799 MPa), compared with 2% chlorhexidine group (4.215 ± 2.098 MPa) and the normal saline solution group (4.510 ± 1.186 MPa). In relation to the thirds, the middle region showed the highest value of bond strength average (4.803 ± 3.14 MPa) compared with the cervical (3.593 ± 1.717 MPa), but differences were not statistically significant, nor between regions nor between irrigating solutions. Most failures were adhesive type 70%, while 23.33% were cohesive fractures, and 6.66% were mixed type. Thus, we conclude that the irrigation protocols evaluated in this study did not exert effects on the bond ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0581 seconds