• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Towards cold state-selected ion-molecule reactions

Deb, Nabanita January 2014 (has links)
In recent years there has been much progress in the field of cold and ultracold molecular physics and a variety of experimental techniques for producing cold matter now exist. In particular, the generation of trapped molecular ions at mK temperatures has been achieved by sympathetic-cooling with laser-cooled atomic ions. By implementing schemes to selectively prepare and control the internal quantum state of molecular ions, and developing detection techniques, it will be increasingly possible to study cold state-selected chemical collisions in an ion-trap. Most molecular species produced in a selected rovibrational state have a lifetime of a few seconds, before the population is redistributed across numerous rovibrational states by interaction with the ambient blackbody radiation (BBR). Consequently, the investigation of state-selected reaction dynamics at low temperatures in experiments where long time scales (minutes to hours) are required, is hindered. This thesis looks into developing strategies that maintain state selection in molecular ions, allowing one to observe state-selected reactions in cold environments, in particular the state-selected reaction between C<sub>2</sub>H<sup>+</sup><sub>2</sub> and ND<sub>3</sub>. Examining reactive ion molecule collisions under cold conditions provides insight into fundamental reaction dynamics, which are thermally averaged out at higher temperatures. A theoretical model is used to investigate laser-driven, blackbody-mediated, rotational cooling schemes for several <sup>1</sup>&Sigma; and <sup>2</sup>Π diatomic species. The rotational cooling is particularly effective for DCl<sup>+</sup> and HCl<sup>+</sup>, for which 92&percnt; and >99&percnt; (respectively) of the population can be driven into the rovibrational ground state. For the other systems a broadband optical pumping source is found to enhance the population that can be accumulated in the rovibrational ground state by up to 29&percnt; more than that achieved when exciting a single transition. The influence of the rotational constant, dipole moments and electronic state of the diatomics on the achievable rotational cooling is also studied. This approach is extended to consider the BBR interaction and rotational cooling of a linear polyatomic ion, C<sub>2</sub>H<sup>+</sup><sub>2</sub>, which has a <sup>2</sup>&Pi; electronic ground state. The (1-0) band of the &nu;<sub>5</sub> cis-bending mode is infrared active and strongly overlaps the 300 K blackbody spectrum. Hence the lifetimes of state-selected rotational levels are found to be short compared to the typical timescale of ion trapping experiments. Laser cooling schemes are proposed that could be experimentally viable, which involves simultaneous pumping of a set of closely spaced Q-branch transitions on the <sup>2</sup>&Delta;<sub>5/2</sub>-<sup>2</sup>&Pi;<sub>3/2</sub> band together with two <sup>2</sup>&Sigma;<sup>+</sup>– <sup>2</sup>&Pi;<sub>1/2</sub> lines. It is shown that this should lead to >70&percnt; of total population in the lowest rotational level at 300 K and over 99&percnt; at 77 K. In order to identify states of the acetylene ion that could be trapped sufficiently long enough for state-selected reactions in the ion trap with decelerated ND3, the theoretical work has been complemented by experimental investigations into the production of C<sub>2</sub>H<sup>+</sup><sub>2</sub> in selected states, and ion trapping of the same using sinusoidal and digital trapping voltages. Appropriate (2+1) REMPI (Resonance Enhanced Multiphoton Ionization) schemes are used to produce C<sub>2</sub>H<sup>+</sup><sub>2</sub> in different quantum states, with (1+1) Resonance Enhanced Multiphoton Dissociation (REMPD) employed to detect the ion thus produced. The concept of digital ion trapping for ejection onto MCPs is introduced. A comprehensive comparison between sinusoidal and digital trapping fields has been performed with respect to trap depth and stability regions. Programs have been developed to calculate the stability regions for different ions under varying experimental conditions. The trap depth has been derived for both digital and sinusoidal trapping fields. It is observed that as &tau; increases, the trap depth of a digital trap increases. For &tau; = 0.293, the trap depth and stability diagram for both sinusoidal and digital trapping fields would be equivalent. The trap depth at which the sinusoidal trap operates experimentally in our research group is ~1.36 eV. In contrast, the experimental parameters at which the digital trap operates generates a trap depth of 1.21 eV. Ca<sup>+</sup> Coulomb crystals have been formed, stably trapped and stored for extended periods of time in both sinusoidally and digitally time-varying trapping fields. The sympathetic cooling of a diverse range of ions into Ca<sup>+</sup> Coulomb crystals is demonstrated, again using both sinusoidal and digital trapping fields. Mass spectrometric detection of ionic reaction products using a novel ejection scheme has been developed, where ejection is achieved by switching off the trapping voltage and converting the quadrupole trap into an extractor-repeller pair by providing the ion trap electrodes with appropriate ejection pulses. This technique is developed using a digital trapping voltage rather than the sinusoidal trapping voltage, as ejection with sinusoidal trapping voltages is not clean (resonance circuitry used in the electronics induces ringing after switching off the trapping voltage). Coulomb crystals, both pure Ca<sup>+</sup> and multi-component crystals, are ejected from the ion trap and the TOF trace obtained is recorded on an oscilloscope. When the integrated, base-line subtracted TOF peak is plotted against the number of ions in a Ca+ crystal and sympathetically-cooled Ca<sup>+</sup> – CaF<sup>+</sup> crystal, a linear relationship is obtained. This technique is found to be well mass-resolved, with the signal arising from CaOH<sup>+</sup> (57 amu) and CaOD<sup>+</sup> (58 amu) resolvable on the TOF trace. This technique would enable one to monitor a reaction in a Coulomb crystal where the reactant and product species are both either lighter or heavier than calcium, such as the reaction between C<sub>2</sub>H<sup>+</sup><sub>2</sub> and ND<sub>3</sub>, something which has not been previously possible. It is, also, potentially a very important technique for reactions with many product channels.
2

<b>Development of a digital Dual-trap mass spectrometer for gas-phase ion/ion chemistry studies of High-Mass Biomolecules</b>

Liangxuan Fu (19154452) 17 July 2024 (has links)
<p dir="ltr">Multiply-charged ions of intact biomolecules generated from electrospray ionization (ESI) have drawn researchers' interest in the field of native mass spectrometry (MS) for decades because these ions carry mass and charge information of the intact molecules and interactions among different units. However, the confinement of multiple charge states in a narrow range of <i>m/z</i> makes mass and charge assignments challenging, especially for analytes with a mass greater than 100 kDa. Gas-phase ion/ion reactions have proven to be powerful techniques that facilitate the interpretation of mass spectra of natively sprayed macromolecular analytes by manipulating the masses and charges of ions detected.</p><p dir="ltr">The proton-transfer reaction (PTR) is the most used gas-phase ion/ion reaction method. It utilizes perfluorinated PTR reagents to "grab" protons away from the analyte ions, thereby reducing their charges. A novel charge state manipulation technique called "ion parking," based on PTR, has been developed. In this method, ion signals are accumulated to one or a range of charge states by selectively inhibiting reactions between the target charge state and the PTR reagents via resonance excitation.</p><p dir="ltr">The multiply-charged ion attachment (MIA) reaction is another gas-phase ion/ion reaction approach. It utilizes the significant <i>m/z</i> displacement caused by the attachment of multiply-charged reagent ions, and it has been proven useful for mass analysis of heterogeneous macromolecular analytes with a mass greater than 1 MDa.</p><p dir="ltr">All gas-phase ion/ion reaction techniques require mutual storage of ions in opposite polarities within an electrodynamic quadrupole ion trap, such as a 3D quadrupole ion trap (QIT) or a linear quadrupole ion trap (LIT). Electrodynamic ion traps use high-voltage (HV) drive radio frequencies (RF) to trap ions in a quadrupolar field, typically employing a sinusoidal waveform (sine wave). A digital quadrupole ion trap (DIT) is an unconventional electrodynamic ion trap that uses a digital waveform (square wave) as the drive RF. The high agility of square waves makes DIT an ideal mass analyzer for studying high <i>m/z</i> ions resulting from gas-phase ion/ion reactions. This dissertation describes the development of a novel home-built digital dual-trap mass spectrometer and ion/ion chemistry studies of large biomolecules within the instrument.</p>

Page generated in 0.064 seconds