• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de diafragma piezelétrico no monitoramento das condições da superfície da peça em processo de retificação plana tangencial / Evaluation of the piezoelectric patch in the monitoring of the surface conditions of the workpiece in the tangential flat grinding process

Fabiano, Luiz Felipe Gilli [UNESP] 09 December 2016 (has links)
Submitted by LUIZ FELIPE GILLI FABIANO null (luiz_gilli@hotmail.com) on 2017-01-28T11:38:47Z No. of bitstreams: 1 Dissertação Luiz Felipe Gilli Fabiano.pdf: 4348153 bytes, checksum: dec59fbb55fc39d0a5d03e18877ac8c2 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-31T17:24:36Z (GMT) No. of bitstreams: 1 fabiano_lfg_me_bauru.pdf: 4348153 bytes, checksum: dec59fbb55fc39d0a5d03e18877ac8c2 (MD5) / Made available in DSpace on 2017-01-31T17:24:36Z (GMT). No. of bitstreams: 1 fabiano_lfg_me_bauru.pdf: 4348153 bytes, checksum: dec59fbb55fc39d0a5d03e18877ac8c2 (MD5) Previous issue date: 2016-12-09 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os processos de usinagem são de extrema importância para a fabricação de peças mecânicas, as peças exigem alta precisão dimensional e geométrica e qualidade no acabamento ao serem manufaturadas. Dentre os processos de usinagem, a retificação se destaca por ser um dos processos mais usado, por sua precisão e bom acabamento. É essencial que se conheça bem este processo, já que o mesmo se encontra na última etapa da manufatura. Assim, problemas durante o processo de retificação compromete-se a peça e pode-se perder o trabalho realizado em todas as etapas anteriores, acarretando alto custo na produção e perda de matéria-prima. O presente trabalho tem como objetivo avaliar um método de monitoramento das condições da superfície das peças, realizando um estudo comparativo da integridade superficial de peças retificadas com os sinais captados por um diafragma piezelétrico de baixo custo composto por Titanato Zirconato de Chumbo (PZT), bem como por um sensor de emissão acústica (EA). Os ensaios experimentais foram realizados em uma máquina retificadora plana, onde um banco de ensaios foi desenvolvido empregando-se um rebolo de CBN com ligante resinóide e corpos de prova de aço ABNT 1045 e VC131. Posteriormente, para caracterizar a superfície das peças, foi realizada a inspeção visual, medidas de rugosidade (Ra), medidas de microdureza Vickers e uma análise metalográfica. Os sinais EA e PZT foram aquisitados através de um osciloscópio de alta amostragem e, posteriormente, tratados com filtros digitais. Na sequência, esses sinais, foram comparados com a queima e a rugosidade de cada peça em suas respectivas condições, através de técnicas de processamento de sinais. Notou-se que o aumento da rugosidade, bem como a ocorrência da queima da peça, possui um relacionamento com aumento do sinal RMS do PZT e da EA, bem como com o índice RMSD. Já o índice CCDM não possuiu correlação com as condições do processo. Verificou-se por meio deste estudo um bom desempenho do diafragma PZT com potencial para concorrer com o sensor de EA visando monitorar a integridade superficial das peças retificadas, de acordo com a análise espectral e o estudo do sinal nas devidas bandas de frequência identificadas. / The machining processes are of utmost importance for the manufacture of mechanical parts, the parts require high dimensional and geometric precision and quality in the finishing of the surfaces when being manufactured. Among the machining processes, grinding stands out as one of the most used processes, due to its precision and superior finishing. It is essential that this process is well known, since it is in the last stage of manufacturing. Thus, problems during the grinding process are committed to the part and can be lost the work carried out in all previous stages, resulting in high production costs and loss of raw material. The present work aims to evaluate a method of monitoring the surface conditions of the parts, performing a comparative study of the surface integrity of rectified parts with the signals captured by a low-cost piezoelectric patch composed of Lead Titanium Zirconate (LZT) and as by an acoustic emission sensor (EA). Experimental tests were performed in a flat grinding machine, where a test bench was developed using a CBN grinding wheel with resinoid binder and ABNT 1045 and VC131 steel test bodies. Later, to characterize the surface of the parts, visual inspection, surface roughness (Ra), Vickers microhardness measurements and a metallographic analysis were performed. The signals EA and PZT were acquired through a high sampling oscilloscope and later treated with digital filters. These signals were then compared to the firing and roughness of each part under their respective conditions, through signal processing techniques. It was observed that the increase of the roughness, as well as the occurrence of the burning of the parts, has a relationship with increase of the RMS signal of the PZT and the EA, as well as with the RMSD index. The CCDM index had no correlation with the process conditions. A good performance of the PZT patch with potential to compete with the EA sensor was verified in order to monitor the surface integrity of the rectified parts, according to the spectral analysis and the study of the signal in the appropriate frequency bands identified.
2

Utilização de diafragmas piezelétricos para o monitoramento da qualidade superficial de peças de aço na retificação plana / Piezoeletric diaphragms applied for monitoring surface quality of steel parts in grinding

Ribeiro, Danilo Marcus Santos [UNESP] 25 May 2017 (has links)
Submitted by DANILO MARCUS SANTOS RIBEIRO null (danpayne16@msn.com) on 2017-07-11T18:22:50Z No. of bitstreams: 1 dissertação_danilo_marcus_v9_final.pdf: 3798083 bytes, checksum: 8969b64b8101340dd46391b7669f950a (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-07-14T16:55:13Z (GMT) No. of bitstreams: 1 ribeiro_dms_me_bauru.pdf: 3798083 bytes, checksum: 8969b64b8101340dd46391b7669f950a (MD5) / Made available in DSpace on 2017-07-14T16:55:13Z (GMT). No. of bitstreams: 1 ribeiro_dms_me_bauru.pdf: 3798083 bytes, checksum: 8969b64b8101340dd46391b7669f950a (MD5) Previous issue date: 2017-05-25 / Pesquisadores tem avaliado um grande número de técnicas de monitoramento para controlar a condição superficial de peças. O diafragma piezelétrico de titanato zirconato de chumbo (PZT) é utilizado em muitos campos de pesquisa, mas estes sensores não são comuns no mo-nitoramento dos processos de usinagem. Este trabalho propõe um método para monitorar a condição superficial da peça (usinagem normal e queima) usando um diafragma piezelétrico e técnicas de extração de características. Uma comparação é feita com o sensor convencional de emissão acústica (EA), que é um sensor amplamente utilizado no monitoramento dos proces-sos de usinagem. Os ensaios de usinagem foram realizados em uma máquina de retificação de superfícies utilizando aço ABNT 1045 e rebolo CBN, onde os sinais foram coletados a 2 MHz. As peças foram cuidadosamente analisadas por meio de inspeção visual, rugosidade superficial, medidas de dureza e análises metalográficas. Estudo do conteúdo de freqüência de ambos os sinais foi realizado com o objetivo de selecionar bandas estreitamente relacionadas com a condição da superfície da peça. Filtros digitais foram aplicados aos sinais puros e as características foram extraídas e analisadas. Os valores RMS (Root Mean Square) filtrados nas faixas selecionadas para ambos os sensores apresentaram um ajuste melhor à regressão linear, o que é altamente desejável para estabelecer um limiar para detecção da queima e im-plementação em um sistema de monitoramento. Além disso, os resultados do índice RMSD (Root Mean Square Deviation) mostraram um excelente comportamento para o monitoramen-to da queima decorrente do processo de retificação para ambos os sensores. O método foi va-lidado usando um rebolo diferente, o que mostra claramente sua eficácia e demonstra o uso potencial do diafragma piezelétrico de baixo custo para o monitoramento da queima no pro-cesso de retificação. / Researchers have evaluated a great number of monitoring techniques in order to control the surface condition of ground parts. Piezoelectric diaphragm of lead zirconate titanate (PZT) are used in many fields, but these sensors are not common in the monitoring of machining pro-cesses. This paper proposes a method for monitoring the workpiece surface condition (normal grinding and burn) by using a piezoelectric PZT diaphragm transducer and feature extraction techniques. A comparison is made with conventional acoustic emission sensor, which is a traditional sensor in the monitoring of machining processes. Grinding tests were performed in a surface-grinding machine with SAE 1045 steel and CBN grinding wheel, where the signals were collected at 2 MHz. The workpieces were thoroughly analysed through visual inspec-tion, surface roughness and hardness measurements, and metallographic analyses. Study on the frequency content of both signals was carried out in order to select bands closely related to the workpiece surface condition. Digital filters were applied to the raw signals and features were extracted and analyzed. The RMS values filtered in the selected bands for both sensors presented a better fitting to the linear regression, which is highly desirable for setting a threshold to detect burn and implementing into a monitoring system. Also, the RMSD index results show an excellent behavior for grinding burn monitoring for both sensors. The method was validated by using a different grinding wheel, which clearly shows its effectiveness and demonstrates the potential use of the low-cost piezoelectric diaphragm for grinding burn mon-itoring.

Page generated in 0.0688 seconds