• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de uma sonda de entalpia e aplicação ao maçarico de plasma

Cunha, Alfredo Gonçalves 08 August 1988 (has links)
Orientador: Aruy Marotta / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T08:48:43Z (GMT). No. of bitstreams: 1 Cunha_AlfredoGoncalves_M.pdf: 4006195 bytes, checksum: f00790c7bf28fdc0bed5885e67e7ecf0 (MD5) Previous issue date: 1988 / Resumo: Foi construída uma sonda de entalpia para diagnóstico da temperatura, pressão e velocidade do jato de plasma. Os principais resultados obtidos foram os seguintes: (i) foi feito uma análise teórica dos mais importantes fatores no uso da sonda: condição de equilíbrio termodinâmico, regime de escoamento do plasma, fluxo térmico, sensibilidade da sonda, balanço de massa, momento e energia do jato de plasma; (ii) foram calculados os parâmetros do maçarico de plasma a ar utilizando a teoria da similaridade e estes resultados foram comparados com os valores medidos, apresentando boa concordância; (iii) foi desenvolvido um cátodo de zircônio para o maçarico, permitindo que este operasse 38 horas sem reposição de eletrodos, sendo feito um estudo da taxa de erosão do cátodo; (iv) foram medidos os perfis de entalpia, temperatura, pressão e velocidade em 4 seções do jato de plasma; (v) foram calculados os fluxos de massa e energia do jato mostrando a partir do fluxo de massa uma forte penetração de gás ambiente no interior do jato e a partir do fluxo de energia foi possível mostrar que a sonda construída mediu com boa precisão a temperatura e velocidade do plasma tendo sido alcançado o objetivo da tese / Abstract: An enthalpy probe to determine temperature, pressure and velocity of a plasma torch was constructed. The main problems and results treated in this thesis were the following: (i) a theoretical analysis was performed of the most important factors for the probe: the thermodynamic equilibrium condition, the thermal flux. the sensitivity of the probe, the mass, momentum and energy balance of the plasma jet; (ii) the parameters of the plasma torch have being calculated and these results were compared with the measurements, showing good agreement; (iii) a zirconium cathode was developed, allowing na operation of 38 hours without replacement of the electrodes; the erosion rate of the cathode was measured; (iv) the enthalpy, temperature, pressure and velocity profiles in four sections along of the plasma jet was measured; (v) the flux of mass and energy of the jet have been calculated; from the mass flux it was deduced that there is a strong penetration of ambient gas inside the jet and from the energy flux it was possible to show that the probe truly measured the plasma temperature and velocity with good precision. Thus the principal objectives of this thesis have been attained. / Mestrado / Física / Mestre em Física
2

Desenvolvimento e aplicação da técnica de diagnóstico térmico-espectroscópico para estudo da interação de arcos elétricos com eletrodos frios

Bublievsky, Dmitry Alexandrovich 27 February 2003 (has links)
Orientador: Aruy Marotta / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-03T02:08:00Z (GMT). No. of bitstreams: 1 Bublievsky_DmitryAlexandrovich_M.pdf: 1177094 bytes, checksum: c681f9fa549216acb2481c1084c3e875 (MD5) Previous issue date: 2003 / Resumo: Nesta tese foi introduzido um novo tipo de técnica de diagnóstico da mancha de arcos elétricos, chamado térmico-espectroscópico. A técnica foi aplicada ao estudo da velocidade de rotação da mancha do arco e da densidade de corrente na mancha. Ambas estão relacionadas com os fenômenos que ocorrem na erosão de eletrodos frios. As medidas foram realizadas em um catodo de cobre não refrigerado, operando em ar, usando uma instalação coaxial magnética. As experiências mostraram que há dois regimes de erosão: micro e macroerosão. Observamos que para o regime de microerosão, a velocidade é sempre maior, e a dispersão da velocidade sempre menor que na macroerosão. Ambos os fatos confirmam a existência de uma força de arraste de superfície ao movimento do arco. Podemos explicar que a fonte dessa força é proveniente dos jatos catódicos no regime de macroerosão, fazendo com que a mancha tenha um movimento descontínuo. As dificuldades das técnicas tradicionais de medida da densidade de corrente na mancha foram superadas, introduzindo-se o conceito de densidade de corrente efetiva na mancha, pela qual mede-se o início da fusão na mancha e não o diâmetro da mancha. O método, baseado no registro espectroscópico temporal da intensidade da linha de emissão do vapor de cobre, juntamente com o registro da evolução da temperatura da superfície do eletrodo, permitiu um grande aumento na sensibilidade de detecção do ponto de transição do regime de micro para macroerosão. A densidade de corrente da mancha, medida como uma função do campo magnético, apresenta um grande crescimento para baixos valores do campo magnético. O estudo experimental realizado nesta tese permite uma melhor compreensão dos fenômenos que ocorrem em manchas de arcos elétricos de eletrodos frios, contribuindo, assim, para uma maior utilização das tochas de plasma / Abstract: In this thesis, we introduced a new type of arc spot diagnostic technique, called thermo-spectroscopic. Attention was concentrated on the study of arc spot rotation velocity and arc spot current density as a function of magnetic field. Both are related to cold electrode erosion phenomena. Measurements were carried out in an uncooled copper cathode in air, using a magnetically driven arc coaxial setup. Experiments have shown that there are two erosion regimes: a micro and a macroerosion one. We observed that for the microerosion regime, velocity was always higher and velocity dispersion lower than for the macroerosion one. Both facts confirm the existence of a surface drag force to the movement of the arc. We could explain that the source of this force is provided by cathode jets in the macroerosion regime, making the spot to move with frequent stops. We overcame the difficulties in traditional techniques in measuring spot current density by introducing the concept of effective arc spot current density, by which we measure the spot fusion onset and not the arc spot diameter. The method, based on the temporal spectroscopic registration of copper vapor atomic line emission intensity, together with the registration of the electrode surface temperature evolution, provided a significative increase in the sensibility of detection of the transition point from micro to macroerosion. The arc spot current density, measured as a function of magnetic field shows a strong increase for low magnetic field values. Experimental study, carried out in this thesis, allows a better understanding of the phenomenon taking place in cold electrode arc spot, thus contributing for a wider utilization of plasma torches / Mestrado / Física / Mestre em Física
3

Determinação da temperatura e densidade eletronica do plasma no Tokamak Nova-UNICAMP

Kaminishikawahara, Celso Ossamu 29 July 2004 (has links)
Orientador: Munemasa Machida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-11T21:04:46Z (GMT). No. of bitstreams: 1 Kaminishikawahara_CelsoOssamu_M.pdf: 1343678 bytes, checksum: 01d8d9e063e8f65d41507475b4fca60e (MD5) Previous issue date: 2004 / Resumo: O objetivo deste trabalho foi de implementar um sistema de diagnóstico na borda do plasma, na Região da Sombra do Limitador (RSL), do tokamak Nova-Unicamp, até então inexistente. O sistema de diagnóstico desenvolvido foi a sonda de Langmuir com a qual pudemos observar as variações temporais e espaciais da temperatura e densidade eletrônica na borda do plasma. Para a implementação desse sistema de diagnóstico no nosso tokamak foram construídas duas sondas de Langmuir , e desenvolvidas fontes de tensões de ondas senoidal e dente-de-serra, para alimentar essas sondas. Para o tratamento dos dados obtidos com a fonte de tensão dente-de-serra, foi desenvolvido um programa na linguagem C chamado Programa Langmuir, para uma determinação rápida da temperatura e densidade a cada disparo em descarga do tokamak. Com esse sistema implantado determinamos que a temperatura e a densidade eletrônica na interface entre o limitador e o plasma confinado, são 8,7 eV e 5,6x10 12cm -3respectivamente. E que o crescimento da densidade é mais abrupto que o da temperatura.Observamos também que as variações temporal da temperatura e densidade eletrônica ao longo da descarga mantiveram-se constantes nos valores de 8eV e 4x10 12cm -3respectivamente, na posição a 2mm atrás do limitador / Abstract: The objective of this work was to implement a system of diagnostic near the edge of the plasma, in the scrape-off layer (SOL) of tokamak Nova-Unicamp, up to time inexistent. The diagnostic system developed was the Langmuir probe with which we can observe the time and radial profiles of the electron temperature and density in the edge of the plasma. For the implementation of this diagnostic in our tokamak there have been constructed two Langmuir probes. To feed these probes, we have developed a sweep voltage power supply with sawtooth and sinusoidal waveform generator. For the treatment of the data obtained with sawtooth voltage source generator, it has been developed a program, in C language, named Langmuir Program, for a fast determination of the electron temperature and density to each tokamak discharge. With this system, we have determined that the eletron temperature and density at the interface between the limiter and the confined plasma, are 8.7 eV and 5.6x10 12cm -3 respectively, and that the growth of the density is more abrupt than the temperature. We also have observed that the time variations of the temperature and density, during the plateau of tokamak discharge, had respectively remained constant at the values of 8 eV and 4x10 12cm -3 , in the region 2mm behind the limiter / Mestrado / Física / Mestre em Física
4

Concentrações plasmáticas e peritoneal da proteína de fase aguda HMGB1 em bezerros portadores ou não de hérnias umbilicais /

Poló, Tatiane da Silva. January 2013 (has links)
Resumo:A HMGB1 pode atuar promovendo uma resposta inflamatória. Desta forma, os objetivos deste estudo foram quantificar sua concentração no plasma e no líquido peritoneal de bezerros com um processo crônico de hérnia umbilical, antes e após a herniorrafia, além de avaliar seu níveis durante paracenteses seriadas utilizadas como meio diagnóstico auxiliar para se avaliar a resposta inflamatória na cavidade abdominal. A presença de hérnia elevou os valores de HMGB1 no plasma e líquido e peritoneal. A herniorrafia não foi estímulo suficiente para aumentar as concentrações desta proteína no sangue. No entanto, no líquido peritoneal houve elevação dos níveis de HMGB1 em 7 a 15 dias após a cirurgia, decorrente do processo inflamatório esperado estabelecido na cavidade abdominal no pós-operatório. A realização de paracenteses seriadas foi capaz de elevar a concentração da HMGB1 apenas no líquido peritoneal, demonstrando um processo inflamatório local discreto, cujos valores retornam aos basais após um intervalo maior entre uma punção e outra. Sendo assim, a presença de hérnia umbilical congênita em bezerros causa reação local e sistêmica alterando os valores de HMGB1 tanto no plasma quanto no líquido peritoneal, enquanto a herniorrafia e a paracenteses seriadas provocam alterações nas concentrações de HMGB1 tardiamente apenas no líquido peritoneal / Abstract:HMGB1 protein may act by promoting an inflammatory response. Thus, the goals of this study were to quantify plasma and peritoneal fluid concentrations of HMGB1 in calves with or without congenital umbilical hernia before and after surgery, as well as assess their levels during serial paracentesis used as an auxiliary diagnostic tool for assessing the inflammatory response in the abdominal cavity. The presence of a congenital umbilical hernia caused increased values of HMGB1 in plasma and peritoneal fluid. The herniorraphy was not a stimulus intense enough to increase the concentration of this protein in the peripheral blood. However, in the peritoneal fluid, HMGB1 levels were increasead from 7 to 15 days after surgery, in response to the inflammatory process established in the abdominal cavity postoperatively. Serial paracentesis caused an increase of HMGB1 levels in the peritoneal fluid only, showing a mild inflammatory process, returning to baseline values after a longer interval between punctures. Thus, the presence of congenital umbilical hernias in calves cause local and systemic changes in HMGB1 levels both in plasma and in the peritoneal fluid while herniorraphy and serial paracentesis cause later changes in HMGB1 levels only in the peritoneal fluid / Orientador:Juliana Regina Peiró / Banca:Alexandre Secorun Borges / Banca:Valéria Marçal Felix de Lima / Mestre
5

Diagnóstico de um plasma criado por RF e imerso em campo magnético

Galvão, Geraldo Pereira 23 July 1981 (has links)
Orientador: Shuko Aihara / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-15T17:30:50Z (GMT). No. of bitstreams: 1 Galvao_GeraldoPereira_M.pdf: 1317175 bytes, checksum: 9e67735b434a694905c816924d12088e (MD5) Previous issue date: 1981 / Resumo: Este trabalho se constitui de duas partes principais: projeto de um analisador de energia de íons para medida de temperatura e outras propriedades de um plasma e estudo de um gás ionizado por radiofrequência e confinado em geometria de espelho magnético. Como diagnóstico desse sistema é usado, além do analisador de energia, sondas de Langmuir. O analisador é do tipo eletrostático. com placas metálicas cilíndricas paralelas e ângulo entre fendas de entrada e saída de 127° 17' .O detector de íons positivos é montado numa configuração denominada "Daly", e se constitui de um alvo metálico, fonte negativa de alta tensão, cintilador e fotomultiplicadora. Esse sistema é adequado para se trabalhar com correntes muito baixas de íons em plasmas estacionários ou pulsados. O emprego de sondas permite o estudo do comportamento da temperatura eletrônica paralela, da densidade e do potencial de plasma, sobretudo na ressonância de ciclotron dos elétrons. É desenvolvido um método para se calcular a temperatura perpendicular ao campo magnético. Com o analisador é feito um exame do comportamento do potencial de plasma com pressão e campo magnético. Observa-se uma variação na energia dos íons com estas grandezas. A interpretação desta variação em termos dá temperatura dos íons e/ou potencial de plasma é discutida no texto. Quando é possível comparam-se os dois métodos de medida / Abstract: The work presented here has two major parts. Firstly, I describe the construction of an ion energy analyzer to measure the temperature and other properties of plasmas. Secondly, I study the properties of a mirror-confined plasma created by radio frequency heating. In this study, the diagnostic of the plasma is carried out using the ion energy analyzer and Langmuir probes. The analyzer is of the electrostatic type with cylindrical and concentric metallic plates. The angle between the entrance and exit slits is 127° 17' .The detector is assembled in a "Daly" configuration and consists of a metallic target, a high-voltage negative power supply, a scintillator, and a photomultiplier. This system is appropriate to measure very small ion currents from steady-state or pulsed plasmas. The Langmuir probes are used to monitor the electron temperature parallel to the field lines, the plasma density and the potential. These measurements are particularly relevant in region of electron cyclotron resonance. A method to measure the temperature perpendicular to the field lines is also developed. The relationship between the plasma potential and magnitude of the kinetic pressure and magnetic field is studied using the energy analyzer. It is observed that the ion energy also varies with the pressure and the magnetic field. The correspondence between this variation and the ion temperature and/or the plasma potential is discussed. Some of the results of the analyzer are compared with these of a Langmuir probe / Mestrado / Física / Mestre em Física
6

Estudo da interação de arcos elétricos com catodo frio de cobre para ar e nitrogênio utilizando a técnica de diagnóstico termo-espectroscópica / Study of the interaction of the electric arc with cold copper cathode in air and nitrogen using the thermo-spectroscopic diagnostic technique

Bubliyeuski, Dzmitry Alexandrovich 27 May 2008 (has links)
Orientador: Aruy Marotta / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-10T20:43:05Z (GMT). No. of bitstreams: 1 Bubliyeuski_DzmitryAlexandrovich_D.pdf: 2691341 bytes, checksum: 7b8e0d82f84d333a723eb14e64832cf3 (MD5) Previous issue date: 2008 / Resumo: Uma nova técnica de diagnóstico, denominada termo-espectroscópica, foi introduzida neste trabalho para estudo da interação do arco elétrico com o catodo frio de cobre numa instalação coaxial magnética, com catodo não-refrigerado, operando em gases plasmagênicos ar e nitrogênio. A técnica foi aplicada ao estudo da velocidade de rotação da mancha do arco e da densidade efetiva de corrente na mancha. Estes parâmetros têm estreita relação com o fenômeno da erosão de eletrodos frios. A nova técnica combina a técnica óptico-espectroscópica e a técnica térmica, e se baseia na teoria térmica da erosão. Por espectroscopia, registra-se a evolução temporal da intensidade da linha de emissão do vapor de cobre. Pelo método térmico, registra-se a evolução da temperatura da superfície do eletrodo. A técnica permite um grande aumento na sensibilidade de detecção do ponto de transição do regime de micro para macroerosão, através da observação do abrupto aumento da intensidade da linha espectral do cobre. Observamos que para o regime de microerosão, a velocidade é sempre maior, e a dispersão da velocidade sempre menor que na macroerosão. Esse fato confirma a existência de uma força de arraste superficial ao movimento do arco, que pode ser proporcionada pela fusão do eletrodo, por jatos catódicos e/ou por óxidos na superfície do eletrodo. A densidade de corrente na mancha apresenta um grande crescimento para valores baixos do campo magnético e certa saturação para altos valores. Para o ar foi observada uma forte influência dos óxidos na mobilidade da mancha, que é significativamente maior do que com nitrogênio. A diferença entre medidas obtidas no ar e nitrogênio é atribuída ao processo de decomposição de óxidos na superfície, que afeta a determinação correta do ponto de transição. O estudo experimental realizado nesta tese permite uma melhor compreensão dos fenômenos que ocorrem em manchas de arcos elétricos de eletrodos frios / Abstract: In the present work a new diagnostic technique, named thermo-spectroscopic one, was introduced for study of the interaction of the electric arc with a cold copper electrode using the coaxial magnetic installation with non-refrigerated cathode operated in air and nitrogen. The technique was applied to the measurement of the arc spot rotation velocity and the effective spot current density. These parameters have a direct relation with the phenomenon of the cold electrode erosion. The new technique combines the optic-spectroscopic method and the thermal method, and is based on the erosion thermophysical theory. Using spectroscopy, the temporal evolution of the intensity of the copper vapor emission line was registered. Via the thermal method, the evolution of the electrode surface temperature was recorded. By the observation of the abrupt increase of the copper spectral line intensity, the new technique permits a significative increase in the sensibility of the detection of the transition from the microerosion process to the macroerosion one. It was observed that the arc velocity for the microerosion regime is always higher and the velocity dispersion is always lesser then the ones for the macroerosion regime. This fact confirms the existence of the surface drag force to the arc movement, which can be provided by the electrode fusion process, by cathode jets and/or by oxides formed on the electrode surface. The arc spot current density presents a high growth for the low values of the magnetic field and certain saturation for the high values ones. For the air, a strong influence of oxides on the spot mobility was observed, that is more significant then the one for the nitrogen. The difference between the measurements for the air and the nitrogen is attributed to the oxide decomposition process on the electrode surface that affects the correct transition point determination. The experimental study, carried out in this thesis, allows a better understanding of the phenomenon taking place in cold electrode arc spots / Doutorado / Física de Plasmas e Descargas Elétricas / Doutor em Ciências
7

Medidas da temperatura e densidade eletrônica utilizando a unicidade do tempo de confinamento de partículas no Tokamak NOVA-UNICAMP / Electronic density and temperature measurements using the particle confinement time iniqueness in the NOVA-Tokamak

Nascimento, Fellype do, 1980- 14 August 2018 (has links)
Orientador: Munemasa Machida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica, Gleb Wataghin / Made available in DSpace on 2018-08-14T10:48:49Z (GMT). No. of bitstreams: 1 Nascimento_Fellypedo_M.pdf: 4493365 bytes, checksum: 50c2d66d1ba6fb6004585fe057e964e5 (MD5) Previous issue date: 2009 / Resumo: Neste trabalho, foram feitas medidas simultâneas e três linhas e emissão e hidrogênio no tokamak NOVA-UNICAMP. A partir das medidas e brilho as emissões das linhas Ha , H b e Hg e fazendo uso de coeficientes que constam nas tabelas de Johnson e Hinnov, foi possível determinar temperaturas e densidades eletrônicas no plasma ao longo de descargas o tokamak. Para isto, foi utilizada, e aperfeiçoada, uma técnica desenvolvida num trabalho e doutoramento recente do nosso grupo, a qual faz uso do conceito de unicidade do tempo de confinamento de partículas. Os principais aprimoramentos realizados neste diagnóstico foram: utilização de três espectrômetros para medidas simultâneas das emissões e hidrogênio, instalação e fibras ópticas para coletar a luz emitida pelo plasma, adoção de um sistema de colimação para obter um certo grau e definição espacial nas medidas, uso de um maior número e valores e temperaturas na análise dos dados e desenvolvimento de um novo método (algorítimo) para obter os valores de temperaturas e densidades dos elétrons no plasma. As temperaturas e densidades eletrônicas médias obtidas ficaram em torno e 7,5 eV e 7,0 ·10 12cm-3, respectivamente. Estes valores estão entro do espera o para tais parâmetros na borda do tokamak NOVA-UNICAMP. Isto indica que este diagnóstico pode ser usado para monitorar ensidades e temperaturas e elétrons em plasmas gerados por tokamaks. Além isso, foram efetuados alguns experimentos com detectores multicanal e o gás hidrogênio foi trocado pelo hélio, na tentativa de mostrar a versatilidade do diagnóstico proposto. / Abstract: In this work, we have made simultaneous measurements of three hydrogen emission lines on our tokamak. From the measurements of absolute brightness of the Ha , H b e Hg lines an using data from Johnson an Hinnov table, was possible to determine electronic ensities an temperatures during the tokamak ischarges. For this,we have used, an refined, a technique developed in a recent PhD thesis in our work group. This technique uses the concept of particle confinement time uniqueness. The main upgrades made in this diagnostic were: the use of three spectrometers for simultaneous measurements of the hydrogen emissions, installation of optical fibers to collect the light emitte by the plasma, adoption of a collimation system for having some spatial definition of the measurements, use of a greater range of temperature values uring the data analysis and development of a new method (algorithm) for obtaining the electronic densities and temperatures in the plasma. The average temperature and density obtained was about 7.5 eV and 7.0 ·1012cm-3, respectively. The results obtained are in accordance with the expected values for these parameters at the edge of the NOVA-UNICAMP tokamak plasma. This indicates that this diagnostic can be used to monitor the electronic densities and temperatures in tokamak plasmas. Additionally, we have made experiments with multichannel detectors, and the hydrogen gas was replaced by helium, in an attempt to show the versatility of the proposed diagnostic. / Mestrado / Física / Mestre em Física
8

Obtenção de temperaturas e densidades de elétrons em plasmas de Tokamaks através de espectroscopia no visível de emissões de impurezas / Measurements of electron temperatures and densities in TokamaK plasmas using visible spectroscopy of impurity emissions

Nascimento, Fellype do, 1980- 23 August 2018 (has links)
Orientadores: Munemasa Machida, José Helder Facundo Severo / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-23T20:24:15Z (GMT). No. of bitstreams: 1 Nascimento_Fellypedo_D.pdf: 5773174 bytes, checksum: 260b32bb9f860cd7cda3a4c349ce7817 (MD5) Previous issue date: 2013 / Resumo: Este trabalho tinha como objetivo desenvolver um diagnostico para medir temperaturas e densidades de elétrons (Te e ne) em plasmas de tokamaks, utilizando espectroscopia no visível de emissões de impurezas presentes no plasma. Foram obtidos resultados para medidas locais de temperaturas e densidades de elétrons no plasma dos tokamaks NOVA-UNICAMP e TCABR, a partir de medidas de emissões espectrais de íons de carbono e oxigênio. Para este propósito foi utilizada a relação entre o fluxo de partículas de impurezas e as emissões espectrais provenientes delas. Esta relação foi combinada com um método interativo para obter valores de Te e ne. Tais resultados foram alcançados baseados na teoria de que o fluxo de partículas de um determinado elemento presente no plasma não depende do comprimento de onda em que seus íons estão emitindo radiação, no regime de equilibrio colisional-radiativo. No tokamak NOVA-UNICAMP foram obtidos resultados utilizando emissões espectrais de carbono e oxigênio, porem apenas em um nível de ionização de tais elementos (C1+ e O1+). Nesta maquina, as medidas de três linhas de emissão provenientes de cada íon foram efetuadas de forma simultânea, ou seja, em um único disparo. Já no tokamak TCABR foram gerados resultados com emissões de três níveis de ionização do carbono (C1+, C2+ e C5+), mas as aquisições de dados nesta maquina foram realizadas em descargas diferentes, tendo sido medido um comprimento de onda emitido por um dado íon em cada disparo. Para todos os íons utilizados, e nas duas maquinas em que foram feitas medidas, os valores obtidos para as temperaturas de elétrons estão de acordo com os esperados para as regiões do plasma onde e maior a probabilidade de que cada íon em questão emita radiação. No caso especifico do TCABR, onde foram feitas medidas de emissões de três níveis de ionização do carbono, isto fica mais evidente, pois valores mais elevados de temperatura foram observados para maiores níveis de ionização. As densidades de elétrons que foram obtidas concordam em ordem de grandeza com os valores esperados, para todos os íons utilizados no trabalho, nos dois tokamaks. Porem os valores medidos estão acima do esperado, exceto para os resultados obtidos no TCABR com emissões de C5+. No tokamak TCABR foi possível comparar os resultados de ne obtidos pelo nosso método com os que são medidos por interferometria de micro-ondas. Na comparação, notou-se que o perfil temporal de ne medido com o nosso método esta em bom acordo com que foi obtido com o interferômetro. De um modo geral, os resultados obtidos foram bons, e podemos considerar que os objetivos deste trabalho de tese foram cumpridos / Abstract: In this work we got results for measurements of local electron temperatures and densities (Te and ne) at NOVA-UNICAMP and TCABR tokamak plasmas, by using visible spectroscopy of line emissions from carbon and oxygen ions, which are impurities in the plasma. For this purpose, we used the relationship between the particle flux and the photon flux emitted by an element (or an ion) at a fixed wavelength. That relationship was combined with an interactive method in order to determine Te e ne values. Such results were achieved based on the theory that the particle flux of a given ion specie in the plasma does not depend on the wavelength of the light emitted by the ion. For NOVA-UNICAMP tokamak we got results using spectral emissions of carbon and oxygen for only one ionization stage of these elements (C1+ and O1+). In this machine, we have made simultaneous measurements of each set of three spectral emissions from each ion specie in the same tokamak shot. For TCABR tokamak we got results using spectral emissions from three ionization stages of carbon (C1+, C2+ and C5+). But the data acquisition in this machine were made in different tokamak discharges, where we measured one spectral emission per time for each ion. The electron temperatures obtained with all ion emissions used in this work and in both machines are in good agreement with the expected values at the plasma position where each kind of ion has larger probability of be radiating. This fact become more evident in the TCABR tokamak, where we have emissions measurements of three carbon ionization stages, because higher Te values were measured for ions at higher ionization stages. All results obtained for electron densities agree in magnitude order, for both machines, with the expected values for this parameter. But the measured values are higher than the expected, except for the results obtained using C5+ emissions at TCABR tokamak. In TCABR was possible to compare the ne results obtained in our method with measurements made using a microwave interferometer. In that comparison we noted that the temporal profile of both diagnostics are in good agreement. The general conclusion is that the results obtained with our method were good and we consider that the objectives of this work were fulfilled / Doutorado / Física / Doutor em Ciências

Page generated in 0.0602 seconds